Download Bryant 548J User's Manual
Transcript
548J PACKAGED HEAT PUMP 3 TO 8.5 NOMINAL TONS Product Data C08515 (Optional hail guard shown.) the environmentally sound refrigerant This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. TABLE OF CONTENTS PAGE FEATURES AND BENEFITS . . . . . . . . . . . . . . . . . . . . 3 COOLING TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . 4 STATIC PRESSURE TABLES . . . . . . . . . . . . . . . . . . . 35 FACTORY OPTIONS & ACCESSORIES . . . . . . . . . . . 5 FAN PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . 36 ARI CAPACITY RATING . . . . . . . . . . . . . . . . . . . . . . . 8 OUTDOOR AIR INTAKE & EXHAUST PERF . . . . . 46 SOUND PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . 9 ELECTRICAL INFO . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MCA / MOCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 WEIGHTS & DIMENSIONS . . . . . . . . . . . . . . . . . . . . 18 TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . 61 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . . . . 24 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 68 548J PAGE Your Bryant Packaged Heat Pump rooftop unit (RTU) was designed by customers for customers. With no-- strip screw collars, handled access panels, and more we’ve made your unit easy to install, easy to maintain and easy to use. Easy to install: All Legacy Linet units are field-- convertible to horizontal air flow; no special adapter curbs or kits are necessary. Convertible airflow design makes it easy to adjust to unexpected job-- site complications. Lighter units make easy replacement. Bryant 3-- 8.5 ton 548J rooftops fit on existing Bryant curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Bryant accessory controls. Easy to maintain: Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our “no-- strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take refrigeration system pressure readings without affecting the condenser airflow. Easy to use: The newly designed, master terminal board by Bryant puts all your connections and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Bryant rooftops have high and low pressure switches, a filter drier, and 2” (51mm) filters standard. 2 FEATURES AND BENEFITS S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S 3-- 8.5 ton units fit on existing Bryant rooftop curbs making the utility connections the same. This saves time and money on replacement jobs. S Standardized components and layout. Standardized components and controls make service and stocking parts easier. S Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble-- shooting easier. S Crankcase heater on all models (except 04 size) provides added protection in all applications. S Precession sized suction line accumulator provide high reliability by preventing liquid from entering the compressor during low ambient conditions and reverse cycle switch over. S 4-- way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating to cooling. S Easy-- adjust, belt-- drive motor available on all sizes. Bryant provides a factory solution for most points in the fan performance table. There’s no need for field-- supplied drives or motors. S 3-- 5 ton models come standard with an Electric Drive X13, 5 speed/torque motor to provide exact performance in many applications. Belt drive motor optional. S Provisions for bottom or side condensate drain. S Capable of thru-- the-- base or thru-- the-- curb electrical routing. S Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is adjustable. S Single-- point electrical connection. S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust. S Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier. S Clean, easy to use control box. S Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design. S Color-- coded wiring. S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. S Single, central terminal board for test and wiring connections. S Fast-- access, handled, panels for easy access to the blower and blower motor, control box, and compressors. S “No-- strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit. S Exclusive, newly-- design indoor refrigerant header for easier maintenance and replacement. S Mechanical cooling (115_F to 25_F or 46_C to - 4_C) on Electro-- Mechanical (E/M) and Direct Digital Controller (DDC) (RTU-- MP controller). S 2” (51mm) disposable filters on all units. S High capacity refrigerant filter-- drier on each circuit. S High pressure switch, loss of charge switch and freeze protection adds greater unit reliability. 3 548J S Field convertible airflow (3-- 8.5 tons). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. MODEL NUMBER NOMENCLATURE 1 2 3 4 5 4 8 J P 0 ____________ 5 6 7 8 9 6 A 0 ______ 10 11 12 13 14 15 16 17 18 0 0 A 0 B 0 A A -- ________ ______ Unit Type Design Revision 548J = High Eff. Heat Pump --- = First Revision Voltage Packaging E = 460--- 3--- 60 A = Standard J = 208/230--- 1--- 60 B = LTL P = 208/230--- 3--- 60 Factory Installed Options T = 575--- 3--- 60 0A = None 548J Cooling Tons 04 = 3 Ton 07 = 6 Ton Outdoor Air Options 05 = 4 Ton 08 = 7.5 Ton A = None 06 = 5 Ton 09 = 8.5 Ton B = Temp econo w/ baro relief E = Temp econo w/ baro relief & CO2 Refrig. System Options H = Enthalpy econo w/ baro relief A = One--- Stage Cooling Models L = Enthalpy econo w/ baro relief & CO2 D = Two--- Stage Cooling Models Q = Motorized 2 pos damper Heat Level (Field---installed electric heaters available Indoor Fan Options 000 = No Heat 0 = Electric Drive X13 Motor (04--- 06) 1 = Standard static option --- Belt Drive Coil Options (Outdoor --- Indoor) 2 = Medium static option --- Belt Drive A = Al/Cu --- Al/Cu 3 = High static option --- Belt Drive B = Precoat Al/Cu --- Al/Cu C = E--- coat Al/Cu --- Al/Cu D = E--- coat Al/Cu --- E--- coat Al/Cu E = Cu/Cu --- Al/Cu F = Cu/Cu --- Cu/Cu M = Al/Cu --- Al/Cu --- Louvered Hail guards N = Precoat Al/Cu --- Al/Cu --- Louvered Hail Guards P = E coat Al/Cu --- Al/Cu --- Louvered Hail Guards Q = E coat Al/Cu --- E coat Al/Cu --- Louvered Hail Guards R = Cu/Cu --- Al/Cu --- Louvered Hail Guards S = Cu/Cu --- Cu/Cu --- Louvered Hail Guards This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. the environmentally sound refrigerant 4 FACTORY OPTIONS AND/OR ACCESSORIES Table 1 – FACTORY-- INSTALLED OPTIONS AND FIELD-- INSTALLED ACCESSORIES Cabinet Coil Options Condenser Protection Controls Economizers & Outdoor Air Dampers Economizer Sensors & IAQ Devices Electric Heat Indoor Motor & Drive Low Ambient Control Power Options Roof Curbs ITEM Thru--- the--- base electrical connections Cu/Cu indoor and/or outdoor coils Pre--- coated outdoor coils Premium, E--- coated outdoor coils Condenser coil hail guard (louvered design) Thermostats, temperature sensors, and subbases RTU--- MP Multi--- protocol controller Smoke detector (supply and/or return air) Time Guard II compressor delay control circuit Phase Monitor EconoMi$er IV (for electro--- mechanical controlled RTUs) EconoMi$er2 (for DDC controlled RTUs) Motorized 2 position outdoor--- air damper Manual outdoor--- air damper (25% and 50%) Barometric relief1 Power exhaust Single dry bulb temperature sensors2 Differential dry bulb temperature sensors2 Single enthalpy sensors2 Differential enthalpy sensors2 CO2 sensor (wall, duct, or unit mounted)2 Electric Resistance Heaters Single Point Kit Multiple motor and belt drive packages Electric Drive, X13, 5--- speed/torque (3--- 5 ton) Motormaster head pressure controller3 Convenience outlet (powered) Convenience outlet (unpowered) Non--- fused disconnect Roof curb 14” (356mm) Roof curb 24” (610mm) NOTES: 1. Included with economizer. 2. Sensors for optimizing economizer. 3. See application data for assistance. 5 FACTORY INSTALLED OPTION X X X X X FIELD INSTALLED ACCESSORY X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 548J CATEGORY FACTORY OPTIONS AND/OR ACCESSORIES (cont.) Economizer (dry--bulb or enthalpy) Non--fused Disconnect Economizers save money. They bring in fresh, outside air for ventilation; and provide cool, outside air to cool your building. This is the preferred method of low-- ambient cooling. When coupled to CO2 sensors, Economizers can provide even more savings by coupling the ventilation air to only that amount required. This OSHA-- compliant, factory-- installed, safety switch allows a service technician to locally secure power to the rooftop. 548J Economizers are available, installed and tested by the factory, with either enthalpy or dry-- bulb temperature inputs. There are also models for electromechanical as well as direct digital controllers. Additional sensors are available as accessories to optimize the economizers. Economizers include gravity controlled, barometric relief equalizes building pressure and ambient air pressures. This can be a cast effective solution to prevent building pressurization. CO2 Sensor Improves productivity and saves money by working with the economizer to intake only the correct amount of outside air for ventilation. As occupants fill your building, the CO2 sensor detects their presence through increasing CO2 levels, and opens the economizer appropriately. When the occupants leave, the CO2 levels decrease, and the sensor appropriately closes the economizer. This intelligent control of the ventilation air, called Demand Control Ventilation (DCV) reduces the overall load on the rooftop, saving money. Smoke Detectors Trust the experts. Smoke detectors make your application safer and your job easier. Bryant smoke detectors immediately shut down the rooftop unit when smoke is detected. They are available, installed by the factory, for supply air, return air, or both. Louvered Hail Guards Sleek, louvered panels protect the condenser coil from hail damage, foreign objects, and incidental contact. Convenience Outlet (powered or un--powered) Lower service bills by including a convenience outlet in your specification. Bryant will install this service feature at our factory, powered. Provides a convenient, 15 amp, 115V GFCI receptacle. Power Exhaust Pressure Relief Superior internal building pressure control. This field-- installed accessory may eliminate the need for costly, external pressure control fans. RTU--MP, Multi--protocol Controller Connect the rooftop to an existing BAS without needing complicated translators or adapter modules using the RTU-- MP controller. This new controller speaks the 4 most common building automation system languages (Bacnet, Modbus, N2, and Lonworks). Use this controller when you have an existing BAS. Time Guard II Control Circuit This accessory protects your compressor by preventing short-- cycling in the event of some other failure, prevents the compressor from restarting for 30 seconds after stopping. Not required with RTU-- MP or authorized commercial thermostats. Filter or Fan Status Switches Use these differential pressure switches to detect a filter clog or indoor fan motor failure. When used in conjunction with a compatible unit controller/thermostat, the switches will activate an alarm to warn the appropriate personnel. Motorized 2--Position Damper The new Bryant 2-- position, motorized outdoor air damper admits up to 100% outside air. Using reliable, gear-- driven technology, the 2-- position damper opens to allow ventilation air and closes when the rooftop stops, stopping unwanted infiltration. Manual OA Damper Manual outdoor air dampers are an economical way to bring in ventilation air. The dampers are available in 25% and 50% versions. 6 FACTORY OPTIONS AND/OR ACCESSORIES (cont.) Motormaster Head Pressure Controller Thru--the--Base Connections The Motormaster motor controller is a low ambient, head pressure controller kit that is designed to maintain the unit’s condenser head pressure during periods of low ambient cooling operation. This device should be used as an alternative to economizer free cooling not when economizer usage is either not appropriate or desired. The Motormaster will either cycle the outdoor-- fan motors or operate them at reduced speed to maintain the unit operation, depending on the model. Thru-- the-- base connections, available as either an accessory or as a factory option, are necessary to ensure proper connection and seal when routing wire and piping through the rooftop’s basepan and curb. These couplings eliminate roof penetration and should be considered for gas lines, main power lines, as well as control power. Some applications need larger horsepower motors, some need more airflow, and some need both. Regardless of the case, your Bryant expert has a factory installed combination to meet your application. A wide selection of motors and pulleys (drives) are available, factory installed, to handle nearly any application. Bryant offers a full-- line of field-- installed accessory heaters. The heaters are very easy to use, install and are all pre-- engineered and certified. 548J Alternate Motors and Drives Electric Heaters 7 Table 2 – ARI COOLING RATING TABLES 548J* 04A 05A 06A 07A 08D 09D NOMINAL CAPACITY (TONS) 3 4 5 6 7.5 8.5 NET COOLING CAPACITY (BTUH) 37,000 47,000 61,500 70,000 88,000 99,000 COOLING MODE TOTAL POWER (kW) 3.3 4.1 5.5 6.3 7.8 8.8 SEER EER IPLV 13.40** 13.10** 13.20** N/A N/A N/A 11.00 11.20 11.15 11.10 11.20 11.20 N/A N/A N/A N/A 12.40 12.40 548J NOTE: All AHRI ratings are based on 230, 460 and 575 volt. ** Electric Drive (direct drive) X13 5 speed/torque motor. SEER rating is 13.0 for belt drive. NA Not applicable 548J* HSPF 04A 05A 06A 07A 08D 09D 7.70 7.70 7.70 N/A N/A N/A LEGEND ARI ASHRAE COP EER HSPF IPLV SEER HEATING MODE HEATING, LOW CAPACITY COP (BTUH) 18,200 N/A 23,600 N/A 31,200 N/A 34,800 2.25 48,000 2.25 54,500 2.25 --- Air--- Conditioning, Heating and Refrigeration Institute --- American Society of Heating, Refrigerating and Air Conditioning, Inc. --- Coefficient of Performance --- Energy Efficiency Ratio --- Heating Seasonal Performance Factor --- Integrated Part Load Value --- Seasonal Energy Efficiency Ratio HEATING, HIGH CAPACITY (BTUH) 35,600 45,500 58,000 67,000 86,000 96,000 COP N/A N/A N/A 3.30 3.30 3.30 NOTES: 1. Rated and certified under ARI Standard 210/240--- 06 or 340/360--- 07, as appropriate. 2. Ratings are based on: Cooling Standard: 80_F (27_C) db, 67_F (19_C) wb indoor air temp and 95_F db outdoor air temp. IPLV Standard: 80_F (27_C) db, 67_F (19_C) wb indoor air temp and 80_F (27_C) db outdoor air temp. 3. All 548J units comply with ASHRAE 90.1 2001, 2004 Energy Standard for minimum SEER and EER requirements. 4. Where appropriate, 548J units comply with US Energy Policy Act (2005). Refer to state and local codes or visit the following website: http://bcap --- energy. org to determine if compliance with this standard pertains to your state, territory, or municipality. This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. 8 Table 3 – MINIMUM - MAXIMUM AIRFLOWS ELECTRIC HEAT UNIT 548J*04 548J*05 548J*06 548J*07 548J*08 548J*09 COOLING MINIMUM 900 1200 1500 1800 2250 2550 ELECTRIC HEATERS MINIMUM MAXIMUM 900 1500 1200 2000 1500 2500 1800 3000 2250** 3750 2250** 4250 MAXIMUM 1500 2000 2500 3000 3750 4250 **Minimum electric heat CFM exceptions : UNIT VOLTAGE HEATER kW UNIT CONFIGURATION 548J*08 548J*09 575 17.0 34.0 Horizontal or Vertical REQUIRED MINIMUM CFM 2800 2350 Table 4 – SOUND PERFORMANCE TABLE 548J* 04A 05A 06A 07A 08D 09D LEGEND dB --- Decibel A ---WEIGHTED 77 80 80 78 82 84 63 78.9 90.4 92.7 88.0 89.7 90.8 125 81.7 84.6 84.9 79.5 81.5 85.2 OUTDOOR SOUND (DB) 250 500 74.9 72.5 77.6 77.5 79 76.7 76.2 75.8 80.5 79.2 81.6 79.5 1000 70.3 74.8 73.8 72.5 77.1 78.1 2000 65.6 70.6 69.6 68.6 73.2 74.0 4000 65.6 68.0 66.4 65.7 70.2 70.4 8000 62.6 64.2 62.8 62.4 67.4 66.5 NOTES: 1. Outdoor sound data is measure in accordance with ARI standard 270--- 95. 2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure accounts for specific environmental factors which do not match individual applications. Sound power values are independent of the environment and therefore more accurate. 3. A--- weighted sound ratings filter out very high and very low frequencies, to better approximate the response of an “average” human ear. A--- weighted measurements for Bryant units are taken in accordance with 270--- 95. 9 548J UNIT 548J*05 548J*06 548J*07 1 / 1 / Scroll 9 --- 8 / --42 / --Acutrol 630 / 505 27 / 44 1 / 1 / Scroll 10 --- 3 / --42 / --Acutrol 630 / 505 27 / 44 1 / 1 / Scroll 12 --- 13 / --42 / --Acutrol 630 / 505 27 / 44 1 / 1 / Scroll 16 --- 13 / --56 / --Acutrol 630 / 505 27 / 44 Cu / Al 3/8” RTPF 3 / 15 5.5 3/4” Cu / Al 3/8” RTPF 3 / 15 5.5 3/4” Cu / Al 3/8” RTPF 4/ 15 7.3 3/4” Cu / Al 3/8” RTPF 4/ 15 7.3 3/4” Standard Static 1 phase Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Direct 1 600--- 1200 48 1 / Centrifugal 10 x 10 1 / Direct 1 600--- 1200 48 1 / Centrifugal 10 x 10 1 / Direct 1 600--- 1200 48 1 / Centrifugal 11 x 10 N/A Standard Static 3 phase 3 - 6 TONS 548J*04 Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Direct 1 600--- 1200 48 1 / Centrifugal 10 x 10 1 / Direct 1 600--- 1200 48 1 / Centrifugal 10 x 10 1 / Direct 1 600--- 1200 48 1 / Centrifugal 11 x 10 1 / Belt 1.5 878--- 1192 56 1 / Centrifugal 10 x 10 Medium Static 3 phase (COOLING) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Belt 1.5 819--- 1251 56 1 / Centrifugal 10 x 10 1 / Belt 1.5 920--- 1303 56 1 / Centrifugal 10 x 10 1 / Belt 2 1066--- 1380 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1066--- 1380 56 1 / Centrifugal 10 x 10 High Static 3 phase Table 5 – PHYSICAL DATA Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Belt 2 1035--- 1466 56 1 / Centrifugal 10 x 10 1 / Belt 2 1035--- 1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1208--- 1639 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1208--- 1639 56 1 / Centrifugal 10 x 10 Material Coil type Rows / FPI Total Face Area (ft2) Cu / Al 3/8” RTPF 2 / 17 10.7 Cu / Al 3/8” RTPF 2 / 17 12.7118055 Cu / Al 3/8” RTPF 2 / 17 15 Cu / Al 3/8” RTPF 2 / 17 21.25 Qty / Motor Drive Type Motor HP / RPM Fan diameter (in) 1 / direct 1/8 / 825 22 1 / direct 1/4 / 1100 22 1 / direct 1/4 / 1100 22 1 / direct 1/4 / 1100 22 2 / 16 x 25 x 2 1 / 20 x 24 x 1 2 / 16 x 25 x 2 1 / 20 x 24 x 1 4 / 16 x 16 x 2 1 / 20 x 24 x 1 4 / 16 x 16 x 2 1 / 20 x 24 x 1 Refrigeration System 548J # Circuits / # Comp. / Type Puronr refrig. (R--- 410A) charge per circuit A/B (lbs--- oz) Oil A/B (oz) Metering Device High--- pressure Trip / Reset (psig) Loss of Charge Pressure Trip / Reset (psig) Evap. Coil Material Coil type Rows / FPI Total Face Area (ft2) Condensate Drain Conn. Size Evap. Fan and Motor n / Centrifugal Cond. Coil Cond. fan / motor Filters RA Filter # / Size (in) OA inlet screen # / Size (in) 10 7.5 - 8.5 TONS 548J*08 548J*09 # Circuits / # Comp. / Type Puronr refrig. (R--- 410A) charge per circuit A/B (lbs--- oz) Oil A/B (oz) Metering Device High--- pressure Trip / Reset (psig) Loss of Charge Pressure Trip / Reset (psig) Evap. Coil Material Coil type Rows / FPI Total Face Area (ft2) Condensate Drain Conn. Size Evap. Fan and Motor Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 2 / 2 / Scroll 10 --- 3 / 10 --- 3 42 / 42 Accutrol 630 / 505 27 / 44 2 / 2 / Scroll 11 --- 2 / 11 --- 2 42 / 42 Accutrol 630 / 505 27 / 44 Cu / Al 3/8” RTPF 3 / 15 11.1 3/4” Cu / Al 3/8” RTPF 4 / 15 11.1 3/4” 1 / Belt 1.2 460--- 652 56 1 / Centrifugal 15 x 15 1 / Belt 1.2 460--- 652 56 1 / Centrifugal 15 x 15 Medium Static 3 phase (COOLING) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Belt 2.9 591--- 838 56 1 / Centrifugal 15 x 15 1 / Belt 2.9 591--- 838 56 1 / Centrifugal 15 x 15 High Static 3 phase Table 6 – PHYSICAL DATA Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter x Length (in) 1 / Belt 2.9 838--- 1084 56 1 / Centrifugal 15 x 15 1 / Belt 2.9 838--- 1084 56 1 / Centrifugal 15 x 15 Material Coil type Rows / FPI Total Face Area (ft2) Cu / Al 3/8” RTPF 2 / 17 25.1 Cu / Al 3/8” RTPF 2 / 17 25.1 Qty / Motor Drive Type Motor HP / RPM Fan diameter (in) 2 / direct 1/4 / 1100 22.0 2 / direct 1/4 / 1100 22.0 4 / 16 x 20 x 2 1 / 20 x 24 x 1 4 / 20 x 20 x 2 1 / 20 x 24 x 1 Cond. Coil Cond. fan / motor Filters RA Filter # / Size (in) OA inlet screen # / Size (in) 11 548J Standard Static 3 phase Refrigeration System 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 7 – ELECTRIC HEAT - ELECTRICAL DATA IFM TYPE STD DD 208/230---3---60 548J*04 548J STD DD MED BD HIGH BD 460---3---60 STD DD MED BD HIGH BD ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX NOM PWR (kW) APP PWR (kW) 101A00 102A00 103B00 104B00 102A00,102A00 101A00 102A00 103B00 104B00 105A00 101A00 102A00 103B00 104B00 105A00 101A00 102A00 103B00 104B00 105A00 106A00 107A00 108A00 109A00 106A00 107A00 108A00 109A00 106A00 107A00 108A00 109A00 4.4 6.5 8.7 10.5 13.0 4.4 6.5 8.7 10.5 16.0 4.4 6.5 8.7 10.5 16.0 4.4 6.5 8.7 10.5 16.0 6.0 8.8 11.5 14.0 6.0 8.8 11.5 14.0 6.0 8.8 11.5 14.0 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 9.8/11.9 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 12.0/14.7 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 12.0/14.7 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 12.0/14.7 5.5 8.1 10.6 12.9 5.5 8.1 10.6 12.9 5.5 8.1 10.6 12.9 3 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. 