Download HP Integrity rx2600 Specifications

Transcript
Operation and Maintenance Guide
HP Integrity rx2600 server and HP workstation
zx6000
Document Part Number: 5969-3163
September 2003
7KLVPDQXDOFRQWDLQVDQRYHUYLHZRIV\VWHPVSHFLILFDWLRQVLQVWUXFWLRQV
IRUUHPRYLQJDQGUHSODFLQJV\VWHPFRPSRQHQWVLQIRUPDWLRQRQ
FRQILJXULQJ\RXUV\VWHPXVLQJWKHLQFOXGHGWRROVDQGLQWHUIDFHVDQG
GHWDLOHGWURXEOHVKRRWLQJLQIRUPDWLRQ
‹+HZOHWW3DFNDUG'HYHORSPHQW&RPSDQ\/3
0LFURVRIWŠ:LQGRZVŠ:LQGRZVŠDQG:LQGRZV;3ŠDUHUHJLVWHUHGWUDGHPDUNVRI0LFURVRIW
&RUSRUDWLRQLQWKH86DQGRWKHUFRXQWULHV
,QWHOŠDQG,WDQLXPŠDUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI,QWHO&RUSRUDWLRQRULWVVXEVLGLDULHVLQWKH86
DQGRWKHUFRXQWULHV
/,18;ŠLVDUHJLVWHUHGWUDGHPDUNRI/LQXV7RUYDOGVLQWKH86DQGRWKHUFRXQWULHV
19,',$DQG19,',$4XDGURDUHUHJLVWHUHGWUDGHPDUNVRUWUDGHPDUNVRI19,',$&RUSRUDWLRQLQWKH8QLWHG
6WDWHVDQGRURWKHUFRXQWULHV
$OORWKHUSURGXFWQDPHVPHQWLRQHGKHUHLQPD\EHWUDGHPDUNVRIWKHLUUHVSHFWLYHFRPSDQLHV
+HZOHWW3DFNDUG&RPSDQ\VKDOOQRWEHOLDEOHIRUWHFKQLFDORUHGLWRULDOHUURUVRURPLVVLRQVFRQWDLQHGKHUHLQRUIRU
LQFLGHQWDORUFRQVHTXHQWLDOGDPDJHVLQFRQQHFWLRQZLWKWKHIXUQLVKLQJSHUIRUPDQFHRUXVHRIWKLVPDWHULDO7KH
LQIRUPDWLRQLQWKLVGRFXPHQWLVSURYLGHG¦DVLV§ZLWKRXWZDUUDQW\RIDQ\NLQGLQFOXGLQJEXWQRWOLPLWHGWRWKH
LPSOLHGZDUUDQWLHVRIPHUFKDQWDELOLW\DQGILWQHVVIRUDSDUWLFXODUSXUSRVHDQGLVVXEMHFWWRFKDQJHZLWKRXWQRWLFH
7KHZDUUDQWLHVIRU+3SURGXFWVDUHVHWIRUWKLQWKHH[SUHVVOLPLWHGZDUUDQW\VWDWHPHQWVDFFRPSDQ\LQJVXFK
SURGXFWV1RWKLQJKHUHLQVKRXOGEHFRQVWUXHGDVFRQVWLWXWLQJDQDGGLWLRQDOZDUUDQW\
7KLVGRFXPHQWFRQWDLQVSURSULHWDU\LQIRUPDWLRQWKDWLVSURWHFWHGE\FRS\ULJKW1RSDUWRIWKLVGRFXPHQWPD\EH
SKRWRFRSLHGUHSURGXFHGRUWUDQVODWHGWRDQRWKHUODQJXDJHZLWKRXWWKHSULRUZULWWHQFRQVHQWRI+HZOHWW3DFNDUG
&RPSDQ\
Å
WARNING: Text set off in this manner indicates that failure to follow directions could result in bodily
harm or loss of life.
Ä
CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to
equipment or loss of information.
Operation and Maintenance Guide
HP Integrity rx2600 server and HP workstation zx6000
Second Edition September 2003)
Document Part Number: 5969-3163
ii
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Important Safety Warnings
Å
WARNING: Avoid electrical shocks. To avoid electrical shock, do not open the power supplies. There
are no user-serviceable parts inside.
To avoid electrical shock and harm to your eyes by laser light, do not open the DVD laser module. The
laser module should be serviced by service personnel only. Do not attempt to make any adjustment to the
laser unit. Refer to the label on the DVD for power requirements and wavelength. This product is a class I
laser product.
Å
WARNING: Removing and Replacing the Cover. For your safety, never remove the system side cover
without first disconnecting the power cord from the power outlet and removing any connection to a
telecommunications network. If a Power Protection Device is fitted to your system, you must shut down
your computer using its on/off switch, then remove the power cord before removing the system’s side
cover. Remove the Power Protection Device cables before any servicing operation. Always replace the
side cover before switching the system on again.
Å
WARNING: Battery Safety Information. There is a danger of explosion if the battery is incorrectly
installed. For your safety, never attempt to recharge, disassemble, or burn an old battery. Replace the
battery with the same or equivalent type, as recommended by the manufacturer.
The battery in this system is a lithium battery that does not contain any heavy metals. However, to protect
the environment, do not dispose of batteries in household waste. Return used batteries either to the shop
from which you bought them, to the dealer from whom you purchased your system, or to HP so that they
can either be recycled or disposed of in the correct way. Returned batteries will be accepted free of
charge.
Å
WARNING: Avoid Burn Injuries. Some parts inside the computer will be hot. Wait approximately three
to five minutes for them to cool down before touching them.
Ä
CAUTION: Avoid Static Electricity. Static electricity can damage electronic components. Turn OFF all
equipment before installing an accessory card. Don’t let your clothes touch any accessory card. To
equalize the static electricity when replacing an accessory card, rest the accessory card bag on top of the
system unit while you are removing the card from the bag. Handle the card as little as possible and with
care.
Ä
CAUTION: Information on Ergonomic Issues. It is strongly recommended that you read the ergonomics
information, available in the “Working In Comfort” section of this manual, before using your system. You
can access more extensive ergonomics information at: ZZZKSFRPHUJR
127(5HF\FOLQJ\RXUV\VWHP+3KDVDVWURQJFRPPLWPHQWWRZDUGWKHHQYLURQPHQW<RXU+3
V\VWHPKDVEHHQGHVLJQHGWRUHVSHFWWKHHQYLURQPHQWDVPXFKDVSRVVLEOH+3FDQDOVRWDNHEDFN
\RXUROGV\VWHPIRUUHF\FOLQJZKHQLWUHDFKHVWKHHQGRILWVXVHIXOOLIH+3KDVDSURGXFW
WDNHEDFNSURJUDPLQVHYHUDOFRXQWULHV7KHFROOHFWHGHTXLSPHQWLVVHQWWRDQ+3UHF\FOLQJ
IDFLOLWLHVLQ(XURSHRUWKH86$$VPDQ\SDUWVDVSRVVLEOHDUHUHXVHG7KHUHPDLQGHULV
UHF\FOHG6SHFLDOFDUHLVWDNHQIRUEDWWHULHVDQGRWKHUSRWHQWLDOWR[LFVXEVWDQFHVWKHVHDUH
UHGXFHGLQWRQRQKDUPIXOFRPSRQHQWVWKURXJKVSHFLDOFKHPLFDOSURFHVVHV,I\RXUHTXLUHPRUH
GHWDLOVDERXWWKH+3SURGXFWWDNHEDFNSURJUDPFRQWDFW\RXUORFDOGHDOHURU\RXUQHDUHVW+3
6DOHV2IILFH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
iii
iv
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Contents
Contents
,PSRUWDQW6DIHW\:DUQLQJV LLL
1 Product Overview
6\VWHP&RQILJXUDWLRQV ¤
6\VWHP)HDWXUHV ¤
3K\VLFDO&KDUDFWHULVWLFV ¤
3RZHU6SHFLILFDWLRQV ¤
3RZHU&RQVXPSWLRQDQG&RROLQJ ¤
(QYLURQPHQWDO6SHFLILFDWLRQV ¤
)URQW3DQHO ¤
5HDU3DQHO ¤
2 Installing or Replacing Parts and Accessories
/RFDWLRQRI,QWHUQDO&RPSRQHQWVDQG&RQQHFWRUV ¤
5HPRYH5HSODFH3UHUHTXLVLWHV ¤
5HDGWKH3RZHUDQG(0,:DUQLQJDQG1RWH ¤
*DWKHU<RXU7RROV ¤
)ROORZ(OHFWURVWDWLF'LVFKDUJH(6'3UHFDXWLRQV ¤
6\VWHP&RYHUVDQG%H]HO ¤
7RZHU6\VWHP ¤
5DFNPRXQW6\VWHP ¤
5HPRYLQJ5HSODFLQJ+RWVZDSDQG+RWSOXJ'HYLFHV ¤
6\VWHP)DQV ¤
3RZHU6XSSOLHV ¤
+DUG'ULYHV ¤
5HPRYLQJ5HSODFLQJ,QWHUQDO&RPSRQHQWV ¤
$LUIORZ*XLGHV ¤
0HPRU\ ¤
$FFHVVRU\DQG*UDSKLFV&DUGV ¤
3&,$*3%DFNSODQH ¤
2SWLFDO'ULYHV ¤
0DQDJHPHQW3URFHVVRU&DUG ¤
/HG6WDWXV3DQHO ¤
3URFHVVRU ¤
6\VWHP%RDUG ¤
6\VWHP%DWWHULHV ¤
3RZHU6XSSO\,QWHUIDFH0RGXOH ¤
+DUG'ULYH%DFNSODQH ¤
3 System Configuration
([WHQVLEOH)LUPZDUH,QWHUIDFH(), ¤
$FFHVVLQJWKH(), ¤
8VLQJWKH(),VKHOO ¤
8VLQJWKH%RRW2SWLRQ0DLQWHQDQFH0HQX ¤
8VLQJWKH6\VWHP&RQILJXUDWLRQ0HQX ¤
8VLQJWKH6HFXULW\3DVVZRUG0HQX ¤
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
v
Contents
5HVHWWLQJ3DVVZRUGV ¤
0DQDJHPHQW3URFHVVRU03 ¤
03&DUG,2)XQFWLRQDOLW\ ¤
$FFHVVLQJWKH03 ¤
8VLQJWKH03&RPPDQGV ¤
%DVHERDUG0DQDJHPHQW&RQWUROOHU%0& ¤
$FFHVVLQJWKH%0& ¤
)LUPZDUHXSJUDGHV ¤
4 Troubleshooting
,GHQWLI\LQJDQG'LDJQRVLQJ+DUGZDUH3UREOHPV ¤
7KH6\VWHPHEX]]HU ¤
7KH'LDJQRVWLF/('V ¤
/$1/('V ¤
6\VWHP%RDUG'LDJQRVWLF/('V ¤
5XQQLQJ'LDJQRVWLF6RIWZDUH7RROV ¤
+3H'LDJ7RROV+DUGZDUH'LDJQRVWLFV ¤
2IIOLQH'LDJQRVWLFV(QYLURQPHQW2'( ¤
A System Accessories
*UDSKLFV&DUGV $¤
6XSSRUWHG*UDSKLFV&DUGVIRUV\VWHPVZLWKQR03FDUG$¤
6HOHFWLQJD0RQLWRU $¤
0DVV6WRUDJH $¤
6XSSRUWHG+DUG'ULYHV $¤
6XSSRUWHG2SWLFDO'ULYHV $¤
B System Board
6\VWHP%RDUG2YHUYLHZ %¤
,QWHOŠ,WDQLXPŠ3URFHVVRU %¤
3URFHVVRU%XV %¤
=;,2DQG0HPRU\&RQWUROOHU %¤
=;$*33&,%XV,QWHUIDFH%¤
'XDO6HULDO&RQWUROOHU %¤
)LHOG3URJUDPPDEOH*DWH$UUD\ %¤
%DVHERDUG0DQDJHPHQW&RQWUROOHU%¤
6&6,&RQWUROOHU%¤
,'(,QWHUIDFH%¤
%76WDQGDUG0DQDJHPHQW/$1 %¤
*%6\VWHP/$1 %¤
86%&RQQHFWRUV%¤
&KLS6SDUH)XQFWLRQDOLW\U[6\VWHPV2QO\ %¤
C Part Numbers
][:RUNVWDWLRQ3DUWV &¤
,QWHJULW\U[6HUYHU3DUWV &¤
vi
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Contents
D Event, Error and Warning Messages
(),(UURUDQG:DUQLQJ0HVVDJHV '¤
6(/DQG)3//RJ(QWULHV '¤
$FFHVVLQJWKH/RJVZLWK%0&&/,&RPPDQGV '¤
$FFHVVLQJWKH/RJVZLWK03&RPPDQGV'¤
6\VWHP6SHFLILF(YHQWV '¤
(YHQWV:LWKRXW6HQVRUV'¤
Index
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
vii
Contents
viii
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1
Product Overview
7KLVFKDSWHUSURYLGHVDQRYHUYLHZRI\RXUV\VWHP
■
V\VWHPFRQILJXUDWLRQV
■
V\VWHPIHDWXUHV
■
SK\VLFDOFKDUDFWHULVWLFV
■
SRZHUVSHFLILFDWLRQV
■
HQYLURQPHQWDOVSHFLILFDWLRQV
■
IURQWSDQHO
■
UHDUSDQHO
System Configurations
7KH+3,QWHJULW\U[VHUYHUDQG+3ZRUNVWDWLRQ][DUHDYDLODEOHLQWRZHUDQG
UDFNPRXQWFRQILJXUDWLRQV
Accessory
slots
Fan Type/
Speed
Management
Processor
Redundant
Hot-swap
Power
Supply
zx6000 workstation
Tower
3 PCI
1 AGP
Quiet/
Low
No
No
zx6000 workstation
Rack-mount
3 PCI
1 AGP
Hi Capacity/
High
Optional
Optional
Integrity rx2600 server
Tower
4 PCI
Hi Capacity/
High
Yes
Yes
Integrity rx2600 server
Rack-mount
4 PCI
Hi Capacity/
High
Yes
Yes
Configuration
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1–1
Product Overview
System Features
7KHU[DQG][DUHDYDLODEOHLQPDQ\FRQILJXUDWLRQV7KHWDEOHEHORZSURYLGHVDQ
RYHUYLHZRIWKHV\VWHPIHDWXUHV
■
)RUDFRPSOHWHDQGFXUUHQWOLVWRIVXSSRUWHGSDUWVFRPSRQHQWVDQGDFFHVVRULHVVHH
http://partsurfer.hp.com
■
)RULQIRUPDWLRQRQWKHVSHFLILFIHDWXUHVDQGFRPSRQHQWVRI\RXUV\VWHP
❏
2QV\VWHPVZLWKILUPZDUHUHYLVLRQRUORZHUXVHWKH(),infoFRPPDQG6HH
¦&RQILJXUDWLRQ&RPPDQGV§RQSDJH
❏
2QV\VWHPVZLWKILUPZDUHUHYLVLRQRUKLJKHUVHH¦$GYDQFHG6\VWHP&RQILJXUDWLRQ
0HQX§RQSDJH
Feature
Description
Processor(s)
Single or dual-processor
• Intel® Itanium® 2 processor:
• 900 MHz with 1.5 MB cache on chip
• 1 GHz with 3 MB cache on chip
• 1.3 GHz with 3 MB cache on chip
• 1.5 GHz with 6 MB cache on chip
Firmware
8 MB flash EEPROM
Configured using Extensible Firmware Interface (EFI)
Operating system
Red Hat® Linux® Advanced Workstation 2.1 for the Itanium® Processor
HP-UX 11i v2
Microsoft® Windows®:
• XP 64-Bit Edition Version 2003 (zx6000 workstation)
• Server 2003, Enterprise Edition (Integrity rx2600 server)
Main memory
Capacity:
• zx6000 workstation: 512 MB min.(2 x 256 MB)
• Integrity rx2600 server: 1 GB min. (4 x 256 MB)
• 24 GB max.
Type: PC2100 ECC registered DDR266 SDRAM
Slots: Twelve DIMM slots
Modules supported: 256MB, 512MB, 1GB, 2 GB
Bus Bandwidth: up to 8.5 GB/s
NOTE: For memory loading order and detailed memory installation,
see page 2-24.
1–2
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Product Overview
Feature
Description
Hard drives
Internal bays: 3 hot-plug SCSI disk bays
Hard disk drives supported:
• 36 GB (10k or 15k rpm)
• 73 GB (15k rpm)
• 146 GB (10k rpm)
Maximum internal storage: 438 GB
Optical drives
1 open bay for 8x slimline DVD-ROM or CD-RW/DVD-ROM
SCSI controller
Two Ultra 320 SCSI channels
One external SCSI port (rear panel):
• 68-pin standard, high density SCSI connector
• Must use cables designated as U320-capable with U320 devices
• 12 m maximum bus length
• SCSI ID:
• may not use SCSI ID 2 when a drive is installed in internal bay 2
• may use SCSI ID 2 for the external port if there is no drive in bay 2
• Termination:
• must be terminated if there are devices attached
• must not be terminated if no devices are attached (automatically
terminates if no devices are attached)
• Device support:
• LVD devices
• Legacy SE devices
• SE, narrow devices
IDE controller
Ultra ATA-100 capable controller
Supports one IDE optical drive (CD/DVD)
Graphics controllers
zx6000 workstation supports one of the following options:
• AGP graphics card (see Appendix A)
• Management Processor (MP) card VGA port
Integrity rx2600 server:
• Management Processor (MP) card VGA port
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1–3
Product Overview
Feature
Description
Accessory card slots
zx6000 workstation:
• One AGP Pro 4× 32-bit slot supporting 1.5V AGP cards
• Three 64-bit 133 MHz Peripheral Component Interconnect
(PCI-X 1.0) slots, supporting all bridges and multifunction PCI-X
devices; all three PCI-X slots comply with PCI-X 1.0 specification
Integrity rx2600 server:
• Four 64-bit 133 MHz Peripheral Component Interconnect (PCI-X 1.0)
slots
Management Processor
card
(standard on Integrity
rx2600 server, optional
on zx6000 workstation)
25-pin serial connector (with console/remote/USP extensions; requires
breakout cable)
10/100 BT Management LAN
15-pin VGA connector
Rear connectors
(labeled)
Four USB connectors:
• The graphics display port functionality on the HP Management
Processor Card is not supported on zx6000 workstations with an
AGP graphics card installed; all other HP Management Processor
Card functionality is supported
• High speed 480 Mb/sec. capable
• Full speed 12 Mb/sec. and low speed 1.5 Mb/sec.
• HP-UX supports HP USB keyboard and mouse
• Linux supports all 1.1 USB devices
• Windows supports USB keyboard and mouse,
as well as other USB devices with driver support
Two 9-pin serial ports:
• UART 16550 buffered
• RS-232-C
External 68-pin LVDS/SE SCSI connector (see SCSI controller above)
LAN connectors
• 10/100 BT Management LAN
• 10/100/1000 BT Gigabit LAN
• 10/100 BT MP Card LAN (on systems with MP card)
1–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Product Overview
Physical Characteristics
6WDQGDUGFRQILJXUDWLRQDVVKLSSHGH[FOXGLQJNH\ERDUGDQGPRQLWRU
Weight:
• Tower system
Min: 22.4 kg (49.4 lb.)
Max: 25.5 kg (56.3 lb.)
• Rack-mount system
Min: 17.5 kg (38.6 lb.)
Max: 22.2 kg (49.0 lb.)
Dimensions (DxWxH):
• Tower system
67.5 cm (26.6 in.) x 29.5 cm (11.6 in.) x 49.4 cm (19.5 in.)
• Rack-mount system
67.9 cm (26.8 in.) max. x 48.3 cm (19.0 in.) x 8.6 cm (3.4 in.)
Footprint (tower)
Rack units (rack-mount)
0.2 m2 (2.1 sq. ft.)
2U
Power Specifications
3RZHUVSHFLILFDWLRQVDUHEDVHGRQV\VWHPVZLWKRQHRUWZRSRZHUVXSSOLHVLQVWDOOHG
Peak
(15 sec.)
Max. per
PCI-X Slots
64-bit,
133MHz
Maximum
for AGP Slot
Standard
Connector
Parameter
Total Rating
Input voltage
100-127 200-250 N/A
VAC
VAC
N/A
N/A
Input frequency
50 to 60 Hz
N/A
N/A
N/A
Maximum input current1
7.2A
N/A
N/A
N/A
Maximum output power2
600W
N/A
85W total for PCI slots and
AGP slot
Max current at +12V
49A
N/A
0.5A
4.8A
Max current at -12V
0.35A
N/A
0.1A
N/A
Max current at +3.3V
34A
N/A
4.6A
12.1A
Max current at +5V
18A
31A
3A
2A
Max current at +3.3V stdby
3.5A
N/A
N/A
N/A
3.6A
&RUUHVSRQGVWRWKHPD[LPXP'&SRZHUWKHSRZHUVXSSO\FDQSURYLGHWRWKHV\VWHP
7KHZRUVWFDVHKLJKHVWFXUUHQWJLYHQWKHORZHVWLQSXWYROWDJHDQGWKHPD[LPXPLQSXWSRZHU
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1–5
Product Overview
,IDQRYHUORDGWULJJHUVWKHSRZHUVXSSO\RYHUORDGSURWHFWLRQWKHV\VWHPLVLPPHGLDWHO\SRZHUHG
RII7RUHVHWWKHSRZHUVXSSO\XQLW
'LVFRQQHFWWKHSRZHUFRUG
'HWHUPLQHZKDWFDXVHGWKHRYHUORDGE\FRQWDFWLQJDQ+3VXSSRUWUHSUHVHQWDWLYH
5HFRQQHFWWKHSRZHUFRUGWKHQUHERRWWKHV\VWHP
,IDQRYHUORDGRFFXUVWZLFHWKHUHLVDQXQGHWHFWHGVKRUWFLUFXLWVRPHZKHUH
:KHQ\RXXVHWKHIURQWSDQHOSRZHUEXWWRQWRWXUQRIIWKHV\VWHPSRZHUFRQVXPSWLRQIDOOV
EHORZWKHORZSRZHUFRQVXPSWLRQEXWGRHVQ
WUHDFK]HUR7RUHDFK]HURSRZHUFRQVXPSWLRQLQ
¦RII§PRGHHLWKHUXQSOXJWKHV\VWHPRUXVHDSRZHUEORFNZLWKDVZLWFK
Power Consumption and Cooling
7KHSRZHUFRQVXPSWLRQVOLVWHGLQWKHIROORZLQJWDEOHDUHYDOLGIRUDVWDQGDUGFRQILJXUDWLRQDV
VKLSSHGRQH*+]SURFHVVRU*%RIPHPRU\:SRZHUVXSSO\WKUHHKDUGGLVNGULYHVRQH
JUDSKLFVFDUGRQH/9'6&6,FDUG
$OOLQIRUPDWLRQLQWKLVVHFWLRQLVEDVHGRQSULPDU\SRZHUFRQVXPSWLRQVZLWKRQHSRZHUVXSSO\
LQVWDOOHG
Additional Component
• Processor
• SCSI hard
• SCSI hard
• PCI card
• AGP card
1–6
Power Consumption
130W
disk drive (with I/O access) 23W
16W
disk (idle)
10W to 25W
70W
443.6 Btu/h
78.4 Btu/h
54.5 Btu/h
34.12 Btu/h to 85.30 Btu/h
238.4 Btu/h
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Product Overview
Environmental Specifications
2SHUDWLQJWHPSHUDWXUHDQGKXPLGLW\UDQJHVPD\YDU\GHSHQGLQJRQWKHLQVWDOOHGPDVVVWRUDJH
GHYLFHV+LJKKXPLGLW\OHYHOVFDQFDXVHLPSURSHUGLVNRSHUDWLRQ/RZKXPLGLW\OHYHOVFDQ
DJJUDYDWHVWDWLFHOHFWULFLW\SUREOHPVDQGFDXVHH[FHVVLYHZHDURIWKHGLVNVXUIDFH
Environmental specifications (system processing unit with hard disk)
Operating temperature
+5° C to +35° C (+41° F to +95° F)
Storage temperature
-40° C to +70° C (-40° F to +158° F)
Over-temperature shutdown
+40° C (+104° F)
Operating humidity
15% to 80% relative (noncondensing)
Storage humidity
8% to 85% relative (noncondensing)
Acoustic noise emission (ISO 7779)
Tower System:
Sound power level3
• Typical configuration1 (disk idle)
• Maximum configuration2 (disk idle)
• Maximum configuration2 (disk active)
Rack System:
• Typical configuration1 (disk idle)
• Maximum configuration2 (disk idle)
• Maximum configuration2 (disk active)
LwA4 =5.1 BA
LwA =5.4 BA
LwA =6.2 BA
LwA =6.4 BA
LwA =6.4 BA
LwA =7.2 BA
Operating altitude
3048 m (10,000 ft.) max
Storage altitude
4600 m (15,000 ft.) max
4.
