Download Dacor ERV36 User's Manual

Transcript
ERV30, ERV36, ERV48
PRV30, PRV36, PRV46
30”, 36”, 46”, 48” Wide,
Slim Raised Vent
020106
Exhaust
Duct
PLANNING
GUIDE
1/1
6"
(152mm)
Motor Cover
3" (8mm)
3/4" (19mm)
3/4" (19mm) Max. backsplash thickness
1/4" (6mm) Min. flat area
Stud wall
Support Channel
Wall board
CL
of ERV/PRV
of 1 5/8" x 16" Duct Exhaust
bottom view
CL
7/16"
(11mm)
3"
(76mm)
2 1/8" (54mm)
PRV Dimensions
1 15/16"
(49mm)
9/32" (7mm)
3/8"
(10mm)
Cooktop/Range
2 1/8" (54mm)
ERV Dimensions
top cap dimensions
2 13/16"
(71mm)
“A”
10"
(254mm)
Countertop
Stiffener
“B”
6 5/8”
(168mm)
1 5/8" x 16"
Exhaust duct
18 13/16”
(478mm)
1 5/8" x 16"
Exhaust duct
25 7/8"
30" (657mm)
(762mm)
3 1/4" x 10"
Rear
Exhaust duct
3 3/4"
(95mm)
3 1/4" x 10"
Exhaust duct
1 5/8" x 16"
Exhaust duct
6"
(152mm)
Motor
cover
48", 3 prong
grounded
power cord
3/4"
(19mm)
4"
(102mm)
Finished floor
Electrical
access panel
ATD2
1 5/8" x 16"
Exhaust duct
8 1/2"
(216mm)
erv/prv overall dimensions
Model
No.
“A” Overall Width
“B” Chassis Width
Approximate
Shipping Weight
ERV30
30” (762mm)
27 3/8” (695mm)
48 lbs.
ERV36
36” (914mm)
33 3/8” (848mm)
55 lbs.
ERV48
48” (1219mm)
43 3/8” (1102mm)
69 lbs.
PRV30
30” (762mm)
27 3/8” (695mm)
50 lbs.
PRV36
36” (914mm)
33 3/8” (848mm)
57 lbs.
PRV46
46” (1168mm)
43 3/8” (1102mm)
67 lbs.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
NOTES:
1. The Dacor custom transition ATD2 ships with each
ERV and is used for the left, right or down ducting
options. Rear ducting is designed for 3 1/4” x 10”
rectangular duct.
2. The ATD2 transitions are equivalent to 4 straight
feet.
3. It may be necessary to route or remove the cabinet
back if the minimum interior depth cannot be met.
Specifications are subject to change without notice.
See installation instructions for additional details.
8.1