Download Fortinet FortiGate-5000 User's Manual

Transcript
The FortiGate-5005-DIST security system
FortiGate-5005-DIST interface names
FortiGate-5050 chassis
You can install one or two I/O boards in slot 1 and 2 of the FortiGate-5050 ATCA
chassis. You can also install up to three worker boards in slots 3 to 5 if two I/O
boards are being used, or four worker boards in slots 2 to 5 if one I/O board is
used. The FortiGate-5050 is a 5U chassis that contains two redundant DC power
connections that connect to -48 VDC Data Center DC power. The FortiGate-5050
chassis also includes a hot swappable cooling fan tray. For details about the
FortiGate-5050 chassis, see the FortiGate-5050 Chassis Guide.
Figure 33: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis
ACT
USB
LINK
1
OOS
LINK
LINK
ACC
3
4
5
6
STATUS
8
7
8
7
8
7
8
IPM
USB
2
3
4
5
6
ACC
2
3
4
5
6
STATUS
LINK
IPM
USB
BASE
USB
FABRIC
2
2
7
IPM
1
OOS
ACT
6
CONSOLE
ACT
LINK
5
STATUS
BASE
USB
FABRIC
ACT
4
CONSOLE
ACT
LINK
ACC
1
OOS
3
3
USB
BASE
USB
FABRIC
4
ACT
2
CONSOLE
ACT
LINK
USB
BASE
ACT
FABRIC
LINK
5
1
POWER
CONSOLE
OOS
ACC
STATUS
IPM
DATA
X1
1
X2
CONTROL
1
5
9
13
1
5
9
13
2
6
10
14
2
6
10
14
3
7
11 D 15
3
7
11 C 15
4
8
12 D 16
4
8
12 C 16
X1
X2
1
MANAGEMENT
COM 1
COM 2
2
1/2
3/4
D15/D16
C15/C16
3
4
10/100/1000 MBPS ETHERNET ACTIVITY
Hot Swap
5000SM
10/100
link/Act
10/100
link/Act
ETH0
Service
SERIAL
2
STATUS
5050SAP
SERIAL
1
RESET
IPM
ETH0 ETH1
Hot Swap
STATUS
ETH0
Service
5000SM
10/100
link/Act
10/100
link/Act
PAYLOAD OPERATION
ALARM
2
ETH0 ETH1
SMC
RESET
STATUS
SMC
1
FortiGate-5005-DIST interface names
The FortiGate-5005-DIST worker web-based manager and CLI use an internal
naming convention to name FortiGate-5005-DIST interfaces. The interface names
indicate the I/O board containing the interface and also include the I/O board front
panel interface name. The naming convention is:
port<I/O_board_number>_<I/O_board_interface_name>
where:
<I/O_board_number> is 1 for the interfaces of the primary I/O board installed in
chassis slot 1 and 2 for the interfaces of the secondary I/O board installed in
chassis slot 2. The interfaces for the secondary I/O board only appear in the
web-based manager and CLI when a secondary I/O board is installed.
<I/O_board_interface_name> is the name of the interface as shown on the
FortiController-5208 front panel.
Table 24 on page 72 shows the relationship between the names of the primary
and secondary board front panel interfaces and the interface names that appear
on the FortiGate-5005-DIST worker web-based manager and CLI.
FortiGate-5000 Series Introduction
01-30000-83466-20090108
71