Download Maxband User Guide

Transcript
Sample Data Collection Process
R
Figure 6. Stabilized Temperature Measurement Example
T-sys calculation
y = 1.3785x + 8.2372
R2 = 0.9932
45.00
40.00
35.00
30.00
25.00
Tdiode-Ta
20.00
Linear (Tdiode-Ta)
15.00
10.00
5.00
0.00
0.00
5.00
10.00
15.00
20.00
25.00
Figure 7. Graph For T-sys Calculation
A trend line through the data points will reveal a linear fit y = mx + b where the slope (m) is the
thermal resistance of the system (θj-a) and the y-intercept is the measured system effect (Tsystem).
22
Intel Confidential