ConveyorControl Planning Out 1, Out 2 and Relay ID Name POUT1 This tab includes the parameters for the outputs of the ComControl in the terminal box. Meaning Value range Default setting LogicType Output type (only with Out 1 and Out 2) PNP (cannot be set) PNP POUT2 SwitchType Switch type Normally open Normally closed Normally open POUT3 Function Function assignment Not used Error signal Aux RD start* Zone status Sensor signal Input signal 2 Input signal 3 Not used POUT4 SignalDelay Signal delay 1 – 10 s in 0.1 s increments 0 = no delay 0 * Output is switched parallel to RollerDrive. CentralControl The CentralControl must not be parameterized, the parameters can merely be read out. ID Name Meaning Value range Default setting PG1 ControlMode Central or decentralized conveyor control Cannot be set Decentralize d NodeID Numbering Cannot be set – ProductKey Article number of the module Cannot be set – Serial Serial number of the module Cannot be set – 40 Version 2.0 (04/2013) en Translation of the original instructions