Download fit-PC4
Transcript
9 Electrical Characteristics 9.1 Absolute Maximum Ratings Operating the fit-PC4 under conditions beyond its absolute maximum ratings may damage the device. Absolute maximum ratings are limiting values to be considered individually when all other parameters are within their specified operating ranges. Functional operation and specification compliance under any absolute maximum condition, or after exposure to any of these conditions, are not guaranteed or implied. Exposure may affect device reliability. Table 27 – Absolute Maximum Ratings Parameter Main power supply voltage 9.2 Min Typ. 8.5 Max - Unit 16 V Recommended Operating Conditions Operating conditions include parameters that are under the control of the user: power-supply voltage and ambient temperature. The fit-PC4 meets all performance specifications when used within the recommended operating conditions, unless otherwise noted. Table 28 – Recommended Operating Condition Parameter Main power supply voltage 9.3 Min Typ. 10 Max 12 Unit 15 V DC Electrical Characteristics Table 29 – DC Electrical Characteristics Parameter VIH VIL VOH VOL Operating Conditions GPIOs TX Voltage Swing Input Voltage Range 9.4 Min Typ. 3.3V Digital I/O 1.5 2.4 RS232 ±5.0 -25 Max Unit - 1.5 0.4 V V V V ±5.4 - 25 V V Power Supply Fit-PC4 wall power supply: CompuLab Ltd. Input: 100-240VAC 50/60Hz Output: 12VDC 3A, 36W fit-PC4 – Hardware Specification Page 59 of 67