Download Infocus IN5144a
Transcript
Status Monitor <Only for IN5142, IN5144, IN5144a and IN5145> Displaying the projector condition (continued) : When the lamp is on, it displays the supplied voltage and 3rd line peripheral Celsius temperature. NOTE • Nothing is displayed on the 2nd line of the monitor, when the projector is searching for an input signal and when the USB TYPE A ports are set to normal condition. • "NO SIGNAL" is displayed on the 2nd line of the monitor (67) when the USB TYPE B port is selected. • The displayed temperature might differ from the actual peripheral temperature because the displayed temperature is measured inside of the projector. Error states: The Status Monitor displays error warnings in capital letters. To resolve the errors, refer to the sections "Related messages" (114) and "Regarding the indicator lamps" (115, 116). Displayed warnings: COVER: The lamp cover has not been securely fastened. example Refer to the blinking LAMP indicator in the table (115). FAN: The cooing fan is not operating. Refer to the blinking TEMP indicator in the table (116). LAMP: The lamp does not light. Refer to the solid LAMP indicator in the table (115). TEMP: The projector's inside becomes over heated. Refer to the solid TEMP indicator in the table (116). AIR (AIR FLOW): The internal temperature is rising. Refer to the description of the message, "CHECK THE AIR FLOW" in the table (114). COLD: The inside of the projector may be too cold. Refer to the alternate blinking LAMP and TEMP indicators in the table (116). FILTR (FILTER): It is time to clean the air filter. Refer to the blinking LAMP and TEMP indicators in the table (116). CO V E R NOTE • When one of the FAN, LAMP, COVER, or TEMP errors displays, the backlight blinks simultaneously. 21