The FortiGate-5005-DIST security system FortiGate-5005-DIST interface names FortiGate-5050 chassis You can install one or two I/O boards in slot 1 and 2 of the FortiGate-5050 ATCA chassis. You can also install up to three worker boards in slots 3 to 5 if two I/O boards are being used, or four worker boards in slots 2 to 5 if one I/O board is used. The FortiGate-5050 is a 5U chassis that contains two redundant DC power connections that connect to -48 VDC Data Center DC power. The FortiGate-5050 chassis also includes a hot swappable cooling fan tray. For details about the FortiGate-5050 chassis, see the FortiGate-5050 Chassis Guide. Figure 33: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis ACT USB LINK 1 OOS LINK LINK ACC 3 4 5 6 STATUS 8 7 8 7 8 7 8 IPM USB 2 3 4 5 6 ACC 2 3 4 5 6 STATUS LINK IPM USB BASE USB FABRIC 2 2 7 IPM 1 OOS ACT 6 CONSOLE ACT LINK 5 STATUS BASE USB FABRIC ACT 4 CONSOLE ACT LINK ACC 1 OOS 3 3 USB BASE USB FABRIC 4 ACT 2 CONSOLE ACT LINK USB BASE ACT FABRIC LINK 5 1 POWER CONSOLE OOS ACC STATUS IPM DATA X1 1 X2 CONTROL 1 5 9 13 1 5 9 13 2 6 10 14 2 6 10 14 3 7 11 D 15 3 7 11 C 15 4 8 12 D 16 4 8 12 C 16 X1 X2 1 MANAGEMENT COM 1 COM 2 2 1/2 3/4 D15/D16 C15/C16 3 4 10/100/1000 MBPS ETHERNET ACTIVITY Hot Swap 5000SM 10/100 link/Act 10/100 link/Act ETH0 Service SERIAL 2 STATUS 5050SAP SERIAL 1 RESET IPM ETH0 ETH1 Hot Swap STATUS ETH0 Service 5000SM 10/100 link/Act 10/100 link/Act PAYLOAD OPERATION ALARM 2 ETH0 ETH1 SMC RESET STATUS SMC 1 FortiGate-5005-DIST interface names The FortiGate-5005-DIST worker web-based manager and CLI use an internal naming convention to name FortiGate-5005-DIST interfaces. The interface names indicate the I/O board containing the interface and also include the I/O board front panel interface name. The naming convention is: port<I/O_board_number>_<I/O_board_interface_name> where: <I/O_board_number> is 1 for the interfaces of the primary I/O board installed in chassis slot 1 and 2 for the interfaces of the secondary I/O board installed in chassis slot 2. The interfaces for the secondary I/O board only appear in the web-based manager and CLI when a secondary I/O board is installed. <I/O_board_interface_name> is the name of the interface as shown on the FortiController-5208 front panel. Table 24 on page 72 shows the relationship between the names of the primary and secondary board front panel interfaces and the interface names that appear on the FortiGate-5005-DIST worker web-based manager and CLI. FortiGate-5000 Series Introduction 01-30000-83466-20090108 71