6LQJOHSURFHVVRURQHWRWZR6&6,KDUGGLVNGULYHVDQGOHVVWKDQ*%RIPHPRU\
'XDOSURFHVVRURQHWRWZR6&6,KDUGGLVNGULYHVDQGOHVVWKDQ*%RIPHPRU\
7\SLFDOFRQILJXUDWLRQDWURRPWHPSHUDWXUHƒ&
LwA = A-weighted sound power level in dB(A)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1–7
Product Overview
Front Panel
7KHIURQWSDQHOVRIWKHU[DQG][KDYHWKHIROORZLQJIHDWXUHV
■
3RZHU/('LVJUHHQZKHQWKHSRZHULVRQRUWKHSRZHUEXWWRQLVSXVKHGLQ,IWKHSRZHULV
RQDQGWKHEXWWRQLVSXVKHGLQWKHOLJKWVWD\VRQHYHQDIWHUWKHV\VWHPLVSRZHUHGGRZQ
:KHQWKHEXWWRQLVUHOHDVHGWKHJUHHQOLJKWWXUQVRII
■
3RZHU%XWWRQWXUQVWKHV\VWHPSRZHURQDQGRII
■
/$1/('LQGLFDWHVFRPPXQLFDWLRQRYHUWKH*LJDELWRU0DQDJHPHQW/$1
■
6\VWHPDQG'LDJQRVWLF/('VLGHQWLI\HUURUVRQ][ZRUNVWDWLRQVZLWKQR03FDUG
■
/RFDWRU/('DQG%XWWRQUDFNPRXQWFRQILJXUDWLRQRQO\LGHQWLI\WKHUDFNSRVLWLRQRIWKH
V\VWHP
■
'LVN$FWLYLW\/('VRQHDFKKDUGGULYHWXUQJUHHQZKHQWKHGLVNLVDFFHVVHG
■
HEX]]HULFRQLQGLFDWHVWKHSRVLWLRQRIWKHLQWHUQDOVSHDNHU
7
6
5
4
3
1
Front Panel, Tower Configuration
1 2
3
4 5
6 7
Front Panel, Rack-mounted Configuration
1 e-buzzer icon
5 System LED
2 Locator LED and button (rack-mounted system only)
6 Power button
3 Diagnostic LEDs 1-4 (active only on zx6000
workstations with no MP card installed)
7 Power LED
4 LAN LED
1–8
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Product Overview
Rear Panel
7KHUHDUSDQHOKDVWKHIROORZLQJIHDWXUHV
■
&RQQHFWRUVDUHVKDSHGWRJRLQRQHZD\RQO\WRSUHYHQWLPSURSHUFDEOHDWWDFKPHQW
■
3RUWVDUHODEHOHGIRUHDV\LGHQWLILFDWLRQ
■
0DQDJHPHQW3URFHVVRU03SRUWVDUHSRVLWLRQHGDERYHUDFNPRXQWRUWRWKHULJKWRI
WRZHUVWDQGDUGFRQQHFWRUVRSWLRQDORQ][ZRUNVWDWLRQ
■
/$1/('VSURYLGHDGGLWLRQDOLQIRUPDWLRQ
❏
)RXU*LJDELW/$1/('V
❏
7ZR6\VWHP0DQDJHPHQW/$1/('V
❏
)RXU03/$1/('VRSWLRQDORQ][ZRUNVWDWLRQ
■
0RQLWRU&RQQHFWRURQJUDSKLFVFDUG][ZRUNVWDWLRQVPD\LQFOXGHJUDSKLFVFDUGV
ZLWKVLQJOHRUPXOWLSOHPRQLWRUVXSSRUW
■
/RFDWRU/('UDFNPRXQWFRQILJXUDWLRQRQO\LGHQWLILHVWKHUDFNSRVLWLRQRIWKHV\VWHP
1
3
2
14
4
13 12 11 10 9
56
7
8
Rear Panel Connectors
Ä
1 Power (PWR2)
8 USB ports (mouse and keyboard ports labelled)
2 Power (PWR1)
9 TOC button
3 MP card: VGA, serial, LAN, reset
(optional on zx6000 workstation)
10 Locator LED and button
4 System lock
11 10/100 BT Management LAN with integrated LEDs
5 Serial port A (console)
12 10/100/1000 BT Gigabit LAN LEDs
6 Serial port B
13 10/100/1000 BT Gigabit LAN
7 Monitor connector(s)
(zx6000 workstation only)
14 LVD/SE SCSI
CAUTION: Do not connect a SCSI terminator to the SCSI connector on the back of the system; the
connector is automatically terminated. If an external SCSI device is the last device connected externally to
the system, you must connect a SCSI terminator to that device.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
1–9
Product Overview
1–10
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2
Installing or Replacing Parts and Accessories
7KLVFKDSWHUSURYLGHVLQIRUPDWLRQRQ
■
/RFDWLRQRI,QWHUQDO&RPSRQHQWVDQG&RQQHFWRUV
■
5HPRYH5HSODFH3UHUHTXLVLWHV
■
6\VWHP&RYHUVDQG%H]HO
■
5HPRYLQJ5HSODFLQJ+RWVZDSDQG+RWSOXJ'HYLFHV
■
5HPRYLQJ5HSODFLQJ,QWHUQDO&RPSRQHQWV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–1
Installing or Replacing Parts and Accessories
Location of Internal Components and Connectors
15
1
14
13
2
12
3
11
10
4
9
5
8
7
6
Internal Physical Layout (front of system at bottom of photo)
1 Power receptacles (PWR1 left, PWR2 right)
9 Hard disk lock
2 HP ZX1 memory and I/O controller
10 Memory fan(s)
3 Airflow guide
11 PCI fan
4 System fans (1A right, 1B left)
12 Intrusion switch
5 Slimline optical drive
13 Memory slots
6 Power supplies
(PSU1 center, PSU2 under optical drive)
14 PCI/AGP cage
7 Status panel board
15 Management Processor (MP) card
(optional)
8 Hot-swappable hard drives (up to 3)
2–2
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
23
22
1
2
21
20
19
3
18
4
5
17
6
7
16
15
14
13
12
11
10
9
8
System Board Connectors and Slots (front of system at bottom of photo)
1 External SCSI connector
13 Status panel connector
2 SCSI connectors A & B
14 Control and standy power connector
3 Processor power Pod(s)
15 SCSI backplane power connector
4 CPU1 (empty socket)
16 PCI/Memory fan cable connector
5 CPU0 (processor under Turbo Fan)
17 PCI/AGP backplane connector
6 Turbo fan power connectors
18 Optical drive connector
7 Five VRM cards
19 Management Processor card
connector
8 Battery
20 HP ZX1 I/O adapter
9 System fan connector
21 Serial ports (2)
10 Main power connector
22 USB connectors (4)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–3
Installing or Replacing Parts and Accessories
11 HP ZX1Memory and I/O Controller (under heatsink)
23 LAN Connectors (2)
12 Memory Slots
2–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Remove/Replace Prerequisites
%HIRUH\RXUHPRYHRUUHSODFHSDUWV\RXPXVW
■
5HDGWKHSRZHUDQG(0,ZDUQLQJDQGQRWHEHORZ<RXUVDIHW\LVLPSRUWDQW
■
*DWKHU\RXUWRROV
■
)ROORZHOHFWURVWDWLFGLVFKDUJH(6'SUHFDXWLRQV
Read the Power and EMI Warning and Note
Å
Ä
WARNING: For most of the installation and removal procedures in this chapter, you must:
1.
Power off the system.
2.
Unplug the system power cord from the AC power outlet.
CAUTION: To maintain FCC Electromagnetic Interference (EMI) compliance, verify that all covers are
replaced and that all screws are properly seated.
Gather Your Tools
<RXQHHG
■
)ODWEODGHVFUHZGULYHU
■
77RU[GULYHU
■
6SHFLDOSURFHVVRUWRRO+3SDUWQXPEHU$
■
6WDWLFIUHHPDW
■
6WDWLFVWUDS
Follow Electrostatic Discharge (ESD) Precautions
7RSUHYHQWGDPDJHWRWKLVV\VWHPREVHUYHDOORIWKHIROORZLQJ(6'SUHFDXWLRQVZKLOH
SHUIRUPLQJWKHV\VWHPSDUWVUHPRYDOUHSODFHPHQWSURFHGXUHV
■
:RUNRQDVWDWLFIUHHPDW
■
:HDUDVWDWLFVWUDSWRHQVXUHWKDWDQ\DFFXPXODWHGHOHFWURVWDWLFFKDUJHLVGLVFKDUJHGIURP
\RXUERG\WRJURXQG
■
&UHDWHDFRPPRQJURXQGIRUWKHHTXLSPHQW\RXDUHZRUNLQJRQE\FRQQHFWLQJWKHVWDWLFIUHH
PDWVWDWLFVWUDSDQGSHULSKHUDOXQLWVWRWKDWSLHFHRIHTXLSPHQW
■
.HHSXQLQVWDOOHGSULQWHGFLUFXLWERDUGVLQWKHLUSURWHFWLYHDQWLVWDWLFEDJV
■
+DQGOHSULQWHGFLUFXLWERDUGVE\WKHLUHGJHVRQFH\RXKDYHUHPRYHGWKHPIURPWKHLU
SURWHFWLYHDQWLVWDWLFEDJV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–5
Installing or Replacing Parts and Accessories
System Covers and Bezel
7RXSJUDGHUHPRYHRUUHSODFHPRVWV\VWHPFRPSRQHQWV\RXPXVWILUVWUHPRYHWKHFRYHUVIURP
WKHV\VWHPFKDVVLV7KLVVHFWLRQH[SODLQVKRZWRUHPRYHDQGUHSODFHWKHFRYHUVIRUERWKWRZHU
DQGUDFNPRXQWFRQILJXUDWLRQV
Å
WARNING: Do not remove the system cover(s) without first turning the system off and unplugging the
power cord from the outlet or Power Protection Device unless you are only replacing a hot-swappable fan.
Always replace the cover(s) before turning the system on.
Tower System
7RDFFHVVWKHLQWHUQDOFRPSRQHQWVRQDWRZHUV\VWHP\RXPXVWUHPRYHWKHSODVWLFDQGPHWDO
OHIWVLGHFRYHUV
Removing the Side Covers
7XUQRIIWKHV\VWHPDQGGLVFRQQHFWWKHSRZHUFDEOHDQGDOORWKHUFDEOHVIURPWKHEDFNRI
WKHV\VWHP
127(,I\RXDUHUHPRYLQJRQO\DKRWVZDSSDEOHV\VWHPIDQRUDKRWSOXJKDUGGULYH\RXFDQ
OHDYHWKHV\VWHPRQDQGWKHSRZHUFDEOHVFRQQHFWHG
5HPRYHWKHSODVWLFFRYHU
D *UDVSERWKLQGHQWDWLRQVDWWKHWRSRIWKHVLGHSDQHODQGSXOORXWZDUG
E /LIWWKHSODVWLFFRYHURIIRIWKHV\VWHPFKDVVLV
Removing the Left-side Panel
2–6
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
5HPRYHWKHPHWDOFRYHU
D 7XUQWKHWRSFRYHUORFNNH\VZLWFKLVLQWKHXQORFNHGSRVLWLRQ
E 5RWDWHWKHEOXHUHOHDVHKDQGOHWRUHOHDVHWKHODWFK
F Slide the cover toward the back of the chassis, then lift it off
Removing the Metal Side Cover
Ä
CAUTION: The zx6000 and rx2600 systems depend on the access panels for proper cooling of internal
components. Operating the system with the side cover removed can cause the system to quickly overheat.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–7
Installing or Replacing Parts and Accessories
Replacing the Covers
5HSODFHWKHPHWDOFRYHU
Ä
CAUTION: Secure any wires or cables in your system so they do not get cut or interfere with the
replacement of the cover.
D $OLJQWKHIURQWHGJHRIWKHPHWDOFRYHUZLWKWKHDOLJQPHQWPDUNRQWKHRSWLFDOGULYHED\
Metal Cover Alignment Mark
E 3ODFHWKHPHWDOFRYHURQWKHFKDVVLVDQGVOLGHLWWRZDUGWKHIURQWRIWKHV\VWHPXQWLOWKH
EOXHUHOHDVHOHYHUVQDSVLQSODFH
Replacing the Metal Cover
2–8
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
5HSODFHWKHSODVWLFFRYHU
D $OLJQWKHFRYHU©VPRXQWLQJKROHVZLWKWKHPDWFKLQJWDEVRQWKHV\VWHPFKDVVLV
E &ORVHWKHFRYHUXQWLOLWVQDSVRQWRWKHV\VWHPFKDVVLV
Replacing the Plastic Cover
Removing the Front Bezel
<RXPXVWUHPRYHWKHIURQWEH]HOIURPWKHFKDVVLVWRXSJUDGHUHPRYHRUUHSODFHWKHSRZHU
VXSSOLHVRUWKHRSWLFDOGULYH
)LUPO\JUDVSWKHILQJHUJULSDWWKHWRSRIWKHEH]HODQGSXOOIRUZDUGXQWLOWKHEH]HOVQDSV
RSHQ
/LIWWKHEH]HORIIRIWKHFKDVVLV
Replacing the Front Bezel
,QVHUWWKHEH]HO©VODWFKHVLQWRWKHPDWFKLQJVORWVRQWKHV\VWHPFKDVVLV
&ORVHWKHEH]HODQGSXVKWRZDUGWKHIURQWRIWKHV\VWHPXQWLOLWVQDSVLQWRSODFH
2
1
Aligning the Front Bezel
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–9
Installing or Replacing Parts and Accessories
Rack-mount System
7RDFFHVVWKHLQWHUQDOFRPSRQHQWVRQDUDFNPRXQWHGV\VWHPSXOOWKHV\VWHPRXWRQWKHUDLO
JXLGHVDQGUHPRYHWKHPHWDOFRYHU
Removing the Metal Cover
7XUQRIIWKHV\VWHPDQGGLVFRQQHFWWKHSRZHUFDEOHDQGDOORWKHUFDEOHVIURPWKHEDFNRIWKH
V\VWHP
127(,I\RXDUHUHPRYLQJRQO\DKRWVZDSSDEOHV\VWHPIDQRUDKRWSOXJKDUGGULYH\RXFDQ
OHDYHWKHV\VWHPRQDQGWKHSRZHUFDEOHVFRQQHFWHG
5HOHDVHWKHUDFNODWFKHVE\URWDWLQJWKHPRXWZDUG
Releasing the Rack Latches
6OLGHWKHV\VWHPRXWRIWKHUDFNXQWLOWKHJXLGHUDLOUHOHDVHFOLSVDUHYLVLEOH
Guide-rail Release Clips
2–10
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
(QVXUHWKHWRSFRYHUORFNNH\VZLWFKLVLQWKHXQORFNHGSRVLWLRQWKHQURWDWHWKHEOXHUHOHDVH
OHYHUWRZDUGWKHEDFNRIWKHV\VWHPDQGVOLGHWKHSDQHOWRZDUGWKHEDFNRIWKHV\VWHP
/LIWWKHSDQHORIIWKHV\VWHPFKDVVLV
Removing the Metal Cover
Replacing the Cover
Ä
CAUTION: Secure any wires or cables in your system so they do not get cut or interfere with the
replacement of the cover.
$OLJQWKHIURQWHGJHRIWKHFRYHUZLWKWKHDOLJQPHQWPDUNRQWKHRSWLFDOGULYHED\
Metal Cover Alignment Mark
*UDVSWKHEOXHUHOHDVHOHYHUDQGVOLGHWKHFRYHUWRZDUGWKHIURQWRIWKHV\VWHPXQWLOWKHOHYHU
VQDSVLQWRSODFH
Replacing the Metal Cover
6OLGHWKHV\VWHPLQWRWKHUDFNHQFORVXUHDQGUHFRQQHFWWKHSRZHUFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–11
Installing or Replacing Parts and Accessories
Removing the Front Bezel
<RXPXVWUHPRYHWKHIURQWEH]HOIURPWKHFKDVVLVWRXSJUDGHUHPRYHRUUHSODFHWKHSRZHU
VXSSOLHVRUWKHRSWLFDOGULYH
3UHVVLQRQWKHUHWDLQLQJFOLSVORFDWHGRQWKHULJKWVLGHRIWKHIURQWSDQHO
Retaining Clip
5RWDWHWKHIURQWSDQHORXWZDUGDQGOLIWLWRIIWKHV\VWHPFKDVVLV
Replacing the Front Bezel
1. Insert the bezel latches into the matching slots on the system chassis.
2. Close the bezel and push toward the front of the system until it snaps into place.
1
2
Align the Front Bezel
2–12
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Removing/Replacing Hot-swap and Hot-plug Devices
7KHU[DQG][KDYHKDUGGLVNGULYHVWKDWDUHKRWSOXJJDEOHDQGSRZHUVXSSOLHVDQGIDQV
WKDWDUHKRWVZDSSDEOH7KLVVHFWLRQH[SODLQVKRZWRVZDSWKHIROORZLQJGHYLFHVZKLOHWKH
V\VWHPLVUXQQLQJ
■
6\VWHPIDQV
■
3RZHUVXSSOLHV
■
+DUGGULYHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–13
Installing or Replacing Parts and Accessories
System Fans
7KHUHDUHIRXUV\VWHPIDQVWRNHHSWKHV\VWHPFRROZKHQLWLVUXQQLQJ7KHV\VWHPIDQVDUH
KRWVZDSSDEOHDOORZLQJ\RXWRUHSODFHDIDQZKLOHWKHV\VWHPLVUXQQLQJ
Ä
CAUTION: When the system is running, the metal cover must be replaced within four minutes to prevent
components from overheating.
Removing a System Fan
5HPRYHWKHV\VWHPFRYHUV
5HPRYHWKHIDQ
D 7RUHPRYH
◆
IDQ$%RUIURPDUDFNPRXQWHGV\VWHPRU
◆
IDQIURPDWRZHUV\VWHPJUDVSWKHDSSURSULDWHIDQDQGOLIWLWRXWRIWKHIDQVRFNHW
1A
1B
2
3
Removing System Fans
2–14
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
E 7RUHPRYHIDQ$%RUIURPD][WRZHUV\VWHP
◆
8QSOXJWKHIDQSRZHUFRQQHFWRUWKHQ
◆
5HPRYHWKHIDQIURPWKHV\VWHP
Removing Fans 1A, 1B, or 2 from a Tower System
Replacing a System Fan
*UDVSWKHUHSODFHPHQWIDQPRGXOHDQGLQVHUWLWLQWRLWVIDQVRFNHW
Ä
CAUTION: Replace the metal cover within four minutes to prevent damage to the system components.
9HULI\WKDWWKHIDQKDVEHHQSURSHUO\LQVWDOOHGE\REVHUYLQJWKH/('VLJQDOVRQWKHIURQWRI
WKHV\VWHPIRUWKHDSSURSULDWHIDQLQIRUPDWLRQVHH&KDSWHU
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–15
Installing or Replacing Parts and Accessories
Power Supplies
7KHSRZHUVXSSOLHVLQWKH][DQG][V\VWHPVDUHKRWVZDSSDEOHWKDWLVLIRQHSRZHU
VXSSO\VWRSVZRUNLQJRUH[KLELWVYROWDJHSUREOHPVWKHUHPDLQLQJVXSSO\FDQVXSSRUWWKHV\VWHP
XQWLOWKHIDLOHGXQLWLVUHSODFHG2QV\VWHPVZLWKWZRSRZHUVXSSOLHVRQHSRZHUVXSSO\FDQEH
UHPRYHGDQGUHSODFHGZLWKRXWWXUQLQJRIIWKHV\VWHP
Ä
CAUTION: Before removing a power supply, make sure the second power supply is functioning
properly. The two green LEDs inside the supply must both be lit on the second supply before the
failed power supply can be safely removed.
Removing a Power Supply
5HPRYHWKHIURQWEH]HOIURPWKHV\VWHP
3UHVVWKHSRZHUVXSSO\UHWDLQLQJFOLSWRXQODWFKWKHSRZHUVXSSO\UHOHDVHOHYHU
Releasing the Power Supply Retaining Clip
'HSUHVVWKHSRZHUVXSSO\UHOHDVHOHYHUDQGVOLGHWKHSRZHUVXSSO\RXWRIWKHV\VWHP
Removing the Power Supply from the System
2–16
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing a Power Supply
5HPRYHWKHIURQWEH]HOIURPWKHV\VWHPDQGUHPRYHWKHGHIHFWLYHSRZHUVXSSO\LI\RXKDYH
QRWDOUHDG\GRQHVR
2SHQWKHSRZHUVXSSO\UHOHDVHOHYHUDQGVOLGHWKHSRZHUVXSSO\LQWRSODFH
Sliding the Power Supply into Place
3XVKLQRQWKHSRZHUVXSSO\UHOHDVHOHYHUWRORFNWKHUHWDLQLQJFOLSLQSODFH
5HSODFHWKHIURQWEH]HO
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–17
Installing or Replacing Parts and Accessories
Hard Drives
7KH][DQGU[V\VWHPVFDQVXSSRUWXSWRWKUHHKRWSOXJJDEOH/RZ9ROWDJH
'LIIHUHQWLDO/9'KDUGGLVNGULYHV7KHVHKDUGGLVNGULYHVDUHLQFKIRUPIDFWRU.DQG
.530GHYLFHVWKDWFRQQHFWWR8OWUD:LGH/9'/RZ9ROWDJH'LIIHUHQWLDO6&6,
LQWHUIDFHVRQWKHGLVNED\EDFNSODQH
7KHUHLVDVLJQLILFDQWGLIIHUHQFHEHWZHHQWKHWHUPVKRWSOXJJDEOHDQGKRWVZDSSDEOH
Ä
■
+RWVZDSSLQJKDSSHQVDWWKHGHYLFHOHYHOWKDWLVDKRWVZDSSDEOHGHYLFHPDQDJHV
LQVHUWLRQUHPRYDORQLWVRZQZLWKRXWDVVLVWDQFHIURPRSHUDWLQJV\VWHPFRPPDQGV
■
7KHKRWSOXJSURFHVVDOORZV\RXWRUHSODFHDGHIHFWLYHGLVNGULYHLQDKLJKDYDLODELOLW\
V\VWHPZKLOHLWLVUXQQLQJ
CAUTION: The disk drives in the zx6000 and rx2600 are not hot-swappable; they are merely
hot-pluggable. A manual software procedure must be done in order to safely remove or insert
disk drives while the system is running. To avoid damage to the hard drives:
■
■
See the documentation provided with the drive for additional details on inserting/removing a disk drive.
