Test Descriptions
Internal Loopback - ILB
Verifies that the 82596 can be operated in the "Internal Loopback" mode.
The 82596 has three modes of loopback: Internal Loopback, External Loopback
with the LPBK pin activated, and External Loopback with the LPBK pin not
activated. The LPBK pin is connected to the accompanying Ethernet Serial
Interface (ESI - 82C501AD) chip. The ESI is then connected to the pulse
transformer (PE64102), which in turn is connected to the Ethernet Connector.
3
In Internal Loopback mode the 82596 disconnects itself from the serial link and
logically connects TXD to RXD and TXC to RXC. The TXC frequency is
internally divided by four during internal loopback operation.
The test sets up a data packet (incrementing data pattern) to be transmitted,
transmits it, and waits for the reception of the data. Once the data is received,
the data is verified to the data transmitted. This transmit to receive loop is
performed 32 times. Use the CF LANC command to change the loop count.
Command Input:
162-Diag>LANC ILB
Response/Messages:
After the command has been issued, the following line is printed:
LANC
ILB: Internal Loopback...................... Running --->
If all parts of the test are completed correctly, then the test passes:
LANC
ILB: Internal Loopback...................... Running ---> PASSED
If any failures occur, the following is displayed (more descriptive text then
follows):
LANC
ILB: Internal Loopback...................... Running ---> FAILED
(error message)
Once the data packet has been set up to be transmitted, the test instructs the
82596 (through the Command Unit) to transmit the data packet. This failure is
the result of the 82596 completing with a transmit data error. The status bits
of the error message display indicate the source of the problem:
TRANSMIT Command Completion Status Error:
OK-Bit =0, ABORT-Bit =0, STATUS-Bits =0010
3-114