Server Failover Configurations
Two-Node Cluster in an Avid ISIS Environment (Redundant-Switch Configuration)
Avid network switch 2
running VRRP or HSRP
VLAN 30
Avid network switch 1
running VRRP or HSRP
VLAN 30
Interplay editing
clients
Interplay Engine cluster node 1
Private network
for heartbeat
Infortrend
Raid Array
Interplay Engine cluster node 2
LEGEND
1 GB Ethernet connection
Fibre Channel connection
The following table describes what happens in the redundant-switch configuration as a result of
an outage:
Type of Outage
Result
Hardware (CPU, network adapter,
memory, cable, power supply) fails
The cluster detects the outage and triggers failover to the remaining node.
Network switch 1 (VLAN 30) fails
External switches running VRRP/HSRP detect the outage and make the
gateway available as needed.
The Interplay Engine is still accessible.
The Interplay Engine is still accessible.
Network switch 2 (VLAN 30) fails
External switches running VRRP/HSRP detect the outage and make the
gateway available as needed.
The Interplay Engine is still accessible.