Download RFID Labeling Reference Manual
Transcript
Chapter 2 RFID PPI1 Commands Read Tag 40 Purpose This command allows data from the RFID tag (embedded in the smart label) to merge into any previously defined dynamic data field. It is equivalent to the Field Number command (^FN) except that the data come from the RFID tag. Format ^RT x, start, length, hex, retries, motion, reserved ^RT Read Tag command. x Specified Field Number (value assigned to the field). The default is 0. The acceptable value range is 0 to 9999. start Location where data will be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, start will be set to 0, regardless of the specified value. length The number of blocks to be read from the RFID tag. The PPI1 only supports Alien Technology Class 1a tags, which have only one 8–byte block. Therefore, length will be set to 1, regardless of the specified value. hex This flag indicates whether the data, after being read from the RFID tag, should be translated into hexadecimal format. The default is 0, meaning the data will not be translated. The other acceptable value is 1, meaning the data will be translated into hexadecimal format. retries The number of automatic attempts to read data from the tag if previous reads failed. The PPI1 absorbs the number and uses the value on the control panel’s LCD.