Download SATO D508 Technical data
Transcript
Unit 4: Standard Command Codes 2D50 (DATA MATRIX - ECC200) FUNCTION Specifies Data Matrix (ECC200) of 2D code. FORMAT <ESC>2D50,aa,bb,ccc,ddd <ESC>DNmmmm,n...n a = Cell width (01 to 16 dots) b = Cell height (01 to 16 dots) c = Quantity of cells per line (000 fixed) d = Quantity of cell lines (000 fixed) m = Data size (1 to 3116 bytes) n = Print data Specify 7EH, 00H when printing 00H Specify 7EH, 7EH when printing 7EH Between <ESC>A and <ESC>Z but following <ESC>H and <ESC>V. EXAMPLE Example - Cell width: 3 dots, Cell height: 3 dots. <ESC>A <ESC>V100<ESC>H200 <ESC>2D50,03,03,000,000 <ESC>DN0010,0123456789 <ESC>Z OUTPUT (4-51) NOTES When designating a parameter other than specified or when the print data quantity does not match, printing will not be performed. When selecting the print format, leave more than 2mm margin around Data Matrix to be properly read by scanner. Data Format - Numeric: 3116, Alphanumeric: 2335, Binary (01H-FFH): 1556. Refer to Appendix: Reference Table 38 for additional information. E/Pro Programming Reference 4-80 PN: 9001096E