Download Panasonic 36PEF1U6 Data Sheet
Transcript
Split System Submittal Data System: 36PEF1U6 Indoor: S-36PF1U6 Outdoor: U-36PS1U6 Single Split System - Concealed Duct Heat Pumps Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15-35 Indoor-Outdoor 15-35 Indoor-Outdoor Compressor No. Used R.L. Amps - L.R. (A) DC Rotary Inverter 1 16.4 - 17.5 Outdoor Unit Fan type Dia & Length (in.) - No. used Type Drive - No. Speeds No. Poles (RPM) No. Motors (W) CFM (High) F.L. Amps (A) Propeller 18-7/64-1 DC Motor 8 - 830 1 - 90 1942 17.3 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Aluminum Fin & Copper Pipe Slit Plate - Inner Rifled 2 - 14.1 7.26 3/8" Indoor Unit Fan type Dia & Length (in.) - No. used No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (HI/Med/Lo) Indoor Sound Rating (Hi) (dB-A) F.L. Amps (A) Centrifugal 5-29/32-3 3 & Auto 4 - 940 1 - 100 1060/920/750 38 1.0 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Drain Connection Size (in.) Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 3 - 12.7 3.32 3/8" 1-17/64" Refrigerant Lbs. - R410a Control Connection Line Length, Max (ft.) Line Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) R410A 6.17 Electric Expansion Valve Flare 165 50 (outdoor lower), 100 (outdoor higher) 3/8" 5/8" Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 14-3/32 x 65-25/32 x 30-13/16 12-7/32 x 58-9/32 x 24-13/16 34-31/32 x 39-31/32 x 16-3/32 30-23/32 x 37 x 13-3/8 Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 104 115 143 161 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 16.5 13 Performance Data @ ARI Standard Conditions (230/208V) Option Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) High Refrigerant Line Set Fresh Air Intake Airduct Extension Indoor Frame Extension Condensate Drain Pump Non-Removeable Locking Remo-con Bracket Heating Total Capacity (BTU/H) HSPF Amps (A) Max Amps (A) Power Inputs (W) Back-up Strip Heather (KW) Outdoor Sound Rating (dB-A) High 31,200 (9,500 - 31,200) 19,570 11,630 13.9 10.0 18.6/20.6 3,920/3,920 52 37,400 (8,000 - 37,400) 9.6 15.6/17.3 15.6/17.3 3,250/3,250 N/A 52 Features Controls Remote Controller Temperature Control Timer Night Setback Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Changeover Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor (Wired Remote Included) (Wireless Remote Optional) IC Thermostat 72 Hr. On/Off N/A N/A N/A Built-In Built-In Built-In Field Supplied Available N/A N/A N/A Built In (Limited Vertical Lift) Available Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) 95F DB/71F WB 67 DB/57F WB 80F DB/67F WB -DB/-WB 115F DB 0F DB 75F DB/65F WB 5F DB 2-15/16 2-9/16 1-9/16 12-7/32 13-3/16 13-3/16 11 11-7/32 1-3/8 5-1/8 1915_U_I 13-3/16 13-3/16 12-7/32 2-15/16 2-9/16 4-17/32 Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Upper drain port (O.D. 1-1/4) Bottom drain port (O.D. 1-1/32) Suspension lug Power supply inlet (conduit size 1/2") Fresh air intake port (ø5-29/32) Flange for the flexible air outlet duct (ø7-7/8) Tube cover Electrical component box Flange for the air intake duct (option or field supply) 13-3/16 10 1-9/16 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 9 (5-29/32) 9 10 58-9/32 3-17/32 Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Upper drain port (O.D. 1-1/4) Bottom drain port (O.D. 1-1/32) Suspension lug Power supply inlet (conduit size 1/2") Fresh air intake port (ø5-29/32) Flange for the flexible air outlet duct (ø7-7/8) Tube cover Electrical component box Flange for the air intake duct (option or field supply) 3-11/32 Dimension : inch 11 Dimension : inch 2-3/4 61-13/32 (Suspension bolt pitch) Inspection access (17-23/32 × 17-23/32) (Field supply) 18-ø1/8 (Hole) 1-7/32 9-1/16 3/4 31/32 2-3/4 13-3/16 58-9/32 61-13/32 (Suspension bolt pitch) 31/32 6-7/8 31/32 8-9/32 12-7/32 1-7/32 10-1/4 15/16 (Air outlet duct flange) 7-9/32 3-17/32 13-3/16 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 22-27/32 (Suspension bolt pitch) 31/32 6-5/16 1-3/16 24-13/16 13/32 31/32 11 1-4 Dimensional Data 7-9/32 Outdoor Dimensions 7-15/32 9-1/16 P × 6 = 54-11/32 31/32 (5-29/32) 18-ø1/8 (Hole) 9-1/16 10 9-1/16 P × 6 = 54-11/32 56-25/32 (Air outlet duct flange) Indoor unit : Low Silhouette Duct Type 36 Type 56-25/32 (Air outlet duct flange) 1-7/32 22-27/32 (Suspension bolt pitch) 4-17/32 1-4 Dimensional data 1-7/32 15/16 1-4 Dimensional Data 13-3/16 12-7/32 2-15/16 2-9/16 4-17/32 13-3/16 58-9/32 61-13/32 (Suspension bolt pitch) 9-1/16 9-1/16 P × 6 = 54-11/32 56-25/32 (Air outlet duct flange) 10-1/4 (Air outlet duct flange) 3/4 2-3/4 3-11/32 1-9/16 2-3/4 Inspection access (17-23/32 × 17-23/32) (Field supply) 18-ø1/8 (Hole) 1-7/32 15/16 3/4 11 10-1/4 (Air outlet duct flange) 11 31/32 6-5/16 1-3/16 24-13/16 13/32 31/32 (5-29/32) 31/32 Indoor Dimensions 11-7/32 1-3/8 5-1/8 8-9/32 12-7/32 31/32 6-7/8 7-15/32 Inspection access (17-23/32 × 17-23/32) (Field supply) 10 1-7/32 1915_U_I 3-17/32 22-27/32 (Suspension bolt pitch) 31/32 Dimension : inch 7-9/32 9 10 11 Refrigerant liquid line (3/8") Flare conn Refrigerant gas line (5/8") Flare conne Upper drain port (O.D. 1-1/4) Bottom drain port (O.D. 1-1/32) Suspension lug Power supply inlet (conduit size 1/2") Fresh air intake port (ø5-29/32) Flange for the flexible air outlet duct (ø Tube cover Electrical component box Flange for the air intake duct (option or field supply) 19 Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon