Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications CAUTION 1. Do not hold the front cover when transporting the spindle drive unit. The drive unit could fall off and cause injury. 2. Always observe the installation direction. Failure to do so could result in faults. 3. Provide the specified distance between the spindle drive unit and inner surface of the control panel or other devices. Failure to observe this could result in faults. (Note 1) When installing in a poor environment (factory with high levels of oil mist), install a filter at the intake section of the partition showed with the dashed line in (d) item (Example 2). (Note 2) Make sure that cutting chips from the drill, etc., do not enter the spindle drive unit when assembling the control panel. (Note 3) Provide means so that oil, water and cutting chips, etc., do not enter the spindle drive unit from the control panel clearances or the ceiling fan. (Note 4) When using the product in a place with high levels of harmful gases or dust, protect the spindle drive unit with air purging (feed in clean air from outside so that the pressure in the storage panel is higher than outside to prevent the entry of harmful gases or dust). (2) Installation of cooling fan Each unit (excluding types without fins) is individually provided with a cooling fan (FAN1 shown below). However, install additional fans (FAN2 shown below) by the user in consideration of operation continuity when fan stops due to degradation of the environment around the fan and improvement of maintenance. When using the totally closed type unit installation method and the box structure in which cutting oil and dust, etc., easily enters the unit's fan + fan section (a structure where the fan may stop easily due to the working environment), the user should add a fan at the FAN2 position shown on the right. Carry out forced cooling with the velocity set to 2m/s or more. Also take the serviceability into consideration in this case. Inside box Outside box Wind direction FAN1 (mounted on unit as standard) FAN2 (Additionally installed by user) * Install a finger guard for safety. (Inside box) Wind direction Power supply FAN3 (Additionally installed by user) Velocity 2m/s or higher * Install a finger guard for safety. Spindle drive Due to the structure, heat will tend to accumulate at the top of each unit. Thus, install a fan in the power distribution box to agitate the heat at the top of each unit. Front view of units A5 - 7