See your OS documentation for instructions on preparing the OS for inserting/removing a hard drive.
Removing a Hard Drive
,IWKHV\VWHPLVSRZHUHGRQDQGWKH26LVUXQQLQJSUHSDUHWKH26WRKDYHWKHGLVNGULYH
UHPRYHG6HH\RXU26GRFXPHQWDWLRQIRULQVWUXFWLRQVRQSHUSDULQJWKH26IRUUHPRYLQJDQG
LQVHUWLQJKDUGGULYHV
,I\RXKDYHORFNHG\RXUKDUGGULYHV\RXPXVWXQORFNWKHPEHIRUHUHPRYLQJRUUHSODFLQJD
GULYH
D 5HPRYHWKHFRYHUV
E 3UHVVGRZQRQWKH8QORFNOHYHUWRXQORFNWKHGULYH
Ä
CAUTION: If you try to remove a hard disk drive without unlocking it from the system, you will damage the
hard drive bay.
Unlocking the Hard Drives
2–18
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
6TXHH]HLQZDUGRQWKHFRORUHGUHOHDVHFOLSRQWKHKDUGGULYHUHOHDVHOHYHU
Releasing the Hard Drive Release Clip
3XOORXWZDUGRQWKHUHOHDVHOHYHUWRUHPRYHWKHGULYHIURPWKHV\VWHP
Removing the Hard Disk Drive
Replacing a Hard Drive
,IWKHV\VWHPLVSRZHUHGRQDQGWKH26LVUXQQLQJSUHSDUHWKH26WRKDYHWKHGLVNGULYH
UHPRYHG6HH\RXU26GRFXPHQWDWLRQIRULQVWUXFWLRQVRQSHUSDULQJWKH26IRUUHPRYLQJDQG
LQVHUWLQJKDUGGULYHV
,QVHUWWKHKDUGGLVNGULYHLQWRWKHGULYHED\IURPZKLFK\RXUHPRYHGWKHGULYHDQGSXVK
LQZDUGRQWKHUHOHDVHOHYHUXQWLOWKHGULYHQRORQJHUVOLGHVIRUZDUG<RXPXVWOHDYHWKH
UHOHDVHOHYHULQWKHRSHQSRVLWLRQDVVKRZQZKHQ\RXSXVKWKHGULYHLQWRWKHV\VWHP
3XVKLQRQWKHUHOHDVHOHYHUWRVHFXUHWKHGULYHLQWKHED\DQGWRHQVXUHWKDWWKHGULYH
FRQQHFWRULVVHDWHGSURSHUO\
5HVHWWKHV\VWHPWRWKH(),%RRW0DLQWHQDQFH0HQXWRUHVFDQWKHKDUGGULYHV
,IGHVLUHGORFNWKHKDUGGULYHLQSODFH5HSODFHWKHV\VWHPFRYHUVLIWKH\ZHUHUHPRYHGWR
XQORFNGULYHV
8VHWKH(),VKHOOmapFRPPDQGWRYHULI\WKDWWKHQHZGULYHKDVVXFFHVVIXOO\EHHQLQVWDOOHG
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–19
Installing or Replacing Parts and Accessories
Removing/Replacing Internal Components
7RXSJUDGHUHPRYHRUUHSODFHPRVWV\VWHPFRPSRQHQWV\RXPXVWILUVWUHPRYHWKHFRYHUVIURP
WKHV\VWHPFKDVVLV
Å
WARNING: Do not remove the system cover(s) without first turning the system off and unplugging the
power cord unless you are only replacing a hot-swappable system fan. Always replace the cover(s)
before turning the system on.
Airflow Guides
7KHV\VWHPKDVWKHIROORZLQJDLUIORZJXLGHV
■
7KHSURFHVVRUDLUIORZJXLGHSURYLGHVWKHSURSHUYROXPHRIDLUIORZIRUFRROLQJWKH
SURFHVVRUVDQGYROWDJHUHJXODWRUPRGXOHV950V
<RXPXVWUHPRYHWKHSURFHVVRUDLUIORZJXLGH
■
❏
LILWLVGDPDJHGWRWKHSRLQWWKDWDLUIORZDFURVVWKHSURFHVVRUVLVUHVWULFWHG
❏
WRDFFHVVWRFRPSRQHQWVXQGHUWKHDLUIORZJXLGH
7KHPHPRU\DLUIORZJXLGHHQVXUHVWKDWWKHSURSHUYROXPHRIDLUIORZVRYHUWKHPHPRU\
FDUGVWRFRROWKHP
<RXPXVWUHPRYHWKHPHPRU\DLUIORZJXLGH
❏
LILWLVGDPDJHGWRWKHSRLQWWKDWDLUIORZDFURVVWKHPHPRU\FDUGVLVUHVWULFWHG
❏
WRDFFHVVPHPRU\PRGXOHVDQGVORWV
127($LUIORZVWKURXJKWKHV\VWHPIURPIURQWWREDFN
1
3
2
System Airflow Guides
2–20
1
Memory Airflow Guide
2
Processor Airflow Guide
3
Processor Airflow Guide Front Half
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Removing the Memory Airflow Guide
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUFDEOHVDQGUHPRYHWKHFRYHUV
*UDVSWKHPHPRU\DLUIORZJXLGHDQGOLIWLWRXWRIWKHV\VWHP
Removing the Memory Airflow Guide
Replacing the Memory Airflow Guide
$OLJQWKHJXLGHVRQERWKVLGHVRIWKHDLUIORZJXLGHZLWKWKHVORWVRQWKHFKDVVLV
Aligning the Memory Airflow Guide
,QVHUWWKHPHPRU\DLUIORZJXLGHLQWKHVORWV
Replacing the Memory Airflow Guide
5HSODFHWKHFRYHUVDQGUHFRQQHFWDOORIWKHSRZHUFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–21
Installing or Replacing Parts and Accessories
Removing Processor Airflow Guide
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
5HPRYHWKH,'(DQGSRZHUFDEOHVIURPWKHSURFHVVRUDLUIORZJXLGHFDEOHFOLSV
5HPRYHWKHPDLQSRUWLRQRIWKHDLUIORZJXLGH
D +ROGWKHJXLGHXVLQJWKHRSHQLQJRQWRSRIWKHJXLGH
E $WWKHVDPHWLPHJUDVSWKHEDFNHQGRIWKHDLUIORZJXLGHDQGOLIWWKHJXLGHRXWRIWKH
V\VWHP
Removing the Main Portion of the Processor Airflow Guide
5HPRYHWKHIURQWSRUWLRQRIWKHDLUIORZJXLGH
D 5HPRYHV\VWHPIDQV$DQG%SDJH
E 5RWDWHWKHFOLSFORFNZLVHWRUHOHDVHWKHODWFK
Airflow Guide Release Latch and Post
'LVFRQQHFWWKHSRZHUFDEOHFRQQHFWHGWRWKHJXLGHIURPWKHV\VWHPERDUG
Power Connector for Front Portion of Airflow Guide
2–22
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
/LIWWKHIURQWSRUWLRQRIWKHDLUIORZJXLGHRXWRIWKHV\VWHP
Removing the Front Portion of the Airflow Guide
Replacing the Processor Airflow Guide
5HSODFHWKHIURQWSRUWLRQRIWKHDLUIORZJXLGH
D $OLJQWKHUHOHDVHODWFKRIWKHIURQWKDOIRIWKHDLUIORZJXLGHRYHUWKHUHOHDVHODWFKSRVW
DQGVQDSLWLQSODFH
E &RQQHFWSRZHUFRQQHFWRURQWKHIURQWSRUWLRQRIWKHJXLGHWRWKHFRQQHFWRURQWKH
V\VWHPERDUG
F 5HSODFHV\VWHPIDQV$DQG%SDJH
5HSODFHWKHPDLQSRUWLRQRIWKHDLUIORZJXLGH
D +ROGWKHRSHQLQJRQWRSRIWKHSURFHVVRUDLUIORZJXLGH
E $WWKHVDPHWLPHJUDVSWKHEDFNHQGRIWKHDLUIORZJXLGHDQGLQVHUWWKHDLUIORZJXLGH
LQWRWKHV\VWHP
F &RQQHFWWKHSRZHUFDEOHDQGSODFHWKHSRZHUDQG,'(FDEOHVLQWKHFDEOHFOLSV
G ,QVHUWWKHWZRDLUIORZJXLGHUHWDLQLQJWDEVLQWRWKHWZRVORWVRQWKHIURQWKDOIRIWKH
DLUIORZJXLGH
3
2
1
4
Replacing the Processor Airflow Guide
1
Cable clips
2
Main portion of airflow guide
3
Retainer clips
4
Front portion of airflow guide
5HSODFHWKHV\VWHPFRYHUV5HFRQQHFWFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–23
Installing or Replacing Parts and Accessories
Memory
<RXUV\VWHPKDVPHPRU\VORWVIRULQVWDOOLQJ''56'5$0PHPRU\PRGXOHV0RGXOHVFDQ
EH0%0%*%RU*%7KHV\VWHPVXSSRUWVFRPELQDWLRQVIURP0%][
RU*%U[XSWR*%)RU+3DSSURYHGPHPRU\PRGXOHVVHH$SSHQGL[&
127(][ZRUNVWDWLRQVUXQQLQJ:LQGRZV;3%LW(GLWLRQ9HUVLRQRQO\VXSSRUWXS
WR*%RI5$0
Removing Memory Modules
7XUQRIIWKHV\VWHPGLVFRQQHFWSRZHU/$1DQGWHOHFRPPXQLFDWLRQVFDEOHVDQGUHPRYHWKH
FRYHUV
Ä
CAUTION: To ensure that memory modules are not damaged during removal or installation, turn off the
system and unplug the power cord from the AC power outlet. Wait until the LED on the back of the power
supply turns off before removing memory.
3UHVVGRZQRQWKHPHPRU\PRGXOHUHWDLQHUFOLSVDQGOLIWWKHPRGXOHRXWRILWVPHPRU\VORW
Memory Module Retainer Clips
,IWKHUHPRYHGPHPRU\LVIXQFWLRQDOVWRUHLWLQDVWDWLFIUHHFRQWDLQHUIRUIXWXUHXVH
2–24
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing Memory Modules
0HPRU\PRGXOHVPXVWEHORDGHGLQWKHFRUUHFWRUGHU
■
,QWKH][ZRUNVWDWLRQ',00VPXVWEHLQVWDOOHGDVRUGHUHGSDLUVRIHTXDOVL]H)RU
H[DPSOHWKH',00LQVORW$PXVWPDWFK%$PXVWPDWFK%DQGVRIRUWK
■
,QWKH,QWHJULW\U[VHUYHU',00VPXVWEHLQVWDOOHGLQPDWFKHGTXDGV)RXULGHQWLFDO
',00VPXVWEHLQVWDOOHGRQHSDLUSHUPHPRU\FHOODVOLVWHGEHORZ
❏
$%DQG$%PXVWPDWFK
❏
$%DQG$%PXVWPDWFK
❏
$%DQG$%PXVWPDWFK
7KLVORDGLQJRUGHUPXVWEHXVHGWRHQDEOHFKLSVSDUHIXQFWLRQDOLW\DYDLODEOHRQO\RQU[
V\VWHPV)RUPRUHLQIRUPDWLRQVHH$SSHQGL[%
127(',00VPDWFKLIWKH\KDYHWKHVDPH+3SDUWQXPEHU
■
0RGXOHVL]HVFDQEHPL[HGDVORQJDV',00VLQHDFKSDLU][RUTXDGU[
PDWFK)RUH[DPSOH
❏
2Q][ZRUNVWDWLRQVLWLVDFFHSWDEOHWRORDGDSDLURI0%',00VLQVORWV$
DQG%DQGDSDLURI*%',00VLQVORWV$DQG%
❏
2Q,QWHJULW\U[VHUYHUVLWLVDFFHSWDEOHWRORDGDTXDGRI0%',00VLQVORWV
$%$DQG%DQGDTXDGRI*%',00VLQVORWV$%$DQG%
Front
Loading Order
Memory Cell 0
Memory Cell 1
Loading Order
1st
DIMM 0B
DIMM 1B
2nd
5th
DIMM 4B
DIMM 5B
6th
3rd
DIMM 2B
DIMM 3B
4th
1st
DIMM 0A
DIMM 1A
2nd
5th
DIMM 4A
DIMM 5A
6th
3rd
DIMM 2A
DIMM 3A
4th
Back
Memory Loading Order
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–25
Installing or Replacing Parts and Accessories
7RLQVWDOORUUHSODFHDPHPRU\PRGXOH
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOFDEOHVDQGUHPRYHWKHV\VWHPFRYHUV
Ä
CAUTION: To ensure that memory modules are not damaged during removal or installation, power off
the system and unplug the power cord from the AC power outlet. Wait until the STBY PWR LED on the
System Board turns off before removing or installing memory.
+ROGLQJWKHPHPRU\PRGXOHE\LWVOHIWDQGULJKWHGJHVLQVHUWWKHPRGXOHLQWRWKHVORW
7KHPHPRU\PRGXOHVDUHNH\HGDQGFDQRQO\EHLQVHUWHGLQRQHGLUHFWLRQ:KHQWKHPRGXOH
LVFRUUHFWO\VHDWHGWKHUHWDLQHUFOLSVUHWXUQWRWKHLUIXOO\XSULJKWSRVLWLRQ6QDSWKHFOLSV
ILUPO\LQWRSODFHWRHQVXUHWKDWWKH',00VDUHVHDWHGSURSHUO\
5HSODFHWKHV\VWHPFRYHUVUHFRQQHFWDOOFDEOHVDQGWXUQRQWKHV\VWHP
9HULI\FRUUHFWPHPRU\FRQILJXUDWLRQ(LWKHU
2–26
❏
5XQWKHinfo mem FRPPDQGDWWKH(),VKHOOSURPSWSDJH
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUFKHFNWKHFRQILJXUDWLRQXVLQJWKH(),
System Configuration menuSDJH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Accessory and Graphics Cards
7KH][KDVWKHIROORZLQJDFFHVVRU\FDUGVORWV
■
7KUHHELW0+]3&,;FDUGVORWV
■
2QH$*33UR×,9VORW
7KHU[KDVWKHIROORZLQJDFFHVVRU\FDUGVORWV
■
)RXUELW0+]3&,;FDUGVORWV
$FFHVVRU\FDUGVDUHLQVWDOOHGLQDUHPRYDEOH3&,$*3FDJH7KLVVHFWLRQH[SODLQVKRZWRDFFHVV
WKH3&,$*3FDJHDVZHOODVKRZWRUHPRYHDQGLQVWDOODFFHVVRU\FDUGV
Removing an Accessory or Graphics Card
7XUQRIIV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHPFRYHUV
/LIWXSRQWKH3&,$*3FDJHUHOHDVHOHYHUDQGWKHEDFNHGJHRIWKH3&,$*3FDJHDQGOLIW
WKH3&,$*3FDJHRXWRIWKHV\VWHP
Removing the PCI/AGP Cage
127(,I\RXDUHUHPRYLQJDQ$*3FDUG\RXPD\DOVRQHHGWRUHPRYHWKH$*3VKLSPHQW
UHWDLQHU7XUQWKHVKLSPHQWUHWDLQHUFRXQWHUFORFNZLVHDQGOLIWLWRXWRIWKHV\VWHP
Plastic AGP Card Shipment Retainer
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–27
Installing or Replacing Parts and Accessories
*UDVSWKH3&,$*3FDJHFRYHUDQGVOLGHLWDZD\IURPWKHEXONKHDGHQGRIWKHFDJHWKHQOLIW
WKHFRYHURII
Removing the PCI/AGP Cage Cover
8QVFUHZWKHEXONKHDGVFUHZWKDWKROGVWKHDFFHVVRU\FDUGLQSODFH
127(,I\RXDUHUHPRYLQJDQDXGLRFDUGXQSOXJWKHDXGLRFDEOHIURPWKHFDUG
Removing the Bulkhead Screw
*UDVSWKHEXONKHDGHQGRIWKHFDUGDQGWKHRSSRVLWHHGJHDQGOLIWWKHFDUGRXWRIWKHVORW,I
\RXDUHQRWLQVWDOOLQJDQHZFDUGLQWKHVDPHVORWLQVWDOODEODQNLQWKHVORW
Removing the Accessory Card
2–28
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing an Accessory or Graphics Card
5HPRYHWKH3&,$*3FDJHSDJH
5HPRYHDQ\EXONKHDGEODQNLISUHVHQWIURPWKHVORWWREHXVHG
,QVHUWWKHFDUG
D *UDVSWKHEXONKHDGHQGRIWKHFDUGDQGLWVRSSRVLWHHGJHDQGLQVHUWWKHFDUGLQWRWKHVORW
,I\RXDUHUHSODFLQJDFDUGSXWWKHQHZFDUGLQWRWKHVDPHVORWIURPZKLFK\RXUHPRYHG
WKHROGFDUG
E 6HFXUHWKHFDUGE\DWWDFKLQJWKHVFUHZWKDWZDVXVHGWRKROGWKHEODQNLQSODFH
$WWDFKWKHFRYHUWRWKHFDJH
D 6OLGHWKHUHWDLQLQJWDEVRQWKHIDQHQGRIWKHFRYHULQWRWKHUHWDLQLQJVORWVDQGSUHVVWKH
FRYHUGRZQRQWKHDFFHVVRU\ERDUGV
E 6OLGHWKHWDEDWWKHEXONKHDGHQGRIFDJHLQWRWKHVORWRQWKHFRYHU
1
2
Replacing the PCI/AGP Cage Board Cover
,I\RXDUHUHSODFLQJDQDXGLRFDUGDWWDFKWKHDXGLRFDEOHWRWKHFDUGDQGWRWKHFRQQHFWRU
RQWKH3&,$*3EDFNSODQH
1
2
Connecting the Audio Cable
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–29
Installing or Replacing Parts and Accessories
3ODFHWKH3&,$*3FDJHEDFNLQWKHV\VWHPDQGVHFXUHLW
D $OLJQWKH3&,$*3FDJHLQWKHV\VWHPWKHQGHSUHVVWKHUHOHDVHOHYHUWRORFNWKHFDJHLQ
SODFH
E ,I\RXKDYHDQ$*3FDUGLQVWDOOHGVHFXUHWKHSODVWLFVKLSPHQWUHWDLQHU
5HSODFHWKHFRYHUVUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHVDQGWXUQRQWKHV\VWHP
9HULI\WKDWQHZFDUGVKDYHEHHQFRUUHFWO\LQVWDOOHG
❏
5XQWKHinfo io FRPPDQGDWWKH(),VKHOOSURPSWSDJHRU
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUFKHFNWKHFRQILJXUDWLRQXVLQJWKH(),
System Configuration menuSDJH
127((QVXUHWKDWWKHDXGLRFDEOHLVSURSHUO\LQVWDOOHGE\FRQQHFWLQJKHDGSKRQHVWRWKHDXGLR
287MDFNRQWKHDXGLRFDUGDQGSOD\LQJDXGLRPHGLDLQWKHRSWLFDOGHYLFH
2–30
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
PCI/AGP Backplane
Removing the PCI/AGP Backplane
7KHEDFNSODQHIRUWKH][LQFOXGHVRQH$*3FDUGVORWDQGWKUHH3&,FDUGVORWV7KHU[
V\VWHPEDFNSODQHLVFDOOHGWKH3&,$*3EDFNSODQH7KHUHPRYDOSURFHVVLVWKHVDPHIRUERWK
5HPRYHDOODFFHVVRU\DQGJUDSKLFVFDUGV
8QVFUHZWKHEDFNSODQHPRXQWLQJVFUHZVDQGVOLGHWKHEDFNSODQHERDUGWRZDUGWKHEXONKHDG
HQGRIWKH3&,$*3FDJH7KLVXQORFNVWKHEDFNSODQHIURPLWVVWDQGRIIV
/LIWWKHEDFNSODQHRYHUWKHWRSRIWKHVWDQGRIIVDQGVOLGHLWRXWRIWKHFDJH
Ä
CAUTION: Be careful not to damage the intrusion switch.
Removing the PCI/AGP backplane (rx2600 shown)
Replacing the PCI/AGP Backplane
3ODFHWKHEDFNSODQHLQWKHFDJHE\DOLJQLQJWKHFDJHVWDQGRIIVZLWKWKHKROHVRQWKH
EDFNSODQHDQGVOLGHLWLQWRSODFH
6HFXUHWKH3&,$*3EDFNSODQHE\VFUHZLQJLQLWVPRXQWLQJVFUHZV
Replacing the PCI/AGP backplane (rx2600 shown)
5HSODFHDQ\DFFHVVRU\DQGJUDSKLFVFDUGV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–31
Installing or Replacing Parts and Accessories
Optical Drives
Removing an Optical Drive
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
'LVFRQQHFWWKH,'(FDEOHIURPWKHEDFNRIWKHRSWLFDOGULYH3XOOEDFNRQWKHUHWDLQLQJFOLSV
RQWKHFRQQHFWRUFDEOHWRUHOHDVHWKHFDEOH
Disconnecting the Optical Drive IDE Cable
3UHVVWKHVPDOOUHWDLQLQJFOLSVRQERWKVLGHVRIWKHRSWLFDOGULYHLQZDUGWRUHOHDVHWKHP
Releasing the Optical Drive Retaining Clips
6OLGHWKHRSWLFDOGULYHRXWRIWKHRSWLFDOGULYHED\
Removing the Optical Drive
2–32
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing an Optical Drive
6OLGHWKHRSWLFDOGULYHLQWRWKHGULYHED\XQWLOLWVWRSVVOLGLQJDQGWKHUHWDLQLQJFOLSVRQERWK
VLGHVRIWKHRSWLFDOGULYHVQDSLQWRSODFH
*UDVSERWKVLGHVRIWKHGULYHZLWKRXWSUHVVLQJLQRQWKHUHWDLQLQJFOLSVDQGSXOORXWZDUG,I
\RXFDQSXOORXWZDUGRQWKHRSWLFDOGULYHZLWKRXWLWVOLGLQJRXWRILWVED\WKHRSWLFDOGULYHLV
VHFXUHO\LQSODFH
Replacing the Optical Drive
&RQQHFWWKH,'(FDEOHRQWKHEDFNRIWKHRSWLFDOGULYH
5HSODFHWKHV\VWHPFRYHUVUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHVDQGWXUQRQWKH
V\VWHP
9HULI\WKDWWKHRSWLFDOGULYHKDVEHHQSURSHUO\LQVWDOOHG
❏
5XQWKHinfo io FRPPDQGDWWKH(),VKHOOSURPSWSDJHRU
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUFKHFNWKHFRQILJXUDWLRQXVLQJWKH(),
System Configuration menuSDJH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–33
Installing or Replacing Parts and Accessories
Management Processor Card
7KHRSWLRQDO0DQDJHPHQW3URFHVVRU03FDUGLQFOXGHVWKHVHSRUWV
■
%70DQDJHPHQW/$1SRUW
■
SLQ9*$SRUW
■
SLQVHULDOSRUW
Removing the MP Card
5HFRUGWKHQHWZRUNVHWWLQJVIURP\RXU03FDUGEHIRUHEHJLQQLQJWKLVWDVN6HH
¦0DQDJHPHQW3URFHVVRU03§RQSDJH
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHFRYHUV
8QVFUHZWKHWZRSRZHUFRQQHFWRUPRXQWLQJVFUHZVDQGUHPRYHWKHSRZHUFRQQHFWRU
SODWHIURPWKHEDFNRIWKHV\VWHP
1
2
Removing the Power Connectors
8QVFUHZWKHWZRPRXQWLQJVFUHZVWKDWFRQQHFWWKH03FDUGWRWKHLQWHUQDOFKDVVLVSRVW
DQGWKHWZRH[WHUQDOPRXQWLQJVFUHZVWKDWDUHORFDWHGRQERWKVLGHVRIWKHSLQVHULDO
FRQQHFWRU.
1
2
Unscrew the MP Card Mounting Screws
2–34
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
'LVFRQQHFWWKH03FDUGFRQQHFWRU
Disconnecting the MP Card Connector
5HPRYHWKH03FDUGIURPWKHV\VWHPE\JUDVSLQJLWE\LWVHGJHV
Removing the Card
5HSODFHWKH03FDUGEODQNLIDYDLODEOHRQWKHFKDVVLV7KLVEODQNLVXVHGWRILOOWKHKROHVOHIW
E\WKH/$1SLQ9*$DQGSLQVHULDOFRQQHFWRUV
D ,QVHUWWKHEODQNUHWDLQLQJWDELQWRWKHVORWRQWKHFKDVVLV
Aligning the MP Card Blank
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–35
Installing or Replacing Parts and Accessories
E 3XVKWKH03FDUGEODQNDJDLQVWWKHLQVLGHRIWKHFKDVVLVDQGVFUHZLQWKHEODQN©V
PRXQWLQJVFUHZRQWKHH[WHUQDOFRQQHFWRUVLGHRIWKHV\VWHP©VFKDVVLV
Securing the MP Card Blank
5HSODFHWKHFRYHUVDQGUHFRQQHFWWKHSRZHUDQGH[WHUQDOFDEOHV
Replacing/Installing the MP Card
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
,I\RXDUHLQVWDOOLQJDQHZFDUGUHPRYHWKH03FDUGEODQN
D 8QVFUHZWKHPRXQWLQJVFUHZIRUWKH03FDUGEODQNORFDWHGRQWKHH[WHUQDOFRQQHFWRU
VLGHRIWKHV\VWHPFKDVVLV
E 5HPRYHWKHEODQNUHWDLQLQJWDERXWRILWVVORWRQWKHV\VWHPFKDVVLVDQGUHPRYHWKHEODQN
IURPWKHV\VWHP
,QVHUWWKH03FDUGLQWKHV\VWHP
D *UDVSLWVHGJHVDQGSODFHLWRQWKHWZR03FDUGSRVWV
E 3XVKWKH/$1SLQ9*$DQGSLQVHULDOFRQQHFWRUVWKURXJKWKHLURSHQLQJVRQWKH
EDFNRIWKHV\VWHP
&RQQHFWWKH03FDUG
D &RQQHFWWKH03FDUGFDEOHWRLWVFRQQHFWRURQWKHV\VWHPERDUG
E 6FUHZLQWKHWZRPRXQWLQJVFUHZVWKDWFRQQHFWWKH03FDUGWRWKHLQWHUQDOFKDVVLVSRVW
F 6FUHZLQWKHWZRH[WHUQDOPRXQWLQJVFUHZVWKDWDUHORFDWHGRQERWKVLGHVRIWKHSLQ
VHULDOFRQQHFWRU
G 5HSODFHWKHWZRSRZHUFRQQHFWRUV
5HSODFHWKHV\VWHPFRYHUVDQGUHFRQQHFWWKHSRZHUDQGH[WHUQDOFDEOHV
2–36
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Led Status Panel
7KH/('VWDWXVSDQHOFDUGFRQWDLQVWKHV\VWHP/('VDQGWKHHEX]]HU
Ä
CAUTION: Some system settings are saved to the LED status panel. If you are replacing both the LED
status panel and the system board, they must be replaced one at a time to avoid loss of system settings.
First replace one component, then turn on the system and boot to the EFI prompt. After confirming that the
first component has been replaced successfully, shut down the system and replace the second
component.
Removing the LED Status Panel
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUFDEOHVDQGUHPRYHWKHV\VWHPFRYHUV
'LVFRQQHFWWKH/('VWDWXVSDQHO©VFRQWUROOHUFDEOH
Disconnect the LED Status Card Controller Cable
8QVFUHZWKHWZR/('VWDWXVSDQHOPRXQWLQJVFUHZVDQGUHPRYHWKHSDQHO
Remove the LED Status Card
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–37
Installing or Replacing Parts and Accessories
Replacing the LED Status Panel
5HSODFHWKH/('VWDWXVSDQHOLQWKHV\VWHPDQGVFUHZLQWKHWZR/('VWDWXVSDQHOPRXQWLQJ
VFUHZV
&RQQHFWWKH/('VWDWXVSDQHOFRQWUROOHUFDEOH
5HSODFHWKHV\VWHPFRYHUVDQGUHFRQQHFWDOOSRZHUFDEOHV7XUQRQWKHV\VWHPDQGYHULI\
WKDWWKHV\VWHPDQGSRZHU/('VOLJKWXS
&RS\DYDOLG88,'WRWKHQHZVWDWXVSDQHO7RGRWKLVGXULQJERRWXSSUHVVYDWWKLVSURPSW
EFI version 1.10 [14.57]
Build flags: EFI64 Running on Intel(R) Itanium Processor
EFI 1.10 IA-64 FOUNDATION XPEAK 1.22 [Tue May 14 16:37:12 2002] - HP
Secondary UUID is undefined
Do you want to copy the valid UUID to the new board?
(y/[n])
$PHVVDJHVLPLODUWRWKLVDSSHDUV
EFI version 1.10 [14.57]
Build flags: EFI64 Running on Intel(R) Itanium Processor
EFI 1.10 IA-64 FOUNDATION XPEAK 1.22 [Tue May 14 16:37:12 2002] - HP
Secondary UUID is undefined
Do you want to copy the valid UUID to the new board?
(y/[n]) 2 0 0x0002F2 0x0000000000000000 UUID was set to valid value
7KLVLQGLFDWHV\RXKDYHVXFFHVVIXOO\DVVLJQHGWKHV\VWHPERDUG88,'WRWKHVWDWXVSDQHO
127(,IUHVHWWLQJWKH88,'GRHVQRWZRUNVXFFHVVIXOO\FRQWDFW\RXU+3VXSSRUW
UHSUHVHQWDWLYH
2–38
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Processor
,IWKHUHDUHWZRSURFHVVRUVRQWKHV\VWHPERDUGWKHSURFHGXUHIRUUHPRYLQJWKHPLVWKHVDPH
Ä
CAUTION: You must disconnect all power and follow the correct sequence of steps provided in this
section to avoid serious damage to the system.
Removing a Processor
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
5HPRYHWKHSURFHVVRUDLUIORZJXLGHDQGFDEOHV
8QVFUHZWKHSURFHVVRUSRZHUSRGPRXQWLQJVFUHZVDQGGLVFRQQHFWWKHPRGXOHIURPLWV
SURFHVVRUE\VOLGLQJLWWRZDUGWKHEDFNRIWKHV\VWHPFKDVVLV
1
2
Disconnect the Processor Power Pod
5HPRYHWKHSURFHVVRUSRZHUSRGIURPWKHV\VWHP
Remove the Processor Power Pod
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–39
Installing or Replacing Parts and Accessories
'LVFRQQHFWWKHSRZHUFDEOHIRUWKHSURFHVVRUWXUERIDQ
Disconnect the Power Cable for the Processor Turbo Fan
8QVFUHZWKHIRXUKHDWVLQNFDSWLYHVFUHZVXVLQJWKHVSHFLDOSURFHVVRUWRRO+33DUW1XPEHU
$
❏
6OLGHWKHVHTXHQFLQJUHWDLQHUSODWHWRZDUGWKHEDFNRIWKHV\VWHPWRRSHQWKHKROHLQWKH
HGJHRIWKHWXUERIDQKHDWVLQNIRULQVHUWLRQRIWKHVSHFLDOSURFHVVRUWRROLQWRWKH
SURFHVVRUORFNLQJPHFKDQLVP
Unscrew the Turbo Fan Heatsink Captive Screws
2–40
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
8QORFNWKHSURFHVVRUORFNLQJPHFKDQLVPXVLQJWKHVSHFLDOSURFHVVRUWRROVKLSSHGZLWK\RXU
UHSODFHPHQWSURFHVVRUDVVHPEO\
,QVHUWWKHWRROLQWRWKHKROHWKDWUXQVGRZQWKURXJKWKHHGJHRIWKHWXUERIDQKHDWVLQNDQG
URWDWHWKHVSHFLDOSURFHVVRUWRROGHJUHHVFRXQWHUFORFNZLVH
Unlocking the Processor Locking Mechanism with the Special Processor Tool
1
,QVHUWVSHFLDOSURFHVVRUWRROKHUH
2
7KHVSHFLDOSURFHVVRUWRROURWDWHVWKLVORFNXQGHUQHDWKWKHKHDWVLQN
3
8QORFNHG
4
/RFNHG
5HPRYHWKHWXUERIDQKHDWVLQNDQGSURFHVVRUIURPWKHV\VWHP
Removing the Turbo Fan Heatsink and the Processor
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–41
Installing or Replacing Parts and Accessories
Replacing or Installing a Processor
<RXPXVWKDYHDSURFHVVRULQVRFNHW&38EHIRUHLQVWDOOLQJRQHLQVRFNHW&38
,I\RXDUHLQVWDOOLQJDVHFRQGSURFHVVRUWXUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQG
H[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHPFRYHUV
,I\RXDUHUHSODFLQJDSURFHVVRUUHPRYHWKHROGSURFHVVRU
(QVXUHWKDWWKHSURFHVVRUORFNLQJPHFKDQLVPLVURWDWHGLQWRWKHXQORFNHGSRVLWLRQ
1
2
1
2
Processor Locking Mechanism
1
8QORFNHG
2
/RFNHG
&KHFNWRHQVXUHWKDWQRSURFHVVRUSLQLVEHQW
2–42
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
8VHWKHIRXUORFDWRUSRVWVRQWKHKHDWVLQNDQGWKHWXUERIDQSRZHUFDEOHWRSURSHUO\DOLJQWKH
IDQDQGSURFHVVRUDVVHPEO\RQWKHV\VWHPERDUG7KHIRXUORFDWRUSRVWVZLOOILWLQORFDWRU
KROHVRQWKHV\VWHPERDUGSURFHVVRUPRXQW7KHWXUERIDQSRZHUFDEOHPXVWEHSRVLWLRQHGVR
WKDWLWLVORFDWHGRQWKHVLGHRIWKHKHDWVLQNWKDWIDFHVWKHIURQWRIWKHV\VWHP
1
2
Aligning the Turbo Fan and Processor Assembly
1
Locator Posts
2
Locator Holes
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–43
Installing or Replacing Parts and Accessories
8VHWKHVSHFLDOSURFHVVRUWRROVKLSSHGZLWK\RXUUHSODFHPHQWSURFHVVRUDVVHPEO\WRORFNWKH
SURFHVVRULQSODFHRQWKHV\VWHPERDUG7RGRWKLVLQVHUWWKHVSHFLDOSURFHVVRUWRROLQWRWKH
KROHWKDWUXQVGRZQWKHVLGHRIWKHKHDWVLQNDQGURWDWHLWFORFNZLVHGHJUHHV
Locking the Processor in Place
6OLGHWKHVHTXHQFLQJUHWDLQHUSODWHWRZDUGWKHIURQWRIWKHV\VWHP
Sliding Sequencer Retainer
2–44
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
6FUHZLQWKHIRXUKHDWVLQNFDSWLYHVFUHZV
Screw in the Heatsink and Processor Screws
&RQQHFWWKHSRZHUFDEOHIRUWKHSURFHVVRUWXUERIDQWRLWVFRQQHFWRURQWKHV\VWHPERDUG
6OLGHWKHSURFHVVRUSRZHUSRGRQWKHV\VWHPERDUGPHWDOPRXQWLQJEUDFNHWVRWKDWWKH
SURFHVVRUSRZHUSRGFRQQHFWVWRWKHSURFHVVRU$OLJQWKHWZRPRXQWLQJVFUHZKROHVRQWKH
SURFHVVRUSRZHUSRGZLWKWKHKROHVRQWKHV\VWHPERDUGPHWDOPRXQWLQJEUDFNHW6FUHZLQ
WKHSURFHVVRUSRZHUSRGPRXQWLQJVFUHZV
5HSODFHWKHSURFHVVRUDLUIORZJXLGHFRQQHFWWKHSRZHUFDEOHDQGWXUQRQWKHV\VWHP
9HULI\WKDWWKHSURFHVVRUZRUNV
❏
5XQWKHinfo cpu FRPPDQGDWWKH(),VKHOOSURPSWSDJHRU
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUFKHFNWKHFRQILJXUDWLRQXVLQJWKH(),
System Configuration menuSDJH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–45
Installing or Replacing Parts and Accessories
System Board
Ä
CAUTION: Some system settings are saved to the LED status panel. If you are replacing both the LED
status panel and the system board, they must be replaced one at a time to avoid loss of system settings.
First replace one component, then turn on the system and boot to the EFI prompt. After confirming that the
first component has been replaced successfully, shut down the system and replace the second
component.
Removing the System Board
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
5HPRYHWKHVHFRPSRQHQWVIURPWKHV\VWHPERDUG
❏
0HPRU\
❏
6\VWHPIDQV
❏
3&,$*3FDUGFDJH
❏
3URFHVVRUDLUIORZJXLGHDQGSURFHVVRUV
❏
03FDUGLILQVWDOOHG
,IWKHV\VWHPGRHVQRWKDYHDQ03FDUGLQVWDOOHGUHPRYHWKHSRZHUFRQQHFWRUSODWH
D 8QVFUHZWKHWZRSRZHUFRQQHFWRUPRXQWLQJVFUHZVRQWKHEDFNRIWKHV\VWHP(1)DQG
UHDFKLQVLGHWKHV\VWHPWRUHPRYHWKHSRZHUFRQQHFWRUVIURPWKHVRFNHW7KHSRZHU
FRQQHFWRUVZLOOVWLOOEHFRQQHFWHGWRWKHLUFDEOHV
1
2
Removing the Power Connector Plate
8QVFUHZWKHVL[EDFNSODQHV\VWHPERDUGPRXQWLQJVFUHZVWKDWFRQQHFWWKHV\VWHPERDUGWR
WKHUHDURIWKHV\VWHPFKDVVLV
2–46
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Six System Board Mounting Screws
'LVFRQQHFWDOOFDEOHVWKDWDUHFRQQHFWHGWRWKHV\VWHPERDUG7RKHOSZLWKUHDVVHPEO\PDNH
QRWHRIZKLFKFDEOHVZHUHFRQQHFWHGWRZKLFKFRQQHFWRU
127(7RDFFHVVWKHWKUHHSRZHUFDEOHVQHDUWKH3&,$*3FDJH\RXPXVWOLIWXSWKHFRQQHFWRU
EULGJHIRUWKH3&,$*3FDJHIDQ
8QVFUHZWKHV\VWHPERDUGPRXQWLQJVFUHZ$VFUHZV\PEROLVDGMDFHQWWRWKHPRXQWLQJ
VFUHZ
6\VWHP©V)URQW
Unscrew the System Board Mounting Screw
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–47
Installing or Replacing Parts and Accessories
5HPRYHWKHV\VWHPERDUG
D *UDVSWKHPHPRU\FRQWUROOHUFKLSKHDWVLQNDQGWKHSURFHVVRUKHDWVLQNDQGVOLGHWKH
V\VWHPERDUGWRZDUGWKHIURQWRIWKHV\VWHP7KLVUHOHDVHVWKHV\VWHPERDUGIURPLWV
FKDVVLVVWDQGRIIV
E /LIWXSWKHSURFHVVRUVLGHRIWKHV\VWHPERDUGDQGVOLGHLWIUHHRIWKH3&,$*3FDJHED\
Remove the System Board from the System
Replacing the System Board
5HPRYHWKHROGV\VWHPERDUG
*UDVSWKHQHZV\VWHPERDUGE\LWVHGJHVDQGFDUHIXOO\DOLJQLWLQWKHV\VWHP
❏
$QJOHWKHERDUGWRDOORZWKH3&,FRQQHFWRUWRVOLGHLQWRWKH3&,$*3FDJHED\DUHD
❏
$OLJQWKHV\VWHPERDUGNH\KROHVZLWKWKHLUFRUUHVSRQGLQJVWDQGRIIVRQWKHFKDVVLV
❏
6OLGHWKH3&,FRQQHFWRUSRVWVRQWKHV\VWHPERDUGLQWRWKHLUVORWVRQWKHV\VWHP
FKDVVLV
1
2
Align the System Board in the System
2–48
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
6OLGHWKHV\VWHPERDUGEDFNWRZDUGWKHUHDURIWKHV\VWHPWRVHFXUHWKHV\VWHPERDUGRQLWV
VWDQGRIIV
Secure the System Board on its Standoffs
6FUHZLQWKHV\VWHPERDUGPRXQWLQJVFUHZ
&RQQHFWDOOFDEOHVWRWKHLUDSSURSULDWHFRQQHFWRUVRQWKHV\VWHPERDUG
6FUHZLQWKHVL[UHDUEDFNSODQHV\VWHPERDUGPRXQWLQJVFUHZV
,I\RXV\VWHPGRHVQRWKDYHDQ03FDUGUHSODFHWKHSRZHUFRQQHFWRUVLQWKHLUVORWVRQWKH
EDFNRIWKHV\VWHPDQGVFUHZLQWKHSRZHUFRQQHFWRUPRXQWLQJVFUHZV
5HSODFHWKHIROORZLQJV\VWHPFRPSRQHQWV
❏
03FDUG
❏
3URFHVVRUDLUIORZJXLGH
❏
6\VWHPIDQV
❏
3&,$*3FDUGFDJH
❏
0HPRU\
5HSODFHWKHV\VWHPFRYHUVUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHVDQGWXUQRQWKH
V\VWHP
9HULI\WKDWWKHSURFHVVRUZRUNV
❏
5XQWKHinfo cpu FRPPDQGDWWKH(),VKHOOSURPSWSDJHRU
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUFKHFNWKHFRQILJXUDWLRQXVLQJWKH(),
System Configuration menuSDJH
5HYLHZWKHV\VWHPFRQILJXUDWLRQLQWKH(),VKHOODQGUHFRQILJXUHVHWWLQJVDVQHFHVVDU\
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–49
Installing or Replacing Parts and Accessories
System Batteries
6\VWHPVZLWKD03FDUGKDYHWZREDWWHULHV6\VWHPVZLWKQR03&DUGKDYHRQO\RQHEDWWHU\
Removing the System Battery
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
5HPRYHWKHSURFHVVRUDLUIORZJXLGH
/LIWXSRQWKHEDWWHU\DQGSXVKRQWKHEDFNRILWZLWKDIODWKHDGVFUHZGULYHUWRUHPRYHWKH
EDWWHU\IURPLWVKROGHU
Ä
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
Remove the System Board Battery
2–50
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing the System Battery
/LIWXSRQWKHEDWWHU\KROGHUUHWDLQLQJFOLSZLWKDIODWKHDGVFUHZGULYHUDQGVOLGHWKHEDWWHU\
LQWRLWVKROGHU7KHSRVLWLYH(+)VLGHRIWKHEDWWHU\VKRXOGIDFHXS
Ä
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
5HSODFHWKHSURFHVVRUDLUIORZJXLGH
5HSODFHWKHV\VWHPFRYHUVUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHVDQGWXUQRQWKH
V\VWHP
Verify that the battery has been installed correctly:
❏
5XQWKHtime DQGdate FRPPDQGVDWWKH(),VKHOOSURPSWSDJHRU
❏
2QV\VWHPVZLWKILUPZDUHYHUVLRQRUKLJKHUDGMXVWWKHWLPHDQGGDWHVHWWLQJVXVLQJ
WKH(),System Configuration menuSDJH
<RXPD\QHHGWRUHVHWWKHV\VWHPWLPHDQGGDWHXVLQJWKH(),timeDQGdateFRPPDQGV
2QFH\RXKDYHVHWWKHWLPHWXUQWKHV\VWHPRIIXQSOXJWKHSRZHUFRUGDQGZDLWIRUDPLQXWH
EHIRUHWXUQLQJLWEDFNRQ([HFXWHWKHtime DQGdateFRPPDQGVDJDLQ,IWKHWLPHDQGGDWH
DUHQRZFRUUHFW\RXKDYHLQVWDOOHGWKHEDWWHU\FRUUHFWO\
Removing the MP Card Battery
5HPRYHWKH03FDUGIURPWKHV\VWHP
/LIWXSRQWKHEDWWHU\DQGSXVKRQWKHEDFNRILWZLWKDVPDOOIODWKHDGVFUHZGULYHU7KLVZLOO
UHPRYHWKHEDWWHU\IURPLWVKROGHU
Ä
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
+
Remove the MP card’s Battery
Replacing the MP Card Battery
/LIWXSRQWKHEDWWHU\KROGHUUHWDLQLQJFOLSZLWKDVPDOOIODWKHDGVFUHZGULYHUDQGVOLGHWKH
EDWWHU\LQWRLWVKROGHU7KHSRVLWLYH(+)VLGHRIWKHEDWWHU\VKRXOGIDFHXS
Ä
CAUTION: Lift the battery just high enough to clear its holder. Too much stress on the battery holder
retaining clip may break it.