037A00 040A00 040A00 040A00 041A00 ----037A00 037A00 038A00 ------037A00 038A00 ------037A00 038A00 ------------------------- 037A00 040A00 040A00 040A00 041A00 ----037A00 037A00 038A00 ----037A00 037A00 038A00 ----037A00 037A00 038A00 ------------------------- 037A00 040A00 040A00 040A00 041A00 ----037A00 038A00 038A00 ----037A00 037A00 038A00 ----037A00 037A00 038A00 ------------------------- 040A00 040A00 040A00 040A00 041A00 --037A00 037A00 038A00 038A00 ----037A00 038A00 038A00 ----037A00 038A00 038A00 ------------------------- --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 12 IFM TYPE STD DD 208/230---3---60 548J*05 STD DD MED BD HIGH BD 460---3---60 STD DD MED BD HIGH BD ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX 101A00 103B00 102A00,102A00 103B00,103B00 104B00,104B00 102A00 103B00 105A00 104B00,104B00 102A00 103B00 105A00 104B00,104B00 102A00 103B00 105A00 104B00,104B00 106A00 108A00 109A00 108A00,108A00 106A00 108A00 109A00 108A00,108A00 106A00 108A00 109A00 108A00,108A00 NOM PWR (kW) 4.4 8.7 13.0 17.4 21.0 6.5 8.7 16.0 21.0 6.5 8.7 16.0 21.0 6.5 8.7 16.0 21.0 6.0 11.5 14.0 23.0 6.0 11.5 14.0 23.0 6.0 11.5 14.0 23.0 APP PWR (kW) 3.3/4.0 6.5/8.0 9.8/11.9 13.1/16.0 15.8/19.3 4.9/6.0 6.5/8.0 12.0/14.7 15.8/19.3 4.9/6.0 6.5/8.0 12.0/14.7 15.8/19.3 4.9/6.0 6.5/8.0 12.0/14.7 15.8/19.3 5.5 10.6 12.9 21.1 5.5 10.6 12.9 21.1 5.5 10.6 12.9 21.1 4 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. 037A00 040A00 041A00 041A00 041A00 --037A00 038A00 039A00 ----038A00 039A00 ----038A00 039A00 ------037A00 ------037A00 ------037A00 040A00 040A00 041A00 041A00 041A00 --037A00 038A00 039A00 --037A00 038A00 039A00 --037A00 038A00 039A00 ------037A00 ------037A00 ------037A00 040A00 040A00 041A00 041A00 041A00 --037A00 038A00 039A00 --037A00 038A00 039A00 --037A00 038A00 039A00 ------037A00 ------037A00 ------037A00 040A00 040A00 041A00 041A00 041A00 037A00 037A00 038A00 039A00 --037A00 038A00 039A00 --037A00 038A00 039A00 ------037A00 ------037A00 ------037A00 --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 13 548J 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA IFM TYPE STD DD 548J*06 208/230---3---60 548J STD DD MED BD HIGH BD 460---3---60 STD DD MED BD HIGH BD ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX 102A00 103B00 102A00,102A00 103B00,103B00 104B00,104B00 102A00 104B00 105A00 104B00,104B00 104B00,105A00 102A00 104B00 105A00 104B00,104B00 104B00,105A00 102A00 104B00 105A00 104B00,104B00 104B00,105A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 NOM PWR (kW) 6.5 8.7 13.0 17.4 21.0 6.5 10.5 16.0 21.0 26.5 6.5 10.5 16.0 21.0 26.5 6.5 10.5 16.0 21.0 26.5 6.0 11.5 14.0 23.0 25.5 6.0 11.5 14.0 23.0 25.5 6.0 11.5 14.0 23.0 25.5 APP PWR (kW) 4.9/6.0 6.5/8.0 9.8/11.9 13.1/16.0 15.8/19.3 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 5.5 10.6 12.9 21.1 23.4 5.5 10.6 12.9 21.1 23.4 5.5 10.6 12.9 21.1 23.4 5 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. 040A00 040A00 041A00 041A00 041A00 --038A00 038A00 039A00 039A00 --037A00 038A00 039A00 039A00 --038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 040A00 040A00 041A00 041A00 041A00 --038A00 038A00 039A00 039A00 --037A00 038A00 039A00 039A00 --038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 040A00 040A00 041A00 041A00 041A00 037A00 038A00 038A00 039A00 039A00 --038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 040A00 040A00 041A00 041A00 041A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 14 IFM TYPE 208/230--- 3--- 60 STD MED 548J*07 HIGH 460--- 3--- 60 STD MED HIGH ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX 102A00 104B00 105A00 104B00,104B00 104B00,105A00 102A00 104B00 105A00 104B00,104B00 104B00,105A00 102A00 104B00 105A00 104B00,104B00 104B00,105A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 106A00 108A00 109A00 108A00,108A00 108A00,109A00 NOM PWR (kW) 6.5 10.5 16.0 21.0 26.5 6.5 10.5 16.0 21.0 26.5 6.5 10.5 16.0 21.0 26.5 6.0 11.5 14.0 23.0 25.5 6.0 11.5 14.0 23.0 25.5 6.0 11.5 14.0 23.0 25.5 APP PWR (kW) 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 4.9/6.0 7.9/9.6 12.0/14.7 15.8/19.3 19.9/24.3 5.5 10.6 12.9 21.1 23.4 5.5 10.6 12.9 21.1 23.4 5.5 10.6 12.9 21.1 23.4 6 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. --038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 037A00 038A00 038A00 039A00 039A00 ------037A00 037A00 ------037A00 037A00 ------037A00 037A00 --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 15 548J NOM. V ---PH ---HZ UNIT Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA NOM. V ---PH ---HZ UNIT Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA IFM TYPE 548J 208/230---3---60 STD MED STD 460---3---60 548J*08 (2---STAGE COOL) HIGH MED 575---3---60 HIGH STD MED HIGH ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX 117A00 110A00 111A00 112A00 112A00,117A00 117A00 110A00 111A00 112A00 112A00,117A00 117A00 110A00 111A00 112A00 112A00,117A00 116A00 113A00 114A00 115A00 114A00,116A00 116A00 113A00 114A00 115A00 114A00,116A00 116A00 113A00 114A00 115A00 114A00,116A00 118A00 119A00 118A00 119A00 118A00 119A00 NOM PWR (kW) 10.4 16.0 24.8 32.0 42.4 10.4 16.0 24.8 32.0 42.4 10.4 16.0 24.8 32.0 42.4 13.9 16.5 27.8 33.0 41.7 13.9 16.5 27.8 33.0 41.7 13.9 16.5 27.8 33.0 41.7 17.0 34.0 17.0 34.0 17.0 34.0 APP PWR (kW) 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 12.8 15.2 25.5 30.3 38.3 12.8 15.2 25.5 30.3 38.3 12.8 15.2 25.5 30.3 38.3 17.0 34.0 17.0 34.0 17.0 34.0 7.5 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 047A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 16 IFM TYPE 208/230--- 3--- 60 STD MED STD 460--- 3--- 60 548J*09 (2---STAGE COOL) HIGH MED 575--- 3--- 60 HIGH STD MED HIGH ELECTRIC HEATER PART NUMBER CRHEATERXXXXXX 117A00 110A00 111A00 112A00 112A00,117A00 117A00 110A00 111A00 112A00 112A00,117A00 117A00 110A00 111A00 112A00 112A00,117A00 116A00 113A00 114A00 115A00 114A00,116A00 116A00 113A00 114A00 115A00 114A00,116A00 116A00 113A00 114A00 115A00 114A00,116A00 118A00 119A00 118A00 119A00 118A00 119A00 NOM PWR (kW) 10.4 16.0 24.8 32.0 42.4 10.4 16.0 24.8 32.0 42.4 10.4 16.0 24.8 32.0 42.4 13.9 16.5 27.8 33.0 41.7 13.9 16.5 27.8 33.0 41.7 13.9 16.5 27.8 33.0 41.7 17.0 34.0 17.0 34.0 17.0 34.0 APP PWR (kW) 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 7.8/9.6 12.0/14.7 18.6/22.8 24.0/29.4 31.8/38.9 12.8 15.2 25.5 30.3 38.3 12.8 15.2 25.5 30.3 38.3 12.8 15.2 25.5 30.3 38.3 17.0 34.0 17.0 34.0 17.0 34.0 8.5 TONS SINGLE POINT KIT PART NUMBER CRSINGLEXXXXXX WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O. WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E. 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 049A00 049A00 051A00 051A00 053A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 047A00 050A00 050A00 052A00 047A00 050A00 047A00 050A00 047A00 050A00 --- No Single Point Kit required LEGEND APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA --- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E. --- Power exhaust PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet 17 548J NOM. V ---PH ---HZ UNIT Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA 548J WEIGHTS & DIMENSIONS C09018 Fig. 1 -- Dimensions 548J 04--07 18 548J WEIGHTS & DIMENSIONS (cont.) C09019 Fig. 2 -- Dimensions 548J 04--07 C D B A C08337 Fig. 3 -- Service Clearance LOC A B C D DIMENSION 48” (1219 mm) 18” (457 mm) 18” (457 mm) 12” (305 mm) 42” (1067 mm) 36” (914 mm) Special 36” (914 mm) 18” (457 mm) 42” (1067 mm) 36” (914 mm) CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for sources of flue products within 10--- ft of unit fresh air intake hood Side condensate drain is used Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) 19 WEIGHTS & DIMENSIONS (cont.) ROOFCURB ACCESSORY 548J*04-07A 548J 1’ - 2” CRRFCURB001A01 [356] CRRFCURB002A01 2’ - 0” [610] UNIT SIZE C08560 Fig. 4 -- Curb Dimensions 548J 04--07 20 548J WEIGHTS & DIMENSIONS (cont.) Vertical Connections / Economizer Horizontal Connections / Economizer C08679 Fig. 5 -- Dimensions 548J 08--09 21 548J WEIGHTS & DIMENSIONS (cont.) C08680 Fig. 6 -- Dimensions 548J 08--09 C D B A C08337 Fig. 7 -- Service Clearance LOC A B C D DIMENSION 48” (1219 mm) 18” (457 mm) 18” (457 mm) 12” (305 mm) 42” (1067 mm) 36” (914 mm) Special 36” (914 mm) 18” (457 mm) 42” (1067 mm) 36” (914 mm) CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for sources of flue products within 10--- ft of unit fresh air intake hood Side condensate drain is used Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) 22 WEIGHTS & DIMENSIONS (cont.) 1’ - 2” CRRFCURB003A01 [356] CRRFCURB004A01 2’ - 0” [610] UNIT SIZE 548J08, 09 548J ROOFCURB ACCESSORY C08561 Fig. 8 -- Curb Dimensions 548J 08--09 23 APPLICATION DATA Min operating ambient temp (cooling): Sizing a rooftop In mechanical cooling mode, your Bryant rooftop can safely operate down to an outdoor ambient temperature of 25_F (-- 4_C). It is possible to provide cooling at lower outdoor ambient temperatures by using less outside air, economizers, and/or accessory low ambient kits. Bigger isn’t necessarily better. While an air conditioner needs to have enough capacity to meet the load, it doesn’t need excess capacity. In fact, having excess capacity typically results in very poor part load performance and humidity control. Max operating ambient temp (cooling): Using higher design temperatures than ASHRAE recommends for your location, adding “safety factors” to the calculated load, and rounding up to the next largest unit, are all signs of oversizing air conditioners. Oversizing can cause short-- cycling, and short cycling leads to poor humidity control, reduced efficiency, higher utility bills, drastic indoor temperature swings, excessive noise, and increased wear and tear on the air conditioner. 548J The maximum operating ambient temperature for cooling mode is 115_F (46_C). While cooling operation above 115_F (46_C) may be possible, it could cause either a reduction in performance, reliability, or a protective action by the unit’s internal safety devices. Min and max airflow (cooling mode): To maintain safe and reliable operation of your rooftop, operate within the cooling airflow limits. Operating above the max may cause blow-- off, undesired airflow noise, or airflow related problems with the rooftop unit. Operating below the min may cause problems with coil freeze-- up. Rather than oversizing an air conditioner, wise contractors and engineers “right-- size” or even slightly undersize air conditioners. Correctly sizing an air conditioner controls humidity better; promotes efficiency; reduces utility bills; extends equipment life, and maintains even, comfortable temperatures. Airflow: Low ambient applications All units are draw-- though in cooling mode. When equipped with a Bryant economizer, your rooftop unit can cool your space by bringing in fresh, cool outside air. In fact, when so equipped, accessory low-- ambient kit may not be necessary. In low ambient conditions, unless the outdoor air is excessively humid or contaminated, economizer-- based “free cooling” is the preferred less costly and energy conscious method. Outdoor air application strategies: Economizers reduce operating expenses and compressor run time by providing a free source of cooling and a means of ventilation to match application changing needs. In fact, they should be considered for most applications. Also, consider the various economizer control methods and their benefits, as well as sensors required to accomplish your application goals. Please contact your local Bryant representative for assistance. Motor limits, break horsepower (BHP): Due to Bryant’s internal unit design, air path, and specially designed motors, the full horsepower (maximum continuous BHP) band, as listed in this manual, can be used with the utmost confidence. There is no need for extra safety factors, as Bryant’s motors are designed and rigorously tested to use the entire, listed BHP range without either nuisance tripping or premature motor failure. In low ambient applications where outside air might not be desired (such as contaminated or excessively humid outdoor environments), your Bryant rooftop can operate to ambient temperatures down to - 20_F (-- 29_C) using the recommended accessory Motor master low ambient controller. 24 SELECTION PROCEDURE (WITH 548J*07 EXAMPLE) (Selection software by Bryant saves time by performing many of the steps below.) II. Determine cooling and heating loads. Given: Mixed Air Drybulb 80_F (27_C) Mixed Air Wetbulb 67_F (19_C) Ambient Drybulb 95_F (35_C) 65.0 MBH TCLoad 46.0 MBH SHCLoad 45.0 MBH HCLoad Outdoor-Air Winter Design Temp 0_F (-- 18_C) Indoor-Air Winter Design Temp 70_F (21_C) Vertical Supply Air 2100 CFM External Static Pressure 0.66 in.wg Electrical Characteristics 230-- 3-- 60 Make an initial guess at cooling tons. Refrig. tons = TCLoad / 12 MBH per ton Refrig. tons = 65.0 / 12 = 5.42 tons In this case, start by looking at the 548J*07. III. Look up the rooftop’s TC and SHC. Table 11 shows that, at the application’s supply air CFM, mixed air and ambient temperatures, the 548J*07 supplies: TCLoad = 69.0 MBH SHCLoad = 50.7 MBH. IV. V. Calculate the building Latent Heat Load. LCLoad = TCLoad - SHCLoad LCLoad = 65.0 MBH - 46.0 MBH = 19.0 MBH Select electric heat. Enter the Instantaneous and Integrated Heating Ratings, Table 17 at 2100 cfm. At 70_F (21_C) return indoor air and 0°F (-- 18_C) air entering outdoor coil, the integrated heating capacity after interpolation, is 24,300 Btuh. (Select integrated heating capacity value since deductions for outdoor-coil frost and defrosting have already been made. No correction is required.) The required heating capacity is 45,000 Btuh. Therefore, 20,700 Btuh (45,000 – 24,300) additional electric heat is required. Determine additional electric heat capacity in kW. 20,700 Btuh 3413 Btuh/kW = 6.1 kW of heat required. Enter the Electric Heating Capacities table for 548J*07 at 208/230, 3-- phase. The 6.5-kW heater at 230V most closely satisfies the heating required. 6.5 kW x 3413 = 22,185 Btuh Total unit heating capacity is 46,485 Btuh (22,185 + 24,300). VI. Calculate RTU Latent Heat Capacity LC = TC - SHC LC = 69.0 MBH - 50.7 MBH = 18.3 MBH VII. Compare RTU capacities to loads. Compare the rooftop’s SHC and LC to the building’s Sensible and Latent Heat Loads. See Notes 1 and 2. VIII. Select factory options (FIOP) Local code requires an economizer for any unit with TC larger than 65.0 MBH. IX. Calculate the total static pressure. External static pressure Sum of FIOP/Accessory static Total Static Pressure X. 0.66 in. wg +0.14 in. wg 0.80 in. wg Look up the Indoor Fan RPM & BHP. Table 34 shows, at 2100 CFM & ESP= 0.8, RPM = 1268 & BHP = 1.52 XI. Determine electrical requirements Table 25 shows the MCA and MOCP of a 548J*07 (without convenience outlet) with 6.5 kW electric heater as: MCA = 52.3 amps & MOCP = 60 amps Min. Disconnect Size: FLA = 50 & LRA = 199. Legend BHP FLA HC LC LRA MBH MCA MOCP RPM RTU SHC TC — — Break horsepower — Full load amps — Heating Capacities — Latent capacity — Lock rotor amp — (1,000) BTUH — Min. circuit ampacity — Max. over--- current protection — Revolutions per minute — Rooftop unit — Sensible heat capacity Total capacity NOTES: 1. Selecting a unit with a SHC slightly lower than the SHCLoad is often better than oversizing. Slightly lower SHC’s will help control indoor humidity, and prevent temperature swings. 