Download Mitsubishi Electric FR-PU07BB Specifications
Transcript
Troubleshooting Status Possible causes During inverter reset Connection fault of a cable or connector The "MITSUBISHI" display remains on and it will not FR-PU07BB is connected to a accept operation. FR-D700 series inverter or an incompatible FR-A700/F700 series inverter. (Refer to page 2 for supporting models.) FR-PU07BB was connected to The "PU07BB/ an incompatible FR-E700 COMPATIBILITY/ERROR" series inverter. display remains on and it (Refer to page 2 for supporting will not accept operation. models.) FR-PU07BB cannot be operated in the battery mode. 90 Check point Check whether RES signal is ON Check that no cable damage nor connection fault of a connector is found. Check the manufacture date of inverters. Check the SERIAL number indicated on the inverter rating plate or package. Check the manufacture date of inverters. Check the SERIAL number indicated on the inverter rating plate or package. Check whether the battery of Battery exhaustion of FRFR-PU07BB is run down. PU07BB, disconnection of the Check whether the AC AC adapter adapter is disconnected. Corrective action Turn OFF the RES signal. Replacement of a cable Check for a connector connection — — Change the battery. Check for connection of the AC adapter.