5HLQVWDOOWKH03FDUGLQWKHV\VWHP
5HSODFHWKHV\VWHPFRYHUVDQGUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–51
Installing or Replacing Parts and Accessories
Power Supply Interface Module
7KHSRZHUVXSSO\LQWHUIDFH36,PRGXOHVXSSRUWVXSWRWZRUHGXQGDQWSRZHUVXSSOLHV
Removing the Power Supply Interface
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
5HPRYHWKHV\VWHPERDUG
/LIWWKHSRZHUFDEOHVRXWRIWKHLUPHWDOKROGLQJFOLSV
Power Cables and Holding Clips
8QVFUHZWKH36,PRXQWLQJVFUHZDQGUHPRYHWKH36,PRGXOHIURPWKHV\VWHP
2
1
3
Removing the Power Supply Interface Module
2–52
1
Remove Mounting Screw
2
Slide PSI out of Chassis
3
PSI Removed from System
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
Replacing the Power Supply Interface Module
3ODFHWKH36,PRGXOHLQWRWKHFKDVVLVE\VOLGLQJWKHPRGXOHUHWDLQLQJWDELQWRWKHVORWRQWKH
KDUGGLVNGULYHED\ZDOO
Replacing the Power Supply Interface Module
6FUHZLQWKH36,PRGXOHPRXQWLQJVFUHZDQGVHFXUHWKHSRZHUFDEOHVEHKLQGWKHKROGLQJ
FOLSV
1
2
Securing the Power Supply Interface Module and Cables
5HSODFHWKHV\VWHPERDUG
5HSODFHWKHV\VWHPFRYHUVDQGUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–53
Installing or Replacing Parts and Accessories
Hard Drive Backplane
7KHKDUGGULYHEDFNSODQHSURYLGHVFRQQHFWRUVIRUWKUHHKDUGGLVNGULYHV
Removing the Hard Drive Backplane
7XUQRIIWKHV\VWHPGLVFRQQHFWDOOSRZHUDQGH[WHUQDOFDEOHVDQGUHPRYHWKHV\VWHP
FRYHUV
/LIWXSRQWKH3&,$*3FDJHUHOHDVHOHYHUDQGWKHEDFNHGJHRIWKH3&,$*3FDJHDQGOLIW
WKH3&,$*3FDJHRXWRIWKHV\VWHP
+
/LIWXSRQWKHIDQSRZHUEULGJHDQGGLVFRQQHFWWKHEDFNSODQHSRZHUFDEOH
1
2
Disconnect the Fan and Backplane Power Cables
'LVFRQQHFWWKH6&6,FDEOHVDQGXQVFUHZWKHEDFNSODQHPRXQWLQJVFUHZV
1
2
Unscrewing the Backplane Mounting Screws
2–54
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Installing or Replacing Parts and Accessories
5HPRYHWKHKDUGGULYHEDFNSODQHE\VOLGLQJLWLQWKHGLUHFWLRQRIWKHDUURZDQGSXOOLQJLW
RXWZDUGIURPLWVVWDQGRIISRVWV
1
2
Remove the Hard Drive Backplane
Replacing the Hard Drive Backplane
,QVHUWWKHKDUGGULYHEDFNSODQHRQWRLWVIRXUFKDVVLVVWDQGRIIVDQGVOLGHLWWRWKHOHIWDV\RX
IDFHLW7KLVORFNVWKHKDUGGULYHEDFNSODQHLQSODFH
6FUHZLQWKHWZREDFNSODQHPRXQWLQJVFUHZVDQGFRQQHFWWKHWZR6&6,FDEOHV
&RQQHFWWKHEDFNSODQHSRZHUFDEOHDQGORZHUWKHIDQSRZHUEULGJHXQWLOLWVQDSVLQSODFH
5HSODFHWKH3&,$*3FDJHLQWKHV\VWHPDQGVHFXUHLW
5HSODFHWKHV\VWHPFRYHUVDQGUHFRQQHFWDOORIWKHSRZHUDQGH[WHUQDOFDEOHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
2–55
Installing or Replacing Parts and Accessories
2–56
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3
System Configuration
7KLVFKDSWHUFRYHUVWKHWRROVDYDLODEOHIRUFRQILJXULQJU[DQG][V\VWHPV
■
([WHQVLEOH)LUPZDUH,QWHUIDFH(),
■
0DQDJHPHQW3URFHVVRU03
■
%DVHERDUG0DQDJHPHQW&RQWUROOHU%0&
■
)LUPZDUH8SJUDGHV
Extensible Firmware Interface (EFI)
7KH([WHQVLEOH)LUPZDUH,QWHUIDFH(),LVDQLQWHUIDFHEHWZHHQWKHRSHUDWLQJV\VWHPVDQGWKH
V\VWHPILUPZDUH
7KHIROORZLQJWRSLFVLQWURGXFH\RXWRWKH(),DQGH[SODLQKRZWRXVHLWWRFRQILJXUH\RXU
V\VWHP
■
¦$FFHVVLQJWKH(),§RQSDJH
■
¦8VLQJWKH(),VKHOO§RQSDJH
■
¦8VLQJWKH%RRW2SWLRQ0DLQWHQDQFH0HQX§RQSDJH
■
¦8VLQJWKH6\VWHP&RQILJXUDWLRQ0HQX§RQSDJH
■
¦8VLQJWKH6HFXULW\3DVVZRUG0HQX§RQSDJH
7KH(),LVDQLQWHUIDFHWKDWDOORZV\RXWRFRQILJXUHWKH,WDQLXP3URFHVVRU)DPLO\,3)
ILUPZDUH7KH(),PHQXLQFOXGHVWKHIROORZLQJRSWLRQV
■
7KHEFI Shell [Built-in]LVDFRPPDQGOLQHLQWHUIDFHWKDWDOORZV\RXWRRSHUDWHWKH(),
FRPPDQGVRUFUHDWHDQGUXQDXWRPDWHGVFULSWV
■
Boot Option Maintenance MenuDOORZV\RXWRVHOHFWWKHRUGHURIWKHGHYLFHVIURP
ZKLFK\RXZDQWWKHILUPZDUHWRDWWHPSWWRERRWWKH26<RXFDQDOVRFRQILJXUHWKHV\VWHPWR
ERRWIURPDFRQILJXUDWLRQILOH
■
System Configuration Menu RQV\VWHPVZLWK EFI firmware version 2.0 or higher OHWV\RX
YLHZWKHV\VWHPFRQILJXUDWLRQDQGFKDQJHRUGHOHWHDGPLQLVWUDWRUDQGXVHUSDVVZRUGV
■
Security/Password MenuRQV\VWHPVZLWKEFI firmware version 1.9 or lower OHWV\RXDGG
FKDQJHDQGGHOHWHV\VWHPDGPLQLVWUDWRUDQGXVHUSDVVZRUGV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–1
System Configuration
Accessing the EFI
<RXFDQDFFHVVWKH(),GLUHFWO\ZKHQ\RXERRWWKHV\VWHPRUE\UHPRWHDFFHVV
127(7RVZLWFKEHWZHHQWKH03FDUGDQG(),FRQVROHZLWK03ILUPZDUH(RUKLJKHU
VHH¦$FFHVVLQJWKH03²SDJH
■ ,I\RXDUHDWWKH(),FRQVROHSUHVVCtrl-BWRDFFHVVWKH03ORJLQVFUHHQ
■ ,I\RXDUHDWWKH03FRPPDQGSURPSWH[HFXWHWKHCOFRPPDQGWRHQWHU(),FRQVROH
PRGH
Direct Access
:KHQ\RXWXUQRQ\RXUV\VWHPDQGLWEHJLQVWRVWDUWXS\RXUV\VWHPSDXVHVDWWKHboot option
VFUHHQ
EFI Boot Manager ver x.xx [xx.xx]
Please select a boot option
[\RXU26]
EFI Shell [Built-in]
Boot option maintenance menu
Security/Password Menu
Use up and down arrows to change option(s).
Use Enter to select an option.
127(7KHV\VWHPSDXVHVIRUVHYHQVHFRQGVWRDOORZ\RXWRFKDQJHWKHERRWRSWLRQEHIRUH
ERRWLQJWRWKHGHIDXOW267RFKDQJHWKHSDXVHGXUDWLRQVHOHFWSet Auto Boot TimeOutIURP
WKHBoot Options Maintenance MenuSDJH
8VHWKHXSRUGRZQDUURZNH\VWRKLJKOLJKWDQRSWLRQWKHQSUHVVEnterWRDFWLYDWHDVHOHFWLRQ
3–2
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Remote Access
7RDFFHVVWKH(),UHPRWHO\
:LWKWKHV\VWHPWXUQHGRIIFRQQHFWWKHVHULDOFDEOHSURYLGHGZLWK\RXUV\VWHP+3SDUW
QXPEHURUDFRPSDWLEOHFDEOHWRVHULDOSRUW$RQWKHUHDUSDQHORIWKHV\VWHP
DQGWR\RXUUHPRWHGHYLFH
&RQILJXUHWKHWHUPLQDOHPXODWLRQVRIWZDUHZLWKWKHVHVHWWLQJV
❏
%DXGUDWH
❏
%LWV
❏
3DULW\1RQH
❏
6WRS%LWVRQH
❏
)ORZ&RQWURO;21;2))
8VLQJWKHWHUPLQDOHPXODWLRQVRIWZDUHFRQQHFWWRWKHV\VWHPZLWKDGLUHFWFRQQHFWLRQ
127(7KHGHIDXOWWHUPLQDOHPXODWLRQW\SHLV977KLVVHWWLQJFDQEHFKDQJHGIURPWKH
(),Boot Options Maintenance Menu
7XUQRQWKHV\VWHPDQGIROORZWKHVWHSVLQWKHQH[WVHFWLRQWRDFFHVVWKH(),
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–3
System Configuration
Using the EFI shell
7RDFFHVVWKH(),VKHOO
:KHQWKH(),ERRWRSWLRQVFUHHQGLVSOD\VXVHWKHDUURZNH\VWRKLJKOLJKWEFI ShellWKHQ
SUHVVEnter
127(<RXKDYHVHFRQGVWRFKDQJHWKHERRWRSWLRQEHIRUHWKHV\VWHPERRWVWRWKHILUVWRSWLRQ
LQWKHOLVW7RFKDQJHWKHRUGHURIERRWRSWLRQVVHH¦8VLQJWKH%RRW2SWLRQ0DLQWHQDQFH0HQX§
RQSDJH
$OLVWRIILOHV\VWHPVGULYHVDQGSDUWLWLRQVDQGEORFNGHYLFHVRQKDUGGULYHVLVGLVSOD\HG
)RUH[DPSOH
Device mapping table
fs0:
Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)/HD(Part1,Sig00112233)
blk0: Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)
blk1: Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)
7KH(),VKHOOILUVWVHDUFKHVIRUDQRSWLRQDOVFULSWILOHQDPHGstartup.nsh
❏
,IWKLVILOHLVIRXQGLWLVH[HFXWHGDXWRPDWLFDOO\
❏
$IWHUWKHVFULSWUXQVWKHVKHOOZDLWVIRUFRPPDQGVWREHHQWHUHGDWWKHFRPPDQGSURPSW
127(,Istartup.nshUXQVDQ26RUDSSOLFDWLRQ\RXPXVWH[LWWKDWDSSOLFDWLRQWRDFFHVVWKH
(),VKHOOSURPSW
<RXFDQQRZHQWHUFRPPDQGV
❏
7RUXQDQLQGLYLGXDOFRPPDQG
D 7\SHWKHFRPPDQGDWWKHVKHOOSURPSW)RUH[DPSOHWRFOHDUWKHGLVSOD\RQWKH
PRQLWRU
Shell:\> cls
E 3UHVVEnterWRH[HFXWHWKHFRPPDQG
◆
6RPHFRPPDQGVUHTXLUHDGGLWLRQDODUJXPHQWVWRIXUWKHUGHILQHWKHLUDFWLRQ)RU
H[DPSOHWRGLVSOD\LQIRUPDWLRQDERXWWKHV\VWHPPHPRU\\RXPXVWW\SHWKH
FRPPDQGQDPHSOXVWKHGHVLUHGFDWHJRU\RILQIRUPDWLRQWRGLVSOD\
fs0:\> info mem
◆
❏
:KHQ\RXHQWHULQGLYLGXDOFRPPDQGVDWWKHFRPPDQGSURPSWWKHVKHOO
SHUIRUPVYDULDEOHVXEVWLWXWLRQWKHQH[SDQGVZLOGFDUGVEHIRUHWKHFRPPDQGLV
H[HFXWHG
7RVZLWFKWRDGLIIHUHQWILOHV\VWHPH[HFXWHWKHIROORZLQJZKHUHfsxLVWKHVHOHFWHGILOH
V\VWHPDVOLVWHGRQWKHVFUHHQVHHVWHS)RUH[DPSOH
Shell> fsx:
ZKHUHxLVDQXPHULFYDOXHUHSUHVHQWLQJDILOHV\VWHP)RUH[DPSOHLI\RXHQWHU
Shell> fs0:
<RXVHHWKLVSURPSW
fs0:\> _
3–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
❏
<RXDOVRFDQUXQ(),DSSOLFDWLRQVILOHVHQGLQJZLWK.efi7ROLVWDSSOLFDWLRQVLQWKH
FXUUHQWILOHV\VWHPUXQWKHlsFRPPDQG)RUH[DPSOH
fs0:> ls
<RXZLOOVHHDOLVWRIDSSOLFDWLRQVRQWKHIVILOHV\VWHP
Command Syntax
7KH(),VKHOOXVHVDSURJUDPPLQJODQJXDJHWRFRQWUROWKHH[HFXWLRQRILQGLYLGXDOFRPPDQGV
6RPHFKDUDFWHUVKDYHVSHFLDOPHDQLQJVLQWKH(),VKHOO7KLVVHFWLRQLQFOXGHVLQVWUXFWLRQVIRU
UXQQLQJ(),VKHOOFRPPDQGVDQGDOLVWRIWKHDYDLODEOHFRPPDQGV
Arguments
Some commands require additional arguments to further define their action. For example, to
display information about the system memory, you must type the command name, plus the
desired category of information to display:
fs0:\> info mem
Rules
)ROORZWKHVHUXOHVRUWKHFRPPDQGVZLOOQRWUXQFRUUHFWO\
#
'HQRWHVDFRPPHQW$OOWH[WIURPWKH#V\PEROWRWKHHQGRIWKHOLQHLV
LJQRUHG
>
'HQRWHVDQRXWSXWUHGLUHFW2XWSXWRI(),VKHOOFRPPDQGVFDQEHVDYHGWR
ILOHVLQVWHDGRIEHLQJGLVSOD\HGRQWKHPRQLWRURULQWKHWHUPLQDOHPXODWLRQ
SURJUDP7KHVKHOOUHGLUHFWVVWDQGDUGRXWSXWWRDVLQJOHILOHDQGVWDQGDUGHUURU
WRDVLQJOHILOH5HGLUHFWLQJERWKVWDQGDUGRXWSXWDQGVWDQGDUGHUURUWRWKH
VDPHILOHLVDOORZHG5HGLUHFWLQJWRPRUHWKDQRQHILOHRQWKHVDPHFRPPDQG
LVQRWVXSSRUWHG
7KHRXWSXWUHGLUHFWRSWLRQVLQFOXGH
>
UHGLUHFWRXWSXWWRDXQLFRGHILOH
>a
UHGLUHFWRXWSXWWRDQ$6&,,ILOH
>>
DSSHQGRXWSXWWRDXQLFRGHILOH
>>a
DSSHQGRXWSXWWRDQ$6&,,ILOH
7KHV\QWD[IRUUHGLUHFWLQJVFULSWRXWSXWLV
Command > output_file_pathname
%
'HQRWHVDQHQYLURQPHQWYDULDEOH(QYLURQPHQWYDULDEOHVFDQEHVHWDQG
YLHZHGWKURXJKWKHXVHRIWKHsetFRPPDQGVHHsetFRPPDQGLQWKLV
FKDSWHU7RDFFHVVWKHYDOXHRIDQHQYLURQPHQWYDULDEOHDVDQDUJXPHQWWRD
VKHOOFRPPDQGGHOLPLWWKHQDPHRIWKHYDULDEOHZLWKWKH%FKDUDFWHUEHIRUH
DQGDIWHUWKHYDULDEOHQDPHIRUH[DPSOH%myvariable%
*
'HQRWHVDZLOGFDUGFKDUDFWHU0DWFKHV]HURRUPRUHFKDUDFWHUVLQDILOHQDPH
?
'HQRWHVDZLOGFDUGFKDUDFWHU0DWFKHVH[DFWO\RQHFKDUDFWHURIDILOHQDPH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–5
System Configuration
3–6
[
'HQRWHVDZLOGFDUGFKDUDFWHU'HILQHVDVHWRIFKDUDFWHUVWKHSDWWHUQPDWFKHV
DQ\VLQJOHFKDUDFWHULQWKHVHW&KDUDFWHUVLQWKHVHWDUHQRWVHSDUDWHG5DQJHV
RIFKDUDFWHUVFDQEHVSHFLILHGE\VSHFLI\LQJWKHILUVWFKDUDFWHULQDUDQJHWKHQ
WKH-FKDUDFWHUWKHQWKHODVWFKDUDFWHULQWKHUDQJH)RUH[DPSOH[a-zA-Z]
^
'HQRWHVDOLWHUDODUJXPHQW:KHQDFRPPDQGFRQWDLQVDGHILQHGDOLDVWKH
VKHOOUHSODFHVWKHDOLDVZLWKLWVGHILQLWLRQVHHaliasFRPPDQGLQWKLVFKDSWHU
,IWKHDUJXPHQWLVSUHIL[HGZLWKWKH^FKDUDFWHUKRZHYHUWKHDUJXPHQWLV
WUHDWHGDVDOLWHUDODUJXPHQWDQGDOLDVSURFHVVLQJLVQRWSHUIRUPHG
“”
4XRWDWLRQPDUNVLQWKH(),VKHOODUHXVHGIRUDUJXPHQWJURXSLQJ$TXRWHG
VWULQJLVWUHDWHGDVDVLQJOHDUJXPHQWWRDFRPPDQGDQGDQ\ZKLWHVSDFH
FKDUDFWHUVLQFOXGHGLQWKHTXRWHGVWULQJDUHMXVWSDUWRIWKDWVLQJOHDUJXPHQW
4XRWLQJDQHQYLURQPHQWYDULDEOHGRHVQRWKDYHDQ\HIIHFWRQWKH
GHUHIHUHQFLQJRIWKDWYDULDEOH'RXEOHTXRWDWLRQPDUNV¦§GHQRWHVWULQJV
6LQJOHTXRWDWLRQPDUNVDUHQRWWUHDWHGVSHFLDOO\E\WKHVKHOOLQDQ\ZD\
(PSW\VWULQJVDUHWUHDWHGDVYDOLGFRPPDQGOLQHDUJXPHQWV
space
8VHGWRIRUPDWEDWFKVFULSWVWRVHSDUDWHFRPPDQGQDPHVSDUDPHWHUVDQGVR
IRUWK
newline
8VHGWRIRUPDWEDWFKVFULSWV(DFKOLQHUHSUHVHQWVDQHZFRPPDQG
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Command Descriptions
7KHIROORZLQJVHFWLRQVSURYLGHEULHIGHVFULSWLRQVRIWKH(),FRPPDQGV)RUPRUHLQIRUPDWLRQ
XVHWKH(),VKHOOKHOSV\VWHP7RDFFHVVD
■
/LVWRI(),FRPPDQGFODVVHVH[HFXWHhelp DWWKH(),VKHOOSURPSW
■
'HWDLOHGGHVFULSWLRQRIDFRPPDQGH[HFXWHhelpDQGWKHFRPPDQGQDPHRURWKHURSWLRQV
DWWKH(),VKHOOSURPSW)RUH[DPSOH
❏
fs0:\> help GLVSOD\VDOLVWRIFRPPDQGFODVVHV
❏
fs0:\> help date GLVSOD\VKHOSIRUWKHdateFRPPDQG
❏
fs0:\> help -a GLVSOD\VDOOFRPPDQGVLQDOSKDEHWLFDORUGHU
❏
fs0:\> help -a -b GLVSOD\VDOOFRPPDQGVLQDOSKDEHWLFDORUGHUZLWKSDJHEUHDNV
❏
fs0:\> help class GLVSOD\VDOOFRPPDQGVLQWKHVSHFLILHGFRPPDQGFODVVVHH
EHORZ
Command Classes
(),FRPPDQGVDUHRUJDQL]HGLQWRGLIIHUHQWFODVVHVEDVHGRQWKHLUIXQFWLRQV7KHFODVVHVLQFOXGH
boot
%RRWRSWLRQVDQGGLVNUHODWHGFRPPDQGV
configuration &KDQJHDQGUHWULHYHV\VWHPLQIRUPDWLRQ
device
*HWGHYLFHGULYHUDQGKDQGOHLQIRUPDWLRQ
memory
0HPRU\UHODWHGFRPPDQGV
shell
%DVLFVKHOOQDYLJDWLRQDQGFXVWRPL]DWLRQ
scripts
(),VKHOOVFULSWFRPPDQGV
Boot Commands
7KHVHOHW\RXVHWERRWDQGGLVNRSWLRQV
autoboot
9LHZRUVHWDXWRERRWWLPHRXWYDULDEOH
bcfg
'LVSOD\PRGLI\WKHGULYHUERRWFRQILJXUDWLRQ
dblk
'LVSOD\WKHFRQWHQWVRIEORFNVIURPDEORFNGHYLFH
boottest
6HWYLHZ%RRW7HVWELWV
mount
0RXQWDILOHV\VWHPRQDEORFNGHYLFH
reset
5HVHWWKHV\VWHP
vol
'LVSOD\YROXPHLQIRUPDWLRQRIWKHILOHV\VWHP
Configuration Commands
7KHVHOHW\RXFKDQJHDQGUHWULHYHV\VWHPLQIRUPDWLRQ
cpuconfig
'HFRQILJXUHRUUHFRQILJXUH&38V
date
'LVSOD\WKHFXUUHQWGDWHRUVHWVWKHGDWHLQWKHV\VWHP
IRUPDWLVmm/dd/yyyy
err
'LVSOD\RUFKDQJHWKHHUURUOHYHO
errdump
9LHZFOHDUORJV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–7
System Configuration
info
'LVSOD\KDUGZDUHLQIRUPDWLRQ
monarch
9LHZRUVHWWKHPRQDUFKSURFHVVRU
palproc
0DNHD3$/SURFHGXUHFDOO
salproc
0DNHD6$/SURFHGXUHFDOO
time
'LVSOD\WKHFXUUHQWWLPHRUVHWVWKHV\VWHPWLPHIRUPDWLVhh:mm:ss
ver
'LVSOD\WKHYHUVLRQLQIRUPDWLRQ
Device Commands
7KHVHSURYLGHGHYLFHGULYHUDQGKDQGOHLQIRUPDWLRQ
baud
6HWVHULDOSRUWVHWWLQJV
connect
%LQGDQ(),GULYHUWRDGHYLFHDQGVWDUWWKHGULYHU
devices
'LVSOD\WKHOLVWRIGHYLFHVEHLQJPDQDJHGE\(),GULYHUV
devtree
'LVSOD\WKHWUHHRIGHYLFHVWKDWIROORZWKH(),'ULYHU0RGHO
disconnect
'LVFRQQHFWRQHRUPRUHGULYHUVIURPDGHYLFH
dh
'LVSOD\WKHKDQGOHVLQWKH(),HQYLURQPHQW
driver
/LVWDQGLQVWDOO520EDVHGGULYHUV
drivers
'LVSOD\WKHOLVWRIGULYHUVWKDWIROORZWKH(),'ULYHU0RGHO
drvcfg
,QYRNHWKH'ULYHU&RQILJXUDWLRQ3URWRFRO
drvdiag
,QYRNHWKH'ULYHU'LDJQRVWLFV3URWRFRO
guid
'LVSOD\DOOWKH*8,'VLQWKH(),HQYLURQPHQW
lanaddress
'LVSOD\FRUH,20$&DGGUHVV
load
/RDGDQGRSWLRQDOO\FRQQHFW(),GULYHUV
loadpcirom
/RDGD3&,2SWLRQ520
map
'LVSOD\RUGHILQHPDSSLQJV
openinfo
'LVSOD\WKHSURWRFROVRQDKDQGOHDQGWKHDJHQWV
pci
'LVSOD\3&,GHYLFHVRU3&,IXQFWLRQFRQILJXUDWLRQVSDFH
reconnect
5HFRQQHFWRQHRUPRUHGULYHUVIURPDGHYLFH
unload
8QORDGDSURWRFROLPDJH
Memory Commands
7KHVHOHW\RXPDQDJH\RXUPHPRU\
3–8
default
5HVHWDOO190YDOXHVWRV\VWHPGHIDXOWV
dmpstore
'LVSOD\DOO195$0YDULDEOHV
dmem
'LVSOD\WKHFRQWHQWVRIPHPRU\
memmap
'LVSOD\WKHPHPRU\PDS
mm
'LVSOD\RUPRGLI\PHPRU\PHPRU\PDSSHG,2DQG3&,VHWWLQJV
pdt
9LHZRUFOHDUWKH3DJH'HDOORFDWLRQ7DEOH3'7
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Shell Commands
7KHVHOHW\RXQDYLJDWHDQGFXVWRPL]H\RXUVKHOO
alias
'LVSOD\FUHDWHRUGHOHWHVDOLDVHVLQWKH(),VKHOO
attrib
'LVSOD\RUFKDQJHWKHDWWULEXWHVRIILOHVRUGLUHFWRULHV
cd
'LVSOD\RUFKDQJHWKHFXUUHQWGLUHFWRU\
cls
&OHDUWKHVWDQGDUGRXWSXWZLWKDQRSWLRQDOEDFNJURXQGFRORU
comp
&RPSDUHWKHFRQWHQWVRIWZRILOHV
cp
&RS\RQHRUPRUHILOHVGLUHFWRULHVWRDQRWKHUORFDWLRQ
edit
(GLWDQ$6&,,RU81,&2'(ILOHLQIXOOVFUHHQ
eficompress
&RPSUHVVDILOH
efidecompress 8QFRPSUHVVDILOH
exit
([LWWKH(),VKHOO
help
'LVSOD\KHOSPHQXVFRPPDQGOLVWRUYHUERVHKHOSRIDFRPPDQG
hexedit
(GLWZLWKKH[PRGHLQIXOOVFUHHQ
ls
'LVSOD\DOLVWRIILOHVDQGVXEGLUHFWRULHVLQDGLUHFWRU\
mkdir
&UHDWHRQHRUPRUHGLUHFWRULHV
mode
'LVSOD\RUFKDQJHWKHPRGHRIWKHFRQVROHRXWSXWGHYLFH
mv
0RYHRQHRUPRUHILOHVGLUHFWRULHVWRGHVWLQDWLRQ
rm
'HOHWHRQHRUPRUHILOHVRUGLUHFWRULHV
set
'LVSOD\FUHDWHFKDQJHRUGHOHWH(),HQYLURQPHQWYDULDEOHV
setsize
6HWWKHVL]HRIWKHILOH
touch
8SGDWHWLPHZLWKFXUUHQWWLPH
type
'LVSOD\WKHFRQWHQWVRIDILOH
xchar
7XUQRQRIIH[WHQGHGFKDUDFWHUIHDWXUHV
Scripts Commands
7KHVHOHW\RXXVHVKHOOVFULSWV
echo
'LVSOD\PHVVDJHVRUWXUQFRPPDQGHFKRLQJRQRURII
for/endfor
([HFXWHFRPPDQGVIRUHDFKLWHPLQDVHWRILWHPV
goto
0DNHEDWFKILOHH[HFXWLRQMXPSWRDQRWKHUORFDWLRQ
if/endif
([HFXWHFRPPDQGVLQVSHFLILHGFRQGLWLRQV
pause
3ULQWDPHVVDJHDQGVXVSHQGVIRUNH\ERDUGLQSXW
stall
6WDOOVWKHSURFHVVRUIRUWKHVSHFLILHGWLPHLQPLFURVHFRQGV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–9
System Configuration
EFI Scripts
7KH(),VFULSWLQJODQJXDJHDOORZV\RXWRFUHDWHH[HFXWDEOHVKHOOVFULSWV<RXFDQSODFHDVHWRI
(),FRPPDQGVLQWKHVKHOOVFULSWWKHQH[HFXWHWKHVFULSWDVRIWHQDVQHHGHG<RXDOVRFDQPRGLI\
WKHVFULSWWRPDNHLWSHUIRUPGLIIHUHQWWDVNV6FULSWILOHVFDQEHHLWKHUXQLFRGHRU$6&,,IRUPDW
127(&RPPDQGVH[HFXWHGIURPDEDWFKVFULSWDUHQRWVDYHGE\WKHVKHOOIRU'26NH\KLVWRU\
XSDUURZFRPPDQGUHFDOO
7KHRSWLRQDOVFULSWstartup.nshLVDXWRPDWLFDOO\H[HFXWHGZKHQ\RXHQWHUWKH(),VKHOO
HQYLURQPHQW$OO(),VKHOOVFULSWVKDYHWKH.nshVXIIL[
7KLVVHFWLRQSURYLGHVDEULHIH[SODQDWLRQRIKRZWRFUHDWHHGLWDQGUXQDQ(),VKHOOVFULSW
7RFUHDWHRUHGLWDVKHOOVFULSW
$WWKH(),VKHOOSURPSWUXQWKHVKHOO©VHGLWRU([HFXWH
fs0:\> edit file.nsh
ZKHUHILOHQVKUHSUHVHQWVWKHQDPHRIWKHQHZVKHOOVFULSW\RXDUHFUHDWLQJRUWKHH[LVWLQJ
VFULSW\RXZDQWWRHGLW
7\SHRUHGLWWKHFRPPDQGVWREHH[HFXWHGZKHQWKHVFULSWLVUXQ)RUH[DPSOH
echo This is a test file.