2. If the rooftop’s capacity meets the Sensible Heat Load, but not the Latent Heat Load. 25 548J I. Table 8 – COOLING CAPACITIES 548J*04 58 EAT (wb) 900 Cfm 62 67 72 76 EAT (wb) 1050 Cfm 62 67 72 76 58 EAT (wb) 1200 Cfm 62 67 72 76 58 EAT (wb) 1350 Cfm 62 67 72 76 58 EAT (wb) 62 1500 Cfm 548J 58 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC THC SHC 75 31.4 27.1 33.5 24.8 38.0 21.0 42.1 16.7 ----33.7 29.1 35.0 26.9 39.4 22.4 43.3 17.2 ----35.7 30.8 36.3 28.9 40.4 23.6 44.1 17.7 ----37.5 32.4 37.6 30.7 41.2 24.8 44.7 18.0 ----38.8 33.5 38.8 31.7 41.8 25.8 45.2 18.4 ----- 85 EA (dB) 80 31.4 31.4 33.5 29.6 38.0 25.8 42.1 21.6 44.9 17.8 33.7 33.7 35.0 32.5 39.4 28 43.3 22.8 45.8 18.4 35.7 35.7 36.3 35.2 40.4 30.0 44.1 23.9 46.6 19.0 37.5 37.5 37.6 37.6 41.2 31.9 44.7 24.9 47.2 19.5 38.8 38.8 38.8 38.8 41.8 33.6 45.2 25.8 47.6 19.9 1-- STAGE COOLING 85 35.7 35.7 34.4 34.4 38.0 30.7 42.1 26.4 44.9 22.7 38.3 38.3 38.1 38.1 39.4 33.6 43.3 28.4 45.8 24.2 40.5 40.5 41.5 41.5 40.4 36.4 44.1 30.2 46.6 25.5 42.6 42.6 44.4 44.4 41.2 39 44.7 31.8 47.2 26.6 44.1 44.1 45.9 45.9 41.8 41.4 45.2 33.3 47.6 27.5 75 29.6 25.5 30.9 23.6 35.3 19.8 39.7 15.8 ----31.7 27.3 32.3 25.6 36.7 21.2 41.0 16.4 ----33.5 28.9 33.6 27.4 37.8 22.5 42.0 16.9 ----35.1 30.3 35.2 28.8 38.6 23.7 42.7 17.3 ----36.6 31.6 36.6 29.9 39.2 24.9 43.2 17.7 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 29.6 33.6 27.6 27.6 29.6 33.6 23.8 27.6 30.9 33.2 28.3 28.3 28.4 33.2 22.3 27.1 35.3 35.3 32.4 32.4 24.6 29.5 18.6 23.4 39.7 39.7 37.1 37.1 20.6 25.5 14.7 19.6 43.0 43.0 --40.5 17.1 22.0 --16.2 31.7 36.0 29.6 29.6 31.7 36.0 25.5 29.6 32.3 36.7 29.7 29.7 31.2 36.7 24.2 29.7 36.7 36.7 33.7 33.7 26.8 32.4 20.0 25.6 41.0 41.0 38.3 38.3 22.0 27.7 15.3 21.0 44.0 44.0 --41.6 17.8 23.5 --16.9 33.5 38.1 31.3 31.3 33.5 38.1 27.0 31.3 33.6 39.7 31.3 31.3 33.6 39.7 25.6 31.3 37.8 37.8 34.7 34.7 28.9 35.3 21.3 27.6 42.0 42.0 39.2 39.2 23.3 29.6 15.9 22.3 44.4 44.4 --42.3 18.3 24.7 --17.6 35.1 40.0 32.8 32.8 35.1 40.0 28.3 32.8 35.2 41.6 32.8 32.8 35.2 41.6 26.8 32.8 38.6 38.6 35.6 35.6 30.8 38.0 22.5 29.6 42.7 42.7 39.9 39.9 24.4 31.5 16.3 23.5 44.9 44.9 --42.9 18.7 25.7 --18.1 36.6 41.6 34.1 34.1 36.6 41.6 29.4 34.1 36.6 43.3 34.1 34.1 36.6 43.3 27.9 34.1 39.2 40.6 36.3 36.3 32.7 40.6 23.7 31.5 43.2 43.2 40.5 40.5 25.4 33.2 16.8 24.6 45.2 45.2 --43.2 19.1 26.7 --18.6 Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 26 3 TONS 85 31.5 31.5 31.9 31.9 32.4 28.2 37.1 24.4 40.5 21.1 33.6 33.6 35.1 35.1 33.7 31.2 38.3 26.6 41.6 22.7 35.6 35.6 37.1 37.1 34.7 34.0 39.2 28.6 42.3 24.0 37.3 37.3 38.8 38.8 36.7 36.7 39.9 30.6 42.9 25.2 38.8 38.8 40.4 40.4 39.3 39.3 40.5 32.5 43.2 26.3 75 25.6 22.0 25.7 20.9 29.4 17.3 34.0 13.6 ----27.4 23.6 27.4 22.4 30.5 18.7 35.2 14.2 ----28.9 24.9 29.0 23.6 31.4 19.9 36.0 14.7 ----30.3 26.1 30.3 24.8 32.2 21.1 36.7 15.2 ----31.5 27.2 31.6 25.8 32.8 22.3 37.2 15.6 ----- 115 EA (dB) 80 25.6 25.6 25.7 25.7 29.4 22.2 34.0 18.4 37.5 15.2 27.4 27.4 27.4 27.4 30.5 24.3 35.2 19.8 38.6 15.9 28.9 28.9 29.0 29.0 31.4 26.3 36.0 21.1 39.4 16.6 30.3 30.3 30.3 30.3 32.2 28.2 36.7 22.3 39.9 17.2 31.5 31.5 31.6 31.6 32.8 30.1 37.2 23.5 40.3 17.7 85 29.1 29.1 30.4 30.4 29.4 27.0 34.0 23.2 37.5 20.1 31.2 31.2 32.5 32.5 30.5 29.9 35.2 25.4 38.6 21.6 32.9 32.9 34.3 34.3 32.6 32.6 36.0 27.5 39.4 23.1 34.5 34.5 35.9 35.9 35.3 35.3 36.7 29.5 39.9 24.4 35.8 35.8 37.3 37.3 37.9 37.9 37.2 31.4 40.3 25.6 548J*05 58 EAT (wb) 1200 Cfm 62 67 72 76 58 EAT (wb) 1400 Cfm 62 67 72 76 58 EAT (wb) 1600 Cfm 62 67 72 76 58 EAT (wb) 1800 Cfm 62 67 72 76 58 EAT (wb) 2000 Cfm 62 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 41.7 36.5 44.1 33.7 48.8 28.2 53.2 22.3 ----44.1 38.1 45.8 36.2 50.2 29.7 54.4 22.9 ----46.1 39.2 46.9 38.2 51.2 31.1 55.3 23.2 ----47.7 39.9 47.9 40.1 52.0 32.3 55.9 23.4 ----49.1 40.4 49.1 40.4 52.6 33.4 56.4 23.6 ----- 85 EA (dB) 80 41.7 41.7 44.1 38.9 48.8 33.4 53.2 27.5 56.2 22.5 44.1 44.1 45.8 42.3 50.2 35.8 54.4 28.9 57.1 23.3 46.1 46.1 46.9 45.2 51.2 38.0 55.3 30.1 57.8 23.9 47.7 47.7 47.9 47.9 52.0 40.1 55.9 31.3 58.3 24.4 49.1 49.1 49.1 49.1 52.6 42.0 56.4 32.2 58.6 24.8 1-- STAGE COOLING 85 46.9 46.9 44.1 44.1 48.8 38.6 53.2 32.7 56.2 27.7 50.2 50.2 48.3 48.3 50.2 41.9 54.4 35.0 57.1 29.4 53.1 53.1 52.1 52.1 51.2 45.0 55.3 37.1 57.8 30.8 55.5 55.5 55.7 55.7 52.0 47.9 55.9 39.1 58.3 32.2 57.7 57.7 57.7 57.7 52.6 50.7 56.4 40.9 58.6 33.5 75 39.9 34.7 42.0 32.6 46.4 27.1 50.7 21.3 ----42.2 36.1 43.3 34.9 47.7 28.7 52.0 21.9 ----44.0 37.1 44.6 36.5 48.7 30.1 52.9 22.3 ----45.6 37.8 45.7 37.8 49.4 31.3 53.5 22.6 ----46.9 38.2 47.0 38.2 50.0 32.5 53.9 22.8 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 39.9 45.1 37.8 37.8 39.9 45.1 32.5 37.8 42.0 43.1 39.4 39.4 37.8 43.1 31.3 36.6 46.4 46.4 43.7 43.7 32.4 37.6 25.9 31.3 50.7 50.7 48.1 48.1 26.5 31.8 20.2 25.5 53.8 53.8 --51.1 21.7 27.0 --20.8 42.2 48.3 40.2 40.2 42.2 48.3 34.0 40.2 43.3 47.1 40.8 40.8 41.0 47.1 33.4 39.6 47.7 47.7 44.9 44.9 34.8 40.9 27.5 33.7 52.0 52.0 49.2 49.2 28.0 34.1 20.8 27.0 54.8 54.8 --52.0 22.5 28.6 --21.5 44.0 51.0 41.9 41.9 44.0 51.0 34.8 41.9 44.6 50.5 42.0 42.0 43.5 50.5 34.9 42.0 48.7 48.7 45.9 45.9 37.1 44.0 28.9 35.9 52.9 52.9 50.0 50.0 29.3 36.3 21.2 28.3 55.4 55.4 --52.6 23.1 30.1 --22.1 45.6 53.5 43.4 43.4 45.6 53.5 35.4 43.4 45.7 53.5 43.4 43.4 45.7 53.5 35.5 43.4 49.4 49.4 46.6 46.6 39.2 47.1 30.1 38.1 53.5 53.5 50.6 50.6 30.5 38.3 21.5 29.5 55.9 55.9 --53.1 23.6 31.5 --22.6 46.9 55.7 44.6 44.6 46.9 55.7 35.8 44.6 47.0 55.7 44.7 44.7 47.0 55.7 35.8 44.7 50.0 50.0 47.1 47.1 41.2 49.9 31.2 40.1 53.9 53.9 51.1 51.1 31.5 40.3 21.7 30.6 56.3 56.3 --53.4 24.0 32.8 --23.1 Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 27 4 TONS 85 43.1 43.1 41.9 41.9 43.7 36.6 48.1 30.8 51.1 26.1 46.4 46.4 45.8 45.8 44.9 39.9 49.2 33.2 52.0 27.7 48.9 48.9 49.0 49.0 45.9 43.0 50.0 35.4 52.6 29.2 51.3 51.3 51.4 51.4 46.6 46.0 50.6 37.4 53.1 30.6 53.5 53.5 53.5 53.5 49.0 49.0 51.1 39.4 53.4 32.0 75 35.6 30.3 36.7 29.8 40.9 24.6 45.2 18.9 ----38.0 31.7 38.0 31.7 42.0 26.2 46.2 19.5 ----39.6 32.4 39.6 32.4 42.8 27.5 46.9 19.9 ----41.0 32.8 41.0 32.9 43.5 28.7 47.4 20.1 ----42.1 33.1 42.2 33.1 44.0 29.8 47.8 20.3 ----- 115 EA (dB) 80 35.6 35.6 36.7 35.2 40.9 30.0 45.2 24.4 48.0 19.7 38.0 38.0 38.0 38.0 42.0 32.5 46.2 25.8 48.7 20.3 39.6 39.6 39.6 39.6 42.8 34.7 46.9 27.1 49.3 20.9 41.0 41.0 41.0 41.0 43.5 36.9 47.4 28.3 49.6 21.4 42.1 42.1 42.2 42.2 44.0 38.8 47.8 29.3 49.9 21.8 85 41.0 41.0 40.6 40.6 40.9 35.4 45.2 29.8 48.0 25.1 44.3 44.3 44.3 44.3 42.0 38.8 46.2 32.2 48.7 26.7 46.8 46.8 46.8 46.8 42.8 42.0 46.9 34.4 49.3 28.2 49.1 49.1 49.1 49.1 45.0 45.0 47.4 36.4 49.6 29.6 51.1 51.1 51.2 51.2 47.9 47.9 47.8 38.4 49.9 30.9 548J Table 9 – COOLING CAPACITIES Table 10 – COOLING CAPACITIES 548J*06 58 EAT (wb) 1500 Cfm 62 67 72 76 EAT (wb) 1750 Cfm 62 67 72 76 58 EAT (wb) 2000 Cfm 62 67 72 76 58 EAT (wb) 2250 Cfm 62 67 72 76 58 EAT (wb) 62 2500 Cfm 548J 58 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 52.7 46.2 55.5 42.8 61.7 35.6 68.0 27.9 ----56.0 48.4 57.6 46.4 63.6 38.0 69.9 29.0 ----58.8 50.1 59.3 49.5 65.1 40.2 71.3 29.9 ----61.0 51.3 61.1 51.3 66.2 42.3 72.3 30.6 ----63.0 52.1 63.0 52.2 67.2 44.2 73.2 31.3 ----- 85 EA (dB) 80 52.7 52.7 55.5 49.3 61.7 42.1 68.0 34.4 72.9 28.0 56.0 56.0 57.6 54.0 63.6 45.6 69.9 36.6 74.6 29.2 58.8 58.8 59.3 58.2 65.1 48.9 71.3 38.6 75.9 30.2 61.0 61.0 61.1 61.1 66.2 52.0 72.3 40.4 76.9 31.1 63.0 63.0 63.0 63.0 67.2 55.0 73.2 42.2 77.7 32.0 1-- STAGE COOLING 85 59.2 59.2 55.8 55.8 61.7 48.6 68.0 40.9 72.9 34.5 63.6 63.6 61.6 61.6 63.6 53.2 69.9 44.2 74.6 36.8 67.4 67.4 66.9 66.9 65.1 57.6 71.3 47.3 75.9 38.9 70.8 70.8 70.8 70.8 66.2 61.8 72.3 50.2 76.9 40.9 73.8 73.8 73.9 73.9 67.2 65.9 73.2 53.1 77.7 42.9 75 49.9 43.4 52.1 41.1 58.1 34.0 64.3 26.4 ----53.0 45.4 54.1 44.6 59.9 36.4 66.0 27.5 ----55.8 47.0 55.9 47.1 61.3 38.6 67.3 28.3 ----57.9 48.1 58.0 48.1 62.3 40.6 68.3 29.1 ----59.8 48.8 59.8 48.9 63.1 42.5 69.0 29.7 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 49.9 56.5 46.9 46.9 49.9 56.5 40.3 46.9 52.1 54.3 48.1 48.1 47.7 54.3 39.2 45.8 58.1 58.1 54.1 54.1 40.5 47.1 32.2 38.8 64.3 64.3 60.1 60.1 33.0 39.6 24.7 31.4 69.0 69.0 --64.5 26.6 33.2 --25.1 53.0 60.7 49.9 49.9 53.0 60.7 42.2 49.9 54.1 59.9 50.1 50.1 52.2 59.9 42.1 49.8 59.9 59.9 55.7 55.7 44.0 51.7 34.5 42.3 66.0 66.0 61.7 61.7 35.2 42.8 25.7 33.5 70.6 70.6 --65.8 27.8 35.5 --26.1 55.8 64.5 52.5 52.5 55.8 64.5 43.6 52.5 55.9 64.6 52.5 52.5 55.9 64.6 43.6 52.5 61.3 61.3 56.9 56.9 47.3 56.1 36.7 45.6 67.3 67.3 62.8 62.8 37.1 45.9 26.5 35.5 71.7 71.7 --66.6 28.7 37.6 --27.0 57.9 67.8 54.5 54.5 57.9 67.8 44.5 54.5 58.0 67.8 54.6 54.6 58.0 67.8 44.6 54.6 62.3 62.3 57.9 57.9 50.5 60.4 38.7 48.7 68.3 68.3 63.7 63.7 39.0 48.9 27.2 37.3 72.5 72.5 --67.4 29.6 39.5 --27.9 59.8 70.7 56.2 56.2 59.8 70.7 45.1 56.2 59.8 70.8 56.3 56.3 59.8 70.8 45.2 56.3 63.1 64.5 58.7 58.7 53.5 64.5 40.6 51.7 69.0 69.0 64.3 64.3 40.7 51.7 27.8 38.9 73.1 73.1 --67.9 30.5 41.5 --28.6 Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 28 5 TONS 85 53.6 53.6 52.4 52.4 54.1 45.5 60.1 38.1 64.5 31.8 57.7 57.7 57.6 57.6 55.7 50.1 61.7 41.3 65.8 34.0 61.4 61.4 61.4 61.4 56.9 54.5 62.8 44.4 66.6 36.0 64.5 64.5 64.6 64.6 58.8 58.8 63.7 47.3 67.4 37.9 67.3 67.3 67.4 67.4 62.8 62.8 64.3 50.1 67.9 39.8 75 43.6 36.8 43.7 36.7 49.6 30.2 55.5 22.8 ----46.5 38.6 46.6 38.7 51.1 32.5 56.9 23.7 ----48.8 39.7 48.8 39.8 52.2 34.6 57.8 24.5 ----50.7 40.5 50.7 40.5 53.1 36.6 58.5 25.0 ----52.3 41.0 52.4 41.0 53.8 38.3 59.0 25.5 ----- 115 EA (dB) 80 43.6 43.6 43.7 43.5 49.6 37.0 55.5 29.7 59.5 23.4 46.5 46.5 46.6 46.6 51.1 40.5 56.9 31.7 60.5 24.3 48.8 48.8 48.8 48.8 52.2 43.7 57.8 33.6 61.2 25.1 50.7 50.7 50.7 50.7 53.1 46.8 58.5 35.3 61.8 25.9 52.3 52.3 52.4 52.4 53.8 49.6 59.0 36.9 62.2 26.6 85 50.4 50.4 50.3 50.3 49.6 43.8 55.5 36.5 59.5 30.2 54.5 54.5 54.5 54.5 51.1 48.4 56.9 39.7 60.5 32.3 57.9 57.9 57.9 57.9 52.8 52.8 57.8 42.7 61.2 34.3 60.9 60.9 61.0 61.0 57.0 57.0 58.5 45.5 61.8 36.2 63.7 63.7 63.7 63.7 61.0 61.0 59.0 48.3 62.2 38.0 548J*07 58 EAT (wb) 1800 Cfm 62 67 72 76 58 EAT (wb) 2100 Cfm 62 67 72 76 58 EAT (wb) 2400 Cfm 62 67 72 76 58 EAT (wb) 2700 Cfm 62 67 72 76 58 EAT (wb) 3000 Cfm 62 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 61.1 53.3 64.1 49.6 70.8 40.7 77.4 31.1 ----64.6 55.5 66.1 53.4 72.8 43.1 79.2 31.9 ----67.4 57.0 67.8 56.5 74.3 45.3 80.4 32.6 ----69.7 58.0 69.8 58.0 75.4 47.2 81.3 33.0 ----71.7 58.7 71.7 58.7 76.4 49.0 82.0 33.4 ----- 85 EA (dB) 80 61.1 61.1 64.1 57.4 70.8 48.5 77.4 38.9 82.0 30.9 64.6 64.6 66.1 62.5 72.8 52.2 79.2 41.1 83.1 32.0 67.4 67.4 67.8 66.9 74.3 55.7 80.4 43.0 84.0 32.6 69.7 69.7 69.8 69.8 75.4 59.0 81.3 44.8 84.9 33.4 71.7 71.7 71.7 71.7 76.4 62.1 82.0 46.5 85.5 34.2 1-- STAGE COOLING 85 68.9 68.9 65.2 65.2 70.8 56.3 77.4 46.7 82.0 38.8 73.7 73.7 71.7 71.7 72.8 61.3 79.2 50.2 83.1 41.2 77.8 77.8 77.4 77.4 74.3 66.1 80.4 53.4 84.0 43.1 81.5 81.5 81.5 81.5 75.4 70.7 81.3 56.5 84.9 45.2 84.7 84.7 84.8 84.8 76.4 75.1 82.0 59.5 85.5 47.2 75 58.3 50.4 60.5 47.8 67.2 39.1 73.7 29.6 ----61.6 52.5 62.5 51.5 69.0 41.5 75.4 30.5 ----64.4 53.9 64.4 53.9 70.4 43.7 76.6 31.2 ----66.6 54.8 66.6 54.8 71.4 45.7 77.5 31.7 ----68.5 55.4 68.6 55.4 72.3 47.5 78.2 32.1 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 58.3 66.1 55.2 55.2 58.3 66.1 47.2 55.2 60.5 63.6 56.5 56.5 55.7 63.6 45.8 53.8 67.2 67.2 63.1 63.1 47.0 54.9 37.3 45.3 73.7 73.7 69.5 69.5 37.5 45.5 27.9 36.0 78.4 78.4 --73.9 29.7 37.6 --28.1 61.6 70.8 58.4 58.4 61.6 70.8 49.1 58.4 62.5 69.9 58.5 58.5 60.7 69.9 49.2 58.5 69.0 69.0 64.8 64.8 50.7 59.9 39.7 49.1 75.4 75.4 71.0 71.0 39.7 49.0 28.7 38.1 79.8 79.8 --75.1 30.7 39.9 --29.1 64.4 74.9 61.0 61.0 64.4 74.9 50.3 61.0 64.4 74.9 61.0 61.0 64.4 74.9 50.3 61.0 70.4 70.4 66.1 66.1 54.2 64.7 41.9 52.6 76.6 76.6 72.1 72.1 41.7 52.3 29.3 40.1 80.7 80.7 --76.0 31.6 42.2 --30.0 66.6 78.5 63.1 63.1 66.6 78.5 51.1 63.1 66.6 78.4 63.2 63.2 66.6 78.4 51.2 63.2 71.4 71.4 67.1 67.1 57.6 69.4 43.9 55.9 77.5 77.5 72.9 72.9 43.6 55.5 29.8 41.9 81.3 81.3 --76.6 33.0 44.9 --30.8 68.5 81.7 64.9 64.9 68.5 81.7 51.6 64.9 68.6 81.7 65.0 65.0 68.6 81.7 51.6 65.0 72.3 73.8 67.9 67.9 60.7 73.8 45.7 59 78.2 78.2 73.5 73.5 45.3 58.5 30.2 43.6 81.8 81.8 --77.1 33.0 46.3 --31.6 Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 29 6 TONS 85 63.2 63.2 61.8 61.8 63.1 53.3 69.5 44.0 73.9 36.2 67.7 67.7 67.8 67.8 64.8 58.4 71.0 47.5 75.1 38.5 71.7 71.7 71.7 71.7 66.1 63.3 72.1 50.8 76.0 40.8 75.2 75.2 75.2 75.2 67.9 67.9 72.9 54.0 76.6 43.0 78.3 78.3 78.3 78.3 72.4 72.4 73.5 57.1 77.1 45.1 75 51.8 43.7 52.1 43.4 58.6 35.3 64.9 26.0 ----54.8 45.3 54.9 45.3 60.2 37.7 66.2 26.7 ----57.3 46.4 57.3 46.4 61.4 39.9 67.1 27.2 ----59.3 47.0 59.4 47.1 62.3 41.8 67.8 27.7 ----61.0 47.3 61.0 47.4 63.0 43.4 68.2 28.0 ----- 115 EA (dB) 80 51.8 51.8 52.1 51.6 58.6 43.5 64.9 34.2 68.8 26.4 54.8 54.8 54.9 54.9 60.2 47.3 66.2 36.3 69.7 27.3 57.3 57.3 57.3 57.3 61.4 50.8 67.1 38.2 70.4 28.1 59.3 59.3 59.4 59.4 62.3 54.1 67.8 40.0 70.8 28.8 61.0 61.0 61.0 61.0 63.0 57.1 68.2 41.7 71.3 29.5 85 59.9 59.9 59.7 59.7 58.6 51.7 64.9 42.5 68.8 34.6 64.3 64.3 64.4 64.4 60.2 56.8 66.2 45.9 69.7 36.9 68.2 68.2 68.3 68.3 61.7 61.7 67.1 49.2 70.4 39.1 71.6 71.6 71.7 71.7 66.4 66.4 67.8 52.4 70.8 41.3 74.7 74.7 74.7 74.7 70.8 70.8 68.2 55.5 71.3 43.3 548J Table 11 – COOLING CAPACITIES Table 12 – COOLING CAPACITIES 548J*08 58 EAT (wb) 2250Cfm 62 67 72 76 EAT (wb) 2625 Cfm 62 67 72 76 58 EAT (wb) 3000 Cfm 62 67 72 76 58 EAT (wb) 3375 Cfm 62 67 72 76 58 EAT (wb) 62 3750 Cfm 548J 58 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 77.4 66.9 81.8 60.6 90.6 50.4 99.4 39.6 ----81.8 70.7 84.7 65.2 93.4 53.4 101.9 40.8 ----85.6 74.1 87.0 69.4 95.5 56.1 103.8 41.8 ----88.9 76.9 89.6 72.4 97.1 58.7 105.2 42.6 ----91.6 79.2 91.7 75.2 98.4 61.1 106.2 43.4 ----- 85 EA (dB) 80 77.4 77.4 81.8 72.1 90.6 62.0 99.4 51.3 105.7 42.1 81.8 81.8 84.7 78.5 93.4 66.7 101.9 54.1 107.7 43.7 85.6 85.6 87.0 84.1 95.5 71.2 103.8 56.7 109.1 44.9 88.9 88.9 89.6 88.1 97.1 75.3 105.2 59.0 110.1 45.9 91.6 91.6 91.7 91.7 98.4 79.3 106.2 61.1 111.0 46.8 2-- STAGE COOLING 85 87.8 87.8 83.7 83.7 90.6 73.5 99.4 62.9 105.7 54.5 92.8 92.8 91.7 91.7 93.4 80.1 101.9 67.5 107.7 58.1 97.2 97.2 98.9 98.9 95.5 86.2 103.8 71.6 109.1 60.6 100.9 100.9 103.8 103.8 97.1 92.0 105.2 75.3 110.1 62.8 104.0 104.0 108.3 108.3 98.4 97.5 106.2 78.8 111.0 64.9 75 74.1 64.0 77.2 58.4 86.0 48.4 94.7 37.7 ----78.0 67.5 79.9 62.9 88.6 51.4 97.1 38.9 ----81.8 70.7 82.5 66.6 90.5 54.1 98.8 39.9 ----84.9 73.4 85.1 69.7 92.1 56.7 100.0 40.7 ----87.5 75.7 87.7 71.8 93.3 59.1 101.0 41.5 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 74.1 84.1 69.8 69.8 74.1 84.1 60.3 69.8 77.2 81.4 71.9 71.9 69.9 81.4 55.9 67.4 86.0 86.0 80.8 80.8 60.0 71.6 46.2 57.8 94.7 94.7 89.5 89.5 49.4 61.0 35.8 47.4 100.8 100.8 --95.5 40.4 52.8 --38.6 78.0 88.6 74.1 74.1 78.0 88.6 64.1 74.1 79.9 89.2 75.2 75.2 76.1 89.2 60.3 73.3 88.6 88.6 83.2 83.2 64.7 78.1 49.2 62.5 97.1 97.1 91.8 91.8 52.3 65.6 36.9 50.3 102.6 102.6 --97.2 41.9 56.0 --39.9 81.8 92.9 77.6 77.6 81.8 92.9 67.1 77.6 82.5 95.4 78.0 78.0 81.0 95.4 63.1 76.8 90.5 90.5 85.1 85.1 69.2 84.2 51.9 67.0 98.8 98.8 93.4 93.4 54.8 69.8 37.9 52.9 104.0 104.0 --98.3 43.1 58.6 --41.1 84.9 96.4 80.5 80.5 84.9 96.4 69.6 80.5 85.1 100.4 81.0 81.0 85.0 100.4 65.6 79.8 92.1 92.1 86.5 86.5 73.4 90.1 54.5 71.2 100.0 100.0 94.5 94.5 57.1 73.5 38.8 55.2 105.0 105.0 --99.2 44.1 60.9 --42.1 87.5 99.4 83.0 83.0 87.5 99.4 71.8 83.0 87.7 103.5 83.1 83.1 87.7 103.5 68.1 83.1 93.3 95.6 87.7 87.7 77.3 95.6 56.9 75.2 101.0 101.0 95.4 95.4 59.2 76.9 39.5 57.3 105.8 105.8 --99.8 45.1 63.1 --43.0 Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 30 7.5 TONS 85 79.2 79.2 78.9 78.9 80.8 69.3 89.5 59.0 95.5 50.9 84.2 84.2 86.2 86.2 83.2 75.9 91.8 63.6 97.2 53.9 88.0 88.0 90.5 90.5 85.1 82.1 93.4 67.8 98.3 56.4 91.4 91.4 94.1 94.1 87.9 87.9 94.5 71.6 99.2 58.7 94.3 94.3 98.1 98.1 93.4 93.4 95.4 75.0 99.8 60.8 75 65.2 56.4 66.6 53.2 75.1 43.9 83.8 33.6 ----69.5 60.1 69.8 56.8 77.4 46.8 86.0 34.8 ----72.9 63.0 73.3 59.6 79.0 49.5 87.5 35.8 ----75.7 65.5 75.8 62.1 80.3 52.0 88.5 36.6 ----78.1 67.6 78.2 64.1 81.5 54.5 89.3 37.4 ----- 115 EA (dB) 80 65.2 65.2 66.6 64.5 75.1 55.4 83.8 45.2 89.7 36.5 69.5 69.5 69.8 69.2 77.4 60.2 86.0 48.1 91.2 37.9 72.9 72.9 73.3 72.6 79.0 64.6 87.5 50.7 92.2 39.0 75.7 75.7 75.8 75.8 80.3 68.7 88.5 53.1 92.9 40.0 78.1 78.1 78.2 78.2 81.5 72.7 89.3 55.2 93.5 40.9 85 74.1 74.1 75.9 75.9 75.1 67.0 83.8 56.8 89.7 48.8 78.9 78.9 81.6 81.6 77.4 73.5 86.0 61.5 91.2 51.6 82.8 82.8 85.6 85.6 79.6 79.6 87.5 65.7 92.2 54.2 86.0 86.0 89.5 89.5 85.4 85.4 88.5 69.5 92.9 56.4 88.7 88.7 92.3 92.3 90.9 90.9 89.3 73.0 93.5 58.4 548J*09 58 EAT (wb) 2550 Cfm 62 67 72 76 58 EAT (wb) 2975 Cfm 62 67 72 76 58 EAT (wb) 3400 Cfm 62 67 72 76 58 EAT (wb) 3825 Cfm 62 67 72 76 58 EAT (wb) 4250 Cfm 62 67 72 76 LEGEND --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 91.1 79.4 96.0 72.7 106.4 60.4 117.3 47.4 ----96.5 84.1 98.2 78.1 109.5 64.1 120.6 49.1 ----101.0 88.0 102.3 82.9 112.1 67.7 123.0 50.5 ----104.5 91.1 105.0 86.9 114.1 71.2 124.9 51.9 ----108.6 94.6 109.0 89.5 115.6 74.3 126.4 53.1 ----- 85 EA (dB) 80 91.1 91.1 96.0 86.0 106.4 73.8 117.3 60.9 126.1 50.3 96.5 96.5 98.2 93.6 109.5 79.6 120.6 64.7 129.2 52.3 101.0 101.0 102.3 99.7 112.1 85.3 123.0 68.2 131.5 54.1 104.5 104.5 105.0 105.0 114.1 90.8 124.9 71.5 133.3 55.7 108.6 108.6 109.0 107.9 115.6 95.9 126.4 74.6 134.6 57.2 2-- STAGE COOLING 85 102.9 102.9 99.4 99.4 106.4 87.2 117.3 74.4 126.1 64.3 109.0 109.0 109.0 109.0 109.5 95.2 120.6 80.3 129.2 68.4 114.0 114.0 116.5 116.5 112.1 102.9 123.0 85.9 131.5 72.1 118.0 118.0 123.0 123.0 114.1 110.4 124.9 91.1 133.3 75.6 122.6 122.6 126.4 126.4 117.4 117.4 126.4 96.1 134.6 78.8 75 86.4 75.2 89.2 69.6 100.4 57.7 111.2 45.1 ----91.7 79.9 92.9 75.1 103.0 61.4 114.2 46.7 ----96.7 84.2 96.9 79.7 105.5 65.1 116.5 48.2 ----99.8 86.9 100.3 83.0 107.4 68.5 118.2 49.5 ----102.7 89.5 103.4 85.6 108.9 71.7 119.7 50.8 ----- AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 86.4 97.5 81.2 81.2 86.4 97.5 70.8 81.2 89.2 96.4 83.0 83.0 83.0 96.4 66.7 80.0 100.4 100.4 92.9 92.9 71.1 84.5 54.7 68.1 111.2 111.2 104.3 104.3 58.5 72.0 42.4 55.9 119.9 119.9 --113.0 48.0 61.8 --45.6 91.7 103.5 86.7 86.7 91.7 103.5 75.5 86.7 92.9 105.4 87.0 87.0 90.2 105.4 71.3 85.9 103.0 103.0 96.3 96.3 76.9 92.5 58.7 74.3 114.2 114.2 107.3 107.3 62.3 77.9 44.1 59.7 122.9 122.9 --115.7 50.0 65.8 --47.6 96.7 109.1 90.9 90.9 96.7 109.1 79.2 90.9 96.9 112.5 90.7 90.7 96.1 112.5 75.1 90.7 105.5 105.5 98.4 98.4 82.7 100.2 62.2 79.8 116.5 116.5 109.4 109.4 65.8 83.5 45.6 63.2 124.9 124.9 --117.7 51.8 69.7 --49.4 99.8 112.6 94.4 94.4 99.8 112.6 82.3 94.4 100.3 117.5 93.4 93.4 100.3 117.5 77.4 93.4 107.4 107.6 99.4 99.4 88.1 107.6 65.4 85.0 118.2 118.2 111.0 111.0 69.1 88.7 47.0 66.6 126.5 126.5 --119.2 53.5 73.3 --51.1 102.7 115.9 97.4 97.4 102.7 115.9 84.9 97.4 103.4 121.2 97.5 97.5 103.4 121.2 80.7 97.5 108.9 114.7 101.6 101.6 93.2 114.7 68.7 90.1 119.7 119.7 112.3 112.3 72.3 93.8 48.2 69.8 127.8 127.8 --120.3 55.0 76.6 --52.6 Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 31 8.5 TONS 85 91.7 91.7 93.4 93.4 92.9 81.6 104.3 69.4 113.0 59.4 97.9 97.9 100.5 100.5 96.3 89.8 107.3 75.3 115.7 63.5 102.6 102.6 106.3 106.3 98.4 97.3 109.4 80.8 117.7 67.2 106.6 106.6 109.5 109.5 104.6 104.6 111.0 86.2 119.2 70.8 110.0 110.0 114.2 114.2 111.4 111.4 112.3 91.4 120.3 74.1 75 75.7 66.0 76.5 62.4 86.0 51.8 97.0 39.7 ----80.5 70.1 80.6 66.7 87.6 55.3 99.5 41.3 ----84.9 74.0 84.6 70.0 90.8 59.2 101.6 42.8 ----87.9 76.6 87.3 72.3 92.0 62.4 103.1 44.2 ----90.8 79.1 91.3 75.6 93.6 65.6 104.2 45.4 ----- 115 EA (dB) 80 75.7 75.7 76.5 75.2 86.0 65.2 97.0 53.1 105.6 43.0 80.5 80.5 80.6 80.6 87.6 70.9 99.5 56.9 108.1 45.0 84.9 84.9 84.6 84.6 90.8 76.7 101.6 60.4 109.9 46.8 87.9 87.9 87.3 87.3 92.0 81.9 103.1 63.8 111.2 48.5 90.8 90.8 91.3 91.3 93.6 86.8 104.2 67.0 112.3 50.0 85 85.5 85.5 88.0 88.0 86.0 78.6 97.0 66.6 105.6 56.7 90.9 90.9 94.5 94.5 87.6 86.5 99.5 72.5 108.1 60.8 95.8 95.8 99.1 99.1 94.2 94.2 101.6 78.1 109.9 64.6 99.2 99.2 102.3 102.3 101.3 101.3 103.1 83.4 111.2 68.1 102.5 102.5 106.9 106.9 108.1 108.1 104.2 88.5 112.3 71.5 548J Table 13 – COOLING CAPACITIES Table 14 – HEATING CAPACITIES 3 TONS 548J*04 RETURN AIR (°F db) CFM (STANDARD AIR) 900 55 1200 1500 900 70 1200 548J 1500 900 80 1200 1500 Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh) ---10 0 10 17 30 40 47 50 60 11.6 10.7 12.0 11.1 12.6 11.6 9.8 9.0 10.1 9.3 10.8 10.0 8.3 7.7 8.6 8.0 9.3 8.6 15.1 13.9 15.5 14.3 16.3 15.0 13.3 12.3 13.8 12.7 14.6 13.4 11.9 10.9 12.4 11.4 13.2 12.1 18.9 17.4 19.4 17.8 20.2 18.5 17.2 15.7 17.7 16.3 18.6 17.1 15.7 14.4 16.3 15.0 17.2 15.8 21.7 19.8 22.3 20.3 23.1 21.1 20.0 18.2 20.7 18.8 21.5 19.6 18.6 16.9 19.3 17.6 20.2 18.4 27.6 24.2 28.4 24.9 29.5 25.8 25.6 22.5 26.6 23.3 27.7 24.3 24.1 21.2 25.1 22.0 26.2 23.0 32.7 32.7 33.5 33.5 34.2 34.2 30.4 30.4 31.7 31.7 33.0 33.0 29.0 29.0 30.2 30.2 31.4 31.4 36.0 36.0 36.7 36.7 37.5 37.5 34.5 34.5 35.4 35.4 36.4 36.4 32.7 32.7 34.3 34.3 35.5 35.5 37.1 37.1 37.8 37.8 38.6 38.6 35.5 35.5 36.5 36.5 37.4 37.4 34.1 34.1 35.4 35.4 36.5 36.5 41.8 41.8 42.7 42.7 43.5 43.5 40.2 40.2 41.2 41.2 42.0 42.0 39.0 39.0 40.1 40.1 41.1 41.1 Table 15 – HEATING CAPACITIES 4 TONS 548J*05 RETURN AIR (°F db) CFM (STANDARD AIR) 1200 55 1600 2000 1200 70 1600 2000 1200 80 1600 2000 LEGEND Capacity Int. Cap. rh db --------- Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh) ---10 0 10 17 30 40 47 50 60 17.5 16.2 17.5 16.2 18.5 17.1 15.8 14.6 15.9 14.7 17.0 15.7 14.2 13.1 14.4 13.3 15.5 14.3 22.0 20.2 22.1 20.3 23.1 21.3 20.3 18.7 20.5 18.9 21.7 20.0 18.8 17.3 19.1 17.6 20.3 18.7 26.6 24.4 26.7 24.5 27.8 25.5 25.0 22.9 25.3 23.2 26.5 24.3 23.5 21.6 23.9 22.0 25.2 23.1 30.0 27.3 30.2 27.5 31.3 28.6 28.3 25.8 28.7 26.1 29.9 27.3 26.9 24.6 27.4 25.0 28.7 26.1 36.8 32.2 37.3 32.7 38.7 33.9 35.0 30.6 35.6 31.2 36.9 32.4 33.6 29.4 34.2 30.0 35.6 31.2 42.6 42.6 43.5 43.5 44.9 44.9 40.5 40.5 41.3 41.3 42.9 42.9 39.0 39.0 39.8 39.8 41.4 41.4 47.1 47.1 47.9 47.9 49.1 49.1 44.7 44.7 45.8 45.8 47.3 47.3 43.2 43.2 44.2 44.2 45.9 45.9 48.9 48.9 49.8 49.8 50.9 50.9 46.7 46.7 47.8 47.8 49.1 49.1 45.1 45.1 46.1 46.1 47.8 47.8 55.3 55.3 56.1 56.1 57.1 57.1 53.0 53.0 53.9 53.9 55.2 55.2 51.4 51.4 52.4 52.4 53.8 53.8 Instantaneous Capacity (1000 Btuh) includes indoor fan motor heat @ARI static conditions Integrated Capacity is Instantaneous Capacity minus the effects of frost on the outdoor coil and the heat required to defrost Relative Humidity Dry Bulb 32 Table 16 – HEATING CAPACITY 5 TONS 548J*06 CFM (STANDARD AIR) 