Transcript
Split System Submittal Data System: 26PET1U6 Indoor: S-26PT1U6 Outdoor: U-26PE1U6 Single Split System - Ceiling-Suspended Heat Pumps Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15-30 Indoor-Outdoor 15-30 Indoor-Outdoor Compressor No. Used R.L. Amps - L.R. (A) DC Rotary Inverter 1 12.9 - 17.5 Outdoor Unit Fan type Dia & Length (in.) - No. Speeds Type Drive - No. Speeds No. Poles (RPM) No. Motors (W) CFM (High) F.L. Amps (A) Propeller 18-7/64-1 DC Motor 8 - 800 1 - 90 1765 13.8 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Aluminum Fin & Copper Pipe Slit Plate - Inner Rifled 1 - 15.9 7.26 3/8" Indoor Unit Fan type Dia & Length (in.) - No. Speeds No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (HI/Med/Lo) Indoor Sound Rating (Hi) (dB-A) F.L. Amps (A) Centrifugal 5-1/8-4 3 & Auto 4 - 1179 1 - 31 550/490/460 39 0.5 Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Drain Connection Size (in.) Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 3 - 14.9 1.81 9/32" 1-1/4" Refrigerant Lbs. - R410a Control Connection Line Length, Max (ft.) Line Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) R410A 4.19 Electric Expansion Valve Flare 165 50 (outdoor lower), 100 (outdoor higher) 3/8" 5/8" Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 9-7/16 x 54-19/32 x 31-1/16 7-17/16 x 51-3/16 x 26-3/8 34-31/32 x 39-31/32 x 16-3/32 30-23/32 x 37 x 13 3/8 Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 64 75 128 148 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 8.9 13 Performance Data @ ARI Standard Conditions (230V) Option Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) Refrigerant Line Set Fresh Air Intake Airduct Extension Indoor Frame Extension Condensate Drain Pump Non-Removeable Remo-con Bracket Heating Total Capacity (BTU/H) HSPF Amps (A) Max Amps (A) Power Inputs (W) Back-up Strip Heather (KW) Outdoor Sound Rating (dB-A) High 24,400 (9,500 - 24,400) 14,330 10,070 14.5 7.7 15.6/17.3 2,880/2,880 49 30,800 (8,000 - 30,800) 10.3 16.4/18.1 16.4/18.1 3,000/3,000 0.00/0.00 49 Features Controls Remote Controller Temperature Control Timer Night Setback Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Changeover Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor LCD Wired Type, Temp. Sensor Built in IC Thermostat 72 Hr. On/Off Built-In Manual Automatic Built-In Built-In Built-In Washable, Anti-Mold Available Knock-out N/A N/A Available Available Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) 95F DB/71F WB 67 DB/57F WB 80F DB/67F WB -DB/-WB 115F DB 0F DB 75F DB/65F WB 5F DB 1-4 Dimensional data Indoor unit : Ceiling Type 26 Type 1. Specifications intake 1-3/32 6-5/16 1 1-41 50-13/32 26-3/8 8-7/16 Front (Service space) 9-7/8 Front (Service space) 9-7/8 1-4 Dimensional Data 3-1/2 5-25/32 Outdoor Dimensions 7-7/32 Dimension : inch 4-1/16 5-25/32 Drain connection Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain connection (Knockout hole) Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake 7-7/32 Dimension : inch Drain connection Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain connection (Knockout hole) Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake 1919_THS_I 1-41 1919_THS_I SM830203-01_PAC-i_US-letter.indb41 41 2012/01 1-41 Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon 2012/01/19 22:39:24 4-1/16 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 3-1/2 5-25/32 8-7/16 3-3/4 2 ft. or more 10 or more 7-15/32 10 or more (Service space) 51-3/16 5-25/32 51-3/16 10 Air outlet or more 3-3/4 9-7/8 26-3/8 Air intake S-letter.indb41 41 1919_THS_I 1-3/8 1-3/8 50-13/32 (Service space) 1-3/8 (B) Outdoor Unit: U-26PE1U6, U-26PS1U6 U-36PE1U6, U-36PS1U6 48-7/16 (Suspension bolt hole pitch) SM830203-01_PAC-i_US-letter.indb41 41 10 Air outlet or more Hole for wall-through piping (View from front) 7-15/32 48-7/16 (Suspension bolt hole pitch) 6-5/16 1-4 Dimensional Data 6-5/16 6-5/16 12-19/32 (Suspension bolt hole pitch) 1-3/32 12-19/32 Hole for wall-through piping (View from front) 2-25/32 5-9/16 3-9/32 Drain connection for left side Refrigerant liquid line (3/8") Flare connection Refrigerant gas line (5/8") Flare connection Hole for rear side refrigerant tubing Hole for through-the-wall refrigerant tubing (ø3-15/16" hole) Hole for fresh air intake (Knockout hole) Hole for right side refrigerant tubing (Knockout hole) Hole for left side drain connection 5-3/16 2-25/32 (Knockout hole) Hole for power supply (Conduit size 1/2") Infrared rays receiver for wireless remote controller Cutting position for fresh air intake (Suspension bolt hole pitch) 5-9/16 3-9/32 5-3/16 5-3/4 Dimension :4-9/16 inch 4-23/32 5-25/32 5-3/4 4-9/16 11-1/32 Holes in the rear side (View from front) Drain connection 4-23/32 3-15/16 11-1/32 2-17/32 5-9/32 11-1/32 3-3/8 3-15/16 12-7/32 1-3/8 5-25/32 3-3/32 3-15/16 Holes in the rear side (View from front) 2 ft. or more -7/8 12-7/32 4-1/16 11-1/32 5-25/32 7-7/32 6-3/32 3-3/8 3-15/16 5-25/32 3-3/32 6-3/32 3-1/2 5-25/32 Indoor Dimensions ndoor unit : Ceiling Type 26 Type 2-17/32 5-9/32 Dimensional data 2012/01/19 22:39:24