Transcript
Recommended Bit Rates
Compression Frame Rate
25 - 30
15 - 20
H.264
8 - 10
2- 5
25 - 30
15 - 20
MPEG4
8 - 10
2- 5
Low Activity
Resolution
VGA/D1 720P/1.3MP 1080P/3MP
768k
2M
3M
512k
1.5M
2M
386k
1M
1.5M
256k
768k
1M
1M
3M
5M
768k
2M
4M
512k
1.5M
3M
386k
1M
2M
Activity Level
Normal Activity
Resolution
VGA/D1 720P/1.3MP 1080P/3MP
1M
3M
5M
768k
2M
4M
512k
1.5M
3M
386k
1M
2M
1.5M
4M
6M
1M
3M
5M
768k
2M
4M
512k
1.5M
3M
Very High Activity or PTZ Tours
Resolution
VGA/D1 720P/1.3MP 1080P/3MP
2M
4M
6M
1.5M
3M
5M
1M
2M
4M
768k
1.5M
3M
3M
6M
8M
2M
4M
6M
1.5M
3M
4M
1M
2M
3M
Configuring CompleteView
Once the cameras are configured with the appropriate IP address and the camera settings are correct, launch the
CompleteView System Configuration.
1.
2.
3.
4.
5.
6.
7.
8.
Select Configure Servers
Go to the Server Configuration menu
On the drop down menu select Camera
Then select Add Camera
Enter the camera name
Select from the camera model drop down menu the appropriate driver.
Enter the IP address of the camera
Select the Stream Type
a. This is the codec mentioned in the Verifying Settings through
the Web Interface
9. Enter the HTTP and RTSP
port numbers
10. Enter the Username and
Password
a. These are the
Administrator Name
and Password for
the Sony camera
11. Verify the image path
Connecting with
Camera Specific Driver
Select the appropriate Sony model
listed in the drop down menu under
Camera Model. Enter the IP
address of the camera and the
username and password. Select the
stream type being sent from the
camera to CompleteView. If
CompleteView Camera Supplement: Sony IP Cameras
Page 6