Download Panasonic 26PEU1U6 Data Sheet
Transcript
Split System Submittal Data System: 26PEU1U6 Indoor: S-26PU1U6 Outdoor: U-26PE1U6 Single Split System - Ceiling Recessed Heat Pumps Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15-30 Indoor-Outdoor 15-30 Indoor-Outdoor Compressor No. Used R.L. Amps - L.R. (A) DC Rotary Inverter 1 12.9 - 17.5 Outdoor Unit Fan type Dia & Length (in.) - No. used Type Drive - No. Speeds No. Poles (RPM) No. Motors (W) CFM (High) F.L. Amps (A) Propeller 18-7/64-1 DC Motor 8 - 800 1 - 90 1765 13.8 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Aluminum Fin & Copper Pipe Slit Plate - Inner Rifled 1 - 15.9 7.26 3/8" Indoor Unit Fan type Dia & Length (in.) - No. used No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (HI/Med/Lo) Indoor Sound Rating (Hi) (dB-A) F.L. Amps (A) Turbo 17-7/16-1 3 & Auto 6 - 464 1 - 40 710/530/450 38 0.7 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Drain Connection Size (in.) Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 2 - 14.9 3.69 9/32" 1-17/64" Refrigerant Lbs. - R410a Control Connection Line Length, Max (ft.) Line Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) R410A 4.19 Electric Expansion Valve Flare 165 50 (outdoor lower), 100 (outdoor higher) 3/8" 5/8" Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 11-9/64 x 32-7/8 x 33-9/32 13-5/16 x 33-55/64 x 33-55/64 34-31/32 x 39-31/32 x 16-3/32 30-23/32 x 37 x 13-3/8 Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 49 57 128 148 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 7.1 13 Performance Data @ ARI Standard Conditions (230/208V) Option Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) High Refrigerant Line Set Fresh Air Intake Airduct Extension Indoor Frame Extension Condensate Drain Pump Non-Removeable Locking Remo-con Bracket Heating Total Capacity (BTU/H) HSPF Amps (A) Max Amps (A) Power Inputs (W) Back-up Strip Heather (KW) Outdoor Sound Rating (dB-A) High 24,800 (9,500 - 24,800) 14,810 9,990 14.1 8.1 15.6/17.3 2,920/2,920 49 29,800 (8,000 - 29,800) 10.5 14.8/16.4 14.8/16.4 2,790/2,790 N/A 49 Features Controls Remote Controller Temperature Control Timer Night Setback Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Changeover Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor (Wired Remote Included) (Wireless Remote Optional) IC Thermostat 72 Hr. On/Off N/A Manual Automatic Built-In Built-In Built-In Washable, Anti-Mold Available Available Knock-out N/A Built In (Limited Vertical Lift) Available Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) 95F DB/71F WB 67 DB/57F WB 80F DB/67F WB -DB/-WB 115F DB 0F DB 75F DB/65F WB 5F DB mension : inch ir intake grille ir outlet Refrigerant liquid line 3/8") Flare connection Refrigerant gas line 5/8") Flare connection Drain connection ower supply entry (conduit size : 1/2") or discharge duct uspention bolt mounting or fresh air intake 6-3/16 Grille center7-5/32 12-1/8 4-7/8 32-9/32 (Ceiling opening) 1-4 Dimensional data 29-13/16 (Suspention bolt pitch) 15/32 1-7/8 1 Indoor Dimensions Indoor unit : 4-Way Cassette Type 26 Type 1-3/16 3-15/16 7-5/32 1-3/16 4ø1 /8 15/32 /8 8 Detail of 4-7/8 ø4 -1 2-5/32 8-11/16 3/ 32 Detail of 9 1917_X_S 33-27/32 19-11/16 15/32 1-7/8 1 -3/ 15/32 6-3/16 12-1/8 4-7/8 ø6 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 2 9/3 -2 U-36PE1U6, U-36PS1U6 ø5 2-5/16 ho le ho le 33-27/32 19-11/16 2-3/8 4-7/8 32-9/32 (Ceiling opening) 15/32 15/32 4ø1 1-4 Dimensional Data 29-13/16 (Suspention bolt pitch) 3-15/16 X 11-1/2 9-1/8 X-view 15/32 30-9/16 30-9/16 Grille center 3-15/16 3 8-11/16 Min. 19/32 8-27/32 Min. 2-15/32 14-1/2 9 4-7/8 13-11/32 30-9/16 4-7/8 32-9/32 (Ceiling opening) 22-9/32 (Suspention bolt pitch) 14-27/32 14 10-9/32 8-11/16 32 3/ -1 2-3/8 Detail of 9 15/32 ø4 2-5/32 le ho Outdoor Dimensions /8 Detail of 2 9/3 -2 8 -3/ ø6 15/32 9 8-27/32 ø5 le ho Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon 4ø1 Air intake grille Air outlet Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Drain connection Power supply entry (conduit size : 1/2") For discharge duct Suspention bolt mounting For fresh air intake 30-9/16 Dimension : inch 1917_X_S 8-27/32 15/32 30-9/16 9 33-27/32 19-11/16 15/32 30-9/16 3-15/16 14-1/2 8-11/16 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 /8 Grille center 1-4 Dimensional Data 4-7/8 ø1 X Air intake grille Air outlet Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Drain connection Power supply entry (conduit size : 1/2") For discharge duct Suspention bolt mounting For fresh air intake 4- 32-9/32 (Ceiling opening) 22-9/32 (Suspention bolt pitch) 14-27/32 Dimension : inch