Download Simrad SimNet Installation Manual
Transcript
Installation Manual Example: Figure 3-4 Large system 16 products interconnected via 92 meter (306’) network cable The best place to feed the network power is the point where the SF (L ● NL) value in each of the branches is most equal. However, it will work without problems as long as the SF value in each branch is below 600. • Determine the total NL values separately for both the left and right branches. • Add up the cable length separately for each of the two branches (exclude the 30 meter wind sensor cable). • Calculate the SF (left) and SF (right). Make sure that each SF is below 600. • If one branch has a too high SF, try to better balance the network by moving the power cable and T-joiner into the branch with the higher SF. 20222006 / Rev. A www.busse-yachtshop.de | [email protected] 19