:KHQ\RXDUHILQLVKHGZULWLQJWKHVFULSWSUHVVF2WRVDYHWKHILOHWKHQSUHVVF3WRH[LW
7KH(),HGLWRULVFRQWUROOHGE\IXQFWLRQNH\FRPPDQGV$PHQXRIDYDLODEOHFRPPDQGVLV
VKRZQDWWKHERWWRPRIWKHVFUHHQ,I\RXDUHDFFHVVLQJWKHHGLWRUWKURXJKDWHUPLQDOHPXODWRU
DQGWKHIXQFWLRQNH\VGRQRWZRUNXVHWKHHVFDSHVHTXHQFHVOLVWHGKHUH
Command
Function key
Escape sequence
Open file
F1
Esc 0
Save file
F2
Esc S
Exit
F3
Esc Q
Cut
F4
Esc D
Paste
F5
Esc P
Goto
F6
Esc G
Search
F7
Esc F
Replace
F8
Esc R
File type
F9
Esc T
7RUXQDVKHOOVFULSW
7\SHWKHQDPHRIWKHFRPPDQGDWWKH(),VKHOOSURPSW)RUH[DPSOH
fs0:\> mytest.nsh
3UHVVEnter
3–10
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Positional Arguments
8SWRQLQHSRVLWLRQDODUJXPHQWVDUHVXSSRUWHGIRUEDWFKVFULSWV3RVLWLRQDODUJXPHQWVXEVWLWXWLRQ
LVSHUIRUPHGEHIRUHWKHH[HFXWLRQRIHDFKOLQHLQWKHVFULSWILOH3RVLWLRQDODUJXPHQWVDUHGHQRWHG
E\%nZKHUHnLVDGLJLWEHWZHHQDQG%\FRQYHQWLRQ%0LVWKHQDPHRIWKHVFULSWILOH
FXUUHQWO\EHLQJH[HFXWHG
,QEDWFKVFULSWVDUJXPHQWVXEVWLWXWLRQLVSHUIRUPHGILUVWWKHQYDULDEOHVXEVWLWXWLRQ7KXVIRUD
YDULDEOHFRQWDLQLQJ%2WKHYDULDEOHZLOOEHUHSODFHGZLWKWKHOLWHUDOVWULQJ%2QRWWKHVHFRQG
DUJXPHQWRQWKHFRPPDQGOLQH,IQRUHDODUJXPHQWLVIRXQGWRVXEVWLWXWHIRUDSRVLWLRQDO
DUJXPHQWWKHQWKHSRVLWLRQDODUJXPHQWLVLJQRUHG
)RUH[DPSOHWKLVVFULSWUHSODFHVWKHWZROLWHUDODUJXPHQWVarg1DQGarg2ZLWKWKHSRVLWLRQDO
DUJXPHQWV%1DQG%2:
#
# Example: EFI Shell Script
#
#///////////////////////////////////////
echo -off
set arg1 %1
set arg2 %2
echo "I found a %arg1%"
echo "I also found a %arg2%"
To run the command, type the command name followed by the arguments at the shell
prompt:
fs0:\efi\tools> example cat dog
example> echo -off
I found a cat
I also found a dog
Nesting
6FULSWILOHH[HFXWLRQFDQEHQHVWHGWKDWLVVFULSWILOHVPD\EHH[HFXWHGIURPZLWKLQRWKHUVFULSW
ILOHV5HFXUVLRQLVDOORZHG
Output Redirection
2XWSXWUHGLUHFWLRQLVIXOO\VXSSRUWHG2XWSXWUHGLUHFWLRQRQDFRPPDQGLQDVFULSWILOHFDXVHVWKH
RXWSXWIRUWKDWFRPPDQGWREHUHGLUHFWHG2XWSXWUHGLUHFWLRQRQWKHLQYRFDWLRQRIDEDWFKVFULSW
FDXVHVWKHRXWSXWIRUDOOFRPPDQGVLQWKHEDWFKVFULSWWREHUHGLUHFWHGWRWKHILOHZLWKWKHRXWSXW
RIHDFKFRPPDQGDSSHQGHGWRWKHHQGRIWKHILOH
%\GHIDXOWERWKWKHLQSXWDQGRXWSXWIRUDOOFRPPDQGVH[HFXWHGIURPDEDWFKVFULSWDUHHFKRHG
WRWKHFRQVROH'LVSOD\RIFRPPDQGVUHDGIURPDEDWFKILOHFDQEHVXSSUHVVHGYLDWKHecho -off
FRPPDQGVHHecho,IRXWSXWIRUDFRPPDQGLVUHGLUHFWHGWRDILOHWKHQWKDWRXWSXWLVQRW
GLVSOD\HGRQWKHFRQVROH
Error Handling in Scripts
%\GHIDXOWLIDQHUURULVHQFRXQWHUHGGXULQJWKHH[HFXWLRQRIDFRPPDQGLQDEDWFKVFULSWWKH
VFULSWZLOOFRQWLQXHWRH[HFXWH7KHlasterrorVKHOOYDULDEOHDOORZVEDWFKVFULSWVWRWHVWWKHUHVXOWV
RIWKHPRVWUHFHQWO\H[HFXWHGFRPPDQGXVLQJWKHifFRPPDQG7KLVYDULDEOHLVQRWDQ
HQYLURQPHQWYDULDEOHEXWLVDVSHFLDOYDULDEOHPDLQWDLQHGE\WKHVKHOOIRUWKHOLIHWLPHRIWKDW
LQVWDQFHRIWKHVKHOO
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–11
System Configuration
Comments in Script Files
&RPPHQWVFDQEHHPEHGGHGLQEDWFKVFULSWV7KH#FKDUDFWHURQDOLQHGHQRWHVWKDWDOOFKDUDFWHUV
RQWKHVDPHOLQHDQGWRWKHULJKWRIWKH#DUHWREHLJQRUHGE\WKHVKHOO&RPPHQWVDUHQRWHFKRHG
WRWKHFRQVROH
Using the Boot Option Maintenance Menu
7KLVPHQXDOORZV\RXWRVHOHFWFRQVROHRXWSXWDQGLQSXWGHYLFHVDVZHOODVYDULRXVERRWRSWLRQV
,WFRQWDLQVWKHIROORZLQJLWHPV
■
■
■
■
■
■
■
■
■
■
■
Boot from a File
Add a Boot Option
Delete Boot Option(s)
Change Boot Order
Manage BootNext setting
Set Auto Boot TimeOut
Select Active Console Output Devices
Select Active Console Input Devices
Select Active Standard Error Devices
Cold Reset
Exit
7KHVHLWHPVDUHGHVFULEHGLQWKHIROORZLQJVHFWLRQV
,QDOOPHQXVVHOHFW
■
HelpWRGLVSOD\WKHKHOSDYDLODEOHIRUWKHFRPPDQG
■
ExitWRUHWXUQWRWKHPDLQ%RRW2SWLRQV0DLQWHQDQFHPHQX
■
EnterWRVHOHFWDQLWHPDIWHUXVLQJWKHDUURZNH\VWRKLJKOLJKWWKHLWHP
■
Save Settings to NVRAMWRVDYH\RXUFKDQJHV
127(7KHRSWLRQVVKRZQKHUHDUHH[DPSOHV<RXUV\VWHPPD\KDYHGLIIHUHQWRSWLRQVDYDLODEOH
EDVHGRQWKHV\VWHPFRQILJXUDWLRQDQGLQVWDOOHGKDUGZDUHFRPSRQHQWV
3–12
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Paths
$OOGHYLFHVLQWKHU[DQG][DUHUHSUHVHQWHGE\SDWKVLQWKH(),VKHOO7RLGHQWLI\WKH
FRUUHFWVORWRUGLVNGULYHXVHWKHIROORZLQJWDEOHV
Integrity rx2600 server slots
Slot
Path
Description
1 PCI
Acpi(HWP0002,400)/pci(1|0)
Slot 1:0/4
2 PCI
Acpi(HWP0002,300)/pci(1|0)
Slot 2:0/3
3 PCI
Acpi(HWP0002,200)/pci(1|0)
Slot 3:0/2
4 PCI
Acpi(HWP0002,600)/pci(1|0)
Slot 4:0/5
zx6000 workstation slots
Slot
Path
Description
1 AGP
Acpi(HWP0003,400)/pci(0|0)
Slot 1:0/4 (upper rack slot)
2 PCI
Acpi(HWP0002,300)/pci(1|0)
Slot 2:0/3
3 PCI
Acpi(HWP0002,200)/pci(1|0)
Slot 3:0/2
4 PCI
Acpi(HWP0002,600)/pci(1|0)
Slot 4:0/5 (lower rack slot)
rx2600 and zx6000 drives
Drive
Path
Description
SCSI disk
Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0) 0/1/1/0.0.0 (lower disk)
SCSI disk
Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun1,Lun0) 0/1/1/0.1.0 (middle disk)
SCSI disk
Acpi(HWP0002,100)/Pci(1|1)/Scsi(Pun2,Lun0) 0/1/1/1.2.0 (upper disk)
Removable
media boot
Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–13
System Configuration
Boot from a File
8VHWKLVRSWLRQWRPDQXDOO\UXQDVSHFLILFDSSOLFDWLRQRUGULYHU
127(7KLVRSWLRQERRWVWKHVHOHFWHGDSSOLFDWLRQRUGULYHURQHWLPHRQO\:KHQ\RXH[LWWKH
DSSOLFDWLRQ\RXUHWXUQWRWKLVPHQX
7KLVRSWLRQGLVSOD\VWKHILOHV\VWHPVWKDWDUHRQ\RXUV\VWHPDQGOHWV\RXEURZVHWKHVHILOH
V\VWHPVIRUDSSOLFDWLRQVRUGULYHUVWKDWDUHH[HFXWDEOH([HFXWDEOHILOHVHQGZLWKWKH.efi
H[WHQVLRQ<RXFDQDOVRVHOHFWUHPRWHERRW/$1RSWLRQVWKDWKDYHEHHQFRQILJXUHGRQ\RXU
QHWZRUN
)RUH[DPSOH
Boot From a File. Select a Volume
NO VOLUME LABEL [Acpi(HWP0002,500)/Pci(2|0)/Ata(Primary,Master)/
CD_FORMAT [Acpi(HWP0002,500)/Pci(2|0)/Ata(Secondary,Master)/CDRO
Removable Media Boot [Acpi(HWP0002,500)/Pci(2|0)/Ata(Secondary,M
Load File [EFI Shell [Built-in]]
Load File [Acpi(HWP0002,500)/Pci(3|0)/Mac(00306E385AFB)]
Exit
,QWKLVH[DPSOH
3–14
■
NO VOLUME LABELLVDKDUGGULYH:KHQ\RXIRUPDWDKDUGGULYHWKH(),WRROVSURYLGH
DQRSWLRQWR/$%(/WKHGLVN,QWKLVH[DPSOHWKHYROXPHZDVQRWODEHOOHG
■
CD_FORMATLVWKHODEHOFUHDWHGIRUWKHGLVNFXUUHQWO\LQVLGHWKH'9'520GULYH
■
Removable Media BootDOORZV\RXWRERRWIURPDUHPRYDEOHPHGLDGULYH&''9'
GULYH7KLVRSWLRQGRHVQRWVXSSRUWERRWLQJIURPDVSHFLILFILOHRQDVSHFLILFUHPRYDEOH
PHGLDGLVF
■
7KHWZRLoad FilesDUHWKH(),VKHOODQGWKH/$1
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Add a Boot Option
8VHWKLVRSWLRQWRDGGLWHPVWRWKH(),ERRWPHQX
7KLVRSWLRQGLVSOD\VWKHILOHV\VWHPVWKDWDUHRQ\RXUV\VWHPDQGOHWV\RXEURZVHWKHVHILOH
V\VWHPVIRUDSSOLFDWLRQVRUGULYHUVWKDWDUHH[HFXWDEOH([HFXWDEOHILOHVHQGZLWKWKH.efi
H[WHQVLRQ<RXFDQDOVRVHOHFWUHPRWHERRW/$1RSWLRQVWKDWKDYHEHHQFRQILJXUHGRQ\RXU
QHWZRUN7KHRSWLRQ\RXKDYHVHOHFWHGZLOOEHDGGHGWRWKH(),ERRWPHQX
,I\RXDGGDQHZGULYHWR\RXUV\VWHP\RXPXVWPDQXDOO\DGGLWVERRWRSWLRQVOLVWLI\RXZDQWWR
PDNHLWDERRWDEOHGHYLFH
:KHQDGGLQJDERRWRSWLRQWKDWDOUHDG\H[LVWVLQWKH%RRW0DQDJHUOLVWRIERRWRSWLRQV\RXFDQ
FKRRVHZKHWKHUWRFUHDWHDQHZRSWLRQRUPRGLI\WKHH[LVWLQJRQH,I\RX
■
&KRRVHWRPRGLI\DQH[LVWLQJRSWLRQ\RXPD\FKDQJHWKHERRWRSWLRQQDPHDQGRUDGGERRW
RSWLRQDUJXPHQWVWRWKHH[LVWLQJRSWLRQ
■
&UHDWHDQHZERRWRSWLRQIRUDQDOUHDG\H[LVWLQJRSWLRQPXOWLSOHLQVWDQFHVRIWKHVDPHERRW
RSWLRQH[LVW
)RUH[DPSOH
Add a Boot Option. Select a Volume
NO VOLUME LABEL [Acpi(HWP0002,500)/Pci(2|0)/Ata(Primary,Master)/
Removable Media Boot [Acpi(HWP0002,500)/Pci(2|0)/Ata(Secondary,M
Load File [EFI Shell [Built-in]]
Load File [Acpi(HWP0002,500)/Pci(3|0)/Mac(00306E385AFB)]
Exit
,QWKLVH[DPSOH
■
0RVWRIWKHLWHPVDUHWKHVDPHRSWLRQVLQBoot From a File
■
NO VOLUME LABELLVDKDUGGULYH<RXFDQVHDUFKWKURXJKWKHGLVNIRUERRWDEOH
■
■
DSSOLFDWLRQVWRDGGWRWKH%RRW0DQDJHUOLVWRI%RRWRSWLRQV
Removable Media BootZLOOWUHDWWKH5HPRYDEOH0HGLDJHQHUDOO\D&'DVDERRWDEOH
GHYLFH
Load File EFI ShellDGGVDQHZLQVWDQFHWRWKH(),6KHOO/RDG)LOHZLWKWKH0$&DGGUHVV
DGGVDQHWZRUNERRWRSWLRQ
Delete Boot Option(s)
8VHWKLVRSWLRQWRUHPRYHERRWRSWLRQVIURPWKH(),ERRWPHQX
127(7KLVGRHVQRWGHOHWHDQ\ILOHVDSSOLFDWLRQVRUGULYHUVIURP\RXUV\VWHP
7KLVRSWLRQGLVSOD\VDOLVWRIERRWRSWLRQVWKDWDUHFRQILJXUHGRQ\RXUV\VWHP7KHQDPHVZLOO
PDWFKWKHRSWLRQVRQWKHPDLQ%RRW0DQDJHUPHQXDERYH
,I\RXUHPRYHDGULYHIURP\RXUV\VWHP\RXPXVWPDQXDOO\GHOHWHLWIURPWKHERRWRSWLRQVOLVW
■
7RGHOHWHDQLWHPIURPWKHOLVWXVHWKHDUURZNH\VWRKLJKOLJKWWKHLWHPDQGSUHVVEnter
■
7RUHPRYHDOORIWKHHQWULHVIURPWKH(),ERRWPHQXVHOHFWDelete All Boot Options7KLV
VHWWLQJPD\EHXVHGDVDVHFXULW\GHYLFHRQV\VWHPVWKDWDUHDFFHVVHGUHPRWHO\
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–15
System Configuration
Change Boot Order
8VHWKLVRSWLRQWRFKDQJHWKHRUGHURIERRWRSWLRQV7KHRUGHULQZKLFKRSWLRQVDUHOLVWHGLQWKH
(),ERRWPHQXDOVRUHIOHFWVWKHRUGHULQZKLFKWKHV\VWHPDWWHPSWVWRERRW,IWKHILUVWERRW
RSWLRQIDLOVWKHV\VWHPWULHVERRWLQJWKHVHFRQGWKHQWKHWKLUGDQGVRIRUWKXQWLODERRWRSWLRQ
VXFFHHGVRUXQWLODOORSWLRQVKDYHIDLOHG
)RUH[DPSOHLI\RXQRUPDOO\ERRWXVLQJDFRQILJXUDWLRQRQ\RXU/$1EXWZRXOGOLNHWRERRW
IURPDORFDOKDUGGULYHLIWKH/$1LVXQDYDLODEOHPRYHWKH/$1ERRWRSWLRQWRWKHWRSRIWKH
OLVWIROORZHGE\WKHKDUGGULYHERRWRSWLRQ
7KHPHQXOLVWVERRWRSWLRQVWKDWFXUUHQWO\H[LVWLQWKHPDLQ%RRW0DQDJHUPHQX<RXFDQFKDQJH
WKHSULRULW\RIWKHLWHPVE\PRYLQJWKHPXSRUGRZQLQWKHOLVW
■
3UHVVUWRPRYHDQRSWLRQXS
■
3UHVVDWRPRYHDQRSWLRQGRZQ
■
6HOHFWSave Settings to NVRAMWRPRGLI\WKHRUGHULQWKH%RRW0DQDJHUPHQXZKLFK
PRGLILHVWKHRUGHUWKDWWKH%RRW0DQDJHUZLOODWWHPSWWRERRWWKHRSWLRQV
■
7KHLWHPVDWWKHERWWRPRIWKHVFUHHQVKRZQLQEROGLQWKHVHH[DPSOHVDUHGHVFULSWLRQVRI
WKHVHOHFWHGRSWLRQ
)RUH[DPSOH
Change boot order. Select an Operation
EFI Shell [Built-in]
Current OS
Save Settings to NVRAM
Help
Exit
VenHw(D65A6B8C-71E5-4DF0-A909-F0D2992B5AA9)
Boot0000
3–16
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Manage BootNext Setting
8VHWKLVRSWLRQWRUXQWKHVHOHFWHGERRWRSWLRQLPPHGLDWHO\XSRQHQWHULQJWKHPDLQ%RRW
0DQDJHUPHQX7KLVRSWLRQLVXVHIXOIRUERRWLQJDQRSWLRQWKDWRQO\QHHGVWREHERRWHGRQFH
ZLWKRXWFKDQJLQJDQ\RWKHUVHWWLQJLQWKHPDLQ%RRW0DQDJHUPHQX7KLVLVDRQHWLPHRSHUDWLRQ
DQGGRHVQRWFKDQJHWKHSHUPDQHQWV\VWHPERRWVHWWLQJV
7KLVRSWLRQGLVSOD\VWKHILOHV\VWHPVWKDWDUHRQ\RXUV\VWHPDQGOHWV\RXEURZVHWKHVHILOH
V\VWHPVIRUDSSOLFDWLRQVRUGULYHUVWKDWDUHH[HFXWDEOH([HFXWDEOHILOHVHQGZLWKWKH.efi
H[WHQVLRQ<RXFDQDOVRVHOHFWUHPRWHERRW/$1RSWLRQVWKDWKDYHEHHQFRQILJXUHGRQ\RXU
QHWZRUN
7RUHVWRUHWKHGHIDXOWERRWQH[WVHWWLQJVHOHFWReset BootNext Setting
)RUH[DPSOH
Manage BootNext setting. Select an Operation
EFI Shell [Built-in]
Current OS
Reset BootNext Setting
Save Settings to NVRAM
Help
Exit
VenHw(D65A6B8C-71E5-4DF0-A909-F0D2992B5AA9)
Boot0000
Set Auto Boot TimeOut
8VHWKLVRSWLRQWRVHWWKHDPRXQWRIWLPHWKHV\VWHPSDXVHVEHIRUHDWWHPSWLQJWRODXQFKWKHILUVW
LWHPLQWKH%RRW2SWLRQVOLVW
)RUH[DPSOH
Set Auto Boot Timeout. Select an Option
Set Timeout Value
Delete/Disable Timeout
Help
Exit
,QWHUUXSWLQJWKHWLPHRXWGXULQJWKHFRXQWGRZQVWRSVWKH%RRW0DQDJHUIURPORDGLQJDQ\ERRW
RSWLRQVDXWRPDWLFDOO\,IWKHUHLVQRFRXQWGRZQERRWRSWLRQVPXVWEHVHOHFWHGPDQXDOO\
■
7RVHWWKHDXWRERRWWLPHRXWYDOXHLQVHFRQGVVHOHFWSet Timeout ValueDQGHQWHUWKH
GHVLUHGYDOXH
■
7RGLVDEOHWKHWLPHRXWIXQFWLRQVHOHFWDelete/Disable Timeout
127(:KHQWKLVRSWLRQLVVHOHFWHGWKHV\VWHPGRHVQRWDXWRPDWLFDOO\ERRW7KHV\VWHPVWRSV
DWWKH(),ERRWPHQXDQGZDLWVIRUXVHULQSXW
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–17
System Configuration
Select Active Console Output Devices
8VHWKLVRSWLRQWRGHILQHWKHGHYLFHVWKDWGLVSOD\RXWSXWIURPWKHV\VWHPFRQVROH7KLVOLVW
QRUPDOO\LQFOXGHVWKH9*$PRQLWRUDQGDVHULDOSRUWIRUGLUHFWLQJRXWSXWWRDWHUPLQDOHPXODWLRQ
SDFNDJH
127(,I\RXLQVWDOODPRGHPLQ\RXUV\VWHPPDNHVXUH\RXGLVDEOHWKHPRGHPVHULDOSRUWLQ
ERWKWKH$FWLYH&RQVROH,QSXWDQG$FWLYH&RQVROH2XWSXWGHYLFHOLVWV
127(6RPHRSHUDWLQJV\VWHPVVXSSRUWPXOWLSOHFRQVROHVVXFKDVDVLPXOWDQHRXVVHULDODQG
9*$RXWSXW6HH\RXU26GRFXPHQWDWLRQWRGHWHUPLQHKRZPDQ\FRQVROHVDUHVXSSRUWHG
ZLWK\RXUV\VWHP0XOWLSOHFRQVROHVDUHQRWVXSSRUWHGIRU+38;RU:LQGRZVXVHWKH6PDUW
6HWXS&'WRVZLWFKEHWZHHQ&20$DQGWKH03RQ:LQGRZVV\VWHPV
)RUH[DPSOH
Select the Console Output Device(s)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(PcAnsi)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100)
* Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100+)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(VtUtf8)
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(PcAnsi)
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(Vt100)
* Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(Vt100+)
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(VtUtf8)
Acpi(HWP0002,700)/Pci(2|0)
* Acpi(HWP0003,0)/Pci(0|0)
Save Settings to NVRAM
Exit
LQGLFDWHVDFXUUHQWO\VHOHFWHGGHYLFH
7KLVPHQXLVLGHQWLFDOWRConsole Error Devices7KH][U[GRHVQRWVXSSRUW
GLIIHUHQWFRQILJXUDWLRQVIRU2XWSXWDQG(UURUFRQVROH)RUFRUUHFWRSHUDWLRQ
3–18
■
:KHQFKDQJHVDUHPDGHWRHLWKHU2XWSXWRU(UURUFRQVROHPHQXVWKHLGHQWLFDOFKDQJHPXVW
EHPDGHLQERWKPHQXV
■
:KHQFKDQJLQJVHULDOGHYLFHVFKDQJHVPXVWEHPDGHWR2XWSXW,QSXWDQG(UURUPHQXVIRU
SURSHURSHUDWLRQ
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
To select:
Choose:
Serial A/Serial 1
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100+)
MP Serial Console
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(Vt100+)
MP VGA Port
Acpi(HWP0002,700)/Pci(2|0)
AGP Graphics Port
Acpi(HWP0003,0)/Pci(0|0)
■
(DFKRSWLRQLVLGHQWLILHGZLWKDQ(),GHYLFHSDWK1RWDOORSWLRQVZLOOEHDYDLODEOH
GHSHQGLQJRQWKHFRQILJXUDWLRQRIWKHV\VWHPDQGWKHRSWLRQVSXUFKDVHG'HYLFHSDWKVPD\
GLIIHUVOLJKWO\RQGLIIHUHQWSURGXFWPRGHOV
■
2QERWKVHULDOGHYLFHH[DPSOHV8$57LQGLFDWHVWKHFXUUHQWEDXGUDWHRIWKHVHULDO
GHYLFHFDQEHFKDQJHGZLWKWKH(),VKHOObaudFRPPDQG9HQ0VJ9WLVWKHFXUUHQW
HPXODWLRQW\SHVHYHUDOGLIIHUHQWWHUPLQDOHPXODWLRQSURWRFROVDUHVXSSRUWHGVHHOLVWDERYH
■
2QO\RQHWHUPLQDOHPXODWLRQW\SH3F$QVL9WHWFFDQEHVHOHFWHGIRUHDFKVHULDO
FRQVROHEXWPXOWLSOHVHULDOFRQVROHVFDQEHVHOHFWHGDWDWLPH
■
2QO\RQH9*$JUDSKLFVGHYLFHFDQEHVHOHFWHGDWDWLPH<RXFDQQRWVHOHFWERWKWKH03
9*$SRUWDQGDQ$*3JUDSKLFVFDUG
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–19
System Configuration
Select Active Console Input Devices
8VHWKLVRSWLRQWRGHILQHWKHGHYLFHVWKDWDUHXVHGWRSURYLGHLQSXWWRWKHV\VWHPFRQVROH
7KLVRSWLRQGLVSOD\VWKHFRQVROHGHYLFHVRQ\RXUV\VWHP7KLVQRUPDOO\LQFOXGHVDVWDQGDUG
NH\ERDUGDQGPRXVHDQGDVHULDOSRUWIRUUHFHLYLQJRXWSXWIURPDWHUPLQDOHPXODWLRQSDFNDJHRQ
DODSWRS6HYHUDOGLIIHUHQWWHUPLQDOHPXODWLRQSURWRFROVDUHVXSSRUWHG
■
:KHQFKDQJLQJVHULDOGHYLFHVFKDQJHVPXVWEHPDGHWR2XWSXW,QSXWDQG(UURUPHQXVIRU
SURSHURSHUDWLRQ
127(,I\RXLQVWDOODPRGHPLQ\RXUV\VWHPPDNHVXUH\RXGLVDEOHWKHPRGHPVHULDOSRUWLQ
ERWKWKH$FWLYH&RQVROH,QSXWDQG$FWLYH&RQVROH2XWSXWGHYLFHOLVWV
127(6RPH2SHUDWLQJ6\VWHPVVXSSRUWPXOWLSOHLQSXWGHYLFHVVXFKDVDVLPXOWDQHRXVVHULDO
DQGNH\ERDUGLQSXW6HH\RXU26GRFXPHQWDWLRQWRGHWHUPLQHKRZPDQ\FRQVROHVDUH
VXSSRUWHGZLWK\RXUV\VWHP
)RUH[DPSOH
Select the Console Input Device(s)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(PcAnsi)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100)
* Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100+)
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(VtUtf8)
* Acpi(HWP002,500)/PCI(1|1)/Usb(1,0)
Save Settings to NVRAM
Exit
Active Input Device. Hotplug USB keyboard.
