Download User Manual - Stemmer Imaging

Transcript
User Manual
Serval-640
Serval-384
5.12. Image processing control
For the current configuration as industrial radiometric camera (Serval Thermography
camera) we disable the additional image processing features of the Xenics-XTM.
Name
ImageProcessingControl
Interface
ICategory
Access
R
Unit
-
Visibility
B
Display name
Image processing
control
Description
Category that contains the
XTM image processing
features
Table 5-15 Image processing control
5.12.1. Auto gain and offset control
Display name
Description
AutoGainControl
Name
ICategory
Interface
R
Access
Unit
-
B
Visibility
Auto gain control
GainControl
OffsetControl
AutoModeUpdate
IEnumeration
IEnumeration
IEnumeration
R/W
R/W
R/W
-
B
B
E
OffsetUsed
GainUsed
ManualModeControl
IFloat
IFloat
ICategory
RO
RO
R
-
B
B
B
ManualModeOffset
ManualModeGain
AutoModeControl
IFloat
IFloat
ICategory
R/W
R/W
R
-
B
B
E
AutoModeOutputHistogramMidp
oint
AutoModeMaximalGain
IFloat
R/W
E
IFloat
R/W
E
Gain control
Offset control
Auto mode
update
Offset used
Gain used
Manual mode
control
Offset
Gain
Auto mode
control
Output histogram
midpoint
Maximal gain
Subcategory that contains the
AGC features (subcat of
Image processing control)
Automatic, Manual
Automatic, Manual
Running, Stopped
AutoModeRegulationSpeed
IInteger
R/W
E
Regulation speed
OutliersControl
ICategory
R
-
E
Outliers control
OutliersExpressedAs
IEnumeration
R/W
-
E
Expressed as
OutliersDark
OutliersBright
OutliersBrightDisplayColor
IFloat
IFloat
IEnumeration
R/W
R/W
R/W
-
E
E
E
InputHistogramControl
ICategory
R
-
E
InputHistogramBegin
IFloat
R/W
E
Dark
Bright
Bright display
color
Input histogram
control
Begin
InputHistogramMidpoint
IFloat
R/W
E
Midpoint
InputHistogramEnd
IFloat
R/W
E
End
Currently applied offset
Currently applied gain
Subsubcategory (subcat of
Auto gain control)
Manual offset level
Manual gain factor
Subsubcategory (subcat of
Auto gain control)
Target point for automatic
offset leveling
Maximum allowed automatic
gain
Speed of automatic offset/gain
changes
Subsubcategory (subcat of
Auto gain control)
% of the image size, % of the
maximal intensity
Dark outliers to ignore
Bright outliers to ignore
White, Black
Subsubcategory (subcat of
Auto gain control)
Desired starting point in the
input histogram
Desired midpoint in the input
histogram
Desired end point in the input
histogram
Table 5-16 Auto gain and offset control
Company confidential.
This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third
party without written permission from Xenics.
Xenics nv
Ambachtenlaan 44
BE-3001 Leuven  Belgium
T +32 16 38 99 00
F +32 16 38 99 01
www.xenics.com
Doc Ref: ENG-2014-UMN008
Issue: R001
Date: 15/04/2015
XF-104_02/20-01-2012