Download CNC 8055 - Installation manual

Transcript
Installation manual
Work levels for sinusoidal signal (only for axes).
A and B signals
Amplitude: 0.6 ÷ 1.2 Vpp
Centered: |V1-V2| / 2 Vpp =< 6,5%
Relationship: VApp / VBpp = 0.8 ÷ 1.25
Phase shift: 90º ± 10º
Reference mark (I0) Amplitude: 0.2 ÷ 0.85 V
Width: T-90º =< I0 =< T+180º
CNC structure
Maximum frequency 500 kHz.
CNC 8055I CONFIGURATION
2.
Feedback input for the handwheels
Power supply consumption of +5 V 1 A (250 mA per axis).
Work levels for differential square signal.
Maximum frequency:
400 kHz.
Maximum gap between flanks:
460 ns.
Phase shift:
90º ± 20º.
Vmax in common mode:
± 7 V.
Vmax in differential mode:
± 6 V.
Hysteresis:
0.2 V.
Maximum differential input current:
3 mA.
Work levels for non-differential square signal.
Maximum frequency:
400 kHz.
Maximum gap between flanks:
460 ns.
Phase shift:
90º ± 20º.
High threshold (logic level "1") VIH:
1,25 V < VIH < 7 V.
Low threshold (logic level "0") VIL:
-7 V < VIL < 1 V.
Vmax:
± 7 V.
Hysteresis:
0.25 V.
Maximum differential input current:
3 mA.
CNC 8055
CNC 8055i
SOFT: V01.6X
·79·