1500 55 2000 2500 1500 70 2000 2500 1500 80 2000 2500 Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F DB AT 70% RH) ---10 0 10 17 30 40 47 50 60 22.7 21.0 22.8 21.1 24.2 22.4 19.9 18.4 20.1 18.6 21.5 19.9 17.6 16.3 17.8 16.5 19.3 17.8 28.3 26.1 28.5 26.2 30.0 27.6 25.8 23.7 26.1 24.0 27.6 25.4 23.7 21.9 24.1 22.2 25.6 23.6 34.2 31.4 34.4 31.6 35.9 33.0 31.9 29.3 32.3 29.6 33.8 31.1 30.0 27.6 30.5 28.0 32.1 29.4 38.6 35.2 38.9 35.4 40.4 36.8 36.3 33.1 36.7 33.5 38.3 35.0 34.6 31.5 35.1 32.0 36.8 33.5 47.4 41.5 47.9 42.0 49.6 43.5 45.2 39.6 45.8 40.1 47.5 41.6 43.5 38.1 44.3 38.8 46.0 40.3 54.3 54.3 55.3 55.3 56.9 56.9 51.7 51.7 52.9 52.9 54.7 54.7 50.2 50.2 51.2 51.2 53.1 53.1 60.0 60.0 60.9 60.9 62.3 62.3 57.6 57.6 58.4 58.4 60.4 60.4 55.7 55.7 56.6 56.6 58.8 58.8 62.6 62.6 63.1 63.1 64.4 64.4 60.0 60.0 61.0 61.0 62.7 62.7 58.2 58.2 59.4 59.4 61.1 61.1 70.3 70.3 70.9 70.9 72.0 72.0 67.9 67.9 68.8 68.8 70.2 70.2 66.1 66.1 67.2 67.2 68.8 68.8 Table 17 – HEATING CAPACITY 6 TONS 548J*07 RETURN AIR (°F DB) CFM (STANDARD AIR) 1800 55 2400 3000 1800 70 2400 3000 1800 80 2400 3000 LEGEND Capacity Int. Cap. rh db --------- Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F DB AT 70% RH) ---10 0 10 17 30 40 47 50 60 22.4 20.7 24.6 22.7 27.4 25.3 17.7 16.4 19.9 18.4 22.8 21.1 13.9 12.8 16.0 14.8 18.8 17.4 29.8 27.4 32.1 29.5 35.0 32.2 25.5 23.5 27.9 25.7 30.9 28.4 21.9 20.2 24.4 22.5 27.4 25.2 37.1 34.1 39.6 36.3 42.5 39.0 33.2 30.5 35.8 32.9 38.9 35.7 29.9 27.4 32.6 29.9 35.8 32.8 42.5 38.8 45.1 41.1 48.2 43.9 38.6 35.2 41.4 37.7 44.5 40.6 35.5 32.3 38.4 35.0 41.6 37.9 53.5 46.9 56.4 49.4 59.5 52.1 49.5 43.4 52.7 46.2 56.1 49.2 46.2 40.5 49.6 43.5 53.1 46.6 62.4 62.4 65.6 65.6 68.6 68.6 58.5 58.5 62.0 62.0 65.5 65.5 55.3 55.3 59.0 59.0 62.7 62.7 68.6 68.6 71.5 71.5 74.5 74.5 65.0 65.0 68.4 68.4 71.7 71.7 62.0 62.0 65.8 65.8 69.4 69.4 71.2 71.2 74.2 74.2 77.2 77.2 67.7 67.7 71.0 71.0 74.4 74.4 64.9 64.9 68.6 68.6 72.1 72.1 80.3 80.3 83.8 83.8 86.8 86.8 76.5 76.5 80.3 80.3 83.9 83.9 73.7 73.7 77.5 77.5 81.4 81.4 Instantaneous Capacity (1000 Btuh) includes indoor fan motor heat @ARI static conditions Integrated Capacity is Instantaneous Capacity minus the effects of frost on the outdoor coil and the heat required to defrost Relative Humidity Dry Bulb 33 548J RETURN AIR (°F DB) Table 18 – HEATING CAPACITY 7.5 TONS 548J*08 RETURN AIR (°F db) CFM (STANDARD AIR) 2250 55 3000 3750 2250 70 3000 548J 3750 2250 80 3000 3750 Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh) ---10 25.9 23.9 27.4 25.3 31.0 28.6 22.5 20.8 24.1 22.3 27.8 25.7 0 34.6 31.8 36.2 33.4 40.0 36.8 31.5 29.0 33.3 30.6 37.1 34.1 10 17 30 40 47 50 60 46.9 43.1 53.5 48.7 43.6 40.0 45.5 41.8 49.3 45.3 40.7 37.3 42.7 39.2 46.6 42.8 58.9 53.7 50.2 45.7 52.2 47.6 56.1 51.1 47.3 43.1 49.5 45.2 53.5 48.8 66.3 58.1 68.5 60.0 72.5 63.5 62.7 55.0 65.1 57.0 69.1 60.6 60.1 52.6 62.5 54.8 66.7 58.4 77.2 77.2 80.2 80.2 84.6 84.6 73.0 73.0 75.9 75.9 80.4 80.4 70.3 70.3 73.1 73.1 77.5 77.5 86.2 86.2 89.8 89.8 94.5 94.5 81.4 81.4 85.0 85.0 89.8 89.8 78.2 78.2 81.6 81.6 86.4 86.4 89.4 89.4 93.1 93.1 97.6 97.6 84.5 84.5 88.2 88.2 93.2 93.2 81.2 81.2 84.7 84.7 89.7 89.7 103.3 103.3 106.7 106.7 110.6 110.6 98.0 98.0 102.1 102.1 106.5 106.5 94.3 94.3 98.6 98.6 103.4 103.4 Table 19 – HEATING CAPACITY 8.5 TONS 548J*09 RETURN AIR (°F db) CFM (STANDARD AIR) 2550 55 3400 4250 2550 70 3400 4250 2550 80 3400 4250 Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. Capacity Int. Cap. TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh) ---10 0 10 17 30 40 47 50 60 33.1 30.7 34.4 31.8 38.0 35.2 29.0 26.8 30.3 28.0 34.0 31.5 25.3 23.4 26.6 24.6 30.4 28.1 42.7 39.3 44.0 40.5 47.7 43.9 38.6 35.5 40.2 37.0 44.0 40.5 35.0 32.2 36.7 33.8 40.6 37.4 52.7 48.3 54.2 49.8 58.0 53.2 48.6 44.6 50.4 46.3 54.4 50.0 45.2 41.5 47.2 43.3 51.2 47.0 60.0 54.7 61.8 56.4 65.8 60.0 55.9 51.0 58.0 52.9 62.1 56.6 52.6 48.0 54.8 50.0 59.0 53.8 75.6 66.2 77.5 67.9 81.5 71.4 70.7 61.9 73.5 64.4 77.8 68.2 67.1 58.8 69.8 61.2 74.4 65.1 87.4 87.4 89.9 89.9 94.2 94.2 83.5 83.5 86.1 86.1 90.5 90.5 80.0 80.0 83.0 83.0 87.7 87.7 97.5 97.5 100.2 100.2 103.9 103.9 93.1 93.1 96.5 96.5 100.5 100.5 90.0 90.0 93.1 93.1 97.7 97.7 100.6 100.6 103.1 103.1 106.6 106.6 96.2 96.2 99.2 99.2 103.3 103.3 93.2 93.2 96.2 96.2 100.7 100.7 113.8 113.8 115.7 115.7 118.2 118.2 109.5 109.5 111.9 111.9 115.2 115.2 106.5 106.5 109.2 109.2 112.8 112.8 --- Indicates operation not permissible LEGEND Capacity --- Instantaneous Capacity (1000 Btuh) includes indoor fan motor heat @ARI static conditions Int. Cap. --- Integrated Capacity is Instantaneous Capacity minus the effects of frost on the outdoor coil and the heat required to defrost rh --- Relative Humidity db --- Dry Bulb 34 Table 20 – STATIC PRESSURE ADDERS (Factory Options and/or Accessories) Economizer CFM (in. wg) Vertical Economizer Horizontal Economizer 600 800 1000 3 --- 6 TONS 1250 1500 1750 2000 2250 2500 2750 3000 0.01 0.02 0.04 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.26 0.02 0.03 0.04 0.06 0.08 0.10 0.13 0.15 0.18 0.23 0.28 2250 2500 2750 3000 3250 7.5 --- 8.5 TONS 3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000 0.06 0.08 0.09 0.12 0.13 0.15 0.17 0.20 0.22 0.25 0.29 0.33 0.36 0.40 0.44 0.48 0.08 0.10 0.13 0.15 0.18 0.21 0.25 0.28 0.30 0.34 0.39 0.43 0.47 0.51 0.56 0.60 1800 2000 2200 2400 2600 548J CFM (in. wg) Vertical Economizer Horizontal Economizer Electric Heaters CFM (in. wg) 1 Electric Heater Module 2 Electric Heater Modules CFM (in. wg) 1 Electric Heater Module 2 Electric Heater Modules 3 --- 6 TONS 1400 1600 600 900 1200 0.03 0.05 0.07 0.09 0.09 0.10 0.11 0.11 0.12 0.13 0.13 0.15 0.16 0.16 0.16 0.17 0.17 0.17 0.18 0.18 2250 2500 2750 3000 3250 7.5 --- 8.5 TONS 3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000 0.03 0.04 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.18 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.15 0.16 0.17 0.19 0.20 General fan performance notes: 1. Interpolation is permissible. Do not extrapolate. 2. External static pressure is the static pressure difference between the return duct and the supply duct plus the static pressure caused by any FIOPs or accessories. 3. Tabular data accounts for pressure loss due to clean filters, unit casing, and wet coils. Factory options and accessories may add static pressure losses, as shown in Table 20. Selection software is available, through your salesperson, to help you select the best motor/drive combination for your application. 4. The Fan Performance tables offer motor/drive recommendations. In cases when two motor/drive combinations would work, Bryant recommended the lower horsepower option. 5. For information on the electrical properties of Bryant motors, please see the Electrical information section of this book. 6. For more information on the performance limits of Bryant motors, see the application data section of this book. 35 FAN PERFORMANCE Table 21 – 548J*04 ELECTRIC DRIVE, X13 MOTOR, 3 TON HORIZONTAL SUPPLY SPEED (TORQUE) TAP 548J 1 2 3 4 5 CFM ESP BHP 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 0.70 0.60 0.50 0.39 0.29 0.21 0.12 0.03 --0.85 0.76 0.66 0.55 0.46 0.36 0.27 0.17 0.07 1.02 0.94 0.86 0.79 0.71 0.61 0.51 0.40 0.29 1.12 1.06 1.00 0.95 0.89 0.80 0.70 0.57 0.46 1.18 1.14 1.10 1.06 1.02 0.98 0.94 0.90 0.87 0.31 0.30 0.29 0.27 0.26 0.24 0.23 0.21 --0.37 0.36 0.36 0.34 0.34 0.32 0.31 0.29 0.27 0.44 0.45 0.45 0.45 0.45 0.44 0.43 0.41 0.39 0.49 0.50 0.52 0.53 0.54 0.53 0.52 0.50 0.49 0.52 0.54 0.56 0.58 0.60 0.63 0.65 0.68 0.71 Table 22 – 548J*04 ELECTRIC DRIVE, X13 MOTOR, 3 TON VERTICAL SUPPLY SPEED (TORQUE) TAP 1 2 3 4 5 36 CFM ESP BHP 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 900 975 1050 1125 1200 1275 1350 1425 1500 0.44 0.35 0.24 0.15 0.08 0.02 ------0.64 0.53 0.42 0.32 0.24 0.15 0.07 ----0.93 0.80 0.68 0.57 0.47 0.35 0.26 0.13 0.08 1.04 0.92 0.80 0.71 0.62 0.52 0.43 0.27 0.22 1.10 1.00 0.90 0.82 0.75 0.70 0.67 0.60 0.62 0.22 0.21 0.20 0.19 0.19 0.18 ------0.30 0.29 0.28 0.27 0.26 0.25 0.24 ----0.42 0.41 0.39 0.38 0.37 0.36 0.34 0.33 0.32 0.47 0.46 0.45 0.45 0.45 0.44 0.44 0.42 0.41 0.50 0.49 0.49 0.50 0.51 0.54 0.57 0.60 0.64 FAN PERFORMANCE (cont.) SPEED (TORQUE) TAP 1 2 3 4 5 CFM ESP BHP 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 0.75 0.63 0.48 0.33 0.19 0.05 ------0.97 0.88 0.77 0.64 0.50 0.36 0.21 0.06 --0.98 0.91 0.82 0.71 0.58 0.45 0.31 0.16 0.03 0.98 0.92 0.86 0.79 0.70 0.62 0.52 0.37 0.21 1.02 0.97 0.92 0.87 0.82 0.77 0.71 0.65 0.58 0.48 0.46 0.44 0.41 0.39 0.36 ------0.58 0.59 0.59 0.59 0.57 0.54 0.52 0.49 --0.59 0.60 0.62 0.62 0.61 0.60 0.58 0.56 0.52 0.59 0.62 0.64 0.66 0.68 0.70 0.71 0.69 0.67 0.60 0.64 0.67 0.71 0.75 0.79 0.84 0.88 0.92 Table 24 – 548J*05 ELECTRIC DRIVE, X13 MOTOR, 4 TON VERTICAL SUPPLY SPEED (TORQUE) TAP 1 2 3 4 5 37 CFM ESP BHP 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 1200 1300 1400 1500 1600 1700 1800 1900 2000 0.50 0.36 0.19 0.10 0.02 --------0.80 0.69 0.50 0.38 0.24 0.13 0.01 ----0.89 0.78 0.59 0.46 0.31 0.20 0.07 ----0.89 0.80 0.67 0.57 0.43 0.31 0.23 0.12 0.01 0.94 0.85 0.73 0.65 0.55 0.47 0.42 0.39 0.38 0.39 0.37 0.35 0.33 0.32 --------0.55 0.55 0.54 0.52 0.50 0.48 0.46 ----0.59 0.61 0.60 0.58 0.56 0.54 0.52 ----0.60 0.63 0.64 0.65 0.65 0.66 0.65 0.63 0.62 0.62 0.65 0.68 0.70 0.72 0.75 0.78 0.82 0.88 548J Table 23 – 548J*05 ELECTRIC DRIVE, X13 MOTOR, 4 TON HORIZONTAL SUPPLY FAN PERFORMANCE (cont.) Table 25 – 548J*06 ELECTRIC DRIVE, X13 MOTOR, 5 TON HORIZONTAL SUPPLY SPEED (TORQUE) TAP 548J 1 2 3 4 5 CFM ESP BHP 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1.19 1.01 0.82 0.60 0.38 0.16 ------1.40 1.25 1.08 0.90 0.67 0.44 0.20 ----1.41 1.28 1.13 0.96 0.74 0.51 0.27 0.02 --1.44 1.35 1.24 1.11 0.90 0.69 0.43 0.17 --1.49 1.38 1.28 1.18 1.11 0.97 0.72 0.47 0.20 0.74 0.73 0.70 0.66 0.62 0.57 ------0.86 0.88 0.86 0.84 0.80 0.75 0.71 ----0.87 0.89 0.89 0.88 0.85 0.80 0.75 0.70 --0.89 0.93 0.96 0.98 0.96 0.92 0.86 0.81 --0.90 0.95 1.00 1.05 1.09 1.11 1.07 1.02 0.96 Table 26 – 548J*06 ELECTRIC DRIVE, X13 MOTOR, 5 TON VERTICAL SUPPLY SPEED (TORQUE) TAP 1 2 3 4 5 38 CFM ESP BHP 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1500 1625 1750 1875 2000 2125 2250 2375 2500 1.00 0.72 0.46 0.28 0.14 0.00 ------1.18 1.00 0.75 0.51 0.30 0.13 ------1.19 1.03 0.80 0.56 0.35 0.19 0.01 ----1.25 1.09 0.89 0.65 0.45 0.26 0.12 ----1.26 1.16 0.99 0.80 0.67 0.48 0.26 0.11 --- 0.70 0.65 0.60 0.55 0.51 0.52 ------0.88 0.90 0.87 0.83 0.79 0.75 ------0.88 0.91 0.90 0.87 0.83 0.80 0.77 ----0.89 0.93 0.96 0.94 0.93 0.89 0.86 ----0.90 0.96 1.01 1.05 1.07 1.07 1.03 1.00 --- FAN PERFORMANCE (cont.) CFM 900 975 1050 1125 1200 1275 1350 1425 1500 BHP 0.13 0.15 0.18 0.20 0.23 0.26 0.30 0.34 0.38 BHP 0.47 0.50 0.53 0.57 0.61 0.65 0.70 0.75 0.80 RPM 999 1015 1030 1047 1064 1082 1100 1119 1138 BHP 0.77 0.80 0.84 0.88 0.92 0.97 1.02 1.08 1.14 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 0.93 1220 1.11 1284 0.97 1233 1.15 1297 1.01 1247 1.19 1311 1.05 1261 1.23 1325 1.10 1276 1.28 1339 1.15 1292 1.33 1354 1.20 1308 1.39 1370 1.26 1325 1.45 1386 1.33 1342 1.52 1403 BHP 1.30 1.33 1.38 1.42 1.47 1.53 1.59 1.65 1.72 RPM 1346 1358 1371 1385 1399 1414 1429 1444 1461 0.2 RPM 574 597 621 646 671 696 723 749 776 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 3 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 707 0.23 817 0.34 913 727 0.25 835 0.37 929 747 0.28 853 0.40 946 768 0.31 872 0.43 964 790 0.34 892 0.47 982 812 0.38 912 0.51 1001 835 0.42 933 0.55 1020 859 0.46 955 0.60 1040 883 0.51 977 0.65 1061 1.2 RPM 1078 1093 1108 1123 1140 1157 1174 1192 1210 RPM 1151 1165 1180 1195 1210 1226 1243 1260 1278 1.0 BHP 0.61 0.64 0.68 0.72 0.76 0.81 0.86 0.91 0.97 2.0 BHP 1.49 1.53 1.58 1.62 1.68 1.73 1.80 1.86 1.93 Italicized area --- X13 electric (direct drive motor, see page 36 for speed/torque setting). Med static motor and drive (belt drive) High static motor and drive (belt drive) Table 28 – 548J*04 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 BHP 0.15 0.17 0.19 0.22 0.25 0.29 0.33 0.37 0.42 BHP 0.52 0.55 0.58 0.62 0.66 0.71 0.76 0.81 0.87 RPM 1084 1092 1102 1113 1126 1140 1155 1171 1188 BHP 0.86 0.89 0.92 0.97 1.01 1.06 1.12 1.18 1.24 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.05 1354 1.25 1434 1.08 1358 1.29 1437 1.12 1363 1.32 1441 1.16 1370 1.37 1447 1.21 1378 1.42 1454 1.26 1387 1.47 1462 1.32 1397 1.53 1471 1.38 1409 1.59 1481 1.45 1421 1.66 1492 BHP 1.47 1.51 1.54 1.59 1.64 1.69 1.75 1.82 1.89 RPM 1511 1513 1516 1520 1526 1533 1541 ----- 0.2 RPM 594 618 642 668 695 722 750 778 807 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 3 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 740 0.25 867 0.37 981 758 0.28 881 0.40 991 777 0.30 896 0.43 1003 797 0.34 912 0.47 1017 818 0.37 930 0.51 1032 841 0.41 949 0.55 1048 864 0.46 968 0.60 1065 888 0.50 989 0.65 1083 913 0.56 1011 0.71 1103 1.2 RPM 1180 1186 1194 1204 1215 1227 1240 1254 1270 RPM 1269 1275 1281 1289 1298 1309 1321 1333 1347 1.0 BHP 0.68 0.71 0.75 0.79 0.83 0.88 0.93 0.99 1.05 2.0 BHP 1.70 1.74 1.78 1.82 1.87 1.92 1.99 ----- Italicized area --- X13 electric (direct drive motor, see page 36 for speed/torque setting). Med static motor and drive (belt drive) High static motor and drive (belt drive) Bold Face indicates field --- supplied drive 1. Recommend using field --- supplied fan pulley (part no. KR11AD561), motor pulley (part no. KR11HY181) and belt (part no.KR29AF041). 39 548J Table 27 – 548J*04 FAN PERFORMANCE (cont.) Table 29 – 548J*05 CFM 548J 1200 1300 1400 1500 1600 1700 1800 1900 2000 BHP 0.23 0.28 0.33 0.38 0.45 0.52 0.60 0.69 0.78 BHP 0.61 0.67 0.73 0.80 0.89 0.97 1.07 1.18 1.29 RPM 1064 1088 1113 1138 1165 1192 1221 1250 1280 BHP 0.92 0.99 1.06 1.14 1.23 1.33 1.44 1.55 1.68 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.10 1276 1.28 1339 1.16 1297 1.35 1360 1.24 1319 1.43 1381 1.33 1342 1.52 1403 1.42 1365 1.62 1425 1.52 1390 1.72 1449 1.63 1415 1.84 1473 1.75 1441 1.96 1498 1.88 1467 2.10 1524 BHP 1.47 1.55 1.63 1.72 1.82 1.93 2.05 2.18 2.32 RPM 1399 1419 1439 1461 1483 1505 1529 ----- 0.2 RPM 671 705 740 776 813 851 888 927 965 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 4 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 790 0.34 892 0.47 982 820 0.39 919 0.52 1007 851 0.45 947 0.58 1034 883 0.51 977 0.65 1061 916 0.58 1007 0.73 1089 949 0.66 1038 0.81 1118 984 0.75 1069 0.90 1148 1019 0.84 1102 1.00 1179 1054 0.94 1135 1.11 1210 1.2 RPM 1140 1162 1186 1210 1236 1262 1289 1317 1345 RPM 1210 1232 1254 1278 1302 1328 1354 1380 1408 1.0 BHP 0.76 0.82 0.89 0.97 1.05 1.15 1.25 1.36 1.48 2.0 BHP 1.68 1.75 1.84 1.93 2.04 2.15 2.27 ----- Italicized area --- X13 electric (direct drive motor, see page 37 for speed/torque setting). Med static motor and drive (belt drive) High static motor and drive (belt drive) Bold Face indicates field --- supplied drive 1. Recommend using field --- supplied fan pulley (part no. KR11AD561), motor pulley (part no. KR11HY181) and belt (part no.KR29AF041). Table 30 – 548J*05 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 RPM 818 849 880 913 948 983 1020 1057 1095 BHP 0.66 0.72 0.79 0.87 0.96 1.06 1.16 1.28 1.41 RPM 1126 1145 1166 1188 1213 1239 1266 1295 1325 RPM 1298 1313 1329 1347 1367 1389 1412 1437 1463 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.21 1378 1.42 1454 1.28 1390 1.49 1465 1.36 1405 1.57 1478 1.45 1421 1.66 1492 1.54 1440 1.76 1509 1.65 1459 1.88 1527 1.77 1481 2.00 --1.90 1504 2.13 --2.04 1528 2.28 --- BHP 1.64 1.71 1.79 1.89 1.99 2.11 ------- RPM 1526 1536 --------------- 0.2 RPM 695 731 769 807 847 887 928 969 1010 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 4 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 BHP RPM BHP RPM 0.37 930 0.51 1032 0.43 955 0.57 1053 0.49 982 0.63 1077 0.56 1011 0.71 1103 0.63 1042 0.79 1130 0.72 1073 0.88 1158 0.82 1106 0.98 1188 0.92 1140 1.09 1219 1.04 1175 1.21 1251 BHP 0.25 0.30 0.36 0.42 0.49 0.57 0.66 0.76 0.87 1.2 RPM 1215 1231 1249 1270 1292 1315 1341 1367 1395 BHP 1.01 1.08 1.16 1.24 1.34 1.44 1.56 1.68 1.82 1.0 BHP 0.83 0.89 0.97 1.05 1.14 1.24 1.35 1.48 1.61 2.0 BHP 1.87 1.94 --------------- Italicized area --- X13 electric (direct drive motor, see page 37 for speed/torque setting). Med static motor and drive (belt drive) High static motor and drive (belt drive) Bold Face indicates field --- supplied drive 1. Recommend using field --- supplied fan pulley (part no. KR11AD561), motor pulley (part no. KR11HY181) and belt (part no.KR29AF041). 40 FAN PERFORMANCE (cont.) CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 RPM 840 876 912 950 988 1027 1067 1107 1148 BHP 0.75 0.84 0.94 1.05 1.18 1.31 1.46 1.63 1.81 RPM 1101 1131 1162 1194 1226 1260 1294 1329 1364 RPM 1239 1267 1296 1326 1357 1388 1420 1453 1487 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.23 1302 1.40 1361 1.34 1329 1.52 1388 1.46 1358 1.65 1416 1.60 1387 1.79 1445 1.74 1417 1.95 1474 1.90 1447 2.11 1504 2.08 1479 2.29 1534 2.27 1511 2.49 1566 2.47 1543 2.70 1597 BHP 1.58 1.71 1.84 1.99 2.15 2.33 2.51 2.72 2.94 RPM 1418 1444 1472 1499 1528 1557 1587 ----- 0.2 RPM 725 765 806 847 889 931 974 1018 1061 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 BHP RPM BHP RPM 0.46 937 0.60 1023 0.54 970 0.68 1054 0.63 1004 0.78 1087 0.72 1039 0.88 1120 0.83 1075 1.00 1154 0.95 1112 1.13 1189 1.08 1149 1.27 1224 1.23 1187 1.43 1261 1.39 1226 1.59 1297 BHP 0.33 0.40 0.48 0.57 0.66 0.78 0.90 1.03 1.19 1.2 RPM 1172 1201 1231 1262 1294 1326 1359 1393 1427 BHP 1.06 1.16 1.28 1.41 1.55 1.70 1.87 2.05 2.24 1.0 BHP 0.90 1.00 1.11 1.23 1.36 1.50 1.66 1.84 2.02 2.0 BHP 1.77 1.90 2.04 2.20 2.36 2.55 2.74 ----- Italicized area --- X13 electric (direct drive motor, see page 38 for speed/torque setting). Med static motor and drive (belt drive) High static motor and drive (belt drive) Table 32 – 548J*06 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 RPM 902 945 988 1033 1078 1124 1170 1217 1265 BHP 0.85 0.96 1.09 1.23 1.39 1.56 1.74 1.95 2.17 RPM 1147 1185 1223 1263 1303 1343 1385 1427 1470 RPM 1277 1313 1350 1387 1426 1464 1504 1544 1585 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.33 1336 1.50 1392 1.47 1371 1.65 1427 1.63 1407 1.81 1462 1.80 1444 1.99 1498 1.98 1482 2.19 1535 2.18 1520 2.40 1573 2.40 1559 2.62 1611 2.63 1598 2.87 --2.89 ------- BHP 1.67 1.83 2.01 2.19 2.40 2.62 2.85 ----- RPM 1445 1479 1514 1550 1586 1623 ------- 0.2 RPM 794 840 888 936 984 1033 1083 1133 1183 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 BHP RPM BHP RPM 0.55 993 0.69 1074 0.64 1034 0.80 1113 0.75 1075 0.92 1153 0.87 1117 1.05 1193 1.00 1160 1.19 1235 1.15 1204 1.35 1277 1.32 1248 1.53 1319 1.50 1293 1.72 1363 1.70 1339 1.93 1406 BHP 0.41 0.49 0.59 0.70 0.82 0.96 1.11 1.28 1.47 1.2 RPM 1214 1251 1289 1327 1366 1406 1446 1487 1529 BHP 1.16 1.30 1.44 1.60 1.78 1.97 2.18 2.40 2.64 Italicized area --- X13 electric (direct drive motor, see page 38 for speed/torque setting). Non--- shaded area --- X13 electric drive motor, see page 38 for speed/torque setting. Med static motor and drive (belt drive) High static motor and drive (belt drive) 41 1.0 BHP 1.00 1.13 1.26 1.41 1.58 1.76 1.96 2.17 2.41 2.0 BHP 1.85 2.02 2.20 2.40 2.61 2.84 ------- 548J Table 31 – 548J*06 FAN PERFORMANCE (cont.) Table 33 – 548J*07 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 548J RPM 927 973 1019 1067 1115 1164 1214 1264 1315 BHP 0.98 1.13 1.29 1.46 1.66 1.88 2.12 2.39 2.68 RPM 1174 1213 1253 1294 1336 1379 1422 1467 1512 RPM 1308 1345 1382 1420 1460 1500 1541 ----- AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.51 1369 1.70 1427 1.68 1405 1.88 1462 1.87 1441 2.08 1498 2.08 1479 2.29 1534 2.31 1517 2.53 1572 2.55 1557 2.79 --2.83 ----------------------- BHP 1.90 2.09 2.29 2.51 2.76 --------- RPM 1483 1517 1552 1587 ----------- RPM 1006 1060 1115 1170 1227 1284 1342 1400 1459 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 BHP RPM BHP RPM 0.80 1092 0.97 1169 0.95 1143 1.13 1218 1.12 1195 1.32 1268 1.32 1248 1.53 1319 1.54 1302 1.76 1371 1.78 1357 2.02 1424 2.06 1412 2.31 1478 2.36 1469 2.62 1532 2.69 ------- BHP 1.14 1.32 1.52 1.74 1.99 2.26 2.56 2.89 --- RPM 1239 1287 1335 1385 1435 1487 1539 ----- RPM 1365 1410 1457 1504 1552 --------- AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 BHP RPM BHP RPM 1.69 1422 1.88 1477 1.91 1467 2.11 1520 2.14 1512 2.35 1565 2.40 1559 2.62 1611 2.68 --------------------------------------- BHP 2.08 2.31 2.57 2.85 ----------- RPM 1528 1572 1616 ------------- 0.2 RPM ----923 974 1026 1079 1132 1186 1240 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 6 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 BHP RPM BHP RPM 0.66 1018 0.82 1100 0.79 1061 0.95 1140 0.92 1104 1.10 1182 1.08 1149 1.27 1224 1.26 1195 1.46 1268 1.46 1241 1.67 1312 1.67 1289 1.90 1358 1.92 1336 2.15 1404 2.18 1385 2.43 1451 BHP ----0.75 0.90 1.06 1.25 1.46 1.69 1.94 1.2 RPM 1244 1281 1320 1359 1400 1441 1483 1527 --- BHP 1.33 1.49 1.67 1.87 2.09 2.33 2.59 2.87 --- 1.0 BHP 1.15 1.31 1.48 1.66 1.87 2.10 2.35 2.63 2.93 2.0 BHP 2.10 2.30 2.51 2.74 ----------- Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) Table 34 – 548J*07 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 0.2 RPM 907 965 1024 1083 1143 1203 1264 1326 1387 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 6 TON VERTICAL SUPPLY BHP 0.63 0.77 0.93 1.11 1.32 1.55 1.81 2.09 2.41 1.2 RPM 1304 1350 1398 1446 1496 1546 ------- BHP 1.51 1.71 1.93 2.18 2.45 2.75 ------- Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) 42 1.0 BHP 1.32 1.51 1.72 1.96 2.22 2.50 2.82 ----- 2.0 BHP 2.28 2.52 2.79 ------------- FAN PERFORMANCE (cont.) CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 BHP ----0.40 0.47 0.55 0.65 0.75 0.86 0.99 BHP 0.66 0.73 0.82 0.91 1.02 1.13 1.26 1.39 1.54 RPM 725 733 743 753 765 779 793 808 824 BHP 0.94 1.03 1.13 1.24 1.36 1.49 1.63 1.78 1.94 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 RPM BHP RPM BHP RPM 847 1.09 903 1.25 957 852 1.19 907 1.36 959 858 1.30 911 1.47 963 865 1.41 917 1.59 967 874 1.54 925 1.72 974 884 1.68 933 1.87 981 895 1.82 943 2.02 990 907 1.98 954 2.19 1000 920 2.15 966 2.36 1011 BHP 1.41 1.52 1.64 1.77 1.91 2.06 2.22 2.40 2.58 RPM 1009 1010 1012 1016 1021 1028 1035 1044 1054 0.2 RPM ----465 487 510 534 557 582 606 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 7.5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 509 0.40 587 0.52 659 525 0.46 600 0.59 669 543 0.53 614 0.67 680 561 0.61 629 0.76 693 580 0.70 646 0.86 707 600 0.80 663 0.96 722 621 0.91 681 1.08 738 642 1.03 700 1.21 755 664 1.17 720 1.35 773 1.2 RPM 788 794 802 811 821 832 845 858 873 1.0 BHP 0.80 0.88 0.97 1.08 1.19 1.31 1.44 1.58 1.74 2.0 BHP 1.58 1.70 1.82 1.96 2.11 2.26 2.43 2.61 2.80 Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) Table 36 – 548J*08 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 BHP --0.37 0.45 0.53 0.62 0.72 0.84 0.97 1.11 BHP 0.66 0.75 0.85 0.96 1.08 1.21 1.36 1.52 1.68 RPM 713 729 745 763 780 799 818 837 857 BHP 0.89 1.00 1.12 1.25 1.39 1.54 1.70 1.88 2.07 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 RPM BHP RPM BHP RPM 812 1.02 856 1.14 899 826 1.13 870 1.26 912 841 1.26 885 1.40 926 857 1.40 900 1.55 941 873 1.55 916 1.70 956 890 1.71 932 1.87 972 907 1.88 949 2.05 988 925 2.06 966 2.25 1005 944 2.26 984 2.45 1022 BHP 1.26 1.40 1.54 1.69 1.86 2.04 2.23 2.43 2.65 RPM 939 952 966 980 995 1010 1026 1042 1059 0.2 RPM --470 494 518 543 568 593 619 645 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 7.5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 528 0.43 597 0.54 658 548 0.50 615 0.62 675 569 0.58 634 0.71 692 590 0.67 653 0.82 710 612 0.77 673 0.93 729 635 0.89 694 1.05 749 658 1.01 716 1.19 769 681 1.15 737 1.33 789 705 1.30 760 1.49 810 1.2 RPM 764 779 795 811 828 846 864 882 902 Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) 43 1.0 BHP 0.78 0.88 0.99 1.11 1.24 1.38 1.53 1.70 1.88 2.0 BHP 1.39 1.53 1.68 1.84 2.02 2.21 2.40 2.62 2.84 548J Table 35 – 548J*08 FAN PERFORMANCE (cont.) Table 37 – 548J*09 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 548J BHP 0.39 0.47 0.57 0.68 0.80 0.94 1.09 1.26 1.45 BHP 0.80 0.91 1.03 1.17 1.31 1.48 1.66 1.85 2.07 RPM 747 760 774 789 806 824 843 864 885 BHP 1.11 1.24 1.37 1.53 1.69 1.87 2.07 2.28 2.51 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 RPM BHP RPM BHP RPM 863 1.28 916 1.45 968 871 1.41 924 1.59 974 882 1.55 932 1.74 981 894 1.71 943 1.90 990 907 1.88 955 2.09 1001 922 2.07 968 2.28 1013 938 2.28 983 2.49 1027 955 2.50 999 2.72 1041 973 2.74 1015 2.97 1057 BHP 1.62 1.77 1.93 2.10 2.29 2.49 2.71 2.95 3.21 RPM 1018 1022 1028 1036 1046 1057 ------- 0.2 RPM 468 493 520 547 575 603 631 660 689 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 8.5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 546 0.52 618 0.66 684 567 0.61 635 0.76 699 589 0.72 654 0.87 716 613 0.83 675 1.00 733 637 0.96 696 1.14 752 662 1.11 719 1.29 773 688 1.27 742 1.46 794 714 1.45 766 1.65 816 741 1.65 790 1.86 838 1.2 RPM 806 817 829 843 858 874 891 910 930 1.0 BHP 0.96 1.07 1.20 1.34 1.50 1.67 1.86 2.06 2.29 2.0 BHP 1.80 1.95 2.12 2.30 2.50 2.71 ------- Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) Table 38 – 548J*09 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 BHP 0.43 0.53 0.63 0.76 0.89 1.05 1.22 1.41 1.62 BHP 0.83 0.95 1.09 1.25 1.42 1.60 1.81 2.03 2.28 RPM 746 766 787 808 831 854 877 901 926 BHP 1.09 1.24 1.40 1.57 1.76 1.97 2.20 2.45 2.71 AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 1.4 1.6 1.8 RPM BHP RPM BHP RPM 841 1.23 885 1.36 926 859 1.38 902 1.53 943 878 1.55 921 1.71 961 898 1.74 940 1.90 979 919 1.94 960 2.12 998 940 2.16 980 2.34 1018 962 2.40 1001 2.59 1039 984 2.65 1023 2.86 ------------- BHP 1.50 1.68 1.86 2.07 2.29 2.53 2.79 ----- RPM 965 982 999 1017 1036 1055 ------- 0.2 RPM 495 524 552 582 611 641 672 702 733 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 8.5 VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (IN. WG) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 570 0.56 634 0.70 693 595 0.67 657 0.81 714 620 0.79 681 0.94 736 647 0.92 705 1.08 759 674 1.07 730 1.24 782 701 1.23 756 1.42 806 729 1.42 782 1.61 831 758 1.62 809 1.83 857 787 1.84 836 2.06 883 1.2 RPM 795 814 834 855 876 898 921 944 968 Std static motor and drive (belt drive) Med static motor and drive (belt drive) High static motor and drive (belt drive) 44 1.0 BHP 0.96 1.09 1.24 1.41 1.59 1.79 2.00 2.24 2.49 2.0 BHP 1.64 1.82 2.02 2.24 2.47 2.72 ------- FAN PERFORMANCE (cont.) 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 09 08 07 06 05 04 UNIT MOTOR/DRIVE COMBO MOTOR PULLEY TURNS OPEN 2 2.5 3 3.5 0 0.5 1 1.5 4 4.5 5 Medium Static 1251 1208 1165 1121 1078 1035 992 949 905 862 819 High Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 Medium Static 1303 1265 1226 1188 1150 1112 1073 1035 997 958 920 High Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 Medium Static 1380 1349 1317 1286 1254 1223 1192 1160 1129 1097 1066 High Static 1639 1596 Standard Static Medium Static High Static Standard Static Medium Static High Static Standard Static Medium Static High Static 1192 1380 1639 652 838 1084 652 838 1084 1161 1349 1596 633 813 1059 633 813 1059 1553 1510 1467 1424 1380 1337 1294 1251 1208 1129 1317 1553 614 789 1035 614 789 1035 1098 1286 1510 594 764 1010 594 764 1010 1066 1254 1467 575 739 986 575 739 986 1035 1223 1424 556 715 961 556 715 961 1004 1192 1380 537 690 936 537 690 936 972 1160 1337 518 665 912 518 665 912 941 1129 1294 498 640 887 498 640 887 909 1097 1251 479 616 863 479 616 863 878 1066 1208 460 591 838 460 591 838 NOTE: Do not adjust pulley further than 5 turns open. --- Factory settings 45 548J Table 39 – PULLEY ADJUSTMENT ECONOMIZER, BAROMETRIC RELIEF AND PE PERFORMANCE 2500 Horizontal Economizers 2000 1500 RELIEF FLOW (CFM) RELIEF FLOW (CFM) 2500 3-6 Ton 7.5-8.5 Ton 1000 500 Vertical Economizers 2000 1500 3 - 6 Ton 7.5 - 8.5 Ton 1000 500 0 0 0 0.05 0.1 0.15 0.2 0.25 0 0.3 0.05 0.1 0.15 0.2 0.25 0.3 RETURN DUCT STATIC PRESS URE (in. wg) RETURN DUCT STATIC PRESS URE (in. wg) C09028 C09031 30 Fig. 13 -- Barometric Relief Flow Capacity LEAKAGE ACROSS DAMPER (CFM) LEAKAGE ACROSS DAMPER (CFM) 548J Fig. 9 -- Barometric Relief Flow Capacity Horizontal Economizers 25 20 3 - 6 Ton 7.5 - 8.5 Ton 15 10 5 0 0.00 0.10 0.20 0.30 0.40 30 Vertical Economizers 25 20 3 - 6 Ton 7.5 - 8.5 Ton 15 10 5 0 0.00 0.10 0.50 0.20 0.30 0.40 0.50 STATIC PRESS URE DELTA (in. wg) STATIC PRESS URE DELTA (in. wg) C09029 C09032 6000 Fig. 14 -- Outdoor Air Damper Leakage 6000 Horizontal Economizers 5000 4000 RETURN AIR FLOW (CFM) RETURN AIR FLOW (CFM) Fig. 10 -- Outdoor Air Damper Leakage 3 - 6 Ton 7.5 - 8.5 Ton 3000 2000 1000 Vertical Economizers 5000 4000 3 - 6 Ton 7.5 - 8.5 Ton 3000 2000 1000 0 0 0 0.1 0.2 0.3 0 0.4 0.1 0.2 0.3 0.4 RETURN DUCT STATIC PRESS URE DROP (in. wg) RETURN DUCT STATIC PRESS URE DROP (in. wg) C09030 C09033 5000 Fig. 15 -- Return Air Pressure Drop Vertical Power Exhaust 4000 3000 2- 6 Ton 2000 7. 5- 8.5 Ton 1000 EXHAUST AIRFLOW (cfm) EXHAUST AIRFLOW (cfm) Fig. 11 -- Return Air Pressure Drop 0 5000 4000 3000 2- 6 Ton 2000 7. 5- 12 .5 Ton 1000 0 0 0.1 0.2 0.3 0.4 0.5 0 RETURN DUCT STATIC PRESSURE (in. wg) 0.1 0.2 0.3 0.4 0.5 RETURN DUCT STATIC PRESSURE (in. wg) C08012 C09034 Fig. 12 -- Horizontal Power Exhaust Performance Fig. 16 -- Power Exhaust Performance 46 ELECTRICAL INFORMATION V-- Ph-- Hz 1-- Stage Cooling VOLTAGE RANGE COMP (ea) OFM (ea) IFM MIN MAX RLA LRA WATTS FLA TYPE 208--1--60 230--1--60 187 187 253 253 17.9 17.9 112 112 190 190 0.9 0.9 208--3--60 187 253 13.2 88 190 0.9 230--3--60 187 253 13.2 88 190 0.9 460--3--60 414 506 6.0 44 190 0.5 575--3--60 518 633 NA NA 190 0.4 DD--STD DD--STD DD--STD MED HIGH DD--STD MED HIGH DD--STD MED HIGH DD--STD MED HIGH Table 41 – 548J*05 V-- Ph-- Hz Max WATTS 980 980 980 2000 2000 980 2000 2000 980 2000 2000 980 2000 2000 Max AMP Draw 7.8 7.8 7.8 5.5 5.5 7.8 5.5 5.5 8.0 2.7 2.7 4.2 2.5 2.1 EFF at Full Load FLA 84% 84% 84% 80% 80% 84% 80% 80% 84% 80% 80% 84% 80% 80% 7.4 7.4 7.4 5.2 5.2 7.4 5.2 5.2 7.6 2.6 2.6 4.0 2.4 2.0 1-- Stage Cooling VOLTAGE RANGE COMP (ea) 4 TONS OFM (ea) IFM MIN MAX RLA LRA WATTS FLA TYPE 208--1--60 230--1--60 187 187 253 253 21.8 21.8 117 117 325 325 1.5 1.5 208--3--60 187 253 13.7 83 325 1.5 230--3--60 187 253 13.7 83 325 1.5 460--3--60 414 506 6.2 41 325 0.8 575--3--60 518 633 4.8 37 325 0.6 DD--- STD DD--- STD DD--- STD MED HIGH DD--- STD MED HIGH DD--- STD MED HIGH DD--- STD MED HIGH Table 42 – 548J*06 V ---Ph---Hz 3 TONS Max WATTS 980 980 980 2000 2000 980 2000 2000 980 2000 2000 980 2000 2000 Max AMP Draw 7.8 7.8 7.8 5.5 5.5 7.8 5.5 5.5 8.0 2.7 2.7 4.2 2.5 2.1 EFF at Full Load FLA 84% 84% 84% 80% 80% 84% 80% 80% 84% 80% 80% 84% 80% 80% 7.4 7.4 7.4 5.2 5.2 7.4 5.2 5.2 7.6 2.6 2.6 4.0 2.4 2.0 1-- Stage Cooling VOLTAGE RANGE COM P (ea) OFM (ea) 5 TONS IFM MIN MAX RLA LRA WATTS FLA TYPE 208--- 1--- 60 230--- 1--- 60 187 187 253 253 26.2 26.2 134 134 325 325 1.5 1.5 208--- 3--- 60 187 253 15.6 110 325 1.5 230--- 3--- 60 187 253 15.6 110 325 1.5 460--- 3--- 60 414 506 7.7 52 325 0.8 575--- 3--- 60 518 633 5.8 39 325 0.6 DD--- STD DD--- STD DD--- STD MED HIGH DD--- STD MED HIGH DD--- STD MED HIGH DD--- STD MED HIGH 47 Max WATTS 980 980 980 2000 2770 980 2000 2770 980 2000 2770 980 2000 2770 Max AMP Draw 7.8 7.8 7.8 5.5 7.9 7.8 5.5 7.9 8.0 2.7 3.6 4.2 2.1 2.9 EFF at Full Load FLA 84% 84% 84% 80% 81% 84% 80% 81% 84% 80% 81% 84% 80% 81% 7.4 7.4 7.4 5.2 7.5 7.4 5.2 7.5 7.6 2.6 3.4 4.0 2.0 2.8 548J Table 40 – 548J*04 ELECTRICAL INFORMATION (cont.) Table 43 – 548J*07 V ---Ph---Hz VOLTAGE RANGE MIN 548J 1-- Stage Cooling MAX COMP (ea) RLA LRA OFM (ea) WATTS IFM FLA 208--- 3--- 60 187 253 19.0 123 325 1.5 230--- 3--- 60 187 253 19.0 123 325 1.5 460--- 3--- 60 414 506 9.7 62 325 0.8 575--- 3--- 60 518 633 7.4 50 325 0.6 Table 44 – 548J*08 V ---Ph---Hz 6 TONS Max WATTS 1600 2770 2770 1600 2770 2770 1600 2770 2770 1600 2770 2770 TYPE STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH EFF at Full Load FLA 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 7.5 7.5 5.2 7.5 7.5 2.6 3.4 3.4 2.4 2.8 2.8 2-- Stage Cooling VOLTAGE RANGE COMP (Cir 1) COMP (Cir 2) 7.5 TONS OFM (ea) RLA LRA RLA LRA WATTS FLA MIN MAX 208--- 3--- 60 187 253 13.1 83 13.1 83 325 1.5 230--- 3--- 60 187 253 13.1 83 13.1 83 325 1.5 460--- 3--- 60 414 506 6.1 41 6.1 41 325 0.8 575--- 3--- 60 518 633 4.4 33 4.4 33 325 0.6 Table 45 – 548J*09 V ---Ph---Hz Max AMP Draw 5.5 7.9 7.9 5.5 7.9 7.9 2.7 3.6 3.6 2.5 2.9 2.9 IFM TYPE Max WATTS STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH 1310 2770 2770 1310 2770 2770 1310 2770 2770 1310 2770 2770 Max AMP Draw 5.5 7.9 7.9 5.5 7.9 7.9 2.7 3.6 3.6 2.5 2.9 2.9 2-- Stage Cooling VOLTAGE RANGE COMP (Cir 1) COMP (Cir 2) FLA 5.2 7.5 7.5 5.2 7.5 7.5 2.6 3.4 3.4 2.4 2.8 2.8 8.5 TONS OFM (ea) RLA LRA RLA LRA WATTS FLA MIN MAX 208--- 3--- 60 187 253 16.0 91 13.7 83 325 1.5 230--- 3--- 60 187 253 16.0 91 13.7 83 325 1.5 460--- 3--- 60 414 506 7.0 46 6.2 41 325 0.8 575--- 3--- 60 518 633 5.6 37 4.8 37 325 0.6 48 EFF at Full Load 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% IFM TYPE Max WATTS STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH 1310 2770 2770 1310 2770 2770 1310 2770 2770 1310 2770 2770 Max AMP Draw 5.5 7.9 7.9 5.5 7.9 7.9 2.7 3.6 3.6 2.5 2.9 2.9 EFF at Full Load 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 81% FLA 5.2 7.5 7.5 5.2 7.5 7.5 2.6 3.4 3.4 2.4 2.8 2.8 ELEC. HTR IFM TYPE 208/230---3---60 MCA MOCP DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA DD--- STD 30.7 50.6/53.6 60.1/64.6 69.9/76.1 78.1/85.4 89.3/98.4 24.8 36.3/38.1 41.8/44.3 47.4/50.9 52.2/56.4 66.6/72.9 22.6 34.1/35.9 39.6/42.1 45.2/48.7 50.0/54.2 64.4/70.7 22.6 34.1/35.9 39.6/42.1 45.2/48.7 50.0/54.2 64.4/70.7 16.0 25.0 29.3 33.3 37.0 10.6 19.6 23.9 27.9 31.6 10.6 19.6 23.9 27.9 31.6 5.4 45 60/60 70/70 70/80 80/90 90/100 30 45/45 50/50 50/60 60/60 70/80 30 45/45 45/50 50/50 50/60 70/80 30 45/45 45/50 50/50 50/60 70/80 20 30 30 35 40 15 20 25 30 35 15 20 25 30 35 15 30 48/51 57/61 66/72 74/81 84/92 25 35/37 40/43 46/49 50/54 63/69 22 33/34 38/40 43/46 47/51 61/66 22 33/34 38/40 43/46 47/51 61/66 16 24 28 32 36 10 19 23 26 30 10 19 23 26 30 5 121 137/139 145/148 152/157 159/165 215/229 97 106/108 111/113 115/118 119/122 130/136 109 118/120 123/125 127/130 131/134 142/148 120 129/131 134/136 138/141 142/145 153/159 53 60 64 67 70 54 61 65 68 71 60 67 71 74 77 5 32.6 52.5/55.5 62.0/66.5 71.8/78.0 80.0/87.3 91.2/100.3 26.7 38.2/40.0 43.7/46.2 49.3/52.8 54.1/58.3 68.5/74.8 24.5 36.0/37.8 41.5/44.0 47.1/50.6 51.9/56.1 66.3/72.6 24.5 36.0/37.8 41.5/44.0 47.1/50.6 51.9/56.1 66.3/72.6 17.0 26.0 30.3 34.3 38.0 11.6 20.6 24.9 28.9 32.6 11.6 20.6 24.9 28.9 32.6 7.4 50 60/60 70/70 80/80 80/90 100/110 30 45/50 50/50 50/60 60/60 70/80 30 45/45 50/50 50/60 60/60 70/80 30 45/45 50/50 50/60 60/60 70/80 20 30 35 35 40 15 25 25 30 35 15 25 25 30 35 15 32 51/53 59/63 68/74 76/83 86/95 27 37/39 43/45 48/51 52/56 65/71 24 35/37 40/42 45/48 50/53 63/69 24 35/37 40/42 45/48 50/53 63/69 17 26 30 33 37 12 20 24 27 31 12 20 24 27 31 7 123 139/141 147/150 154/159 161/167 217/231 99 108/110 113/115 117/120 121/124 132/138 111 120/122 125/127 129/132 133/136 144/150 122 131/133 136/138 140/143 144/147 155/161 54 61 65 68 71 55 62 66 69 72 61 68 72 75 78 7 MED --- --- 3.4 15 3 8 5.4 15 5 10 HIGH --- --- 2.9 15 3 12 4.9 15 5 14 DD--- STD MED DD--- STD 460---3---60 FLA WITH P.E. --15.9/18.3 23.5/27.1 31.4/36.3 37.9/43.8 46.9/54.2 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --7.2 10.6 13.8 16.8 --7.2 10.6 13.8 16.8 --7.2 10.6 13.8 16.8 --- HIGH MED HIGH 575---3---60 WITHOUT P.E. Nom (kW) --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 9.8/13.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --6.0 8.8 11.5 14.0 --6.0 8.8 11.5 14.0 --6.0 8.8 11.5 14.0 --- DD--- STD 548J*04 WITHOUT C.O. or UNPWR C.O. LEGEND C.O. --- Convenient outlet DD --- Electric Drive X13 Motor DISC --- Disconnect FLA --- Full load amps IFM --- Indoor fan motor LRA --- Locked rotor amps MCA --- Minimum circuit amps MOCP --- Maximum over current protection P.E. --- Power exhaust UNPWRD C.O. --- Unpowered convenient outlet NOTES: 1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker. 2. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage Imbalance = 100 x Example: Supply voltage is 230-3-60 AB = 224V BC = 231V AC = 226V Average Voltage = = (224 + 231 + 226) 3 227 = 681 3 Determine maximum deviation from average voltage. (AB) 227 – 224 = 3V Maximum deviation is 4V. (BC) 231 – 227 = 4V Determine percent of voltage imbalance. % Voltage Imbalance = 100 x 4 227 = 1.76% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. max voltage deviation from average voltage average voltage 49 548J 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 46 – MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 46 – (cont.) MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. ELEC. HTR IFM TYPE 208/230---3---60 460---3---60 MCA MOCP DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA 36.2 56.0/59.0 75.4/81.5 94.8/103.9 114.7/126.8 130.9/145.5 26.0 43.0/45.5 48.7/52.2 67.8/74.2 80.8/89.2 23.8 40.8/43.3 46.5/50.0 65.6/72.0 78.6/87.0 23.8 40.8/43.3 46.5/50.0 65.6/72.0 78.6/87.0 16.5 25.5 33.8 37.5 51.1 11.2 20.2 28.4 32.2 45.8 11.2 20.2 28.4 32.2 45.8 50 60/60 80/90 100/110 125/150 150/150 30 50/50 50/60 70/80 90/90 30 50/50 50/50 70/80 80/90 30 50/50 50/50 70/80 80/90 20 30 35 40 60 15 25 30 35 50 15 25 30 35 50 35 54/56 71/77 89/98 108/119 122/136 26 42/44 47/50 64/70 76/84 23 39/41 44/47 62/68 74/82 23 39/41 44/47 62/68 74/82 17 25 33 36 49 11 19 27 30 43 11 19 27 30 43 128 144/146 159/164 222/236 254/273 280/303 94 108/110 112/115 127/133 182/195 106 120/122 124/127 139/145 194/207 117 131/133 135/138 150/156 205/218 51 58 65 68 106 52 59 66 69 107 58 65 72 75 113 38.1 57.9/60.9 77.3/83.4 96.7/105.8 116.6/128.7 132.8/147.4 27.9 44.9/47.4 50.6/54.1 69.7/76.1 82.7/91.1 25.7 42.7/45.2 48.4/51.9 67.5/73.9 80.5/88.9 25.7 42.7/45.2 48.4/51.9 67.5/73.9 80.5/88.9 17.5 26.5 34.8 38.5 52.1 12.2 21.2 29.4 33.2 46.8 12.2 21.2 29.4 33.2 46.8 50 60/70 80/90 100/110 125/150 150/150 40 50/50 60/60 70/80 90/100 30 50/50 50/60 70/80 90/90 30 50/50 50/60 70/80 90/90 25 30 35 40 60 15 25 30 35 50 15 25 30 35 50 37 56/59 74/79 91/100 110/121 125/138 28 44/46 49/52 67/72 79/86 26 41/44 46/50 64/70 76/84 26 41/44 46/50 64/70 76/84 18 26 34 37 50 12 20 28 32 44 12 20 28 32 44 130 146/148 161/166 224/238 256/275 282/305 96 110/112 114/117 129/135 184/197 108 122/124 126/129 141/147 196/209 119 133/135 137/140 152/158 207/220 52 59 66 69 107 53 60 67 70 108 59 66 73 76 114 DD--- STD --- --- 10.6 15 11 43 12.5 15 13 45 MED --- --- 9.0 15 9 46 10.9 15 11 48 HIGH --- --- 8.6 15 9 50 10.5 15 11 52 DD--- STD MED DD--- STD MED HIGH 575---3---60 FLA WITH P.E. --15.9/18.3 31.4/36.3 46.9/54.2 62.8/72.5 75.8/87.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --7.2 13.8 16.8 27.7 --7.2 13.8 16.8 27.7 --7.2 13.8 16.8 27.7 HIGH 548J*05 WITHOUT P.E. Nom (kW) --3.3/4.4 6.5/8.7 9.8/13.0 13.1/17.4 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --6.0 11.5 14.0 23.0 --6.0 11.5 14.0 23.0 --6.0 11.5 14.0 23.0 DD--- STD 548J WITHOUT C.O. or UNPWR C.O. See Notes page 49. 