Download SPLIT SYSTEM AIR CONDITIONER

Transcript
Indoor Unit
Outdoor Unit
AWR512HL
AER512SH
Power Source
220–240V ~ 50Hz
Voltage rating
230 V
Performance
Capacity
kW
BTU/h
m3/h
Liters/h
Air circulation (High)
Moisture removal (High)
Cooling
Heating
3.30
11,424
4.10
13,98
430
1.3
Electrical Rating
—
Cooling
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
V
A
W
%
W/W
A
Heating
198 ~ 264
6.2
1,300
95
2.5
33
6.6
1,400
94
3.0
33
Features
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Microprocessor / I.C. thermostat
Wireless remote control unit
ON/OFF 24 hours & Daily program,1-hour OFF
3 and Auto / 1(Hi)
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R407c / 1,150
Capillary tube
39 / 35 / 33
39 / 35 / 33
45
47
Flare type
7.5
6.35(1/4)
12.7(1/2)
Optional / Air Clean Filter
Indoor / Outdoor
Horizontal
Vertical
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Indoor : Hi / Me / Lo
Outdoor : Hi
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant
Narrow tube
tube diameter
Wide tube
Refrigerant tube kit / Accessories
g
dB-A
dB-A
m
mm (in.)
mm (in.)
Dimensions & Weight
Unit dimensions
Package dimensions
Weight
Shipping volume
Height
Width
Depth
Height
Width
Depth
Net
Shipping
mm
mm
mm
mm
mm
mm
kg
kg
m3
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating : Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
4
Indoor Unit
Outdoor Unit
270
805
177
243
855
332
8.0
10.0
0.07
540
700
265
568
815
343
38.0
41.0
0.16
DATA SUBJECT TO CHANGE WITHOUT NOTICE.