Download Supermicro X9DBi-F

Transcript
Chapter 2: Installation
HDD LED
HDD LED
Pin Definitions (JF1)
The HDD LED connection is located
on pins 13 and 14 of JF1. Attach a
cable here to indicate HDD activity. See the table on the right for pin
definitions.
Pin#
Definition
13
3.3V SB/UID_SW
14
HD Active
NIC1/NIC2 LED Indicators
GLAN1/2 LED
Pin Definitions (JF1)
The NIC (Network Interface Controller) LED connection for GLAN Port 1 is
located on pins 11 and 12 of JF1, and
the LED connection for GLAN Port 2 is
on Pins 9 and 10. Attach the NIC LED
cables here to display network activity.
Refer to the table on the right for pin
definitions.
Pin#
Definition
9
NIC 2 Activity LED
10
NIC 2 Link LED
11
NIC 1 Activity LED
12
NIC 1 Link LED
Note: The LED indicator for
the 10G_LAN/SPF+ connector is located at LED5. Refer
to Section 2-9 for information
on LED5.
A. HDD LED/ID_UID SW PWR Standby
B. NIC1 Link/Activity LED
C. NIC2 Link/Activity LED
20
19
Ground
NMI
X
X
3.3 V
FP PWRLED
A HDD LED
X9DB3/i-(TP)F
Rev. 1.01
ID_UID_SW/3/3V Stby
B NIC1 Link LED
NIC1 Activity LED
C
NIC2 Activity LED
NIC2 Link LED
Blue+ (OH/Fan Fail/
PWR FaiL/UID LED)
Red+ (Blue LED Cathode)
Power Fail LED
3.3V
Ground
Ground
2
2-21
1
Reset
Reset Button
PWR