50 ELEC. HTR IFM TYPE 208/230---3---60 FLA MCA MOCP WITH P.E. DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA --23.5/27.1 31.4/36.3 46.9/54.2 62.8/72.5 75.8/87.5 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 41.7 71.0/75.5 80.9/87.0 100.3/109.4 120.2/132.3 136.4/151.0 28.4 45.4/47.9 55.8/60.0 70.2/76.5 83.2/91.5 97.4/108.2 26.2 43.2/45.7 53.6/57.8 68.0/74.3 81.0/89.3 95.2/106.0 28.5 45.5/48.0 55.9/60.1 70.3/76.6 83.3/91.6 97.5/108.3 18.0 27.0 35.3 39.0 52.7 56.4 13.0 22.0 30.3 34.0 47.7 51.4 13.8 22.8 31.1 34.8 48.5 52.2 60 80/80 90/100 110/110 125/150 150/175 40 50/50 60/70 80/80 90/100 100/110 40 50/50 60/60 70/80 90/90 100/110 40 50/50 60/70 80/80 90/100 100/110 25 30 40 40 60 60 20 25 35 35 50 60 20 25 35 35 50 60 40 67/72 76/82 94/103 113/124 128/141 28 44/46 53/57 67/72 79/86 92/102 26 41/44 51/55 64/70 76/84 89/99 28 44/46 53/57 67/73 79/86 92/102 19 27 34 38 50 54 13 21 29 32 45 48 14 22 30 33 46 49 145 169/172 176/181 239/253 271/290 297/320 121 135/137 143/146 154/160 209/222 231/249 144 158/160 166/169 177/183 232/245 254/272 170 184/186 192/195 203/209 258/271 280/298 62 69 76 79 117 123 69 76 83 86 124 130 82 89 96 99 137 143 43.6 72.9/77.4 82.8/88.9 102.2/111.3 122.1/134.2 138.3/152.9 30.3 47.3/49.8 57.7/61.9 72.1/78.4 85.1/93.4 99.3/110.1 28.1 45.1/47.6 55.5/59.7 69.9/76.2 82.9/91.2 97.1/107.9 30.4 47.4/49.9 57.8/62.0 72.2/78.5 85.2/93.5 99.4/110.2 19.0 28.0 36.3 40.0 53.7 57.4 14.0 23.0 31.3 35.0 48.7 52.4 14.8 23.8 32.1 35.8 49.5 53.2 60 80/80 100/100 110/125 125/150 150/175 45 50/60 60/70 80/80 90/100 100/125 40 50/50 60/60 70/80 90/100 100/110 45 50/60 60/70 80/80 90/100 100/125 25 30 40 45 60 60 20 25 35 40 50 60 20 25 35 40 50 60 43 70/74 79/84 96/105 115/126 130/143 30 46/48 56/59 69/75 81/88 94/104 28 43/46 53/57 66/72 78/86 91/101 30 46/48 56/60 69/75 81/89 94/104 20 28 36 39 52 55 14 22 30 33 46 49 15 23 31 34 47 50 147 171/174 178/183 241/255 273/292 299/322 123 137/139 145/148 156/162 211/224 233/251 146 160/162 168/171 179/185 234/247 256/274 172 186/188 194/197 205/211 260/273 282/300 63 70 77 80 118 124 70 77 84 87 125 131 83 90 97 100 138 144 DD--- STD --- --- 11.9 15 12 45 13.8 20 14 47 MED --- --- 9.9 15 10 52 11.8 15 12 54 HIGH --- --- 10.7 15 11 63 12.6 15 13 65 DD--- STD MED 548J*06 HIGH DD--- STD 460---3---60 WITHOUT P.E. Nom (kW) --4.9/6.5 6.5/8.7 9.8/13.0 13.1/17.4 15.8/21.0 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 DD--- STD MED HIGH 575---3---60 WITHOUT C.O. or UNPWR C.O. See Notes page 49. 51 548J 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 46 – (cont.) MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. NOM. V ---PH ---HZ UNIT Table 46 – (cont.) MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. ELEC. HTR IFM TYPE 548J 208/230---3---60 STD MED 548J*07 HIGH 460---3---60 STD MED 575---3---60 HIGH WITHOUT C.O. or UNPWR C.O. WITHOUT P.E. Nom (kW) FLA MCA MOCP WITH P.E. DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 30.5 47.5/50.0 57.8/62.1 72.2/78.6 85.2/93.6 99.5/110.2 32.8 49.8/52.3 60.1/64.4 74.5/80.9 87.5/95.9 101.8/112.5 32.8 49.8/52.3 60.1/64.4 74.5/80.9 87.5/95.9 101.8/112.5 15.5 24.5 32.8 36.5 50.2 53.9 16.3 25.3 33.6 37.3 51.0 54.7 16.3 25.3 33.6 37.3 51.0 54.7 45 60/60 60/70 80/80 90/100 100/125 50 60/60 70/70 80/90 90/100 110/125 50 60/60 70/70 80/90 90/100 110/125 25 30 35 40 60 60 25 30 35 40 60 60 25 30 35 40 60 60 30 45/47 55/59 68/74 80/88 93/103 32 48/50 57/61 71/76 83/90 96/106 32 48/50 57/61 71/76 83/90 96/106 15 23 31 34 47 50 16 24 32 35 48 51 16 24 32 35 48 51 146 160/162 168/171 179/185 234/247 256/274 183 197/199 205/208 216/222 271/284 293/311 183 197/199 205/208 216/222 271/284 293/311 73 80 87 90 128 134 92 99 106 109 147 153 92 99 106 109 147 153 32.4 49.4/51.9 59.7/64.0 74.1/80.5 87.1/95.5 101.4/112.1 34.7 51.7/54.2 62.0/66.3 76.4/82.8 89.4/97.8 103.7/114.4 34.7 51.7/54.2 62.0/66.3 76.4/82.8 89.4/97.8 103.7/114.4 16.5 25.5 33.8 37.5 51.2 54.9 17.3 26.3 34.6 38.3 52.0 55.7 17.3 26.3 34.6 38.3 52.0 55.7 50 60/60 60/70 80/90 90/100 110/125 50 60/60 70/70 80/90 90/100 110/125 50 60/60 70/70 80/90 90/100 110/125 25 30 40 40 60 60 25 30 40 40 60 60 25 30 40 40 60 60 32 47/50 57/61 70/76 82/90 95/105 34 50/52 60/63 73/79 85/92 98/108 34 50/52 60/63 73/79 85/92 98/108 16 24 32 36 48 52 17 25 33 36 49 52 17 25 33 36 49 52 148 162/164 170/173 181/187 236/249 258/276 185 199/201 207/210 218/224 273/286 295/313 185 199/201 207/210 218/224 273/286 295/313 74 81 88 91 129 135 93 100 107 110 148 154 93 100 107 110 148 154 STD --- --- 12.3 15 12 59 14.2 20 14 61 MED --- --- 12.7 20 12 74 14.6 20 15 76 HIGH --- --- 12.7 20 12 74 14.6 20 15 76 See Notes page 49. 52 ELEC. HTR IFM TYPE 208/230---3---60 STD MED HIGH 460---3---60 548J*08 STD MED HIGH 575---3---60 STD MED HIGH WITHOUT C.O. or UNPWR C.O. WITHOUT P.E. Nom (kW) --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --17.0 34.0 --17.0 34.0 --17.0 34.0 FLA --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --20.4 40.9 --20.4 40.9 --20.4 40.9 MCA MOCP 37.7 64.8/68.9 79.4/85.8 102.3/112.3 121.1/133.9 148.2/165.2 40.0 67.1/71.2 81.7/88.1 104.6/114.6 123.4/136.2 150.5/167.5 40.0 67.1/71.2 81.7/88.1 104.6/114.6 123.4/136.2 150.5/167.5 17.9 38.8 42.7 59.7 67.6 80.7 18.7 39.6 43.5 60.5 68.4 81.5 18.7 39.6 43.5 60.5 68.4 81.5 13.5 39.0 64.6 13.9 39.4 65.0 13.9 39.4 65.0 50 70/70 80/90 110/125 125/150 150/175 50 70/80 90/90 110/125 125/150 175/175 50 70/80 90/90 110/125 125/150 175/175 20 40 45 60 70 90 25 40 45 70 70 90 25 40 45 70 70 90 15 40 70 20 40 70 20 40 70 WITH P.E. DISC. SIZE FLA LRA 40 65/68 78/84 99/108 116/128 141/157 42 67/71 81/86 102/111 119/131 144/160 42 67/71 81/86 102/111 119/131 144/160 19 38 42 57 65 77 20 39 43 58 65 78 20 39 43 58 65 78 14 38 61 15 38 62 15 38 62 193 215/218 226/232 245/253 260/270 370/397 230 252/255 263/269 282/290 297/307 407/434 230 252/255 263/269 282/290 297/307 407/434 95 112 115 128 135 195 114 131 134 147 154 214 114 131 134 147 154 214 77 97 118 92 112 133 92 112 133 See Notes page 49. 53 MCA MOCP 41.5 68.6/72.7 83.2/89.6 106.1/116.1 124.9/137.7 152.0/169.0 43.8 70.9/75.0 85.5/91.9 108.4/118.4 127.2/140.0 154.3/171.3 43.8 70.9/75.0 85.5/91.9 108.4/118.4 127.2/140.0 154.3/171.3 19.7 40.6 44.5 61.5 69.4 82.5 20.5 41.4 45.3 62.3 70.2 83.3 20.5 41.4 45.3 62.3 70.2 83.3 17.3 42.8 68.4 17.7 43.2 68.8 17.7 43.2 68.8 50 70/80 90/90 110/125 125/150 175/175 50 80/80 90/100 110/125 150/150 175/175 50 80/80 90/100 110/125 150/150 175/175 25 45 45 70 70 90 25 45 50 70 80 90 25 45 50 70 80 90 20 45 70 20 45 70 20 45 70 DISC. SIZE FLA LRA 44 69/73 82/88 103/113 121/132 146/161 47 72/75 85/91 106/115 123/135 148/164 47 72/75 85/91 106/115 123/135 148/164 21 40 44 59 67 79 22 41 45 60 68 80 22 41 45 60 68 80 19 42 66 19 43 66 19 43 66 197 219/222 230/236 249/257 264/274 374/401 234 256/259 267/273 286/294 301/311 411/438 234 256/259 267/273 286/294 301/311 411/438 97 114 117 130 137 197 116 133 136 149 156 216 116 133 136 149 156 216 81 101 122 96 116 137 96 116 137 548J NOM. V ---PH ---HZ UNIT Table 46 – (cont.) MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. NOM. V ---PH ---HZ UNIT Table 46 – (cont.) MCA/MOCP DETERMINATION WITHOUT C.O. OR UNPWRD C.O. ELEC. HTR IFM TYPE 548J 208/230---3---60 STD MED HIGH 460---3---60 548J*09 STD MED HIGH 575---3---60 STD MED HIGH WITHOUT C.O. or UNPWR C.O. WITHOUT P.E. Nom (kW) --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --17.0 34.0 --17.0 34.0 --17.0 34.0 FLA --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --20.4 40.9 --20.4 40.9 --20.4 40.9 MCA MOCP 41.9 69.0/73.2 83.7/90.0 106.5/116.5 125.3/138.2 152.4/169.4 44.2 71.3/75.5 86.0/92.3 108.8/118.8 127.6/140.5 154.7/171.7 44.2 71.3/75.5 86.0/92.3 108.8/118.8 127.6/140.5 154.7/171.7 19.2 40.0 43.9 60.9 68.8 81.9 20.0 40.8 44.7 61.7 69.6 82.7 20.0 40.8 44.7 61.7 69.6 82.7 15.4 40.9 66.5 15.8 41.3 66.9 15.8 41.3 66.9 50 70/80 90/100 110/125 150/150 175/175 60 80/80 90/100 110/125 150/150 175/175 60 80/80 90/100 110/125 150/150 175/175 25 45 45 70 70 90 25 45 45 70 70 90 25 45 45 70 70 90 20 45 70 20 45 70 20 45 70 WITH P.E. DISC. SIZE FLA LRA 44 69/72 82/88 103/112 120/132 145/161 46 71/75 85/91 106/115 123/135 148/164 46 71/75 85/91 106/115 123/135 148/164 20 39 43 58 66 78 21 40 44 59 67 79 21 40 44 59 67 79 16 40 63 17 40 64 17 40 64 201 223/226 234/240 253/261 268/278 378/405 238 260/263 271/277 290/298 305/315 415/442 238 260/263 271/277 290/298 305/315 415/442 100 117 120 133 140 200 119 136 139 152 159 219 119 136 139 152 159 219 85 105 126 100 120 141 100 120 141 See Notes page 49. 54 MCA MOCP 45.7 72.8/77.0 87.5/93.8 110.3/120.3 129.1/142.0 156.2/173.2 48.0 75.1/79.3 89.8/96.1 112.6/122.6 131.4/144.3 158.5/175.5 48.0 75.1/79.3 89.8/96.1 112.6/122.6 131.4/144.3 158.5/175.5 21.0 41.8 45.7 62.7 70.6 83.7 21.8 42.6 46.5 63.5 71.4 84.5 21.8 42.6 46.5 63.5 71.4 84.5 19.2 44.7 70.3 19.6 45.1 70.7 19.6 45.1 70.7 60 80/80 90/100 125/125 150/150 175/175 60 80/80 90/100 125/125 150/150 175/200 60 80/80 90/100 125/125 150/150 175/200 25 45 50 70 80 90 25 45 50 70 80 90 25 45 50 70 80 90 25 45 80 25 50 80 25 50 80 DISC. SIZE FLA LRA 48 73/77 86/92 107/117 125/137 150/165 51 76/79 89/95 110/119 127/139 152/168 51 76/79 89/95 110/119 127/139 152/168 22 41 45 60 68 80 23 42 46 61 69 81 23 42 46 61 69 81 20 44 68 21 44 68 21 44 68 205 227/230 238/244 257/265 272/282 382/409 242 264/267 275/281 294/302 309/319 419/446 242 264/267 275/281 294/302 309/319 419/446 102 119 122 135 142 202 121 138 141 154 161 221 121 138 141 154 161 221 89 109 130 104 124 145 104 124 145 ELEC. HTR IFM TYPE 208/230---3---60 MCA MOCP DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA 35.5 55.4/58.4 64.9/69.4 74.7/80.9 82.9/90.2 94.1/103.2 29.6 41.1/42.9 46.6/49.1 52.2/55.7 57.0/61.2 71.4/77.7 27.4 38.9/40.7 44.4/46.9 50.0/53.5 54.8/59.0 69.2/75.5 27.4 38.9/40.7 44.4/46.9 50.0/53.5 54.8/59.0 69.2/75.5 18.2 27.2 31.5 35.5 39.2 12.8 21.8 26.1 30.1 33.8 12.8 21.8 26.1 30.1 33.8 50 60/60 70/80 80/90 90/100 100/110 40 50/50 50/50 60/60 60/70 80/80 40 45/50 50/50 60/60 60/60 70/80 40 45/50 50/50 60/60 60/60 70/80 25 30 35 40 40 15 25 30 35 35 15 25 30 35 35 36 54/57 63/67 72/77 79/86 90/98 30 41/42 46/48 51/54 55/59 69/75 28 38/40 43/46 49/52 53/57 66/72 28 38/40 43/46 49/52 53/57 66/72 19 27 31 35 38 13 21 25 29 32 13 21 25 29 32 126 142/144 150/153 157/162 164/170 220/234 102 111/113 116/118 120/123 124/127 135/141 114 123/125 128/130 132/135 136/139 147/153 125 134/136 139/141 143/146 147/150 158/164 55 62 66 69 72 56 63 67 70 73 62 69 73 76 79 37.4 57.3/60.3 66.8/71.3 76.6/82.8 84.8/92.1 96.0/105.1 31.5 43.0/44.8 48.5/51.0 54.1/57.6 58.9/63.1 73.3/79.6 29.3 40.8/42.6 46.3/48.8 51.9/55.4 56.7/60.9 71.1/77.4 29.3 40.8/42.6 46.3/48.8 51.9/55.4 56.7/60.9 71.1/77.4 19.2 28.2 32.5 36.5 40.2 13.8 22.8 27.1 31.1 34.8 13.8 22.8 27.1 31.1 34.8 50 60/70 70/80 80/90 90/100 100/110 40 50/50 50/60 60/60 60/70 80/80 40 50/50 50/50 60/60 60/70 80/80 40 50/50 50/50 60/60 60/70 80/80 25 30 35 40 45 20 25 30 35 35 20 25 30 35 35 38 56/59 65/69 74/80 81/88 92/100 32 43/45 48/50 53/56 58/62 71/77 30 40/42 46/48 51/54 55/59 68/74 30 40/42 46/48 51/54 55/59 68/74 20 28 32 36 39 14 22 26 30 33 14 22 26 30 33 128 144/146 152/155 159/164 166/172 222/236 104 113/115 118/120 122/125 126/129 137/143 116 125/127 130/132 134/137 138/141 149/155 127 136/138 141/143 145/148 149/152 160/166 56 63 67 70 73 57 64 68 71 74 63 70 74 77 80 DD--- STD --- --- 7.1 15 7 7 9.5 15 9 9 MED --- --- 5.1 15 5 10 7.5 15 7 12 HIGH --- --- 4.6 15 5 14 7.0 15 7 16 DD--- STD MED DD--- STD 460---3---60 FLA WITH P.E. --15.9/18.3 23.5/27.1 31.4/36.3 37.9/43.8 46.9/54.2 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --9.2/10.6 13.6/15.6 18.1/20.9 21.9/25.3 33.4/38.5 --7.2 10.6 13.8 16.8 --7.2 10.6 13.8 16.8 --7.2 10.6 13.8 16.8 HIGH MED HIGH 575---3---60 WITHOUT P.E. Nom (kW) --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 9.8/13.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --3.3/4.4 4.9/6.5 6.5/8.7 7.9/10.5 12.0/16.0 --6.0 8.8 11.5 14.0 --6.0 8.8 11.5 14.0 --6.0 8.8 11.5 14.0 DD--- STD 548J*04 WITH PWRD C.O. See Notes page 49. 55 548J 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 47 – MCA/MOCP DETERMINATION WITH PWRD C.O. 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 47– (cont.) MCA/MOCP DETERMINATION WITH PWRD C.O. ELEC. HTR IFM TYPE 208/230---3---60 460---3---60 MCA MOCP DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA 41 60.8/63.8 80.2/86.3 99.6/108.7 119.5/131.6 135.7/150.3 30.8 47.8/50.3 53.5/57.0 72.6/79.0 85.6/94.0 28.6 45.6/48.1 51.3/54.8 70.4/76.8 83.4/91.8 28.6 45.6/48.1 51.3/54.8 70.4/76.8 83.4/91.8 18.7 27.7 36.0 39.7 53.3 13.4 22.4 30.6 34.4 48.0 13.4 22.4 30.6 34.4 48.0 60 70/80 90/90 100/110 125/150 150/175 40 50/60 60/60 80/80 90/100 40 50/50 60/60 80/80 90/100 40 50/50 60/60 80/80 90/100 25 30 40 40 60 15 25 35 35 50 15 25 35 35 50 41 59/62 77/83 95/103 113/124 128/141 32 47/49 52/56 70/76 82/90 29 45/47 50/53 67/73 79/87 29 45/47 50/53 67/73 79/87 19 28 35 39 51 14 22 29 33 45 14 22 29 33 45 133 149/151 164/169 227/241 259/278 285/308 99 113/115 117/120 132/138 187/200 111 125/127 129/132 144/150 199/212 122 136/138 140/143 155/161 210/223 53 60 67 70 108 54 61 68 71 109 60 67 74 77 115 42.9 62.7/65.7 82.1/88.2 101.5/110.6 121.4/133.5 137.6/152.2 32.7 49.7/52.2 55.4/58.9 74.5/80.9 87.5/95.9 30.5 47.5/50.0 53.2/56.7 72.3/78.7 85.3/93.7 30.5 47.5/50.0 53.2/56.7 72.3/78.7 85.3/93.7 19.7 28.7 37.0 40.7 54.3 14.4 23.4 31.6 35.4 49.0 14.4 23.4 31.6 35.4 49.0 60 80/80 90/100 110/125 125/150 150/175 45 60/60 60/60 80/90 90/100 40 50/60 60/60 80/80 90/100 40 50/60 60/60 80/80 90/100 25 30 40 45 60 20 25 35 40 50 20 25 35 40 50 43 61/64 79/85 97/105 115/126 130/144 34 49/52 55/58 72/78 84/92 31 47/49 52/55 70/75 82/89 31 47/49 52/55 70/75 82/89 20 29 36 40 52 15 23 31 34 47 15 23 31 34 47 135 151/153 166/171 229/243 261/280 287/310 101 115/117 119/122 134/140 189/202 113 127/129 131/134 146/152 201/214 124 138/140 142/145 157/163 212/225 54 61 68 71 109 55 62 69 72 110 61 68 75 78 116 DD--- STD --- --- 12.3 15 13 45 14.2 20 15 47 MED --- --- 10.7 15 11 48 12.6 15 13 50 HIGH --- --- 10.3 15 10 52 12.2 15 13 54 DD--- STD MED DD--- STD MED HIGH 575---3---60 FLA WITH P.E. --15.9/18.3 31.4/36.3 46.9/54.2 62.8/72.5 75.8/87.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --13.6/15.6 18.1/20.9 33.4/38.5 43.8/50.5 --7.2 13.8 16.8 27.7 --7.2 13.8 16.8 27.7 --7.2 13.8 16.8 27.7 HIGH 548J*05 WITHOUT P.E. Nom (kW) --3.3/4.4 6.5/8.7 9.8/13.0 13.1/17.4 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --4.9/6.5 6.5/8.7 12.0/16.0 15.8/21.0 --6.0 11.5 14.0 23.0 --6.0 11.5 14.0 23.0 --6.0 11.5 14.0 23.0 DD--- STD 548J WITH PWRD C.O. See Notes page 49. 56 ELEC. HTR IFM TYPE 208/230---3---60 FLA MCA MOCP WITH P.E. DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA --23.5/27.1 31.4/36.3 46.9/54.2 62.8/72.5 75.8/87.5 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 46.5 75.8/80.3 85.7/91.8 105.1/114.2 125.0/137.1 141.2/155.8 33.2 50.2/52.7 60.6/64.8 75.0/81.3 88.0/96.3 102.2/113.0 31 48.0/50.5 58.4/62.6 72.8/79.1 85.8/94.1 100.0/110.8 33.3 50.3/52.8 60.7/64.9 75.1/81.4 88.1/96.4 102.3/113.1 20.2 29.2 37.5 41.2 54.9 58.6 15.2 24.2 32.5 36.2 49.9 53.6 16 25.0 33.3 37.0 50.7 54.4 60 80/90 100/100 110/125 125/150 150/175 45 60/60 70/70 80/90 90/100 110/125 45 60/60 60/70 80/80 90/100 100/125 45 60/60 70/70 80/90 90/100 110/125 25 30 40 45 60 60 20 30 35 40 50 60 20 30 35 40 60 60 46 73/77 82/88 100/108 118/129 133/147 34 49/52 59/63 72/78 84/92 97/107 31 47/49 56/60 70/75 82/89 95/105 34 49/52 59/63 72/78 84/92 97/107 21 29 37 40 53 56 15 24 31 35 47 51 16 24 32 36 48 52 150 174/177 181/186 244/258 276/295 302/325 126 140/142 148/151 159/165 214/227 236/254 149 163/165 171/174 182/188 237/250 259/277 175 189/191 197/200 208/214 263/276 285/303 64 71 78 81 119 125 71 78 85 88 126 132 84 91 98 101 139 145 48.4 77.7/82.2 87.6/93.7 107.0/116.1 126.9/139.0 143.1/157.7 35.1 52.1/54.6 62.5/66.7 76.9/83.2 89.9/98.2 104.1/114.9 32.9 49.9/52.4 60.3/64.5 74.7/81.0 87.7/96.0 101.9/112.7 35.2 52.2/54.7 62.6/66.8 77.0/83.3 90.0/98.3 104.2/115.0 21.2 30.2 38.5 42.2 55.9 59.6 16.2 25.2 33.5 37.2 50.9 54.6 17.0 26.0 34.3 38.0 51.7 55.4 60 80/100 100/100 110/125 150/150 150/175 50 60/60 70/70 80/90 90/100 110/125 45 60/60 70/70 80/90 90/100 110/125 50 60/60 70/70 80/90 90/100 110/125 25 35 40 45 60 60 20 30 35 40 60 60 20 30 35 40 60 60 48 75/79 84/90 102/110 120/131 135/149 36 52/54 61/65 74/80 86/94 99/109 33 49/51 59/62 72/78 84/91 97/107 36 52/54 61/65 74/80 86/94 99/109 22 30 38 42 54 58 16 25 32 36 48 52 17 26 33 37 49 53 152 176/179 183/188 246/260 278/297 304/327 128 142/144 150/153 161/167 216/229 238/256 151 165/167 173/176 184/190 239/252 261/279 177 191/193 199/202 210/216 265/278 287/305 65 72 79 82 120 126 72 79 86 89 127 133 85 92 99 102 140 146 DD--- STD --- --- 13.6 15 14 47 15.5 20 16 49 MED --- --- 11.6 15 12 54 13.5 15 14 56 HIGH --- --- 12.4 15 13 65 14.3 20 15 67 DD--- STD MED 548J*06 HIGH DD--- STD 460---3---60 WITHOUT P.E. Nom (kW) --4.9/6.5 6.5/8.7 9.8/13.0 13.1/17.4 15.8/21.0 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 DD--- STD MED HIGH 575---3---60 WITH PWRD C.O. See Notes page 49. 57 548J 208/230---1---60 NOM. V ---PH ---HZ UNIT Table 47 – (cont.) MCA/MOCP DETERMINATION WITH PWRD C.O. NOM. V ---PH ---HZ UNIT Table 47 – (cont.) MCA/MOCP DETERMINATION WITH PWRD C.O. ELECTRIC HEATER IFM TYPE 548J 208/230---3---60 STD MED 548J*07 HIGH 460---3---60 STD MED 575---3---60 HIGH WITH PWRD C.O. WITHOUT P.E. Nom (kW) FLA MCA MOCP WITH P.E. DISC. SIZE FLA LRA MCA MOCP DISC. SIZE FLA LRA --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --4.9/6.5 7.9/10.5 12.0/16.0 15.8/21.0 19.9/26.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --6.0 11.5 14.0 23.0 25.5 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --13.6/15.6 21.9/25.3 33.4/38.5 43.8/50.5 55.2/63.8 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 --7.2 13.8 16.8 27.7 30.7 35.3 52.3/54.8 62.6/66.9 77.0/83.4 90.0/98.4 104.3/115.0 37.6 54.6/57.1 64.9/69.2 79.3/85.7 92.3/100.7 106.6/117.3 37.6 54.6/57.1 64.9/69.2 79.3/85.7 92.3/100.7 106.6/117.3 17.7 26.7 35.0 38.7 52.4 56.1 18.5 27.5 35.8 39.5 53.2 56.9 18.5 27.5 35.8 39.5 53.2 56.9 50 60/60 70/70 80/90 90/100 110/125 50 60/60 70/80 80/90 100/110 110/125 50 60/60 70/80 80/90 100/110 110/125 25 30 40 40 60 60 25 30 40 45 60 60 25 30 40 45 60 60 35 51/53 60/64 73/79 85/93 99/108 38 53/56 63/67 76/82 88/96 101/111 38 53/56 63/67 76/82 88/96 101/111 18 26 33 37 49 53 19 27 34 38 50 54 19 27 34 38 50 54 151 165/167 173/176 184/190 239/252 261/279 188 202/204 210/213 221/227 276/289 298/316 188 202/204 210/213 221/227 276/289 298/316 75 82 89 92 130 136 94 101 108 111 149 155 94 101 108 111 149 155 37.2 54.2/56.7 64.5/68.8 78.9/85.3 91.9/100.3 106.2/116.9 39.5 56.5/59.0 66.8/71.1 81.2/87.6 94.2/102.6 108.5/119.2 39.5 56.5/59.0 66.8/71.1 81.2/87.6 94.2/102.6 108.5/119.2 18.7 27.7 36.0 39.7 53.4 57.1 19.5 28.5 36.8 40.5 54.2 57.9 19.5 28.5 36.8 40.5 54.2 57.9 50 60/60 70/80 80/90 100/110 110/125 50 60/60 80/80 90/90 100/110 110/125 50 60/60 80/80 90/90 100/110 110/125 25 30 40 45 60 60 25 30 40 45 60 60 25 30 40 45 60 60 37 53/55 62/66 76/82 88/95 101/111 40 56/58 65/69 78/84 90/98 103/113 40 56/58 65/69 78/84 90/98 103/113 19 27 35 38 51 54 20 28 36 39 52 55 20 28 36 39 52 55 153 167/169 175/178 186/192 241/254 263/281 190 204/206 212/215 223/229 278/291 300/318 190 204/206 212/215 223/229 278/291 300/318 76 83 90 93 131 137 95 102 109 112 150 156 95 102 109 112 150 156 STD --- --- 14.0 20 14 61 15.9 20 16 63 MED --- --- 14.4 20 14 76 16.3 20 17 78 HIGH --- --- 14.4 20 14 76 16.3 20 17 78 See Notes page 49. 