Download GUSA SPECS - Johnstone Supply

Transcript
GUSA
Heating & Air Conditioning
Two-Stage High Efficiency
Gas-FiredFurnace
®
Com fort. Q uality. Trust.
Specification Sheet
DE SIG N
Affix this Specification Sheet, Installation Instructions,
and Users Information Manual adjacent to the unit.
CERTI FIE D
CE
R TIFIE D
Input
(Btu/hr)
GUSA070BX35
69,000
65,200
48,000
45,200
92.0
35 - 65
3
7.1
15.0
11 X 7
1/2
1.5 - 3.0
-0.20
-0.55
-0.37
145
GUSA090BX40
92,000
87,300
64,000
60,000
92.0
35 - 65
4
6.4
15.0
11 X 9
1/2
1.5 - 4.0
-0.20
-0.55
-0.37
167
GUSA090BX50
92,000
86,000
64,000
59,800
92.0
35 - 65
4
9.0
15.0
11 X 10
3/4
2.0 - 5.0
-0.20
-0.55
-0.37
175
GUSA115BX50
115,000 109,100 80,000
76,100
92.0
35 - 65
5
8.0
15.0
11 X 10
3/4
2.0 - 5.0
-0.20
-0.55
-0.37
188
Cabinet
Size
Units
A
B
C
D
Small
070__35
16-1/2
15
12-3/8 12-5/8
Medium
090__40
20-1/2
19
16-3/8 14-5/8
24-1/2
23
20-3/8 18-5/8
Model
Number
1
2
3
Pressure3
Switch Settings
Circulator
Temp.
Tons AC
Minimum1 Maximum2
Blower
Number
Rated Rise
at
Circuit
Overcurrent
of
0.5"
Output
Input
Output AFUE Range Burners Ampacity Protection
Size
HP
(°F)
ESP
(Amps)
(Amps)
(Btu/hr) (Btu/hr) (Btu/hr)
(D" x W")
High Fire
Rates
Low Fire
Rates
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower Amps.
Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.
As shipped for installations below 7000 feet.
Dimensions (Inches)
ID
ID
Front
Blwr Blwr
Cover
(Low) (High)
090__50
Large
Shipping
Weight
(lbs)
115__50
All dimensions are in inches.
DISCHARGE
AIR
A
28 3/4
3/4
B
(DISCHARGE AIR)
3/4
2 1/2
20 3/16
C
AIR INTAKE PIPE
2" PVC
ALTERNATE
GAS SUPPLY
HOLE
14
AIR
2 1/16
VENT/FLUE PIPE
2" PVC
CONDENSATE
DRAIN TRAP
w/ 3/4" PVC
DISCHARGE
(RIGHT OR
LEFT SIDE)
1 3/4
LEFT SIDE
DRAIN LINE
HOLES
23
DRAIN
TRAP
CL
LOW VOLTAGE
ELECTRICAL HOLE
1 3/4
SIDE CUT-OUT
ALTERNATE
AIR INTAKE LOCATION
STANDARD GAS
SUPPLY HOLE
2 11/16
7 3/8
HIGH VOLTAGE
ELECTRICAL HOLE
1 1/2
DISCHARGE
3/4
30 1/4
40
24 9/16
27 1/8
2 5/8
21 1/4
30 1/4
2 5/8
19 3/16
2
19 3/16
11 3/4
16 5/8
11 3/4
ALTERNATE
VENT/FLUE
LOCATION
4 1/8
HIGH VOLTAGE
ELECTRICAL HOLE
6 1/8
RIGHT SIDE
DRAIN LINE
HOLES
DRAIN
TRAP
CL
LOW VOLTAGE
ELECTRICAL HOLE
32 13/16
1 3/4
SIDE CUT-OUT
1 5/8
1
D
BOTTOM KNOCK-OUT
23 9/16
BOTTOM KNOCK-OUT
FRONT
VIEW
LEFT SIDE
VIEW
RIGHT SIDE
VIEW
WARNING
Due to continuous engineering
design and development, the
information in this spec sheet is
subject to change without notice.
