Technical data
Parameter
Values
 10
Power stage clock frequency (kHz)
Output current (ARMS)
8
Max. output current (ARMS)
16
24
32
Max. allowed time (s)
5
0,7
0,2
Power stage clock frequency (kHz)
12
Output current (ARMS)
7,4
Max. output current (ARMS)
Max. allowed time (s)
14,8
22,2
29,6
5
0,7
0,2
Power stage clock frequency (kHz)
16
Output current (ARMS)
6,3
Max. output current (ARMS)
Max. allowed time (s)
12,6
18,9
25,2
5
0,7
0,2
Power stage clock frequency (kHz)
19
Output current (ARMS)
5,2
Max. output current (ARMS)
Max. allowed time (s)
10,4
15,6
20,8
5
0,7
0,2
Table 17: servoTEC S2108 FS: Rated current for blocked or slowly
rotated servo motor (fel) 2 Hz and
for an ambient temperature of  40 °C