Download Graco 3A2497BPro User's Manual
Transcript
Maintenance Maintenance Flushing • Flush before changing fluids, before fluid can dry in the equipment, at the end of the day, before storing, and before repairing equipment. 1. Turn OFF (O) the ES On-Off switch. Wait 30 seconds for the voltage to bleed off. • Flush at the lowest pressure possible. Check connectors for leaks and tighten as necessary. • Flush with a non-flammable solvent that is compatible with the fluid being dispensed and the equipment wetted parts. 2. Discharge the system voltage. See Fluid Voltage Discharge and Grounding Procedure, page 25. To reduce the risk of fire, explosion, or electric shock, turn OFF (O) the ES On-Off switch before flushing the gun. 3. Follow the Pressure Relief Procedure, page 26. 4. Remove and clean the air cap and spray tip. Follow the Fluid Voltage Discharge and Grounding Procedure, page 25, before flushing. Only flush, purge, or clean the gun with fluids that meet the following flammability requirements: • FM, FMc Approved: Material does not sustain burning in accordance with the Standard Test Method for Sustained Burning of Liquid Mixtures, ASTM D4206. • CE-EN 50059 Compliant: Materials which cannot be ignited, in any mixture with air, by an energy source of less than 500mJ. 5. Change the fluid source to non-flammable solvent. 6. Point the gun into a grounded metal pail. Flush until clean solvent flows from the gun. NOTICE Only use non-flammable solvents when flushing or cleaning equipment. 3A2497B 31