Download Crestron electronic GLA-PWSI50 User's Manual
Transcript
GLA-PWSI50 Functional Summary The GLA-PWSI50 is a 50 Watt Cresnet® Power Supply designed for use with a Crestron® Green Light™ system, or anywhere a wall-mountable Cresnet power supply is needed. It is compatible with any line voltage from 100 to 240 Volts, 50 or 60 Hz. The GLA-PWSI50 mounts conveniently over the front of an electrical box, with all connections made inside the box via flying leads using terminal block connectors. An adapter plate is included for installation over a 1 or 2-gang UK or Euro style electrical box. Without the adapter plate, the GLA-PWSI50 may be mounted over a 4 inch square or 2-gang US electrical box. • • • • • • 50 Watt Cresnet power supply Powers the IPAC and other Cresnet devices Provides backup power for Crestron Green Light cabinets Compatible with 100 to 240 VAC mains Mounts to a 1 or 2-gang UK (BS 4662) or Euro (DIN 49073) electrical box Also compatible with 4 inch square or 2-gang US electrical boxes Specifications GLA-PWSI50 Specifications SPECIFICATION Output Power Output Power Ripple/Noise Power Requirements Input Enclosure Environmental Temperature Humidity Heat Dissipation DETAILS 50 Watts (2.1 Amps) @ 24 Volts DC, regulated, limited power source <1% 0.6 Amps @ 100-240 Volts AC, 50/60 Hz Metal construction, 1- or 2-gang (BS4662 UK or DIN 49073) backbox, includes adapter plate 0° to 40°C (32° to 104°F) 10% to 90% RH (non-condensing) 26 BTU/Hr Dimensions (without adapter plate) Height Width Depth 10.16 cm (4.00 in) 14.09 cm (5.55 in) 5.76 cm (2.27 in) Weight 0.54 kg (1.2 lbs) GLA-PWS50 (shown with Adapter Plate) Physical View Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Installation Guide – DOC. 6747A (2022674) 02.09 Specifications subject to change without notice. 50 Watt Cresnet Power Supply Crestron GLA-PWSI50 Industry Compliance As of the date of manufacture, the GLA-PWSI50 has been tested and found to comply with specifications for CE marking. NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 2 • Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 Installation Guide – DOC. 6747A Crestron GLA-PWSI50 50 Watt Cresnet Power Supply Application The following diagram shows a GLA-PWSI50 module in a typical application. GLA-PWSI50 in a Lighting Application Installation Guide – DOC. 6747A Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 • 3 50 Watt Cresnet Power Supply Crestron GLA-PWSI50 Connectors, Controls & Indicators Physical Description # This section provides information on the connections, controls and indicators available on the GLA-PWSI50. CONNECTORS, CONTROLS & INDICATORS 1 LINE POWER (3) 152 mm flying leads, 0.75 2 mm , line power input Line (brown), neutral (blue), and ground (green/yellow) connections 2 OUTPUT (2) 152 mm flying leads, 0.75 2 mm , Cresnet power output +24 VDC (red), G (black/white) connections Connects to “24” and “G” connections of the Cresnet control network, or directly to a 24 Volt DC powered Crestron device 3 FUSE DC output fuse, T3.15AH (5x20mm, 250V, 3.15A, timelag, ceramic cartridge). 4 24VDC LED (1) green LED, indicates 24 Volts DC output, extinguishes when fuse is blown GLA-PWSI50 Overall Dimensions 5.45 cm (2.15 in) 14.09 cm (5.55 in) DESCRIPTION 0.31 cm (0.12 in) 10.16 cm (4.00 in) 12.77 cm) (5.03 in) GLA-PWSI50 Setup Important Notes Read before installation. • • • • Permits: An electrical permit shall be obtained prior to each installation. Codes: Install in accordance with all local and national electrical codes. Wiring: Use 75°C copper wire only. Not suitable for Hazardous/Classified areas. Supplied Hardware The hardware supplied with the GLA-PWSI50 is listed in the following table. Supplied Hardware for the GLA-PWSI50 DESCRIPTION 4 • Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 PART NUMBER QUANTITY Metal, Plate, Adapter 2022080 1 Screw M3.5 x 25mm, Flat, Phil 2023756 1 Screw, 8-32, 3/8”, Pan, Phil 2007269 4 Terminal Block, 2 Position, Single Row 2023704 1 Terminal Block, 3 Position, Single Row 2023705 1 Installation Guide – DOC. 6747A Crestron GLA-PWSI50 50 Watt Cresnet Power Supply Adapter Plate Usage Preparation The GLA-PWSI50 comes with an adapter plate for mounting the power supply on a BS4662 UK backbox or a 1- or 2-gang DIN 49073 backbox. 