Download Operating instructions
Transcript
Technical data Parameter Values 10 Power stage clock frequency (kHz) Output current (ARMS) 8 Max. output current (ARMS) 16 24 32 Max. allowed time (s) 5 0,7 0,2 Power stage clock frequency (kHz) 12 Output current (ARMS) 7,4 Max. output current (ARMS) Max. allowed time (s) 14,8 22,2 29,6 5 0,7 0,2 Power stage clock frequency (kHz) 16 Output current (ARMS) 6,3 Max. output current (ARMS) Max. allowed time (s) 12,6 18,9 25,2 5 0,7 0,2 Power stage clock frequency (kHz) 19 Output current (ARMS) 5,2 Max. output current (ARMS) Max. allowed time (s) 10,4 15,6 20,8 5 0,7 0,2 Table 17: servoTEC S2108 FS: Rated current for blocked or slowly rotated servo motor (fel) 2 Hz and for an ambient temperature of 40 °C MAN_EN_1121146_LV-servoTEC_S2_1xx_FS_R1b.doc Operating instructions servoTEC S2 1xx FS Page 47 of 163 Mai 2015