Invert Image Properties
Invert Image Transform properties appear on the Operations Browser for iImage only.
The operation has no unique properties.
Byte Scale Properties
Byte Scale properties appear on the Operations Browser for iImage only. For each
property, the type of control and the values that can be assigned are listed. For a
description of how a particular control is used, refer to Appendix B, “Property
Controls”.
Property
Control Type: Options
Automatic
Min/Max
Boolean: Automatically compute minimum and maximum
values? Choose True or False. Default = True
Minimum cutoff
Number: Minimum value of array to be considered. Edit the
number to change the value. Default = 0
Maximum cutoff
Number: Maximum value of array to be considered. Edit the
number to change the value. Default = 255
Bottom byte
Number: Minimum value of scaled result. Edit the number to
change the value. Range = 0-255. Default = 0
Top byte
Number: Maximum value of scaled result. Edit the number to
change the value. Range = 0-255. Default = 255
Table C-25: Byte Scale Transform Properties
Note
When working with byte data, the default bytescale range is always 0-255.
Therefore, even if data is bytescaled from 0-100, it will display using 0-255. This
may cause visualized data to appear darker.