December 2001
Rev. 1
To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.
Amana
1810 Wilson Parkway • Fayetteville, TN 37334
11134638
GUSA Blower Performance
External Static Pressure, (Inches Water Column)
(
Model
Heating Speed
As Shipped
Motor
Speed
)
GUSA070BX35
(
)
HIGH FIRE: Med-Lo
LOW FIRE: Low
GUSA090BX40
(
HIGH FIRE: Med
LOW FIRE: Low
)
GUSA090BX50
(
)
HIGH FIRE: Med-Lo
LOW FIRE: Low
GUSA115BX50
(
HIGH FIRE: Med
LOW FIRE: Low
NOTES:
•
•
•
•
•
•
•
)
Tons
AC
at
0.5"
ESP CFM
0.1
0.2
0.3
0.4
0.5
Low
Fire
Rise
High
Low
Fire CFM Fire
Rise
Rise
High
Low
Fire CFM Fire
Rise
Rise
High
Low
Fire CFM Fire
Rise
Rise
High
Low
Fire CFM Fire
Rise
Rise
0.6
0.7
0.8
High
Fire CFM CFM CFM
Rise
HIGH
3.5
1621
---
37
1572
---
38
1521
---
39
1469
---
40
1407
---
42
1343 1276 1205
MED
3.0
1402
---
42
1366
---
43
1329
---
45
1290
---
46
1243
---
48
1185 1133 1060
MED-LO
2.5
1144
36
52
1122
37
53
1086
38
55
1063
39
56
1024
40
58
981
940
875
LOW
2.0
868
48
---
831
50
---
805
51
---
782
53
---
745
55
---
703
667
619
HIGH
4.0
1821
30
44
1768
31
45
1699
32
47
1624
34
49
1544
36
51
1439 1354 1227
MED
3.5
1624
34
49
1561
35
51
1520
36
52
1461
38
54
1381
40
57
1297 1217 1109
MED-LO
3.0
1395
40
57
1363
40
58
1311
42
60
1258
44
63
1201
46
---
1120 1045
957
LOW
2.5
1212
45
65
1164
47
---
1126
49
---
1080
51
---
1014
54
---
957
815
HIGH
5.0
2090
---
38
2076
---
38
2061
---
38
2054
---
39
2017
---
39
1963 1901 1820
MED
4.5
1615
---
49
1610
---
49
1600
---
50
1591
---
50
1562
35
51
1523 1473 1410
MED-LO
3.5
1367
40
58
1367
40
58
1356
41
58
1351
41
59
1345
41
59
1298 1252 1177
LOW
3.0
1191
46
---
1182
47
---
1166
47
---
1141
48
---
1115
49
---
1061 1014
HIGH
5.0
2181
---
45
2117
---
47
2073
---
48
2021
---
49
1976
---
50
1913 1831 1746
MED
4.5
1693
41
58
1666
41
59
1647
42
60
1600
43
62
1562
44
63
1522 1471 1408
MED-LO
3.5
1489
46
---
1454
47
---
1428
48
---
1397
49
---
1365
50
---
1328 1270 1214
LOW
3.0
1299
53
---
1275
54
---
1250
55
---
1224
56
---
1188
58
---
1161 1105 1059
882
965
Blower speeds for each firing rate are set independently.
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
This chart is for furnaces installed at 0 - 4000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
)indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
The shaded area (
external static pressure should not exceed 0.5” W.C. The data for 0.6” W.C. to 0.8” W.C. is shown for air conditioning purposes only.
The dashed (-----) areas indicate a temperature rise not recommended for this model.
The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
STANDARD ALTITUDE INSTALLATIONS
For installations above 7,000 feet, please refer to your Amana distributor for required kit(s).
Manifold Pressure
Gas
Altitude
Kit
Orifice
Natural
Propane
0-7000
0-7000
None
LPTK09
#43
#55
High Stage
Low Stage
Pressure
Switch
Change
3.5" w.c.
10.0" w.c.
1.9" w.c.
6.0" w.c.
None
None
Note: In Canada, gas furnaces are certified to 4500 feet.
