Download PROGRAMMABLE AC POWER SOURCE 61705 User's Manual

Transcript
Remote Operation
TRIG
Description
Query Syntax
Parameters
Return Parameters
: This command sets LIST mode in OFF, ON execution state
after setting OUTPut : MODE LIST. If users want to change
the parameters, it’s necessary to set TRIG OFF then OUTPut :
MODE FIXED. Then, set OUTPut : MODE LIST again to get
ready to set TRIG ON.
: TRIG : STATE?
: OFF | ON
: OFF | RUNNING
8.6.2.9 PULSE Sub-system
[SOURce :]
PULSe
: VOLTage
: AC
: DC
: FREQuency
: SHAPe
: SPHase
: COUNt
: DCYCle
: PERiod
OUTPut
: MODE
TRIG
TRIG : STATE?
[SOURce :] PULSe : VOLTage : AC
Description
: This command sets AC voltage in the duty cycle of PULSE
mode.
Query Syntax
: [SOURce :] PULSE : VOLTage : AC?
Parameters
: <NR2>, valid range: 0.0 ~ 150.0 (in low range), 0.0 ~ 300.0
(in high range)
Return Parameters
: <NR2>
[SOURce :] PULSe : VOLTage : DC
Description
: This command sets the DC voltage in the duty cycle of
PULSE mode.
Query Syntax
: [SOURce :] PULSE : VOLTage : DC?
Parameters
: <NR2>, valid range: -212.1 ~ 212.1 (in low range), -424.2 ~
424.2 (in high range)
Return Parameters
: <NR2>
[SOURce :] PULSe : FREQuency
8-23