0108
n
Add-on Selectors for the NEM Lamp Memory System
N-20AS, 20-call
N-40AS, 40-call
- INSTRUCTIONS The N-20AS and N-40AS add-on selectors are designed to function with the NEM Lamp Memory System, Type
"C" or later. Multiple add-on selectors can be added to a master station along with a variety of sub stations to
create a communication system tailored to a user's needs. All standard NEM system accessories can be used in
conjunction with the add-on selectors. Each add-on selector requires a dedicated 24V DC power supply.
1
2
NAMES & FUNCTIONS:
1. OFF button
2. Selector button
3. OFF LED
4. Directory card
5. Station selector LED
N-nAS TERMINAL DEFINITIONS:
+
Positive 24V DC
Negative
1~40 Station number
E
Common communication
V1-V4 Connects to NB-U for
A1-A4 Background Music
3
4
5
Individual Components for System:
NEM-n
Master station (10, 20, 30, 40-call sizes)
NEM-nA Master station with handset (10, 20, 30, 40-call sizes)
NA-series
Any sub station with NA, NB, or NE model number prefix
PS-2420UL 24V DC, 2A Power Supply
Other Accessory items listed in catalog or price list as compatible with the NEM series.
SPECIFICATIONS:
Power Source:
24V DC. Use PS-2420UL.
Communication Output: 500mW at 20 ohms
Communication:
Push-to-talk, release-to-listen (TALK button), or VOX handset at master (handset models only).
Hands free at sub station.
All call output:
6W in a system of up to 20 sub stations
12W in a system between 21 and 40 stations.
Calling:
Master to sub: By voice only after pretone.
Sub to master: Call button on sub activates tone and LED, remaining activated until answered.
Wiring:
2 conductors homerun to sub station, or loop multi-conductor cable with 1 common wire
plus 1 individual wire per sub station on the wire run.
Shielded cable is recommended. Use Aiphone #822202 (22AWG) or #821802 (18AWG) 2 cond.
Multiconductor: Aiphone #822210 (10 cond.), #822215 (15 cond.), #822220 (20 cond.)
Wiring Distance:
420' with 22AWG; 1,000' with 18AWG.
Pg. 1
WIRING DIAGRAMS:
NB-L #41
NA-NE #42
N-20AS/
N-40AS
NEM-40/C
NA-A #1
1
2
3
1
2
3
A
~
~
40
40
E
E
Red
Red
Blu
Org
Org
NAR-6A
BLUE
Grn
Blk
Blu
Org
Org
Grn
Grn
Blk
Brn
Red
Org
Yel
Grn
Blu
Vio
Gray
Wht
Blk
PS-2420UL
X1
X2
X3
X4
X5
X6
X7
X8
H
E
+
-
+
-
+
-
NA-AN #2
A
NE-NVP #3
Red
Green
jumper
B
C
D
E
B
C
D
E
Blu
Blk
Wiring from
Add-on Selector
WIRING NOTE:
A sub station can be wired
either to the master or to
the add-on selector.
PS-2420UL
+
-
NEM with 40+ subs using NB-U’s for Background Music
NEM
Master
V1
A1
V2
A2
V3
A3
V4
A4
Y
E
PS-2420UL
+
-
B
H
+
-
NB-U #1
BLK
BLK
YEL
RY-PA
V1
A1
V2
A2
V3
A3
V4
A4
Y
E
B
NB-U #2
Y
E
B
YEL
20 Ohm, 5W
Amplifier
63
C
63
C
25V
MUSIC
SOURCE
N-20AS
PS-2420UL
+
-
V1
A1
V2
A2
+
-
V1
A1
V2
A2
Wiring connection between NEM master and add-on selector not shown on
this diagram. For those connections, see drawing at the top of this page.
Pg. 2
TERMINAL LAYOUT:
N-20AS
Brass Jumper
-
V1
A1
V2
A2
E
E
E
E
E
E
E
E
E
E
10
9
8
7
6
5
4
3
2
1
20
19
18
17
16
15
14
13
12
11
+
+
+
N-40AS
Brass Jumper
8
7
6
5
4
3
2
1
20
19
18
17
16
15
14
13
12
11
+
9
27
26
25
24
23
22
21
40
39
38
37
36
35
34
33
32
31
Brass Jumper
Brass Jumper
Brass Jumper
+
-
V1
A1
V2
A2
V3
A3
V4
A4
E
E
E
E
E
E
E
E
E
E
+
28
+
29
+
30
Brass Jumper
+
+
10
+
+
N-nAS TERMINAL DEFINITIONS:
+
Positive 24V DC
Negative
1~40 Station number
E
Common communication
V1-V4 Connects to NB-U for
A1-A4 Background Music
OPERATION:
* POWER SWITCH ON MASTER MUST BE ON FOR SYSTEM TO BE OPERABLE.
1. When a station calls in, press the selector button corresponding to the lit LED. Station will continue to ring and
station LED will remain illuminated until the call is answered at the master or reset at the sub.
2. To speak to the person at the remote station, press the TALK button on the master, and release TALK button
to hear reply. If the master is equipped with a handset, communication can be with the handset or push-totalk. Communication via the handset is VOX (voice actuated).
3. When the conversation is completed, press the OFF button to the left of the station button that is selected.
Hang up handset.
CAUTION
* Do not connect any AC wires to any terminal on any unit, as damage may occur. Connect only specified power source to + and - terminals.
* Do not install more or different power sources than specified for the system.
* Do not attempt to install or connect wires on the NEM system while the system's power supply is plugged in.
* NEM masters and related equipment, unless specified as "weather resistant", are designed for indoor use only. Door stations (NE-DA, NE-JA,
NE-SS, NE-SSR and NE-NVP) may be installed outdoors in a protected area. Do not expose any equipment directly to rain or extreme weather
conditions.
IMPORTANT
* Any other manufacturer's products installed with the system (power supply, external device, etc.) are not covered under Aiphone's warranty.
* Do not mount NEM equipment in the following places, as it may cause the system to malfunction:
- High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature, in front of air conditioner,
inside a refrigerated area, etc.
- Places subject to moisture or humidity extremes.
- Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.
* NEM units are electronic devices, which must not be subjected to water or any other liquid.
* Severe weather conditions, such as lightning storms, may cause damage to NEM equipment. We recommend that power surge protection be
installed to minimize potential component level damage.
- Install the SA-1 surge arrestor to protect the power supply from a surge.
- Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two connected to master.).
For additional information about this system,
please refer to the standard NEM instructions.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Toll Free Technical Support:
1-800-692-0200
E-mail [email protected]