When installing this furnace refer to the High Altitude Chart for proper high altitude kit, if required, and gas manifold
pressure.
FLAME SENSOR
Flame sensor output is 1 to 4 microamps at 115 volts.
2
MINIMUM CLEARANCES
WARNING
To avoid death, personal injury or property damage due to fire, clearances to combustible
surfaces listed as below must be observed.
Service Accessibility and Unit Connections
• 36 inches front clearance is required for servicing or cleaning.
• Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed
below.
NOTE: In all cases, accessibility clearance must take precedence over clearances from the enclosure where
accessibility clearances are greater.
Minimum Clearances To Combustible Materials (inches)
POSITION* SIDES FRONT REAR TOP
BOTTOM FLUE
Upflow
0
3
0
1
C
0
Horizontal
6
3
0
6
C
0
* = All positioning is determined as installed unit is viewed from the front.
C = If placed on combustible floor, floor MUST be wood ONLY.
FILTERS
NOTE: Filters are required with this furnace and must be provided by the installer. The filters
used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without
filters will void the unit warranty.
This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will
accommodate the following filter sizes depending on cabinet size:
Side Return(s)
Bottom Return
Cabinet
Width
(in.)
Nominal
Filter Size
(in.)
Approx.
Flow Area
(in2)
Cabinet
Width
(in.)
All
16 x 25 x 1
400
16-1/2
14 x 25 x 1
350
20-1/2
16 x 25 x 1
400
24-1/2
20 x 25 x 1
500
Approx.
Nominal
Filter Size Flow Area
(in.)
(in2)
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere
in the duct system such as a central return.
3
Permanent Minimum Filter Area (in2)
[Based on a 300 ft/min filter face velocity]
[Based on 600 ft/min filter face velocity]
070__35
Cooling Airflow Requirement
(CFM)
Cooling Airflow Requirement
(CFM)
800 1000 1200 1400 1600 2000
800 1000 1200 1400 1600 2000
564* 564* 564*
762
752* 752* 752*
---
---
768
---
090__40
---
090__50
---
---
752* 752* 768
960
115__50
---
---
940* 940* 940*
960
(Input_Airflow)
(Input__Airflow)
Disposable Minimum Filter Area (in2)
070__35
282* 282* 282* 336
376* 376* 376*
---
---
384
---
090__40
---
090__50
---
---
376* 376*
384
480
115__50
---
---
470* 470* 470*
480
Minimum filter area dictated by heating airflow requirement.
*Minimum filter area dictated by heating airflow requirement.
NOTE: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900
or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.
FURNACE FRONT
The figure below shows how the filter is retained over the bottom return air opening.
CAPTIVE LANCES
IN BACK PANEL
FILTER
RETAINER
FILTER
FURNACE BOTTOM
Cut Away Side View of Bottom Return Wire Filter Retainer
IMPORTANT NOTES:
1. All furnaces have a redundant gas valve and blower door interlock switch.
2. All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.
3. IMPORTANT: While the data is presented as a guide, it is required to properly size fuses and wires and make electrical
connections in accordance with the National Electrical Code and/or all existing local codes.
4. Performance figures are based on Department of Energy information and requirements under continuous operating
conditions. Performance will vary with weather conditions and use.
5. Drain connections must conform to local codes.
4
WH
C
HI
TWO STAGE
GAS VALVE
3
VT-25
C 2
BR-13
GY
-12
GY-47
NO
NO
LOW FIRE
PRESS.
