Download Dell PowerEdge M1000E Troubleshooting and Diagnostics Guide
Transcript
Equipment status TABLE 16 10 Error summary description (Continued) Error type Description too shrt Frames shorter than minimum too long Frames longer than maximum bad eof Frames with bad end-of-frame delimiters enc out Encoding error outside of frames disc c3 Class 3 frames discarded link fail Link failures (LF1 or LF2 states) loss sync Loss of synchronization loss sig Loss of signal frjt Frames rejected with F_RJT fbsy Frames busied with F_BSY Equipment status You can display status for fans, power supply, and temperature. NOTE The number of fans, power supplies, and temperature sensors depends on the switch type. For detailed specifications on these components, refer to the switch hardware reference manual. The specific output from the status commands varies depending on the switch type. Checking the temperature, fan, and power supply 1. Log in to the switch as user. 2. Enter the sensorShow command. See the Fabric OS Command Reference for details regarding the sensor numbers. 3. Check the temperature output. Look for indications of high or low temperatures. 4. Check the fan speed output. If any of the fan speeds display abnormal RPMs, replace the fan FRU. 5. Check the power supply status. If any power supplies show a status other than OK, consider replacing the power supply as soon as possible. Checking the status of the fans 1. Connect to the switch and log in as admin. 2. Enter the fanShow command: switch:admin> fanshow Fabric OS Troubleshooting and Diagnostics Guide 53-1001769-01 97