Download EverFocus 500GB Paragon 16
Transcript
2.3 ALARM / CONTROL CONTACTS INSTALLATION The PARAGON alarm inputs can be used to start recording or adjust the current recording rate. Furthermore, alarm reactions such as camera switching, buzzer, e-mail, and network alarm are available, as well as 4 alarm output relays if required. Additionally the PARAGON DVR provides 4 x TTL - level control outputs with similar functionality as the relay outputs. 2.3.1 Alarm Input Contacts EPARA8 provides 8 alarm inputs, EPARA16 provides 16. All inputs are programmable N.O. (Normal Open) or N.C. (Normal Closed) Inputs have to be switched by dry contacts. Alarm input with N.O. (Normal Open) contact in idle state Alarm input with N.C. (Normal Closed) contact in idle state All settings are programmed in the ALARM menu (chapter 5.5.1). 2.3.2 Control Input Contact The Control Input CTRL IN is a N.O. (Normal Open) contact. Changing to N.C. is not possible. Control Input relay in idle state The Control Input Contact CTRL IN is defined in I/O Control menu ( possible functions: 14 chapter 5.10.4) for following