SWITCH
BU-12
OR-15
BU-36
PK
-17
L
AUTO RESET PRIMARY
LIMIT CONTROL
VT-28
GN
1
JUNCTION BOX
VT-25
2
GND
LINE-H
LINE-N
EAC-H
HI
HEAT-H
VT-28
BLOWER COMPARTMENT
TWIN/
DEHUM
W2
R
W1
G
BK-3
RD-15
B/C
Y
WH-7
PK-30
10
11
BU-12
12
GY-12
8
9
5
6
1
2
3
FP (3)
2
PK-30
2
4
WH-33
5
4
OR10
GY
-8
3
24
VAC
115
VAC
BK-31
LINE
XFMR
EAC
CIRC
HUM
HUM
XFMR
LINE
PARK
COOL
EAC
HI
HEAT
LO
HEAT
HOT
HLO (11)
W1
40 VA
TRANSFORMER
NEUTRAL
BK-4
WH-32
WH
WH-5
WH-33
CIRCULATOR
BLOWER
3
2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED
3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN
4
4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN
6
6 FLASHES = 115 VOLT AC POWER REVERSED
7 FLASHES = LOW FLAME SENSE SIGNAL
CONTINUOUS FLASHES = UNANTICIPATED FLAME PRESENT
20339801 REV.00
C
MVL(7)
LOW FIRE
PRESSURE
SWITCH
NO
PM
C
PS2 (2)
NO
C
MVC (8)
HIGH FIRE
PRESSURE SWITCH
GND (10)
TR (9)
GND
INTEGRATED CONTROL MODULE
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
EQUIPMENT GND
FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
C
PINK
BROWN
WHITE
BLUE
GRAY
RED
C
NO
FRONT COVER
PRESSURE SWITCH
JUNCTION
9
PK
BR
WH
BU
GY
RD
PS1 (12)
HI VOLTAGE FIELD
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPEN
COLOR CODES:
YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
G
5
BK-4
STEADY ON = REPLACE CONTROL
1 FLASH = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
TO
MICRO
BK-1
CHASSIS
GROUND
Y
MVH (1)
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
RD (LOW)
W2
7
BU (MED)
OR (MED-LO)
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
HL1 (6)
6
BK (HI)
8
AUTO RESET
PRIMARY LIMIT
MANUAL RESETCONTROL
AUXILIARY
LIMIT CONTROL
24 VAC
FUSE 3 A
24V THERMOSTAT CONNECTIONS
WH-7
40 VA
TRANSFORMER
TH (5)
R
1
9 CIRCUIT CONNECTOR
3
5 CIRCUIT
CONNNECTOR
1
DIAGNOSTIC
LED
7
XFMR-N
VT-28
BK-3
2
115 VAC
OR-10
RD-15
2
IGN-N
HOT SURFACE
IGNITER
FLAME SENSOR
RD-2
CAPACITOR
HUM-N
XFMR-H
HEAT OFF DELAY
DIP SWITCHES
1
IND LO
HUM-H
IGN-H
BU-36
GN
IND-N
ID
BLWR
GY-8
T-STAT SELECTOR
0
IND HI
VT-25
YL-20
TWO-STAGE
INTEGRATED
CONTROL
MODULE
COOL-H
HUMIDIFIER
OR-15
BR-13
CIR-N
CIRCULATOR
BLWR
PK-30
7
4
INTEGRATED CONTROL MODULE
BR-13
24 V THERMOSTAT CONNECTIONS
24 V
3A
LO
HEAT
-H
INTEGRATED CONTROL MODULE
PK-30
VT-28
YL-20
MANUAL RESET
AUXILIARY
LIMIT CONTROL
EAC-N
ELECTRONIC
AIR CLEANER
BURNER COMPARTMENT
FUSE
N
DISCONNECT
INDUCED
DRAFT
BLOWER
WH
RD
BK
GND
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE PROPERLY
POLARIZED AND
GROUNDED.
CHASSIS GROUND
RD
-18
MANUAL RESET ROLLOUT
LIMIT CONTROLS
3
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
C
FRONT COVER
PRESSURE SWITCH
BU
-27
JUCTION
BOX
FLAME
SENSOR
C
PM 1
N
-5
NO
OR-22
RD-2
WH-33
To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnace
before servicing or performing maintenance.
1
L
GND
YL-20
2
HIGH FIRE
PRESS. SWITCH
2 CIRCUIT
CONNECTOR
RD-2
WH-33
WARNING
HOT
SURFACE
IGNITER
DISCONNECT
BK
-1
TO 115VAC/ 1Ø / 60 HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
ID BLOWER
TWO-STAGE PRESSURE
SWITCH ASSEMBLY
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
5
HI
C
GAS
VALVE