Download NEC N8405-024F User Guide
Transcript
Information to be displayed EM card name Active/standby ID LED status EM card status EM language type Command name SHOW EM STATUS Argument <Slot number> | "ALL" (optional) The blade enclosure can supports to two EM cards. Specify the slot number of the target EM card. You can specify either 1 or 2. When you skip the slot number, the EM card you are now logging on is specified. Example of execution 1Z34AB7890(Administrator)> show em status all NEC Enclosure Manager #2 Status: Name : EM-0016355E5C2E Role : Standby UID : Off Status : OK Language : JAPANESE NEC Enclosure Manager #1 Status: Name : EM-0016355E5C10-1 Role : Active UID : Off Status : OK Language : JAPANESE Redundancy status : NORMAL 1Z34AB7890(Administrator)> Example of status of EM cards Default value Supplementary information About Redundancy status NORMAL EM cards are successfully in the redundant mode. NOT LINK UP Link with the other EM card is not achieved. DEGRADED Communication to the other card is disconnected, synchronizing the configuration between two EM cards has failed, or the EM cards use different versions of the EM firmware. FAILED There is a fatal error in communication to the other EM card, or the other EM card has failed to update the EM firmware. UNKNOWN The status of the other EM card cannot be retrieved. NOT REDUNDANT EM cards are not in the redundant mode. Configuring the language type for EM cards 223