Download Yamaha SRCX User`s manual
Transcript
CHAPTER2 DeviceNet Unit Dedicated command execution completion Dedicated command Even after dedicated command execution is completed, the END signal does not turn ON until the dedicated command input turns OFF. BUSY END 30ms or less 1ms or less 1ms or less 1ms or less (3) When running a command was impossible from the start (In the following cases, END will not turn ON, when running of command was impossible from the start.) • When a movement command (ABS-PT, INC-PT) was run without first completing return to origin. • When an operation start command (AUTO-R, STEP-R) was run without first completing return to origin (except when pre-operation selection parameter (singleaxis controllers : PRM48, dual-axis controllers : PRM9) was set to 1 or 3). • When an unregistered point No. was specified, and a movement command (ABSPT, INC-PT) was run. • When a dedicated command was run while in emergency stop or an interlock triggered. (except for RESET and SERVO commands) Dedicated command BUSY END 30ms or less (1) (2) (3) (4) 1ms or less 30ms or less At the rise of the dedicated command input, the END signal turns off and the BUSY signal turns on. Turns off (contact open) the custom dedicated input after the BUSY signal turns on. Wait until the BUSY signal turns off. (The BUSY signal immediately turns off since the command cannot be executed.) The END signal remains off when the BUSY signal turns off, indicating that the command could not end normally. 30