Download Vision Sensor User manual
Transcript
Vision Sensor User manual 4.6.3.4.2 Function: Edit contour s. chap.: Detector Pattern matching Function: Mask 4.6.3.4.3 Settings in Angle tab: Detector Contour (Page 66) Settings in Scaling tab: (Page 69) Contour application: (Page 70) Function: Mask (Page 64) Parameters Functions Angular zone Angular zone in which search is carried out Increment (angle) Sensitivity of search throughout the selected angular zone in ° Accurate - fast Candidates with score less than indicated will already be rejected during search. High value: early rejection = quicker = riskier Small value: late rejection = slower = less risky In case of false results this value can be decreased. Fig. 63: Detector contour, tab angle 4.6.3.4.4 Settings in Scaling tab: Detector Contour (Page 66) Settings in Scaling tab: (Page 69) Contour application: (Page 70) Function: Mask (Page 64) Parameters Functions Scale min/max Detection also of enlarged or reduced objects in a given scale range Vision Sensor SBSI-EN, 8033104 - 1401N12.05.2014 Page 69