Download Huawei MC509 Network Router User Manual

Transcript
HUAWEI MC509 CDMA LGA Module
AT Command Interface Specification
Serial Port Control Commands

Automatic detection of the baud rate is not supported at present. Therefore, the first
returned parameter list is blank when the test command is executed. For example:
+IPR:(),(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400)

If the physical serial port baud rate is higher than the radio bearer rate, data may be lost
when being transmitted.

After the baud rate is changed, wait for a period of time (for example, 100 ms) before
continuing the communication.
5.5.3 Parameter Description
<rate>: Specifies the baud rate. It is a decimal integer. The values are as follows:
300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400
AT+IPR without a parameter is equivalent to AT+IPR=115200.
5.6 +IFC–Command for Setting Flow Control
5.6.1 Syntax
Command
Possible Response(s)
+IFC[=<DCE_by_DTE>
<CR><LF>OK<CR><LF>
[,<DTE_by_DCE>]]
In case of an MT-related error:
<CR><LF>ERROR<CR><LF>
+IFC?
<CR><LF>+IFC:<DCE_by_DTE>,<DTE_by_DCE><
CR><LF>
<CR><LF>OK<CR><LF>
+IFC=?
<CR><LF>+IFC:(supported <DCE_by_DTE> list),
(supported <DTE_by_DCE> list)<CR><LF>
<CR><LF>OK<CR><LF>
5.6.2 Interface Description
This command sets and queries bidirectional flow control.
5.6.3 Parameter Description
<DCE_by_DTE>:
0: none (default value after startup)
Issue 01 (2011-08-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
56