58 ELECTRIC HEATER IFM TYPE 208/230---3---60 STD MED HIGH 460---3---60 548J*08 STD MED HIGH 575---3---60 STD MED HIGH WITH PWRD C.O. WITHOUT P.E. Nom (kW) --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --17.0 34.0 --17.0 34.0 --17.0 34.0 FLA --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --20.4 40.9 --20.4 40.9 --20.4 40.9 MCA MOCP 42.5 69.6/73.7 84.2/90.6 107.1/117.1 125.9/138.7 153.0/170.0 44.8 71.9/76.0 86.5/92.9 109.4/119.4 128.2/141.0 155.3/172.3 44.8 71.9/76.0 86.5/92.9 109.4/119.4 128.2/141.0 155.3/172.3 20.1 41.0 44.9 61.9 69.8 82.9 20.9 41.8 45.7 62.7 70.6 83.7 20.9 41.8 45.7 62.7 70.6 83.7 15.2 40.7 66.3 15.6 41.1 66.7 15.6 41.1 66.7 50 70/80 90/100 110/125 150/150 175/175 50 80/80 90/100 110/125 150/150 175/175 50 80/80 90/100 110/125 150/150 175/175 25 45 45 70 70 90 25 45 50 70 80 90 25 45 50 70 80 90 20 45 70 20 45 70 20 45 70 WITH P.E. DISC. SIZE FLA LRA 45 70/74 83/89 105/114 122/134 147/162 48 73/76 86/92 107/116 124/136 149/165 48 73/76 86/92 107/116 124/136 149/165 21 41 44 60 67 79 22 42 45 61 68 80 22 42 45 61 68 80 16 40 63 17 40 64 17 40 64 198 220/223 231/237 250/258 265/275 375/402 235 257/260 268/274 287/295 302/312 412/439 235 257/260 268/274 287/295 302/312 412/439 97 114 117 130 137 197 116 133 136 149 156 216 116 133 136 149 156 216 79 99 120 94 114 135 94 114 135 See Notes page 49. 59 MCA MOCP 46.3 73.4/77.5 88.0/94.4 110.9/120.9 129.7/142.5 156.8/173.8 48.6 75.7/79.8 90.3/96.7 113.2/123.2 132.0/144.8 159.1/176.1 48.6 75.7/79.8 90.3/96.7 113.2/123.2 132.0/144.8 159.1/176.1 21.9 42.8 46.7 63.7 71.6 84.7 22.7 43.6 47.5 64.5 72.4 85.5 22.7 43.6 47.5 64.5 72.4 85.5 19.0 44.5 70.1 19.4 44.9 70.5 19.4 44.9 70.5 50 80/80 90/100 125/125 150/150 175/175 60 80/80 100/100 125/125 150/150 175/200 60 80/80 100/100 125/125 150/150 175/200 25 45 50 70 80 90 25 45 50 70 80 90 25 45 50 70 80 90 25 45 80 25 45 80 25 45 80 DISC. SIZE FLA LRA 49 74/78 88/94 109/118 126/138 151/167 52 77/81 91/96 112/121 129/141 154/169 52 77/81 91/96 112/121 129/141 154/169 23 43 46 62 69 81 24 44 47 63 70 82 24 44 47 63 70 82 21 44 68 21 45 68 21 45 68 202 224/227 235/241 254/262 269/279 379/406 239 261/264 272/278 291/299 306/316 416/443 239 261/264 272/278 291/299 306/316 416/443 99 116 119 132 139 199 118 135 138 151 158 218 118 135 138 151 158 218 83 103 124 98 118 139 98 118 139 548J NOM. V ---PH ---HZ UNIT Table 47 – (cont.) MCA/MOCP DETERMINATION WITH PWRD C.O. NOM. V ---PH ---HZ UNIT Table 47 – (cont.) MCA/MOCP DETERMINATION WITH PWRD C.O. ELECTRIC HEATER IFM TYPE 548J 208/230---3---60 STD MED HIGH 460---3---60 548J*09 STD MED HIGH 575---3---60 STD MED HIGH WITH PWRD C.O. WITHOUT P.E. Nom (kW) --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --7.8/10.4 12.0/16.0 18.6/24.8 24.0/32.0 31.8/42.4 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --13.9 16.5 27.8 33.0 41.7 --17.0 34.0 --17.0 34.0 --17.0 34.0 FLA --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --21.7/25.0 33.4/38.5 51.7/59.7 66.7/77.0 88.4/102.0 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --16.7 19.8 33.4 39.7 50.2 --20.4 40.9 --20.4 40.9 --20.4 40.9 MCA MOCP 46.7 73.8/78.0 88.5/94.8 111.3/121.3 130.1/143.0 157.2/174.2 49.0 76.1/80.3 90.8/97.1 113.6/123.6 132.4/145.3 159.5/176.5 49.0 76.1/80.3 90.8/97.1 113.6/123.6 132.4/145.3 159.5/176.5 21.4 42.2 46.1 63.1 71.0 84.1 22.2 43.0 46.9 63.9 71.8 84.9 22.2 43.0 46.9 63.9 71.8 84.9 17.1 42.6 68.2 17.5 43.0 68.6 17.5 43.0 68.6 60 80/80 90/100 125/125 150/150 175/175 60 80/90 100/100 125/125 150/150 175/200 60 80/90 100/100 125/125 150/150 175/200 25 45 50 70 80 90 25 45 50 70 80 90 25 45 50 70 80 90 20 45 70 20 45 70 20 45 70 WITH P.E. DISC. SIZE FLA LRA 49 74/78 88/93 109/118 126/138 151/166 52 77/81 90/96 111/120 128/140 153/169 52 77/81 90/96 111/120 128/140 153/169 23 42 45 61 68 80 23 43 46 62 69 81 23 43 46 62 69 81 18 42 65 19 42 66 19 42 66 206 228/231 239/245 258/266 273/283 383/410 243 265/268 276/282 295/303 310/320 420/447 243 265/268 276/282 295/303 310/320 420/447 102 119 122 135 142 202 121 138 141 154 161 221 121 138 141 154 161 221 87 107 128 102 122 143 102 122 143 See Notes page 49. 60 MCA MOCP 50.5 77.6/81.8 92.3/98.6 115.1/125.1 133.9/146.8 161.0/178.0 52.8 79.9/84.1 94.6/100.9 117.4/127.4 136.2/149.1 163.3/180.3 52.8 79.9/84.1 94.6/100.9 117.4/127.4 136.2/149.1 163.3/180.3 23.2 44.0 47.9 64.9 72.8 85.9 24.0 44.8 48.7 65.7 73.6 86.7 24.0 44.8 48.7 65.7 73.6 86.7 20.9 46.4 72.0 21.3 46.8 72.4 21.3 46.8 72.4 60 80/90 100/100 125/150 150/150 175/200 60 80/90 100/110 125/150 150/150 175/200 60 80/90 100/110 125/150 150/150 175/200 30 45 50 70 80 90 30 45 50 70 80 90 30 45 50 70 80 90 25 50 80 25 50 80 25 50 80 DISC. SIZE FLA LRA 53 78/82 92/98 113/122 130/142 155/171 56 81/85 95/100 116/125 133/145 158/173 56 81/85 95/100 116/125 133/145 158/173 25 44 47 63 70 82 26 45 48 64 71 83 26 45 48 64 71 83 22 46 69 23 46 70 23 46 70 210 232/235 243/249 262/270 277/287 387/414 247 269/272 280/286 299/307 314/324 424/451 247 269/272 280/286 299/307 314/324 424/451 104 121 124 137 144 204 123 140 143 156 163 223 123 140 143 156 163 223 91 111 132 106 126 147 106 126 147 548J TYPICAL WIRING DIAGRAMS C09063 Fig. 17 -- 1--Stage Cooling Typical Power Diagram 61 548J C09065 Fig. 18 -- 2--Stage Cooling Typical Power Diagram 62 548J C09067 Fig. 19 -- Multi--Protocol Option Diagram 63 64 Fig. 20 -- 1--Stage Typical Wiring Diagram 548J C09062 65 Fig. 21 -- 2--Stage Typical Wiring Diagram 548J C09064 SEQUENCE OF OPERATION Cooling, unit without economizer When thermostat calls for cooling, terminals G and Y1 are energized. The indoor-fan contactor (IFC), reversing valve solenoid (RVS) and compressor contactor are energized and indoor-fan motor, compressor, and outdoor fan starts. The outdoor fan motor runs continuously while unit is cooling. 548J Heating, unit without economizer Upon a request for heating from the space thermostat, terminal W1 will be energized with 24V. The IFC, outdoor-fan contactor (OFC), C1, and C2 will be energized. The indoor fan, outdoor fans, and compressor no. 1, and compressor no. 2 are energized and reversing valves are deenergized and switch position. If the space temperature continues to fall while W1 is energized, W2 will be energized with 24V, and the heater contactor(s) (HC) will be energized, which will energize the electric heater(s). When the space thermostat is satisfied, W2 will be deenergized first, and the electric heater(s) will be deenergized. Upon a further rise in space temperature, W1 will be deenergized. Cooling, unit with EconoMi$er IV When free cooling is not available, the compressors will be controlled by the zone thermostat. When free cooling is available, the outdoor-air damper is modulated by the EconoMi$er IV control to provide a 50 to 55_F (10_ to 13_C) mixed-air temperature into the zone. As the mixed-air temperature fluctuates above 55 or below 50_F (13_ to 10_C), the dampers will be modulated (open or close) to bring the mixed-air temperature back within control. If mechanical cooling is utilized with free cooling, the outdoor-air damper will maintain its current position at the time the compressor is started. If the increase in cooling capacity causes the mixed-air temperature to drop below 45_F (7_C), then the outdoor-air damper position will be decreased to the minimum position. If the mixed-air temperature continues to fall, the outdoor-air damper will close. Control returns to normal once the mixed-air temperature rises above 48_F (9_C). If optional power exhaust is installed, as the outdoor-air damper opens and closes, the power exhaust fans will be energized and deenergized. If field-installed accessory CO2 sensors are connected to the EconoMi$er IV control, a demand controlled ventilation strategy will begin to operate. As the CO2 level in the zone increases above the CO2 setpoint, the minimum position of the damper will be increased proportionally. As the CO2 level decreases because of the increase in fresh air, the outdoor-air damper will be proportionally closed. For EconoMi$er IV operation, there must be a thermostat call for the fan (G). If the unit is occupied and the fan is on, the damper will operate at minimum position. Otherwise, the damper will be closed. When the EconoMi$er IV control is in the occupied mode and a call for cooling exists (Y1 on the thermostat), the control will first check for indoor fan operation. If the fan is not on, then cooling will not be activated. If the fan is on, then the control will open the EconoMi$er IV damper to the minimum position. On the initial power to the EconoMi$er IV control, it will take the damper up to 21/2 minutes before it begins to position itself. Any change in damper position will take up to 30 seconds to initiate. Damper movement from full closed to full open (or vice versa) will take between 11/2 and 21/2 minutes. If free cooling can be used as determined from the appropriate changeover command (switch, dry bulb, enthalpy curve, differential dry bulb, or differential enthalpy), then the control will modulate the dampers open to maintain the mixed-air temperature setpoint at 50_ to 55_F (10_ to 13_C). If there is a further demand for cooling (cooling second stage — Y2 is energized), then the control will bring on compressor stage 1 to maintain the mixed-air temperature setpoint. The EconoMi$er IV damper will be open at maximum position. EconoMi$er IV operation is limited to a single compressor. Heating, unit with EconoMi$er When the room temperature calls for heat through terminal W1, the indoor (evaporator) fan contactor (IFC) and heater contactor no. 1 (HC1) are energized and the reversing valve(s) deenergize and switches position. On units equipped for 2 stages of heat, when additional heat is needed, heater contactor no. 2 is energized through W2. The economizer damper moves to the minimum position. When the thermostat is satisfied, the damper moves to the fully closed position. Defrost When the temperature of the outdoor coil drops below 28_F (-- 2_C) as sensed by the defrost thermostat (DFT2) and the defrost timer is at the end of a timed period (adjustable at 30, 60, 90 or 120 minutes), reversing valve solenoids (RVS1 and RVS2) are energized and the OFC is deenergized. This switches the position of the reversing valves and shuts off the outdoor fan. The electric heaters (if installed) will be energized. The unit continues to defrost until the coil temperature as measured by DFT2 reaches 65_F (18_C), or the duration of defrost cycle completes a 10-minute period. During the Defrost mode, if circuit 1 defrosts first, RVS1 will oscillate between Heating and Cooling modes until the Defrost mode is complete. 66 If the space thermostat is satisfied during a defrost cycle, the unit will continue in the Defrost mode until the time or temperature constraints are satisfied. Automatic changeover When the system selection switch is set at AUTO. position, unit automatically changes from heating operation to cooling operation when the temperature of the conditioned space rises to the cooling level setting. When the temperature of the conditioned space falls to the heating level setting, unit automatically changes from cooling to heating operation (with a 3°F deadband in between). Continuous air circulation Turn unit power on. Set system control at OFF position. Set fan switch at ON position. The indoor-fan contactor is energized through the thermostat switch and the indoor fan runs continuously. Cycle-LOC™ protection If unit operation is interrupted by an open high-pressure switch, low-pressure switch, indoor coil freeze stat, or by compressor internal line-break device (overcurrent or overtemperature), and compressor is calling for either cooling or heating, Cycle-LOC protection device simultaneously locks out unit and lights a warning light on the thermostat. Restart the unit by manually turning thermostat to OFF and then to ON position. If any of the protective devices opens again, the unit continues to lock out until corrective action is taken. NOTE: If the unit fails to operate due to compressor over-current condition, restart by manually resetting circuit breakers at the unit. Restart cannot be accomplished at the room thermostat. Emergency heat If compressor is inoperative due to a tripped safety device (high or low pressure, indoor coil freeze stat, overcurrent, or overtemperature), the Cycle-LOC device locks out the compressor and lights a warning light on the room thermostat. When the switch is on (thermostat is set to the EM HT position), compressor circuit and outdoor thermostats are bypassed, and the second stage of thermostat energizes the indoor blower and the electric resistance heaters. 67 548J At the end of the defrost cycle, the electric heaters (if installed) will be deenergized; the reversing valves switch and the outdoor-fan motor will be energized. The unit will now operate in the Heating mode. GUIDE SPECIFICATIONS -- 548J*04--09 Note about this specification: Bryant created this specification in “Masterformat” as published by the Construction Specification Institute. Please feel free to copy this specification directly into your building specifications. Rooftop Packaged Heat Pump HVAC Guide Specifications 548J Size Range: 3 to 8.5 Nominal Tons This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. Section Description 23 06 80 Schedules for Decentralized HVAC Equipment 23 06 80.13 Decentralized Unitary HVAC Equipment Schedule 23 06 80.13.A. Rooftop unit schedule 1. Schedule is per the project specification requirements. 23 07 16 HVAC Equipment Insulation 23 07 16.13 Decentralized, Rooftop Units: 23 07 16.13.A. Evaporator fan compartment: 1. Interior cabinet surfaces shall be insulated with a minimum 1/2-- in. thick, minimum 1 1/2 lb density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on the air side. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 07 16.13.B. Electric heat compartment: 1. Aluminum foil-- faced fiberglass insulation shall be used. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 09 13 Instrumentation and Control Devices for HVAC 23 09 13.23 Sensors and Transmitters 23 09 13.23.A. Thermostats 1. Thermostat must a. have capability to energize 2 different stages of cooling, and 2 different stages of heating. b. include capability for occupancy scheduling. 23 09 23 Direct-- digital Control system for HVAC 23 09 23.13 Decentralized, Rooftop Units: 23 09 23.13.A. N/A 23 09 23.13.B. Multi-- protocol, direct digital controller: 1. Shall be ASHRAE 62-- 2001 compliant. 2. Shall accept 18-- 30VAC, 50-- 60Hz, and consumer 15VA or less power. 3. Shall have an operating temperature range from - 40_F (-- 40_C) to 130_F (54_C), 10% - 90% RH (non-- condensing). 4. Shall include built-- in protocol for BACNET (MS/TP and PTP modes), Modbus (RTU and ASCII), Johnson N2 and LonWorks. LonWorks Echelon processor required for all Lon applications shall be contained in separate communication board. 5. Shall allow access of up to 62 network variables (SNVT). Shall be compatible with all open controllers 6. Baud rate Controller shall be selectable using a dipswitch. 68 23 09 33 Electric and Electronic Control System for HVAC 23 09 33.13 Decentralized, Rooftop Units: 23 09 33.13.A. General: 1. Shall be complete with self-- contained low-- voltage control circuit protected by a resettable circuit breaker on the 24-- v transformer side. Transformer shall have 75VA capability. 2. Shall utilize color-- coded wiring. 3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control functions such as: smoke detectors, phase monitor, economizer, thermostat, DDC control options, loss of charge, freeze switch, high pressure switches. 4. Unit shall include a minimum of one 8-- pin screw terminal connection board for connection of control wiring. 5. Shall include integrated defrost system to prevent excessive frost accumulation during heating duty, and shall be controlled as follows: a. Defrost shall be initiated on the basis of time and coil temperature. b. A 30,60,90,120 minute timer shall activate the defrost cycle only if the coil temperature is low enough to indicate a heavy frost condition. c. Defrost cycle shall terminate when defrost thermostat are satisfied and shall have a positive termination time of 10 minutes. 6. Defrost system shall also include: a. Defrost Cycle Indicator LED. b. Dip switch selectable defrost time between 30,60,90 and 120 minutes. Factory set at 30 minutes. c. Molded plug connection to insure proper connection. 23 09 33.23.B. Safeties: 1. Compressor over-- temperature, over current. 2. Loss of charge switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross-- wiring of the safety switches between circuits 1 and 2. b. Loss of charge switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 3. High-- pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross-- wiring of the safety switches between circuits 1 and 2. b. High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 4. Freeze protection thermostat, evaporator coil. 5. Automatic reset, motor thermal overload protector. 23 09 93 Sequence of Operations for HVAC Controls 23 09 93.13 23 09 93.13 Decentralized, Rooftop Units: INSERT SEQUENCE OF OPERATION 69 548J 7. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital outputs, and all analog inputs. 8. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, compressor lock-- out, fire shutdown, enthalpy switch, and fan status/filter status/humidity/remote occupancy. 9. Shall provide the following outputs: economizer, fan, cooling stage 1, cooling stage 2, heat stage 1, heat stage 2, heat stage 3/ exhaust/ reversing valve. 10. Shall have built-- in surge protection circuitry through solid state polyswitches. Polyswitches shall be used on incoming power and network connections. Polyswitches will return to normal when the “trip” condition clears. 11. Shall have a battery back-- up capable of a minimum of 10,000 hours of data and time clock retention during power outages. 12. Shall have built-- in support for Bryant technician tool. 13. Shall include an EIA-- 485 protocol communication port, an access port for connection of either a computer or a Bryant technician tool, an EIA-- 485 port for network communication to intelligent space sensors and displays, and a port to connect an optional LonWorks communications card. 14. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed. 23 40 13 Panel Air Filters 23 40 13.13 Decentralized, Rooftop Units: 23 40 13.13.A. Standard filter section 1. Shall consist of factory-- installed, low velocity, throwaway 2-- in. thick fiberglass filters of commercially available sizes. 2. Unit shall use only one filter size. Multiple sizes are not acceptable. 3. Filters shall be accessible through an access panel with “no-- tool” removal as described in the unit cabinet section of this specification (23 81 19.13.H). 548J 23 81 19 Self-- Contained Air Conditioners 23 81 19.13 Small-- Capacity Self-- Contained Air Conditioners (548J*04-- 09) 23 81 19.13.A. General 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a(n) hermetic scroll compressor(s) for cooling duty and heat pump for heating duty. 2. Factory assembled, single-- piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and special features required prior to field start-- up. 3. Unit shall use environmentally safe, Puron refrigerant. 4. Unit shall be installed in accordance with the manufacturer’s instructions. 5. Unit must be selected and installed in compliance with local, state, and federal codes. 23 81 19.13.B. Quality Assurance 1. Unit meets ASHRAE 90.1-- 2004 minimum efficiency requirements. 2. 3-- phase units are Energy Star qualified. 3. Unit shall be rated in accordance with AHRI Standards 210/240 and 340/360. 4. Unit shall be designed to conform to ASHRAE 15, 2001. 5. Unit shall be UL-- tested and certified in accordance with ANSI Z21.47 Standards and UL-- listed and certified under Canadian standards as a total package for safety requirements. 6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 7. Unit casing shall be capable of withstanding 500-- hour salt spray exposure per ASTM B117 (scribed specimen). 8. Unit casing shall be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 5000-- hour salt spray. 