Download Emerson CP400 Data Sheet
Transcript
Bulletin 71.1:CP400 TYPE 67CP PRESSURE LOADING REGULATOR CLOSING SPRING DIAPHRAGM HEAD DIAPHRAGM LOWER CASING VALVE STEM P1562 ORIFICE EXTERNAL CONTROL LINE PLUG (DO NOT REMOVE IF UNIT IS PRESSURIZED) LEVER VALVE DISK Figure 2. Typical CP400 Regulator Cut-away View Introduction The CP400 Series pressure loaded regulators have been engineered to fit a multitude of pressure-reducing applications including light industrial and commercial installations, which include accurate control for use in pressure-factor measurement (fixed factor billing) applications. This flexibility is provided by the numerous body end connection sizes, body materials, outlet pressure settings, orifice sizes, as well as the option for internal or external pressure registration. In addition to application flexibility, the CP400 Series offers multiple overpressure protection options to meet your demands on application requirements. Overpressure Protection Options Available: • Token Relief – Provides a small capacity or token relief located in the Type 67CPR loading regulator that relieves minor overpressure caused by thermal expansion or minor nicks in the orifice or disk. • True-Monitor™ Protection – Combines the operation of a conventional two regulator wideopen monitor set into one body. Provides a second monitoring regulator to control downstream pressure. In the event of failure of the primary regulator due to damage to the lever, downstream sense line, orifice, disk, diaphragm, etc., the monitoring regulator will assume control of the downstream pressure and regulator flow. • Slam-Shut Protection – Discontinues gas service by shutting the gas off if there is an overpressure or underpressure condition. 2