Download Avaya Troubleshooting Routers Troubleshooting
Transcript
Troubleshooting Routers If you want Packet Capture to copy packets from circuits in a single I/O module, use the associated slot mask listed in Table B-2. Table B-2. Determining the Slot Mask Slot No. Slot Mask 1 0x80000000 2 0x40000000 3 0x20000000 4 0x10000000 5 0x08000000 6 0x04000000 8 0x01000000 9 0x00800000 10 0x00400000 11 0x00200000 12 0x00100000 13 0x00080000 14 0x00040000 Example To load Packet Capture on slot 2, enter the following command: set wfProtocols.26.0 0x40000000;commit If you want to copy packets from more than one circuit, and the circuits are on different I/O modules, add the hexadecimal values for the associated slots listed in Table B-2, and use the sum as the slot mask. B-6 308656-14.00 Rev 00