(Deselection feature disabled).
LQGLFDWHVDFXUUHQWO\VHOHFWHGGHYLFH
3–20
■
2QV\VWHPZLWKILUPZDUHYHUVLRQRUKLJKHUWKH86%NH\ERDUGRSWLRQLVDOZD\VDFWLYH
DQGFDQQRWEHGHVHOHFWHGRUGLVDEOHG
■
(DFKRSWLRQLVLGHQWLILHGZLWKDQ(),'HYLFHSDWK1RWDOORSWLRQVZLOOEHDYDLODEOH
GHSHQGLQJRQWKHFRQILJXUDWLRQRIWKHV\VWHPDQGWKHRSWLRQVSXUFKDVHG'HYLFHSDWKVPD\
GLIIHUVOLJKWO\RQGLIIHUHQWSURGXFWPRGHOV
■
2QERWKVHULDOGHYLFHH[DPSOHV8$57LQGLFDWHVWKHFXUUHQWEDXGUDWHRIWKHVHULDO
GHYLFH9HQ0VJ9WLVWKHFXUUHQWHPXODWLRQW\SH6HYHUDOGLIIHUHQWWHUPLQDOHPXODWLRQ
SURWRFROVDUHVXSSRUWHGVHHOLVWDERYH
■
2QO\RQHWHUPLQDOHPXODWLRQW\SHVXFKDV3F$QVLRU9WFDQEHVHOHFWHGIRUHDFKVHULDO
FRQVROHEXWPXOWLSOHVHULDOFRQVROHVFDQEHVHOHFWHGDWDWLPH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
To select:
Choose:
Serial A/Serial 1
Acpi(PNP0501,0)/Uart(9600 N81)/VenMsg(Vt100+)
MP serial console
Acpi(HWP0002,700)/Pci(1|1)/Uart(9600 N81)/VenMsg(Vt100+)
USB keyboard
Acpi(HWP0002,0)/Pci(1|0)
Select Active Standard Error Devices
8VHWKLVRSWLRQWRGHILQHWKHGHYLFHVWKDWGLVSOD\HUURUPHVVDJHVIURPWKHV\VWHPFRQVROH
7KLVPHQXLVLGHQWLFDOWRConsole Output Devices7KH][U[GRHVQRWVXSSRUW
GLIIHUHQWFRQILJXUDWLRQVIRU2XWSXWDQG(UURUFRQVROH)RUFRUUHFWRSHUDWLRQ
■
:KHQFKDQJHVDUHPDGHWRHLWKHU2XWSXWRU(UURUFRQVROHPHQXVWKHLGHQWLFDOFKDQJHPXVW
EHPDGHLQERWKPHQXV
■
:KHQFKDQJLQJVHULDOGHYLFHVFKDQJHVPXVWEHPDGHWR2XWSXW,QSXWDQG(UURUPHQXVIRU
SURSHURSHUDWLRQ
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–21
System Configuration
Using the System Configuration Menu
7KH System Configuration Menu RQV\VWHPVZLWK(),ILUPZDUHYHUVLRQRUKLJKHU
LQFOXGHVWKHIROORZLQJRSWLRQV
7KHSecurity/Password MenuOHWV\RXFKDQJHWKHDGPLQLVWUDWRUDQGXVHUSDVVZRUGV
■ 7KHAdvanced System Information Menu GLVSOD\VLQIRUPDWLRQDERXWV\VWHPDQG
FRPSRQHQWFRQILJXUDWLRQ
■
■
Set System DateOHWV\RXPRGLI\WKHV\VWHPGDWH
■
Set System Time OHWV\RXPRGLI\WKHV\VWHPWLPH
■
Reset Configuration to Default OHWV\RXUHVWRUHV\VWHPVHWWLQJVWRWKHLURULJLQDO
FRQILJXUDWLRQ
■
HelpGLVSOD\VDGGLWLRQDOLQIRUPDWLRQDERXWWKHDYDLODEOHRSWLRQV
■
Exit UHWXUQVWRWKH(),VWDUWXSPHQX
Security/Password Menu
<RXFDQVHWDGPLQLVWUDWRUDQGXVHUSDVVZRUGVWRSURYLGHGLIIHUHQWOHYHOVRIDFFHVVWRWKHV\VWHP
ILUPZDUH
■
7KH$GPLQLVWUDWRUFDQDFFHVVDQGFKDQJHDOOVHWWLQJVLQWKH(),%RRW0DQDJHUSURJUDPDQG
FDQUXQWKH(),VKHOO
■
7KH8VHUFDQDFFHVVEDVLFIXQFWLRQVLQWKH(),%RRW0DQDJHU
127(7KHVHDUHQRW26SDVVZRUGV7KHVHSDVVZRUGVOLPLWDFFHVVWRWKHILUPZDUHLQWHUIDFH
RQO\)RULQIRUPDWLRQRQVHWWLQJ26SDVVZRUGVVHH\RXU26XVHUJXLGH
7RDGGFKDQJHRUGHOHWHSDVVZRUGV
6HOHFW Security/Password Menu
6HOHFWHLWKHU
❏
❏
Set Administrator Options
Set User Options
6HOHFW
❏
Set Administrator Password RUSet User PasswordWRVHWDQHZSDVVZRUG
❏
Enable/disable PasswordWRVSHFLI\ZKHWKHUDSDVVZRUGLVUHTXLUHG
❏
HelpIRUDVVLVWDQFH
4. :KHQ\RXDUHILQLVKHGVHOHFWExit
3–22
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Advanced System Configuration Menu
7KHAdvanced System Configuration MenuFDQGLVSOD\DYDULHW\RILQIRUPDWLRQDERXW
\RXUV\VWHPFRQILJXUDWLRQ7KHIROORZLQJH[DPSOHVVKRZW\SLFDOFRQILJXUDWLRQVWKHH[DFW
LQIRUPDWLRQRQHDFKV\VWHPLVGLIIHUHQW
■
All x Information
7KLVRSWLRQVOLVWVDOORIWKHLQIRUPDWLRQIURPWKHVHOHFWLRQVEHORZLQRQHVFUHHQ
■
System Information
Date/Time: May 14, 2003 13:00:43 (20:03:05:14:13:00:43)
Manufacturer: hp
Product Name: workstation zx6000
Product Number: A8081A
Serial Number: TS21600014
UUID: 31619E41-2DD2-11D7-BC2F-0735A1DF6599
System Bus Frequency: 200 MHz
■
Processor Information
# of L3 L4 Family/
CPU Logical Cache Cache Model Processor
Slot CPUs Speed Size
Size (hex.)
Rev State
---- ------- -------- ------ ------ ------- --- -----------0 1
900 MHz 1.5 MB None 1F/00
B3 Active
■
Cache Information
6HH3URFHVVRU,QIRUPDWLRQDERYH
■
Memory Information
---- DIMM A ----- ---- DIMM B ----DIMM Current DIMM Current
--- ------ ---------- ------ ---------0 256MB Active 256MB Active
1 256MB Active 256MB Active
Active Memory : 1024 MB
Installed Memory : 1024 MB
■
Bootable Devices Information
Order Media Type Path
----- ---------- --------------------------------------1 HARDDRIVE Acpi(HWP0002,500)/Pci(2|0)/Ata(Primary...
2 CDROM Acpi(HWP0002,500)/Pci(2|0)/Ata(Secondary...
Seg Bus Dev Fnc Vendor Device Slot
# # # # ID ID # Path
--- --- --- --- ------ ------ --- ----------00 A0 01 00 0x1033 0x0035 XX Acpi(HWP0002,500)/Pci(1|0)
00 A0 01 01 0x1033 0x0035 XX Acpi(HWP0002,500)/Pci(1|1)
00 A0 01 02 0x1033 0x00E0 XX Acpi(HWP0002,500)/Pci(1|2)
00 A0 02 00 0x1095 0x0649 XX Acpi(HWP0002,500)/Pci(2|0)
00 A0 03 00 0x8086 0x100E XX Acpi(HWP0002,500)/Pci(3|0)
00 A0 04 00 0x1319 0x0801 XX Acpi(HWP0002,500)/Pci(4|0)
00 A0 04 01 0x1319 0x0802 XX Acpi(HWP0002,500)/Pci(4|1)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–23
System Configuration
■
Boot Information
Monarch CPU:
Current Preferred
Monarch Monarch Possible Warnings
------- --------- ----------------0 0
AutoBoot: ON - Timeout is : 7 sec
Boottest:
BOOTTEST Settings Default Variable
OS is not speedy boot aware.
Selftest Setting
--------- -------------early_cpu Run this test
late_cpu Run this test
platform Run this test
chipset Run this test
io_hw Run this test
mem_init Run this test
mem_test Run this test
LAN Address Information:
LAN Address Path
----------------- ---------------------------------------*Mac(00306E385AFB) Acpi(HWP0002,500)/Pci(3|0)/Mac(00306E385AFB))
■
Firmware Information
Firmware Revision: 2.00 [4320]
PAL_A Revision: 7.31/7.31
PAL_B Revision: 7.40
SAL Spec Revision: 3.01
SAL_A Revision: 2.00
SAL_B Revision: 2.00
EFI Spec Revision: 1.10
EFI Intel Drop Revision: 14.61
EFI Build Revision: 1.22
POSSE Revision: 0.10
ACPI Revision: 7.00
BMC Revision 1.50
IPMI Revision: 1.00
SMBIOS Revision: 2.3.2a
Management Processor Revision:
■
Warning and Stop Boot Information
%ODQNXQOHVVV\VWHPIDXOWVKDYHEHHQLGHQWLILHG6HH&KDSWHU¦7URXEOHVKRRWLQJ§
■
Chip Revision Information
Chip Logical Device Chip
Type ID ID Revision
------------------- ------- ------ -------Memory Controller 0 122b 0023
Root Bridge 0 1229 0023
Host Bridge 0000 122e 0032
Host Bridge 0004 122e 0032
Host Bridge 0005 122e 0032
Host Bridge 0006 122e 0032
Other Bridge 0 0 0002
Other Bridge 0 0 0007
Baseboard MC 0 0 0150
3–24
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Using the Security/Password Menu
7KHSecurity/Password MenuRQV\VWHPVZLWK(),ILUPZDUHYHUVLRQRUORZHULV
LGHQWLFDOWRWKHVHFXULW\SDVVZRUGVXEPHQXRIWKHSystem Configuration Menu6HH
SDJH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–25
System Configuration
Resetting Passwords
,I\RXIRUJHWDSDVVZRUG\RXFDQUHVHWLWZLWKDQ03FRPPDQG)ROORZWKHVHVVWHSV
■
,I\RXUV\VWHPKDVDQ03FDUG
5XQWKH03FDUGbpFRPPDQGWRUHVHWWKHDGPLQLVWUDWRUDQGXVHUSDVVZRUGVVHH¦8VLQJWKH
03&RPPDQGV²SDJH
■
,I\RXUV\VWHPGRHVQRWKDYHDQ03FDUG\RXPXVWUHVHWWKHSDVVZRUGVXVLQJDMXPSHURQ
WKHV\VWHPERDUG
D 3RZHUGRZQWKHV\VWHPDQGXQSOXJWKH$&SRZHUFRUG
E 3ODFHDMXPSHUEHWZHHQSLQVDQGRQ-RQWKHV\VWHPERDUGEHKLQGWKHEDWWHU\
7
8
Password Reset Jumper
F 3OXJLQWKH$&SRZHUFRUGDQGZDLWIRUWKH%0&KHDUWEHDW/('RQWKHV\VWHPERDUGWR
VWDUWEOLQNLQJJUHHQ7KLVVKRXOGWDNHDERXWVHFRQGVIURPWKHWLPH\RXSOXJLQWKH
SRZHUFRUG
G 8QSOXJWKH$&SRZHUFRUGDJDLQDQGUHPRYHWKHMXPSHU
H 3OXJLQWKHSRZHUFRUGDQGERRWWKHV\VWHP
I
7KHSDVVZRUGVKDYHEHHQFOHDUHG)ROORZWKHLQVWUXFWLRQVDERYHWRVHWQHZV\VWHP
SDVVZRUGV
J 6WRUHWKHV\VWHPLQDVHFXUHORFDWLRQDQGNHHSWKHV\VWHPFDVHORFNHGDWDOOWLPHVWR
SURWHFWDJDLQVWXQDXWKRUL]HGDFFHVV
3–26
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Management Processor (MP)
7KH0DQDJHPHQW3URFHVVRU03FDUGFRQWDLQVDSURFHVVRUDQG,2KDUGZDUHWKDWDFWDVDQ
DXWRQRPRXVHPEHGGHGGHYLFHIRUFRQWUROOLQJWKHV\VWHPFRQVROHUHVHWDQGSRZHUPDQDJHPHQW
IXQFWLRQV
127(7KLVVHFWLRQDVVXPHVWKDWWKH03FDUGLVLQVWDOOHGLQ\RXUV\VWHP7RGHWHUPLQHLIWKH
FDUGLVLQVWDOOHGORRNDWWKHEDFNSDQHORI\RXUV\VWHP<RXZLOOVHHDSLQVHULDOSRUWLIWKH03
FDUGLVLQVWDOOHG
7ZRPDMRUIXQFWLRQVRIWKH03FDUGDUHUHPRWHDQGORFDOPDQDJHDELOLW\7KH03FDUGFRQWDLQV
WKHPDQDJHPHQWSURFHVVRU03ZKLFKPRQLWRUVV\VWHPVWDWXVDQGFDQFRQWUROYDULRXVDVSHFWV
RIWKHV\VWHPRSHUDWLRQVXFKDVSRZHUUHVHWVVRIWZDUHILUPZDUHXSJUDGHVDQGFRROLQJ7KH03
FDUGPDQDJHDELOLW\KDUGZDUHRSHUDWHVRQVWDQGE\SRZHULQGHSHQGHQWO\RIWKHRQRIIVWDWHRIWKH
UHVWRIWKHV\VWHP
7KH03XVHVWKHIROORZLQJH[WHUQDOPHPRU\0%'5$00%)ODVKDQG.%RI
195$0$SRZHUPRQLWRUDQGZDWFKGRJWLPHUUHVHWWKHSURFHVVRULIVWDQGE\SRZHULVRXWRI
VSHFLILFDWLRQRUWKHSURFHVVRULVLQDFWLYHIRUDVHWDPRXQWRIWLPH7KHSURFHVVRUDOVRXVHVD
0+]FORFN
7KH,2DQGPHPRU\FRQWUROOHUFKLSLVFRQQHFWHGWRWKH03FDUG©V,2EXVLQWHUIDFHE\URSH
QXPEHUVHYHQRIWKHV\VWHPEXV7KH03FDUGFRQVLVWVRIWKHIROORZLQJFRPSRQHQWV
■
,2EXVLQWHUIDFH
■
9*$FRQWUROOHUZLWK0%RI''56'5$0IRUDYLGHREXIIHU
■
0DQDJHPHQW3URFHVVRUZLWK
❏
7KUHH56VHULDOSRUWV
❏
)RXU,&SRUWV
❏
%7/$1
❏
ELW*3,2LQWHUIDFH
■
0DQDJHPHQW3URFHVVRU'5$0IODVKPHPRU\DQGEDWWHU\EDFNHG1965$0
■
,&EDWWHU\EDFNHGUHDOWLPHFORFN
■
,&ILHOGUHSODFHDEOHXQLW((3520
■
,&.VHULDO((3520
■
6\VWHPUHVHWORJLF
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–27
System Configuration
MP Card I/O Functionality
7KH03FDUGLQFOXGHVWKHVH,2FRPSRQHQWV
■
6\VWHPVHULDOSRUWV
❏
7KUHH56SRUWVFDQEHDFFHVVHGWKURXJKRQHWKUHHFRQQHFWRUFDEOH$
GRQJOHZKHQWKLVFDEOHLVFRQQHFWHGWRWKH'%FRQQHFWRUORFDWHGRQWKHEDFNSODQHRI
WKHV\VWHP7KLVFDEOHSURYLGHVIRUWKUHH'%FRQQHFWRUVIRUFRQVROHPRGHPDQG836
❏
7KH03FDUGVHULDOSRUWVFDQEHFRQILJXUHGWRUHGLUHFWV\VWHPFRQVROHDQGVHVVLRQ
FRPPXQLFDWLRQVWRWKH56OLQHVORFDOSRUWDQGDPRGHPUHPRWHSRUW
■
9*$FRQWUROOHU7KH'9*$JUDSKLFVFRQWUROOHUFRQVROHSRUWLVSURYLGHGRQD'%)
FRQQHFWRU$OVR6HULDO)ODVKPHPRU\ZLWK9*$%,26DQGD0%YLGHREXIIHU''5
6'5$0LVLQFOXGHGZLWKWKH9*$FRQWUROOHU
■
3&,LQWHUIDFH7KH3&,LQWHUIDFHFRQQHFWVWKH3&,EXVZLWKWKH037KLVLQWHUIDFHHPXODWHV
WKUHHVW\OH8$57VDQGSDUWRIWKH03FDUG
■
,&EXV7KH,&EXVRIWKH03SURYLGHVFRPPXQLFDWLRQZLWKWKH%0&
■
6HUYLFH/$11HWZRUNDFFHVVLVSURYLGHGE\D%7/$1FRQQHFWLRQRQD5-
FRQQHFWRUDQGLWVDVVRFLDWHG/('VZKLFKDUHORFDWHGRQWKH03FDUG$Q,&.VHULDO
((3520VXSSRUWV0$&DGGUHVVVWRUDJH
127(7KH03FDUGFDQEHLQVWDOOHGRQV\VWHPVZLWKRUZLWKRXWDQ$*3JUDSKLFVFDUG,IDQ
$*3JUDSKLFVFDUGLVQRWLQVWDOOHGWKH03FDUG9*$SRUWVHUYHVDVWKH(),FRQVROHDQGWKH26
PRQLWRU,IDQ$*3JUDSKLFVFDUGLVLQVWDOOHGWKH$*3JUDSKLFVFDUGVHUYHVDVWKH(),FRQVROH
DQGWKH26PRQLWRU
3–28
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Accessing the MP
<RXFDQDFFHVVWKH03FDUGDQGHQWHU03FRPPDQGVE\
■
6HULDOFRQVROHSRUW
■
/$1FRQQHFWLRQ
■
0RGHPFRQQHFWHGWR56SRUW
127(7KH03VFUHHQVDQGFRPPDQGVYDU\GHSHQGLQJRQWKH03ILUPZDUHYHUVLRQLQVWDOOHGRQ
\RXUV\VWHP7KH03ILUPZDUHUHYLVLRQQXPEHULVOLVWHGRQWKH03ORJLQVFUHHQ0DNHQRWHRI
WKHYHUVLRQQXPEHUEHIRUHSURFHHGLQJ
HP Management Processor
Firmware Revision E.02.10 Oct 1 2002,10:28:32
(c) Copyright Hewlett-Packard Company 1999-2002. All Rights Reserved.
