Download GUSA SPECS - Johnstone Supply
Transcript
GUSA Heating & Air Conditioning Two-Stage High Efficiency Gas-FiredFurnace ® Com fort. Q uality. Trust. Specification Sheet DE SIG N Affix this Specification Sheet, Installation Instructions, and Users Information Manual adjacent to the unit. CERTI FIE D CE R TIFIE D Input (Btu/hr) GUSA070BX35 69,000 65,200 48,000 45,200 92.0 35 - 65 3 7.1 15.0 11 X 7 1/2 1.5 - 3.0 -0.20 -0.55 -0.37 145 GUSA090BX40 92,000 87,300 64,000 60,000 92.0 35 - 65 4 6.4 15.0 11 X 9 1/2 1.5 - 4.0 -0.20 -0.55 -0.37 167 GUSA090BX50 92,000 86,000 64,000 59,800 92.0 35 - 65 4 9.0 15.0 11 X 10 3/4 2.0 - 5.0 -0.20 -0.55 -0.37 175 GUSA115BX50 115,000 109,100 80,000 76,100 92.0 35 - 65 5 8.0 15.0 11 X 10 3/4 2.0 - 5.0 -0.20 -0.55 -0.37 188 Cabinet Size Units A B C D Small 070__35 16-1/2 15 12-3/8 12-5/8 Medium 090__40 20-1/2 19 16-3/8 14-5/8 24-1/2 23 20-3/8 18-5/8 Model Number 1 2 3 Pressure3 Switch Settings Circulator Temp. Tons AC Minimum1 Maximum2 Blower Number Rated Rise at Circuit Overcurrent of 0.5" Output Input Output AFUE Range Burners Ampacity Protection Size HP (°F) ESP (Amps) (Amps) (Btu/hr) (Btu/hr) (Btu/hr) (D" x W") High Fire Rates Low Fire Rates Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower Amps. Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size. As shipped for installations below 7000 feet. Dimensions (Inches) ID ID Front Blwr Blwr Cover (Low) (High) 090__50 Large Shipping Weight (lbs) 115__50 All dimensions are in inches. DISCHARGE AIR A 28 3/4 3/4 B (DISCHARGE AIR) 3/4 2 1/2 20 3/16 C AIR INTAKE PIPE 2" PVC ALTERNATE GAS SUPPLY HOLE 14 AIR 2 1/16 VENT/FLUE PIPE 2" PVC CONDENSATE DRAIN TRAP w/ 3/4" PVC DISCHARGE (RIGHT OR LEFT SIDE) 1 3/4 LEFT SIDE DRAIN LINE HOLES 23 DRAIN TRAP CL LOW VOLTAGE ELECTRICAL HOLE 1 3/4 SIDE CUT-OUT ALTERNATE AIR INTAKE LOCATION STANDARD GAS SUPPLY HOLE 2 11/16 7 3/8 HIGH VOLTAGE ELECTRICAL HOLE 1 1/2 DISCHARGE 3/4 30 1/4 40 24 9/16 27 1/8 2 5/8 21 1/4 30 1/4 2 5/8 19 3/16 2 19 3/16 11 3/4 16 5/8 11 3/4 ALTERNATE VENT/FLUE LOCATION 4 1/8 HIGH VOLTAGE ELECTRICAL HOLE 6 1/8 RIGHT SIDE DRAIN LINE HOLES DRAIN TRAP CL LOW VOLTAGE ELECTRICAL HOLE 32 13/16 1 3/4 SIDE CUT-OUT 1 5/8 1 D BOTTOM KNOCK-OUT 23 9/16 BOTTOM KNOCK-OUT FRONT VIEW LEFT SIDE VIEW RIGHT SIDE VIEW WARNING Due to continuous engineering design and development, the information in this spec sheet is subject to change without notice. December 2001 Rev. 1 To avoid death, personal injury or property damage due to fire, do not exceed maximum recommended fuse or circuit breaker size. Amana 1810 Wilson Parkway • Fayetteville, TN 37334 11134638 GUSA Blower Performance External Static Pressure, (Inches Water Column) ( Model Heating Speed As Shipped Motor Speed ) GUSA070BX35 ( ) HIGH FIRE: Med-Lo LOW FIRE: Low GUSA090BX40 ( HIGH FIRE: Med LOW FIRE: Low ) GUSA090BX50 ( ) HIGH FIRE: Med-Lo LOW FIRE: Low GUSA115BX50 ( HIGH FIRE: Med LOW FIRE: Low NOTES: • • • • • • • ) Tons AC at 0.5" ESP CFM 0.1 0.2 0.3 0.4 0.5 Low Fire Rise High Low Fire CFM Fire Rise Rise High Low Fire CFM Fire Rise Rise High Low Fire CFM Fire Rise Rise High Low Fire CFM Fire Rise Rise 0.6 0.7 0.8 High Fire CFM CFM CFM Rise HIGH 3.5 1621 --- 37 1572 --- 38 1521 --- 39 1469 --- 40 1407 --- 42 1343 1276 1205 MED 3.0 1402 --- 42 1366 --- 43 1329 --- 45 1290 --- 46 1243 --- 48 1185 1133 1060 MED-LO 2.5 1144 36 52 1122 37 53 1086 38 55 1063 39 56 1024 40 58 981 940 875 LOW 2.0 868 48 --- 831 50 --- 805 51 --- 782 53 --- 745 55 --- 703 667 619 HIGH 4.0 1821 30 44 1768 31 45 1699 32 47 1624 34 49 1544 36 51 1439 1354 1227 MED 3.5 1624 34 49 1561 35 51 1520 36 52 1461 38 54 1381 40 57 1297 1217 1109 MED-LO 3.0 1395 40 57 1363 40 58 1311 42 60 1258 44 63 1201 46 --- 1120 1045 957 LOW 2.5 1212 45 65 1164 47 --- 1126 49 --- 1080 51 --- 1014 54 --- 957 815 HIGH 5.0 2090 --- 38 2076 --- 38 2061 --- 38 2054 --- 39 2017 --- 39 1963 1901 1820 MED 4.5 1615 --- 49 1610 --- 49 1600 --- 50 1591 --- 50 1562 35 51 1523 1473 1410 MED-LO 3.5 1367 40 58 1367 40 58 1356 41 58 1351 41 59 1345 41 59 1298 1252 1177 LOW 3.0 1191 46 --- 1182 47 --- 1166 47 --- 1141 48 --- 1115 49 --- 1061 1014 HIGH 5.0 2181 --- 45 2117 --- 47 2073 --- 48 2021 --- 49 1976 --- 50 1913 1831 1746 MED 4.5 1693 41 58 1666 41 59 1647 42 60 1600 43 62 1562 44 63 1522 1471 1408 MED-LO 3.5 1489 46 --- 1454 47 --- 1428 48 --- 1397 49 --- 1365 50 --- 1328 1270 1214 LOW 3.0 1299 53 --- 1275 54 --- 1250 55 --- 1224 56 --- 1188 58 --- 1161 1105 1059 882 965 Blower speeds for each firing rate are set independently. All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. This chart is for furnaces installed at 0 - 4000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. )indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, The shaded area ( external static pressure should not exceed 0.5” W.C. The data for 0.6” W.C. to 0.8” W.C. is shown for air conditioning purposes only. The dashed (-----) areas indicate a temperature rise not recommended for this model. The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. STANDARD ALTITUDE INSTALLATIONS For installations above 7,000 feet, please refer to your Amana distributor for required kit(s). Manifold Pressure Gas Altitude Kit Orifice Natural Propane 0-7000 0-7000 None LPTK09 #43 #55 High Stage Low Stage Pressure Switch Change 3.5" w.c. 10.0" w.c. 1.9" w.c. 6.0" w.c. None None Note: In Canada, gas furnaces are certified to 4500 feet. When installing this furnace refer to the High Altitude Chart for proper high altitude kit, if required, and gas manifold pressure. FLAME SENSOR Flame sensor output is 1 to 4 microamps at 115 volts. 2 MINIMUM CLEARANCES WARNING To avoid death, personal injury or property damage due to fire, clearances to combustible surfaces listed as below must be observed. Service Accessibility and Unit Connections • 36 inches front clearance is required for servicing or cleaning. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed below. NOTE: In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Minimum Clearances To Combustible Materials (inches) POSITION* SIDES FRONT REAR TOP BOTTOM FLUE Upflow 0 3 0 1 C 0 Horizontal 6 3 0 6 C 0 * = All positioning is determined as installed unit is viewed from the front. C = If placed on combustible floor, floor MUST be wood ONLY. FILTERS NOTE: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will accommodate the following filter sizes depending on cabinet size: Side Return(s) Bottom Return Cabinet Width (in.) Nominal Filter Size (in.) Approx. Flow Area (in2) Cabinet Width (in.) All 16 x 25 x 1 400 16-1/2 14 x 25 x 1 350 20-1/2 16 x 25 x 1 400 24-1/2 20 x 25 x 1 500 Approx. Nominal Filter Size Flow Area (in.) (in2) Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return. 3 Permanent Minimum Filter Area (in2) [Based on a 300 ft/min filter face velocity] [Based on 600 ft/min filter face velocity] 070__35 Cooling Airflow Requirement (CFM) Cooling Airflow Requirement (CFM) 800 1000 1200 1400 1600 2000 800 1000 1200 1400 1600 2000 564* 564* 564* 762 752* 752* 752* --- --- 768 --- 090__40 --- 090__50 --- --- 752* 752* 768 960 115__50 --- --- 940* 940* 940* 960 (Input_Airflow) (Input__Airflow) Disposable Minimum Filter Area (in2) 070__35 282* 282* 282* 336 376* 376* 376* --- --- 384 --- 090__40 --- 090__50 --- --- 376* 376* 384 480 115__50 --- --- 470* 470* 470* 480 Minimum filter area dictated by heating airflow requirement. *Minimum filter area dictated by heating airflow requirement. NOTE: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. FURNACE FRONT The figure below shows how the filter is retained over the bottom return air opening. CAPTIVE LANCES IN BACK PANEL FILTER RETAINER FILTER FURNACE BOTTOM Cut Away Side View of Bottom Return Wire Filter Retainer IMPORTANT NOTES: 1. All furnaces have a redundant gas valve and blower door interlock switch. 