Download Emerson CP200 Data Sheet

Transcript
Bulletin 71.1:CP200
Table 23. C
P200 Series Internal Registration Flow Capacities for 20 psig / 1.4 bar Setpoint
with 1% ABS Pressure Factor Accuracy (PFM Approved)
ACCURACY
SETPOINT
+ / - 1% ABS
SET RANGE
20 psig
-0.35 psi
0.35 psi
10 to 20 psig
1.4 bar
-24 mbar
24 mbar
0.69 to 1.4 bar
PART NUMBER /
COLOR
GE30200X012 /
Purple Stripe
CAPACITIES IN SCFH / Nm3/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS
Orifice Size, Inch / mm
Inlet Pressure
3/16 / 4.8
SCFH
psig
bar
25
1.7
30
2.1
1000
40
2.8
50
60
1/4 / 6.4
Nm3/h
SCFH
3/8 / 9.5
Nm3/h
SCFH
1/2 / 13
Nm3/h
SCFH
Nm3/h
Body Size: 3/4 NPT
120
3.2
2086
55.9
3038
81.4
26.8
1900
50.9
3800
102
4100
110
1600
42.9
2700
72.4
4800
129
3.4
1900
50.9
3300
88.4
5900
158
4.1
2200
59.0
4000
107
6700
180
80
5.5
2900
77.7
5100
137
100
6.9
3600
96.5
6200
166
125
8.6
4300
115
6400
172
psig
bar
25
1.7
460
12.3
1100
29.5
740
19.8
3000
80.4
30
2.1
1000
26.8
1900
50.9
3800
102
3900
105
40
2.8
1300
34.8
2700
72.4
4800
129
50
3.4
1800
48.2
3300
88.4
5900
158
60
4.1
2200
59.0
4000
107
6700
180
80
5.5
2800
75.0
5200
139
100
6.9
3300
88.4
6300
169
125
8.6
4200
113
7700
psig
bar
25
1.7
30
2.1
Body Size: 1 NPT
206
Body Size: 1-1/4 NPT
860
23.0
1900
50.9
3100
83.1
4300
115
4100
110
5600
150
40
2.8
1600
42.9
2700
72.4
6400
172
50
3.4
1700
45.6
3300
88.4
7300
196
60
4.1
2300
61.6
3600
96.5
8800
236
80
5.5
2900
77.7
5000
134
100
6.9
3400
91.1
6100
163
125
8.6
4400
118
7200
193
Blank areas indicate where maximum operating inlet pressure for a given orifice size is exceeded.