Download GALAXY
Transcript
2 GALAXY BOILER DIMENSIONS FRONT VIEW All GG and GX(H) RIGHT SIDE GG / GX(H)-PT RIGHT SIDE GX(H)-PZT-PPZT RIGHT SIDE GX(H)-PZ GG SERIES HOT WATER BOILERS - DIMENSIONS IN INCHES A B C D E F G H J K GG-75H GG-100H GG-125H GG-150H GG-175H GG-200H GG-225H GG-250H GG-275H GG-300 23 261⁄2 193⁄4 193⁄4 193⁄4 23 261⁄2 293⁄4 293⁄4 331⁄4 131⁄4 131⁄4 131⁄4 161⁄2 161⁄2 20 20 231⁄4 231⁄4 263⁄4 5 6 6 6 6 7 7 8 8 8 463⁄8 531⁄4 531⁄4 531⁄4 531⁄4 571⁄2 571⁄2 595⁄8 595⁄8 595⁄8 3 6 ⁄4 13 13 13 13 16 16 17 17 17 8 8 8 93⁄4 93⁄4 111⁄4 111⁄4 13 13 143⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 91⁄4 A B C D E F G H J K L M GXHA-100 GXH-105 GXHA-120 GXH-125 – 23 – 23 161⁄2 161⁄2 161⁄2 161⁄2 5 5 5 6 – – 463⁄8 531⁄4 3 – 6 ⁄4 – 13 10 93⁄4 10 93⁄4 1 – 1 ⁄4 – 11⁄4 – 21⁄2 – 21⁄2 – – 31⁄2 31⁄2 – 93⁄4 – 93⁄4 1 1 – ⁄2 – ⁄2 285⁄8 – 285⁄8 – GG-325 331⁄4 263⁄4 8 661⁄8 17 143⁄4 11⁄2 11⁄2 23⁄4 91⁄4 GG-350 361⁄2 30 9 661⁄8 221⁄2 161⁄4 11⁄2 11⁄2 23⁄4 91⁄4 GG-350H GG-375H GG-399H 361⁄2 361⁄2 361⁄2 30 30 30 9 10 10 661⁄8 595⁄8 625⁄8 221⁄2 15 18 161⁄4 161⁄4 161⁄4 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 23⁄4 23⁄4 23⁄4 91⁄4 91⁄4 91⁄4 GX, GXH AND GXHA SERIES STEAM AND HOT WATER BOILERS - DIMENSIONS IN INCHES GXH-150 GXHA-160 GXH-170 261⁄2 – 261⁄2 20 20 20 7 6 7 1 55 ⁄2 – 551⁄2 14 – 14 111⁄4 113⁄4 111⁄4 1 1 ⁄4 – 11⁄4 21⁄2 – 21⁄2 31⁄2 – 31⁄2 93⁄4 – 93⁄4 1 1 ⁄2 – ⁄2 – 285⁄8 – GXH-190 GXHA-200 GXH-210 261⁄2 – 293⁄4 20 231⁄4 231⁄4 7 7 7 551⁄2 – 551⁄2 14 – 14 111⁄4 131⁄2 111⁄4 1 1 ⁄2 – 11⁄2 21⁄2 – 21⁄2 31⁄2 – 31⁄2 93⁄4 – 93⁄4 1 3 ⁄2 – ⁄4 – 285⁄8 – GX-225 293⁄4 231⁄4 8 565⁄8 14 13 11⁄2 21⁄2 31⁄2 93⁄4 3 ⁄4 – GXH-230 293⁄4 231⁄4 7 551⁄2 14 13 11⁄2 21⁄2 31⁄2 93⁄4 3 ⁄4 – GX-250 293⁄4 231⁄4 8 565⁄8 14 13 11⁄2 21⁄2 31⁄2 93⁄4 3 ⁄4 – GXH-250 GXH-275 GXH-300H 321⁄2 321⁄2 321⁄2 26 26 26 7 7 9 1 1 55 ⁄2 55 ⁄2 591⁄8 14 14 15 143⁄4 143⁄4 143⁄4 1 1 1 ⁄2 1 ⁄2 11⁄2 21⁄2 21⁄2 21⁄2 31⁄2 31⁄2 31⁄2 93⁄4 93⁄4 93⁄4 3 3 3 ⁄4 ⁄4 ⁄4 – – – GXHA Series ORIFICE SIZES AT HIGH ALTITUDES INCLUDES 4% INPUT REDUCTION FOR EACH 1000 FEET ORIFICE SIZES indicated for Sea Level are factory installed in boiler unless otherwise specified by the local authority. See VII, page 12 for burner input adjustment. GAS VALVE CONNECTION Size is 1/2" f.p.t. for all sizes up to and including GG-225 and GX-225. Larger boilers, gas valves may be 3/4" or 1/2" depending upon configuration (natural, L.P., standing pilot, IID). COMBUSTIBLE FLOOR KIT increases all height dimensions by 1". RAISED SLAB - When mounting boiler on a raised slab, the slab must extend at least 2" beyond the boiler cabinet on all sides. CHIMNEY HEIGHT: 15 ft. minimum from draft hood skirt to top of chimney. CHIMNEY INSIDE DIAMETER must be same as Dimension “C” or larger. Larger diameter and/or height may be required if two or more boilers or a boiler and another appliance are vented to a single chimney. BOILER MODEL GG/GX GAS TYPE Natural Except GG-399H Propane Natural GG-399H Propane GXH-105 Natural through 275 Propane Natural GXH-300 Propane GXH-300H Natural GG-350H Gas* Natural GXHA Propane Orifice Size for Sea Level 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 42 54 40 53 44 54 43 54 43 54 41 54 45 54 44 54 43 55 42 54 45 55 44 55 43 55 42 54 45 55 44 55 43 55 42 54 46 55 45 55 44 55 43 54 47 55 45 55 44 55 43 54 47 55 46 55 45 56 44 55 48 56 47 56 46 56 44 55 48 56 47 56 47 56 45 55 49 56 48 56 43 45 55 44 46 55 44 47 55 44 47 55 45 47 56 45 48 56 46 48 56 47 49 56 47 49 56 48 50 57 *For L.P. Propane gas, consult factory. ELEVATION–FEET