2. All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply. 3. IMPORTANT: While the data is presented as a guide, it is required to properly size fuses and wires and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4. Performance figures are based on Department of Energy information and requirements under continuous operating conditions. Performance will vary with weather conditions and use. 5. Drain connections must conform to local codes. 4 WH C HI TWO STAGE GAS VALVE 3 VT-25 C 2 BR-13 GY -12 GY-47 NO NO LOW FIRE PRESS. SWITCH BU-12 OR-15 BU-36 PK -17 L AUTO RESET PRIMARY LIMIT CONTROL VT-28 GN 1 JUNCTION BOX VT-25 2 GND LINE-H LINE-N EAC-H HI HEAT-H VT-28 BLOWER COMPARTMENT TWIN/ DEHUM W2 R W1 G BK-3 RD-15 B/C Y WH-7 PK-30 10 11 BU-12 12 GY-12 8 9 5 6 1 2 3 FP (3) 2 PK-30 2 4 WH-33 5 4 OR10 GY -8 3 24 VAC 115 VAC BK-31 LINE XFMR EAC CIRC HUM HUM XFMR LINE PARK COOL EAC HI HEAT LO HEAT HOT HLO (11) W1 40 VA TRANSFORMER NEUTRAL BK-4 WH-32 WH WH-5 WH-33 CIRCULATOR BLOWER 3 2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED 3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN 4 4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN 6 6 FLASHES = 115 VOLT AC POWER REVERSED 7 FLASHES = LOW FLAME SENSE SIGNAL CONTINUOUS FLASHES = UNANTICIPATED FLAME PRESENT 20339801 REV.00 C MVL(7) LOW FIRE PRESSURE SWITCH NO PM C PS2 (2) NO C MVC (8) HIGH FIRE PRESSURE SWITCH GND (10) TR (9) GND INTEGRATED CONTROL MODULE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) C PINK BROWN WHITE BLUE GRAY RED C NO FRONT COVER PRESSURE SWITCH JUNCTION 9 PK BR WH BU GY RD PS1 (12) HI VOLTAGE FIELD 8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING 9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPEN COLOR CODES: YL YELLOW OR ORANGE VT VIOLET GN GREEN BK BLACK G 5 BK-4 STEADY ON = REPLACE CONTROL 1 FLASH = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) TO MICRO BK-1 CHASSIS GROUND Y MVH (1) BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN) RD (LOW) W2 7 BU (MED) OR (MED-LO) MANUAL RESET ROLLOUT LIMIT CONTROL(S) HL1 (6) 6 BK (HI) 8 AUTO RESET PRIMARY LIMIT MANUAL RESETCONTROL AUXILIARY LIMIT CONTROL 24 VAC FUSE 3 A 24V THERMOSTAT CONNECTIONS WH-7 40 VA TRANSFORMER TH (5) R 1 9 CIRCUIT CONNECTOR 3 5 CIRCUIT CONNNECTOR 1 DIAGNOSTIC LED 7 XFMR-N VT-28 BK-3 2 115 VAC OR-10 RD-15 2 IGN-N HOT SURFACE IGNITER FLAME SENSOR RD-2 CAPACITOR HUM-N XFMR-H HEAT OFF DELAY DIP SWITCHES 1 IND LO HUM-H IGN-H BU-36 GN IND-N ID BLWR GY-8 T-STAT SELECTOR 0 IND HI VT-25 YL-20 TWO-STAGE INTEGRATED CONTROL MODULE COOL-H HUMIDIFIER OR-15 BR-13 CIR-N CIRCULATOR BLWR PK-30 7 4 INTEGRATED CONTROL MODULE BR-13 24 V THERMOSTAT CONNECTIONS 24 V 3A LO HEAT -H INTEGRATED CONTROL MODULE PK-30 VT-28 YL-20 MANUAL RESET AUXILIARY LIMIT CONTROL EAC-N ELECTRONIC AIR CLEANER BURNER COMPARTMENT FUSE N DISCONNECT INDUCED DRAFT BLOWER WH RD BK GND WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. CHASSIS GROUND RD -18 MANUAL RESET ROLLOUT LIMIT CONTROLS 3 WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE C FRONT COVER PRESSURE SWITCH BU -27 JUCTION BOX FLAME SENSOR C PM 1 N -5 NO OR-22 RD-2 WH-33 To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnace before servicing or performing maintenance. 1 L GND YL-20 2 HIGH FIRE PRESS. SWITCH 2 CIRCUIT CONNECTOR RD-2 WH-33 WARNING HOT SURFACE IGNITER DISCONNECT BK -1 TO 115VAC/ 1Ø / 60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE ID BLOWER TWO-STAGE PRESSURE SWITCH ASSEMBLY TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5 HI C GAS VALVE