Download Panasonic 26PST1U6 Data Sheet
Transcript
Split System Submittal Data System: 36PST1U6 Indoor: S-36PT1U6 Outdoor: U-36PS1U6 Single Split System - Ceiling-Suspended Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15-35 Indoor-Outdoor 15-35 Indoor-Outdoor Compressor No. Used R.L. Amps - L.R. (A) DC Rotary Inverter 1 16.4 - 17.5 Outdoor Unit Fan type Dia & Length (in.) - No. used Type Drive - No. Speeds No. Poles (RPM) No. Motors (W) CFM (High) F.L. Amps (A) Propeller 18-7/64-1 DC Motor 8 - 830 1 - 90 1942 17.3 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Aluminum Fin & Copper Pipe Slit Plate - Inner Rifled 2 - 14.1 7.26 3/8" Indoor Unit Fan type Dia & Length (in.) - No. used No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (HI/Med/Lo) Indoor Sound Rating (Hi) (dB-A) F.L. Amps (A) Centrifugal 5-29/32-4 3 & Auto 4 - 1040 1 - 100 1100/930/750 42 0.8 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Drain Connection Size (in.) Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 3 - 14.9 3.51 9/32" 1-1/4" Refrigerant Lbs. - R410a Control Connection Line Length, Max (ft.) Line Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) R410A 6.17 Electric Expansion Valve Flare 165 50 (outdoor lower), 100 (outdoor higher) 3/8" 5/8" Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 12-15/32 x 66-1/16 x 31-1/16 9-7/16 x 62-1/32 x 26-3/8 34-31/32 x 39-31/32 x 16-3/32 30-23/32 x 37 x 13-3/8 Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 84 97 143 161 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 14.8 13 Performance Data @ ARI Standard Conditions (230/208V) Option Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) High 31,200 (9,500 - 31,200) 19,800 11,400 15.1 10.0 18.2/20.1 3,840/3,840 52 Refrigerant Line Set Fresh Air Intake Condensate Drain Pump Wireless Remote Controller Non-Removeable Locking Remo-con Bracket Heating Total Capacity (BTU/H) HSPF Amps (A) Max Amps (A) Power Inputs (W) Back-up Strip Heather (KW) Outdoor Sound Rating (dB-A) High 37,600 (8,000 - 37,600) 9.1 15.9/17.6 15.9/17.6 3,350/3,350 N/A 52 Features Controls Remote Controller Temperature Control Timer Night Setback Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Changeover Self-Diagnosis Air Filter Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor (Wired Remote Included) (Wireless Remote Optional) IC Thermostat 72 Hr. On/Off N/A Manual Automatic Built-In Built-In Washable, Anti-Mold Available Knock-out Optional Accessory Optional Available Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) 95F DB/71F WB 67 DB/57F WB 115F DB 0F DB 2f 1-4 Dimensional data Indoor unit : Ceiling Type 36, 42 Type 6-5/16 5-3/16 5-3/4 4-3/4 5-9/16 3-5/32 Hole for wall-through piping (View from front) 1-31/32 6-5/16 1-3/32 Drain connection Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain (Knockout hole) 5-3/16connection2-25/32 Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake 1920_TS_I 1-3/8 61-7/32 10 or more 8-7/16 (Service space) 9-7/8 (Service space) 1-4 Dimensional Data (Service space) 9-7/8 4-1/16 5-25/32 7-7/32 Outdoor Dimensions 4-1/16 3-1/2 9-7/16 8-7/16 Front 7-3/4 10 or more 3-1/2 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 Dimension : inch 5-25/32 7-7/32 Dimension : inch Drain connection Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain connection (Knockout hole) Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake 1920_TS_I Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon 62 5-1/2 10 Air outlet or more 9-7/16 62 Front 2 ft. or more 9-7/8 26-3/8 7-3/4 10 Air outlet or more 26-3/8 1-3/8 Air intake 2 ft. or more Dimension : inch (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 59-1/4 (Suspension bolt hole pitch) 2-25/32 61-7/32 Air intake 6-5/16 12-19/32 1-4 Dimensional Data 5-1/2 6-5/16 12-19/32 (Suspension bolt hole pitch) 1-3/32 Hole for wall-through piping (View from front) (Suspension bolt hole pitch) 5-9/16 3-5/32 6-11/16 5-3/4 4-3/4 59-1/4 (Suspension bolt hole pitch) (Service space) 11-1/32 Holes in the rear side (View from front) Holes in the rear side (View from front) 9-7/8 11-1/32 5-25/32 6-11/16 7-3/4 11-1/32 3-3/8 4-1/2 7-1/4 1-31/32 11-1/32 12-7/32 4-1/16 7-7/32 12-7/32 3-15/16 3-3/8 3-1/2 3-15/16 7-31/32 7-3/4 5-15/16 6-3/32 7-31/32 7-3/4 5-15/16 6-3/32 7-3/4 Indoor Dimensions Indoor unit : Ceiling Type 36, 42 Type 4-1/2 7-1/4 Dimensional data Drain connection Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain connection (Knockout hole) Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake 1920_TS_I