9. Unit shall be designed in accordance with ISO 9001:2000, and shall be manufactured in a facility registered by ISO 9001:2000. 10. Roof curb shall be designed to conform to NRCA Standards. 11. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit will be stored at the factory, and must be available upon request. 12. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. 13. Unit shall be constructed to prevent intrusion of snow and tested to prevent snow intrusion into the control box up to 40 mph. 14. Unit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability. 23 81 19.13.C. Delivery, Storage, and Handling 1. Unit shall be stored and handled per manufacturer’s recommendations. 2. Lifted by crane requires either shipping top panel or spreader bars. 3. Unit shall only be stored or positioned in the upright position. 23 81 19.13.D. Project Conditions 1. As specified in the contract. 23 81 19.13.E. Project Conditions 1. As specified in the contract. 23 81 19.13.F. Operating Characteristics 1. Unit shall be capable of starting and running at 115_F (46_C) ambient outdoor temperature, meeting maximum load criteria of AHRI Standard 210/240 or 340/360 at ± 10% voltage. 2. Compressor with standard controls shall be capable of operation from 25_F (-- 4_C), ambient outdoor temperatures. Accessory winter start kit is necessary if mechanically cooling at ambient temperatures below 25_F (-- 4_C). 3. Unit shall be capable of simultaneous heating duty and defrost cycle operation when using accessory electric heaters. 4. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. 70 71 548J 5. Unit shall be factory configured for vertical supply & return configurations. 6. Unit shall be field convertible from vertical to horizontal configuration 7. Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return. 23 81 19.13.G. Electrical Requirements 1. Main power supply voltage, phase, and frequency must match those required by the manufacturer. 23 81 19.13.H. Unit Cabinet 1. Unit cabinet shall be constructed of galvanized steel, and shall be bonderized and coated with a pre-- painted baked enamel finish on all externally exposed surfaces. 2. Unit cabinet exterior paint shall be: film thickness, (dry) 0.003 inches minimum, gloss (per ASTM D523, 60_F): 60, Hardness: H-- 2H Pencil hardness. 3. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2-- in. thick, 1 lb density, flexible fiberglass insulation, neoprene coated on the air side. Aluminum foil-- faced fiberglass insulation shall be used in the heat compartment. 4. Base of unit shall have a minimum of three locations for thru-- the-- base electrical connections (factory installed or field installed), standard. 5. Base Rail a. Unit shall have base rails on a minimum of 2 sides. b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging. c. Holes shall be provided in the base rail for moving the rooftop by fork truck. d. Base rail shall be a minimum of 16 gauge thickness. 6. Condensate pan and connections: a. Shall be a sloped condensate drain pan made of a non-- corrosive material. b. Shall comply with ASHRAE Standard 62. c. Shall use a 3/4” - 14 NPT drain connection, possible either through the bottom or end of the drain pan. Connection shall be made per manufacturer’s recommendations. 7. Top panel: a. Shall be a single piece top panel on 04 thru 09 sizes. 8. Electrical Connections a. All unit power wiring shall enter unit cabinet at a single, factory-- prepared, knockout location. b. Thru-- the-- base capability (1.) Standard unit shall have a thru-- the-- base electrical location(s) using a raised, embossed portion of the unit basepan. (2.) Optional, factory-- approved, water-- tight connection method must be used for thru-- the-- base electrical connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 9. Component access panels (standard) a. Cabinet panels shall be easily removable for servicing. b. Unit shall have one factory installed, tool-- less, removable, filter access panel. c. Panels covering control box, indoor fan, indoor fan motor, gas components (where applicable), and compressors shall have molded composite handles. d. Handles shall be UV modified, composite. permanently attached, and recessed into the panel. e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite collars. f. Collars shall be removable and easily replaceable using manufacturer recommended parts. 23 81 19.13.I. N/A 23 81 19.13.J. Coils 1. Standard Aluminum/Copper Coils: on all models. a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless internally grooved copper tubes with all joints brazed. b. Evaporator coils shall be leak tested to 150 psig, pressure tested to 450 psig, and qualified to UL 1995 burst test at 1775 psig. c. Condenser coils shall be leak tested to 150 psig, pressure tested to 650 psig, and qualified to UL 1995 burst test at 1980 psig. 548J 2. Optional Pre-- coated aluminum-- fin condenser coils: on all models. a. Shall have a durable epoxy-- phenolic coating to provide protection in mildly corrosive coastal environments. b. Coating shall be applied to the aluminum fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. c. Epoxy-- phenolic barrier shall minimize galvanic action between dissimilar metals. 3. Optional Copper-- fin evaporator and condenser coils: on all models. a. Shall be constructed of copper fins mechanically bonded to copper tubes and copper tube sheets. b. Galvanized steel tube sheets shall not be acceptable. c. A polymer strip shall prevent coil assembly from contacting the sheet metal coil pan to minimize potential for galvanic corrosion between coil and pan. 4. Optional E-- coated aluminum-- fin evaporator and condenser coils: on all models. a. Shall have a flexible epoxy polymer coating uniformly applied to all coil surface areas without material bridging between fins. b. Coating process shall ensure complete coil encapsulation of tubes, fins and headers. c. Color shall be high gloss black with gloss per ASTM D523-- 89. d. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas including fin edges. e. Superior hardness characteristics of 2H per ASTM D3363-- 92A and cross-- hatch adhesion of 4B-- 5B per ASTM D3359-- 93. f. Impact resistance shall be up to 160 in.-- lb (ASTM D2794-- 93). g. Humidity and water immersion resistance shall be up to minimum 1000 and 250 hours respectively (ASTM D2247-- 92 and ASTM D870-- 92). h. Corrosion durability shall be confirmed through testing to be no less than 1000 hours salt spray per ASTM B117-- 90. 23 81 19.13.K. Refrigerant Components 1. Refrigerant circuit shall include the following control, safety, and maintenance features: a. Fixed orifice metering system shall prevent mal-- distribution of two-- phase refrigerant by including multiple fixed orifice devices in each refrigeration circuit. Each orifice is to be optimized to the coil circuit it serves. b. Refrigerant filter drier. c. Service gauge connections on suction and discharge lines. d. Pressure gauge access through a specially designed access port in the top panel of the unit. e. Suction line accumulator to provide protection in all operating modes from cooling, heating and reverse cycle switching. 2. There shall be gauge line access port in the top of the rooftop, covered by a black, removable plug. a. The plug shall be easy to remove and replace. b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure gauge lines. c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading with the compressor access panel on. d. The plug shall be made of a leak proof, UV-- resistant, composite material. 3. Compressors a. Unit shall use one fully hermetic, scroll compressor for each independent refrigeration circuit. b. Models shall be available with single compressor designs on 04-- 12 models, plus additional 2 compressor (stage) models from 08-- 09 sizes. c. Compressor motors shall be cooled by refrigerant gas passing through motor windings. d. Compressors shall be internally protected from high discharge temperature conditions. e. Compressors shall be protected from an over-- temperature and over-- amperage conditions by an internal, motor overload device. f. Compressor shall be factory mounted on rubber grommets. g. Compressor motors shall have internal line break thermal, current overload and high pressure differential protection. h. Crankcase heaters shall be utilized on all models (except 04 size) to protect compressor with specific refrigerant charge. 23 81 19.13.L. Filter Section 1. Filters access is specified in the unit cabinet section of this specification. 2. Filters shall be held in place by a pivoting filter tray, facilitating easy removal and installation. 72 73 548J 3. Shall consist of factory-- installed, low velocity, throw-- away 2-- in. thick fiberglass filters. 4. Filters shall be standard, commercially available sizes. 5. Only one size filter per unit is allowed. 23 81 19.13.M. Evaporator Fan and Motor 1. Evaporator fan motor: a. Shall have permanently lubricated bearings. b. Shall have inherent automatic-- reset thermal overload protection or circuit breaker. c. Shall have a maximum continuous bhp rating for continuous duty operation; no safety factors above that rating shall be required. 2. Electric Drive (Direct Drive) X13 – 5 Speed/Torque Evaporator Fan: a. Multi speed motor with easy quick adjustment settings. b. Blower fan shall be double-- inlet type with forward-- curved blades. c. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. d. Standard on all 04-- 06 models with 208/230/1/60 operation e. Standard on all 04-- 06 3-- phase models, with optional belt drive. 3. Belt-- driven Evaporator Fan: a. Belt drive shall include an adjustable-- pitch motor pulley. b. Shall use sealed, permanently lubricated ball-- bearing type. c. Blower fan shall be double-- inlet type with forward-- curved blades. d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. e. Standard on all 07 size models. Optional on all 04-- 06 3-- phase models. 23 81 19.13.N. Condenser Fans and Motors 1. Condenser fan motors: a. Shall be a totally enclosed motor. b. Shall use permanently lubricated bearings. c. Shall have inherent thermal overload protection with an automatic reset feature. d. Shall use a shaft-- down design on 04 to 09 models. 2. Condenser Fans: a. Shall be a direct-- driven propeller type fan. b. Shall have aluminum blades riveted to corrosion-- resistant steel spiders and shall be dynamically balanced. 23 81 19.13.O. Special Features, Options and Accessories 1. Integrated Economizers: a. Integrated, gear-- driven parallel modulating blade design type capable of simultaneous economizer and compressor operation. b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall be available as a factory installed option. c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity are below setpoints. e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air stream control. f. Shall be equipped with low-- leakage dampers, not to exceed 2% leakage at 1 in. wg pressure differential. g. Shall be capable of introducing up to 100% outdoor air. h. Shall be equipped with a barometric relief damper capable of relieving up to 100% return air. i. Shall be designed to close damper(s) during loss-- of-- power situations with spring return built into motor. j. Dry bulb outdoor-- air temperature sensor shall be provided as standard. Outdoor air sensor setpoint shall be adjustable and shall range from 40 to 100_F / 4 to 38_C. Additional sensor options shall be available as accessories. k. The economizer controller shall also provide control of an accessory power exhaust unit function. Factory set at 100%, with a range of 0% to 100%. l. The economizer shall maintain minimum airflow into the building during occupied period and provide design ventilation rate for full occupancy. A remote potentiometer may be used to override the damper setpoint. m. Dampers shall be completely closed when the unit is in the unoccupied mode. 548J n. Economizer controller shall accept a 2-- 10Vdc CO2 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor-- air damper to provide ventilation based on the sensor input. o. Compressor lockout sensor shall open at 35_F (2_C) and closes at 50_F (10_C). p. Actuator shall be direct coupled to economizer gear. No linkage arms or control rods shall be acceptable. q. Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed. 2. Two-- Position Motorized Damper a. Damper shall be a Two-- Position Motorized Damper. Damper travel shall be from the full closed position to the field adjustable %-- open setpoint. b. Damper shall include adjustable damper travel from 25% to 100% (full open). c. Damper shall include single or dual blade, gear driven dampers and actuator motor. d. Actuator shall be direct coupled to damper gear. No linkage arms or control rods shall be acceptable. e. Damper will admit up to 100% outdoor air for applicable rooftop units. f. Damper shall close upon indoor (evaporator) fan shutoff and/or loss of power. g. The damper actuator shall plug into the rooftop unit’s wiring harness plug. No hard wiring shall be required. h. Outside air hood shall include aluminum water entrainment filter 3. Manual damper a. Manual damper package shall consist of damper, air inlet screen, and rain hood which can be preset to admit up to 50% outdoor air for year round ventilation. 4. Head Pressure Control Package a. Controller shall control coil head pressure by condenser-- fan speed modulation or condenser-- fan cycling and wind baffles. b. Shall consist of solid-- state control and condenser-- coil temperature sensor to maintain condensing temperature between 90_F (32_C) and 110_F (43_C) at outdoor ambient temperatures down to - 20_F (-- 29_C). 5. Condenser Coil Hail Guard Assembly a. Shall protect against damage from hail. b. Shall be louvered design. 6. Unit-- Mounted, Non-- Fused Disconnect Switch: a. Switch shall be factory-- installed, internally mounted. b. National Electric Code (NEC) and UL approved non-- fused switch shall provide unit power shutoff. c. Shall be accessible from outside the unit d. Shall provide local shutdown and lockout capability. 7. Convenience Outlet: a. Powered convenience outlet. (1.) Outlet shall be powered from main line power to the rooftop unit. (2.) Outlet shall be powered from line side or load side of disconnect by installing contractor, as required by code. If outlet is powered from load side of disconnect, unit electrical ratings shall be UL certified and rated for additional outlet amperage. (3.) Outlet shall be factory-- installed and internally mounted with easily accessible 115-- v female receptacle. (4.) Outlet shall include 15 amp GFI receptacles with independent fuse protection. (5.) Voltage required to operate convenience outlet shall be provided by a factory-- installed step-- down transformer. (6.) Outlet shall be accessible from outside the unit. b. Non-- Powered convenience outlet. (1.) Outlet shall be powered from a separate 115-- 120v power source. (2.) A transformer shall not be included. (3.) Outlet shall be factory-- installed and internally mounted with easily accessible 115-- v female receptacle. (4.) Outlet shall include 15 amp GFI receptacles. (5.) Outlet shall be accessible from outside the unit. 8. Thru-- the-- Base Connectors: a. Kits shall provide connectors to permit electrical connections to be brought to the unit through the unit basepan. b. Minimum of three connection locations per unit. 74 75 548J 9. Fan/Filter Status Switch: a. Switch shall provide status of indoor evaporator fan (ON/OFF) or filter (CLEAN/DIRTY). b. Status shall be displayed either over communication bus (when used with direct digital controls) or with an indicator light at the thermostat. 10. Propeller Power Exhaust: a. Power exhaust shall be used in conjunction with an integrated economizer. b. Independent modules for vertical or horizontal return configurations shall be available. c. Horizontal power exhaust is shall be mounted in return ductwork. d. Power exhaust shall be controlled by economizer controller operation. Exhaust fans shall be energized when dampers open past the 0-- 100% adjustable setpoint on the economizer control. 11. Roof Curbs (Vertical): a. Full perimeter roof curb with exhaust capability providing separate air streams for energy recovery from the exhaust air without supply air contamination. b. Formed galvanized steel with wood nailer strip and shall be capable of supporting entire unit weight. c. Permits installation and securing of ductwork to curb prior to mounting unit on the curb. 12. High-- Static Indoor Fan Motor(s) and Drive(s) (04-- 09): a. High-- static motor(s) and drive(s) shall be factory-- installed to provide additional performance range. 13. Thru-- the-- Bottom Utility Connectors: a. Kit shall provide connectors to permit electrical connections to be brought to the unit through the basepan. 14. Fan/Filter Status Switch: a. Provides status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY). Status shall be displayed over communication bus when used with direct digital controls or with an indicator light at the thermostat. 15. Outdoor Air Enthalpy Sensor: a. The outdoor air enthalpy sensor shall be used to provide single enthalpy control. When used in conjunction with a return air enthalpy sensor, the unit will provide differential enthalpy control. The sensor allows the unit to determine if outside air is suitable for free cooling. 16. Return Air Enthalpy Sensor: a. The return air enthalpy sensor shall be used in conjunction with an outdoor air enthalpy sensor to provide differential enthalpy control. 17. Indoor Air Quality (CO2) Sensor: a. Shall be able to provide demand ventilation indoor air quality (IAQ) control. b. The IAQ sensor shall be available in duct mount, wall mount, or wall mount with LED display. The setpoint shall have adjustment capability. 18. Smoke detectors: a. Shall be a Four-- Wire Controller and Detector. b. Shall be environmental compensated with differential sensing for reliable, stable, and drift-- free sensitivity. c. Shall use magnet-- activated test/reset sensor switches. d. Shall have tool-- less connection terminal access. e. Shall have a recessed momentary switch for testing and resetting the detector. f. Controller shall include: (1.) One set of normally open alarm initiation contacts for connection to an initiating device circuit on a fire alarm control panel. (2.) Two Form-- C auxiliary alarm relays for interface with rooftop unit or other equipment. (3.) One Form-- C supervision (trouble) relay to control the operation of the Trouble LED on a remote test/reset station. (4.) Capable of direct connection to two individual detector modules. (5.) Can be wired to up to 14 other duct smoke detectors for multiple fan shutdown applications. 19. Time Guard a. Shall prevent compressor short cycling by providing a 5-- minute delay (±2 minutes) before restarting a compressor after shutdown for any reason. b. One device shall be required per compressor. 20. Electric Heat: a. Heating Section (1.) Heater element open coil resistance wire, nickel-- chrome alloy, 0.29 inches inside diameter, strung through ceramic insulators mounted on metal frame. Coil ends are staked and welded to terminal screw slots. 548J (2.) Heater assemblies are provided with integral fusing for protection of internal heater circuits not exceeding 48 amps each. Auto reset thermo limit controls, magnetic heater contactors (24V coil) and terminal block all mounted in electric heater control box (minimum 18 ga galvanized steel) attached to end of heater assembly. E2009 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 03/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 76 Catalog No. PDS548J---01 Replaces: NEW