Download Lucent Technologies 555-233

Transcript
Issue 1
April 2000
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r 555-233-115
5
Multicarrier G2 Universal Module to R8r EPN
Standard Reliability
5-35
RX TX
2
1
1
2
1
2
2
1
1
2
cydf013 CJL102396
Figure Notes
1. Lightwave Transceiver
5. Optical Cross-Connect Facility
2. To EPN1 Carrier A Slot 2A02
6. 100A Lightguide Interconnect Unit
3. To EPN2 Carrier A Slot 3A02
7. TX Connector
4. Fiber Optic Cable
8. RX Connector
Figure 5-9.
Fiber Optic Connections EPN1 to EPN2
Verify Usable Circuit Pack Vintages
Verify that each G2 circuit pack reused in the upgrade conforms to the usable
vintage requirements for a Release 8 system (see Reference Guide for Circuit
Pack Vintages and Change Notices).
Remove Power-Failure Ground Wire
Remove the 10 AWG (#25) (2.6 mm2) ground wire from the power-failure transfer
unit.