Connection method
4.3.1 PROFIBUS-DP address and termination setting
„ CNC unit address setting
The address of the CNC unit is fixed to 2 (no hardware setting).
„ Machine control panel I/O
Set the DIP switch S1 on the PC board to a value between 3 and 32 such that each unit has a
unique value.
„ I/O module
Set the DP address switch (DIP switch) on the ET200M interface module to a value between
3 and 32 such that each unit has a unique value.
„ Converter
Set the DIP switch to a value between 3 and 32 such that each unit has a unique value.
„ Termination setting
Set the termination switch on each PROFIBUS-DP connector as given below.
Unit
INFO
Setting
CNC unit
ON
Units in between
OFF
End units
ON
• Any unit other than CNC must not have its address set to 0, 1, or 2.
• Up to 32 PROFIBUS-DP addresses are available with the YS 840DI system.
• For information on how to specify addresses in software, see Chapter 9, Hardware Configuration.