1. Route the line and control wires from the backbox through the opening on the adapter plate as shown in the following diagram. Route Wires Through Adapter Plate (1-Gang DIN 49073 Backbox Shown) LOC. USE WITH A 1-GANG BS 4662 UK BACKBOX Top: (1) M3.5 (Not Supplied) Bottom: (1) M3.5x25 (Supplied) SCREW TYPE/QUANTITY B 2-GANG BS 4662 UK BACKBOX (2) M3.5 (Not Supplied) C 1-GANG DIN 49073 BACKBOX (2) M3 (Not Supplied) D 2-GANG DIN 49073 BACKBOX (4) M3 (Not Supplied) Hardware Hookup ADAPTER PLATE BACKBOX WARNING: RISK OF SERIOUS PERSONAL INJURY. Turn off power at the circuit breaker(s) prior to installation. Installing with power on can result in serious personal injury and damage to the device. 1. WIRES Use the included 2-position terminal block to connect the Class 2 wiring to the Cresnet network as shown in the following diagram. Connect Class 2 Wiring (High Voltage Wiring Removed for Clarity) 2. Secure the adapter plate to the backbox. Refer to the following diagram and table to determine which holes and screws to use. RED: 24 BLACK/WHITE: G Adapter Plate Holes A,B C,D 2. C,D Use the included 3-position terminal block to connect the line input wires to the line power as shown in the following diagram. Connect High Voltage Wiring (Class 2 Wiring Removed for Clarity) A D D B Installation Guide – DOC. 6747A Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 • 5 50 Watt Cresnet Power Supply Crestron GLA-PWSI50 Installation CAUTION: Only use the specified type of fuse when replacing a blown fuse. Failure to do so may cause damage to the GLA-PWSI50. The GLA-PWSI50 mounts to the adapter plate using the four included screws. Refer to the following diagram when installing the GLA-PWSI50. NOTE: Ensure that the wires will not be pinched during the installation process by pushing the wires into the backbox. FUSE TYPE: 5 x 20mm 3.15A Time Lag 5. Insert the fuse holder into the GLA-PWSI50. 6. Push in the fuse holder with a flat head screwdriver. While pushing in the fuse holder, turn the screwdriver clockwise until the fuse holder sinks in. 7. Push in the fuse holder a little further and turn the screwdriver clockwise until the fuse holder locks in place. 8. Connect power to the GLA-PWSI50. Install GLA-PWSI50 (Wires Removed for Clarity) ADAPTER PLATE GLA-PWSI50 Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. ELECTRICAL BOX COVER SCREWS, (SUPPLIED), QUAN 4 NOTE: The GLA-PWSI50 should never be installed with the label facing down. • • To ensure proper ventilation, do not cover the ventilation holes on the front of the unit. Turn on the circuit breaker after completing installation. The green LED will illuminate GLA-PWSI50 Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION LED does not turn on. Circuit breaker is off. Verify that circuit breaker is on. Fuse is blown. Check fuse and replace if necessary. GLA-PWSI50 is not properly connected. Verify wiring. Fuse Replacement Further Inquiries If the GLA-PWSI50 does not power up when it is connected to line power, the fuse may need to be replaced. The fuse holder is located on the right side of the power supply (next to the LED). To replace the fuse: If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. 1. Disconnect power to the GLA-PWSI50. 2. Use a flat-head screwdriver to push in the fuse holder. 3. While pushing in the fuse holder, turn screwdriver counterclockwise until the fuse holder pops out. 4. You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Remove the fuse from the fuse holder and insert a new fuse. 6 • Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 Installation Guide – DOC. 6747A 50 Watt Cresnet Power Supply Crestron GLA-PWSI50 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address. 2. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. 3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser. CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed. This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party. CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty. Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. Trademark Information All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation. Installation Guide – DOC. 6747A Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 • 7 50 Watt Cresnet Power Supply Crestron GLA-PWSI50 This page is intentionally left blank. 8 • Wall Mount 50 Watt Cresnet Power Supply: GLA-PWSI50 Installation Guide – DOC. 6747A