6 GENERAL SPECIFICATIONS 6.1 SYSTEM SPECIFICAT IONS: FCC ID: RTU-150 - AIERIT04-150 RTU-450 - AIERIT04-450 10K8FID Maximum of 6 programmable from 0 to 5 V programmable from 0 to 5 V 2 isolated latching relays 2.0A 30VDC .5A 110VDC .5A 125VAC Maximum of 6 0-5 VDC 0-20 mA 8 bits Maximum of 2 0-5 VDC 0-20 mA 8 bits FSK, 1200 BPS, proprietary ManchesterEncoded data format RS-485; 1200, 2400, 4800, or 9600 BPS; ASCII; for programming – external control utilizes RTU Modbus protocol 10-16 VDC 300uA sleep, 100 mA receive 1.5A low power transmit 2.5A high power transmit Diecast Aluminum, Weather resistant 4.5" x 3.5" x 2.2" 1.4 lb. -30 to +60 degrees Centigrade Emission designator: Digital Inputs: LOW: HIGH: Digital Outputs: UL/CSA rating: Analog Inputs: Voltage Mode Range: Current Loop Mode Range: Resolution: Analog Outputs: Analog Voltage Mode Range: Current Loop Mode Range: Resolution: Radio Communications: Serial Communications: Power Requirements: Housing: Dimensions (L x W x H): Weight: Operating Temperature: 6.2 DT X SPECIFICAT IONS: T RANSMITTER Bandspread: Freq. Stability: RF Power Out: RF Output Z: Mod. Dist.: 20 MHz 5 PPM 5 W, programmable to 2 W 50 Ohms < 4% RECEIVER Bandspread: Freq. Stability Sensitivity:. RF Input Z: Selectivity: Mod. Input Z: 100 K Ohms Audio Dist.: 20 MHz 5 PPM 3 mV 50 Ohms 70 dB @ 30 KHz 65 dB @ 25 KHz < 3% 7. INTERCONNECTS 7.1 The DATAFLOW RTU has a water resistant aluminum housing. This enclosure also provides bulkhead circular connectors and one antenna port. 4