)RULQIRUPDWLRQRQXSGDWLQJ\RXUILUPZDUHVHH¦)LUPZDUHXSJUDGHV²SDJH
Accessing the MP Using the Serial Console Port
7RHQWHU03FRPPDQGPRGHXVLQJWKH6HULDO&RQVROH3RUW
&RQQHFWWKHV\VWHPWRDUHPRYHGHYLFH
D &RQQHFWWKHSLQHQGRIDVHULDOFDEOHWRWKH03FDUGSLQ6HULDO3RUWRQWKHUHDU
SDQHORIWKHV\VWHP
E &RQQHFWWKHFRQVROHFRQQHFWRURQWKHVHULDOFDEOHWR\RXUUHPRWHGHYLFH
&RQILJXUHWKHWHUPLQDOHPXODWLRQVRIWZDUHZLWKWKHVHVHWWLQJV
❏
7HUPLQDOHPXODWLRQ97
❏
%DXGUDWH
127(7KH(),baudFRPPDQGGRHVQRWFKDQJHWKH03FDUGVHULDOSRUWVSHHG
❏
%LWV
❏
3DULW\1RQH
❏
6WRS%LWVRQH
❏
)ORZ&RQWURO1RQH
8VLQJWKHWHUPLQDOHPXODWLRQVRIWZDUHFRQQHFWWRWKHV\VWHPZLWKDGLUHFWFRQQHFWLRQ
3OXJLQWKHV\VWHP'RQRWWXUQLWRQ:DLWIRUWKH03ORJLQWRGLVSOD\RQWKHWHUPLQDOVFUHHQ
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–29
System Configuration
Accessing the MP Using the MP LAN Port
,I\RXKDYHQRWDOUHDG\FRQILJXUHG\RXU03/$1SRUWGRVRQRZ
8VLQJDWHOQHWFOLHQWORJRQWRWKHV\VWHPZLWKWKHKRVWQDPHSURYLGHGE\\RXUQHWZRUN
DGPLQLVWUDWRU
127($OO,3DGGUHVVHVDQGKRVWQDPHVVKRXOGEHSURYLGHGE\\RXUQHWZRUNDGPLQLVWUDWRU
)RUH[DPSOH
C:\> telnet MP_Hostname
:DLWIRUWKH03ORJLQWRGLVSOD\RQWKHWHOQHWVFUHHQ
Configuring the MP LAN Port
%HIRUH\RXFDQH[HFXWH03FRPPDQGVYLD/$1FRQQHFWLRQ\RXPXVWFRQILJXUHWKH/$1
VHWWLQJVRQWKH03FDUGXVLQJD6HULDO&RQVROH3RUWFRQQHFWLRQ
(QWHU03FRPPDQGPRGHXVLQJD6HULDO&RQVROH3RUWSDJH
([HFXWHWKH/$1FRQILJXUDWLRQLCFRPPDQG7KH/$1&RQILJXUDWLRQVFUHHQIRU\RXU
V\VWHP©V03ILUPZDUHUHYLVLRQGLVSOD\V
❏
03ILUPZDUH(¥WKHVFUHHQLQFOXGHVDVXPPDU\RI\RXUFXUUHQW/$1VHWWLQJV
DQGDSURPSW
LC
This command allows you
Current configuration:
IP Address
MP Host Name
Subnet Mask
Gateway
Web Console Port Number
to modify the LAN configuration.
:
:
:
:
:
127.0.0.0
myhost
200.0.0.0
127.0.1.0
2023
Do you want to modify the LAN configuration? (Y/[N])
❏
03ILUPZDUH(RUKLJKHU¥WKHVFUHHQFRQWDLQVDPHQXLQFOXGLQJ\RXUFXUUHQW
/$1FRQILJXUDWLRQVHWWLQJV
LC
At each prompt you may type DEFAULT to set default configuration
or Q to Quit
Current LAN Configuration:
-- MAC Address
: 0x00306e1ee0dd
I - IP Address
: 127.0.0.0
H - MP Host Name
: uninitialized
M - Subnet Mask
: 255.255.255.0
G - Gateway Address
:
L - Link State
: Auto Negotiate
W - Web Console Port Number : 2023
Enter Parameter(s) to change, A to modify All, or [Q] to Quit:
3–30
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
2. Follow the prompts on the screen to modify the LAN settings:
❏
IP Address
❏
MP Host name
❏
Subnet, Gateway
❏
Web Console Port Number
❏
LAN hardware configuration (optional)
The Link State controls the speed at which the MP card communicates with the network.
◆
Select auto-negotiate to allow the system to make the fastest possible connection.
The MP card will also negotiate to half or full duplex. This is the default,
recommended in most cases.
◆
Select 10BaseT to force the MP card to operate at the slower 10BaseT speed if
necessary for your network configuration. For example, if your network contains
both 10BaseT and 100BaseT connections, and you want the system to communicate
with the other 10BaseT connections, you must force it to operate at the slower speed.
NOTE: If you force the MP card to operate at 10BaseT speed, it also operates at half duplex.
Make sure that your switch or hub is also in half duplex mode.
In all options, to:
❏
Change the setting, type the appropriate information, then press Enter.
❏
Confirm your selections, type Y then press Enter at the confirmation prompt.
3. Execute the xd command to reset the MP card. The following is displayed, depending on
your system’s MP firware revision.
❏
MP firmware E.02.10:
xd
Non destructive tests:
1. Parameters checksum
2. I2C access (get Power Monitor status)
3. LAN access (PING)
4. Modem selftests
5. Secondary I2C access (get System status)
Type R to reset the MP or [Q] to quit the diagnostic menu.
-> Choice:
❏
MP firmware E.02.20 or higher:
XD
Diagnostics Menu:
Non destructive tests:
P - Parameter checksum
I - I2C access (get Power Monitor Status)
L - LAN access (PING)
M - Modem selftests
Destructive tests:
R - Restart the MP
Enter menu item or [Q] to Quit:
4. Select option 3 or L to ping the LAN and verify the LAN settings are correctly configured.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–31
System Configuration
7\SHRDQGSUHVVEnterWRUHVHWWKH03FDUG,ISURPSWHGW\SHYDQGSUHVVEnterWR
FRQILUPWKHUHVHW
:DLWIRUWKHVWDWXVPHVVDJHWRFOHDU
The MP is now being reset...
&ORVH\RXUWHUPLQDOHPXODWLRQSURJUDP<RXFDQQRZWHOQHWWRWKLVV\VWHPIURPDQRWKHU
UHPRWHV\VWHP
Accessing the MP Using a Modem
127(7RHQDEOHRUGLVDEOHWKHPRGHPSRUWRUJLYHVZLWFKPRGHPFRQWUROEHWZHHQWKH03DQG
WKH26
■ 03ILUPZDUH(¥XVHWKHERFRPPDQG
■ 03ILUPZDUH(RUKLJKHU¥XVHWKHSAFRPPDQG
7RHQWHU03FRPPDQGPRGHXVLQJDPRGHP
/RJLQWRWKH03XVLQJDVHULDORU/$1FRQQHFWLRQDQGFRQILJXUHWKHPRGHPXVLQJWKHCA
FRPPDQGSDJH
❏
%DXGUDWHV,QSXWDQGRXWSXWGDWDUDWHVDUHWKHVDPH
❏
)ORZFRQWURO+DUGZDUHXVHV576&766RIWZDUHXVHV;RQ;RII
❏
7HUPLQDOW\SH+3WHUP
❏
7UDQVPLWFRQILJXUDWLRQVWULQJV'LVDEOHWKLVVHWWLQJZKHQHYHUWKHPRGHPEHLQJXVHGLV
QRWFRPSDWLEOHZLWKWKHVXSSRUWHGPRGHP
❏
0RGHPSUHVHQFH:KHQWKHPRGHPPD\QRWDOZD\VEHFRQQHFWHGVHWWKLVSDUDPHWHUWR
QRWDOZD\VFRQQHFWHG)RUH[DPSOH$PRGHPDWWDFKHGWKURXJKDVZLWFK,QWKLVPRGH
QRGLDORXWIXQFWLRQVDUHDOORZHGDQGSDJLQJLVQRWSRVVLEOH
❏
0RGHPSURWRFRO&&,77LVD(XURSHDQVWDQGDUG576&76VLJQDOLQJLVXVHGDVZHOODV
WKH5LQJVLJQDO%HOOLVD86RUVLPSOHPRGH
&RQILJXUHWKHPRGHPDQGGLDOXSVRIWZDUHRQ\RXUUHPRWHFRPSXWHUWRPDWFKWKHVHWWLQJV
RQWKHU[DQG][03FDUG
'LDOLQXVLQJWKHSURFHGXUHVUHTXLUHGE\\RXUGLDOXSVRIWZDUH
:DLWIRUWKH03ORJLQWRGLVSOD\RQWKHVFUHHQ
3–32
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Logging In to the MP Card Interface
$FFHVVWKH03ORJLQVFUHHQDQGWDNHQRWHRIWKHILUPZDUHYHUVLRQQXPEHUOLVWHG
❏
03ILUPZDUH(¥SUHVVCtrl-BWRDFFHVVWKH03ORJLQVFUHHQ
HP Management Processor
Firmware Revision E.02.10 Oct 1 2002,10:28:32
(c) Copyright Hewlett-Packard Company 1999-2002. All Rights Reserved.
Type Ctrl-B to activate the MP Command Interface
❏
03ILUPZDUH(RUKLJKHU¥WKH03FDUGERRWVGLUHFWO\WRWKH03FRPPDQGPRGH
ORJLQVFUHHQ
HP Management Processor
Firmware Revision E.02.20 May 12 2003,12:26:25
(c) Copyright Hewlett-Packard Company 1999-2003. All Rights Reserved.
MP login:
127(7RVZLWFKEHWZHHQWKH03FDUGDQG(),FRQVROHZLWK03ILUPZDUH(RUKLJKHU
■ ,I\RXDUHDWWKH(),FRQVROHSUHVVCtrl-BWRDFFHVVWKH03ORJLQVFUHHQ
■ ,I\RXDUHDWWKH03FRPPDQGSURPSWH[HFXWHWKHCOFRPPDQGWRHQWHU(),FRQVROH
PRGH
/RJLQ7KHORJLQRSWLRQVGHSHQGRQ\RXU03ILUPZDUHUHYLVLRQ
❏
03ILUPZDUH(¥WKHUHDUHQRGHIDXOW03XVHUV,I\RXKDYHQRW\HWFUHDWHG03
XVHUVSUHVVEnterDWWKHORJLQDQGSDVVZRUGSURPSWVIRULQLWLDODFFHVV
❏
03ILUPZDUH(RUKLJKHU¥WZRGHIDXOWXVHUVH[LVW
◆
$GPLQLVWUDWRUORJLQAdminSDVVZRUGAdmin
◆
2SHUDWRUORJLQOperSDVVZRUGOper
,I\RXKDYHQRW\HWFUHDWHG03XVHUVHQWHUDGHIDXOW,'DQGSDVVZRUGDWWKHORJLQDQG
SDVVZRUGSURPSWVDQGSUHVVEnter IRULQLWLDODFFHVV
HP Management Processor
Firmware Revision E.02.11 Feb 14 2003,9:38:32
(c) Copyright Hewlett-Packard Company 1999-2001. All Rights Reserved
MP login:
MP password:
127(7RHQVXUHV\VWHPVHFXULW\WKHV\VWHPDGPLQLVWUDWRUVKRXOGGRRQHRIWKHIROORZLQJ
■ 'LVDEOHDOOUHPRWHDFFHVVWRWKH03LQFOXGLQJWHOQHWZHEDQGUHPRWHPRGHPDFFHVV
XVLQJWKHsaFRPPDQGSDJHRUXVHWKHUCFRPPDQGWRFRQILJXUH03XVHUV
❏
03ILUPZDUH(¥$GGDXVHUZLWKDXQLTXHSDVVZRUGRQV\VWHPV
❏
03ILUPZDUH(RUKLJKHU¥$GGDXVHUZLWKDXQLTXHSDVVZRUGRQV\VWHPVDQG
GHOHWHWKHGHIDXOWXVHUV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–33
System Configuration
7KHFRPPDQGSURPSWRUPHQXGLVSOD\VGHSHQGLQJRQ\RXU03ILUPZDUHUHYLVLRQ
❏
03ILUPZDUH(¥WKH03FRPPDQGPRGHSURPSWGLVSOD\V
HP Management Processor
Firmware Revision E.02.10 Oct 1 2002,10:28:32
(c) Copyright Hewlett-Packard Company 1999-2002.
All Rights Reserved.
System Name: fstl3a
******************************************************************
MP ACCESS IS NOT SECURE
MP users are currently configured and remote access is enabled.
Set up a user with a password (see SO command)
OR
Disable all types of remote access (see EL and ER commands)
************************************************************
MP Host Name: fstl3a
MP>
❏
03ILUPZDUH(RUKLJKHUWKHPDLQPHQXGLVSOD\V
Hewlett-Packard Management Processor
(c) Copyright Hewlett-Packard Company 1999-2002.
All Rights Reserved.
MP Host Name: iaslhpfc
Revision E.02.11
**************************************************************
MP ACCESS IS NOT SECURE
Default MP users are currently configured and
remote access is enabled.
Modify default users passwords or delete
default users (see UC command)
OR
Disable all types of remote access (see SA command)
**************************************************************
MP MAIN MENU:
CO: Consoles
VFP: Virtual Front Panel
CM: Command Menu
CL: Console Logs
SL: Show Event Logs
CSP: Connect to Service Processor
SE: Create Local Session
HE: Main Help Menu
X: Exit Connection
MP Host Name: iaslhpfc
MP>
3–34
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
<RXFDQQRZHQWHULQGLYLGXDOFRPPDQGV
❏
7RUXQDQLQGLYLGXDOFRPPDQGRQV\VWHPVZLWK03ILUPZDUH(
D 7\SHWKHFRPPDQGDWWKH03FRPPDQGSURPSW
E 3UHVVEnterWRH[HFXWHWKHFRPPDQG
❏
7RUXQDQLQGLYLGXDOFRPPDQGRQV\VWHPVZLWK03ILUPZDUH(RUKLJKHU
D ([HFXWHWKH03CMFRPPDQGWRDFFHVVWKHFRPPDQGPHQXSURPSW
E 7\SHWKHFRPPDQGDWWKHSURPSW
F 3UHVVEnterWRH[HFXWHWKHFRPPDQG
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–35
System Configuration
Using the MP Commands
7KHIROORZLQJVHFWLRQVSURYLGHDEULHIRYHUYLHZRIWKHDYDLODEOHFRPPDQGV)RUGHWDLOHG
LQIRUPDWLRQH[HFXWHWKH03+HOSFRPPDQGhe
7KH03+HOSPHQXGLVSOD\V
==== MP Help ======================================================
MP Help System
Enter a command at the help prompt:
OVerview : Launch the help overview
LIst
: Show the list of MP commands
<COMMAND>
: Enter the command name for help on individual
command
TOPics
: Show all MP Help topics and commands
HElp
: Display this screen
Q
: Quit help
====
MP HELP: <selection>
(QWHUDFRPPDQGQDPHIRUV\QWD[DQGRSWLRQVIRUWKDWFRPPDQG
Executing Commands from Menus
7RH[HFXWHFRPPDQGVIURPWKH03PHQXV
7\SHWKHOHWWHUGHVLJQDWLQJWKHFRPPDQGRQWKHPHQXWKHQSUHVVEnter
)ROORZWKHSURPSWVRQWKHVFUHHQWRFRPSOHWHWKHFRPPDQG
)RUH[DPSOHKHUHLVWKHPHQXIRUWKH/$1&RQILJXUDWLRQlcFRPPDQG
LC
At each prompt you may type
Q to Quit
Current LAN Configuration:
-- MAC Address
I - IP Address
H - MP Host Name
M - Subnet Mask
G - Gateway Address
L - Link State
W - Web Console Port Number
DEFAULT to set default configuration or
:
:
:
:
:
:
:
0x00306e1ee0dd
127.0.0.0
uninitialized
255.255.255.0
Auto Negotiate
2023
Enter Parameter(s) to change, A to modify All, or [Q] to Quit:
Executing Commands from the Command Line
7RH[HFXWHDFRPPDQGIURPWKHFRPPDQGOLQH
(QWHUWKHFRPPDQGDQGDQ\SDUDPHWHUVDWWKHSURPSW)RUH[DPSOH
MP> MPcommand -parameter1 value1 -parameter2 value2 ... [-nc]
3UHVVEnterWRH[HFXWHWKHFRPPDQG
3–36
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Command Syntax
7KH03FRPPDQGV\QWD[LV81,;VW\OHWKDWLVHDFKSDUDPHWHUVWDUWVZLWK-)RUH[DPSOH
■
-ncQRFRQILUPDWLRQLVRSWLRQDO,I-ncLVLQFOXGHGDWWKHHQGRIWKHFRPPDQGOLQHWKH
FRPPDQGLVH[HFXWHGZLWKRXWDVNLQJIRUFRQILUPDWLRQ,I-ncLVQRWLQFOXGHGDFRQILUPDWLRQ
SURPSWLVGLVSOD\HG
■
-?03FRPPDQGVSHFLILFKHOSLVRSWLRQDO,I\RXW\SH-?E\LWVHOIZLWKWKHFRPPDQGKHOS
RQWKHFRPPDQGGLVSOD\V,I\RXXVHWKHFRPPDQGLQFRUUHFWO\WKHKHOSGLVSOD\VLQDGGLWLRQ
WRDQHUURUPHVVDJH
7RVHWWKHGHIDXOWYDOXHRIDSDUDPHWHUDSUHGHILQHGYDOXHLVXVHG7KLVLVWKHZRUGDEFAULT
■
7RVHWDOOSDUDPHWHUVWRWKHLUGHIDXOWYDOXHDVSHFLDOSDUDPHWHU-allLVXVHG)RUH[DPSOH
MPcommand -all DEFAULT
■
)RUPXOWLOHYHOFRPPDQGVZLWKVXEPHQXV\RXFDQVHWDVSHFLILFOHYHOWRWKHGHIDXOWYDOXHV
<RXPXVWDOUHDG\EHIDPLOLDUZLWKWKHRSHUDWLRQRIWKHFRPPDQGVDQGNQRZWKHOHYHO\RX
ZLVKWRVNSWR)RUH[DPSOH
MPcommand -level DEFAULT
ZKHUH-level LVWKHQXPEHURIWKHOHYHO\RXZLVKWRUHVHW
7RGHWHUPLQHLIDJLYHQFRPPDQGLVPXOWLOHYHOHLWKHU
❏
H[HFXWHLWIURPDFRPPDQGPHQXLQWHUIDFHRU
❏
UHYLHZWKHFRPPDQGOLQHKHOSIRUWKDWFRPPDQG
2QHH[DPSOHRIDPXOWLOHYHOFRPPDQGLVWKHCAVHULDOSRUWFRQILJXUDWLRQFRPPDQG
MP:CM> ca
This command allows you to modify the local and remote modem serial
port configurations. Note that terminal type is set simultaneously
for all ports. At each prompt you may type DEFAULT to set default
configuration or Q to Quit
Local and Remote Serial Port Configuration Menu:
D - Display Local/Remote Serial Port Configuration
L - Modify Local Serial Port Configuration
R - Modify Remote/Modem Serial Port Configuration
T - Modify Terminal type
Enter menu item or [Q] to Quit: q
MP Host Name: gstlhpd6
MP:CM> ca -r default
New Remote/Modem Serial Port Configuration (* modified values):
* Bit Rate in bits/sec
: 19200
* Flow Control
: Software
* Modem Presence
: Always connected
* Modem Protocol
: CCITT
* Transmit Configuration Strings : Enabled
Confirm? (Y/[N]):
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–37
System Configuration
,QWKLVFRPPDQGCAWRVHW
■
◆
DOOSDUDPHWHUVWRWKHGHIDXOWVHWWLQJVH[HFXWHCA -all default
◆
DVSHFLILFOHYHOVXFKDVUHPRWHRUORFDOSRUWFRQILJXUDWLRQWRWKHGHIDXOWH[HFXWH
CA -remote defaultRUCA -local default
<RXDOVRFDQVHWVRPHSDUDPHWHUVWRGHIDXOWVDQGRWKHUVWRVSHFLILHGYDOXHV)RUH[DPSOH
MPcommand -parameter1 value -parameter2 DEFAULT
Command Descriptions
Main Menu Commands
0DLQ0HQXFRPPDQGVDUHH[HFXWHGIURP
❏
the MP command prompt with03ILUPZDUH(
❏
WKH0DLQ0HQXSURPSWRIWKH03LQWHUIDFHZLWK03ILUPZDUH(RUKLJKHU
Command
Description
CO
Consoles
VFP
Virtual Front Panel
CM
Command Menu
CL
Console Logs
CSP
Connect to Service Processor (local/remote ports only)
SE
OS Session (local/remote ports only)
SL
Show Event Logs
HE
MP Help Menu
X
Exit MP Interface
Command Categories
7KHUHDUHVL[FDWHJRULHVRI03FRPPDQGV
■
ST¥6WDWXVFRPPDQGV
■
SC¥6HUYHUFRQWUROFRPPDQGV
■
C¥*HQHUDO03FRQILJXUDWLRQFRPPDQGV
■
P¥03SRUWFRQILJXUDWLRQFRPPDQGV
■
Cx¥&RQQHFWLRQVFRPPDQGV
7KHFRPPDQGVLQWKHVHFDWHJRULHVDUHGHVFULEHGLQWKHIROORZLQJVHFWLRQV
3–38
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Status Commands
6WDWXVFRPPDQGVSURYLGHVWDWXVRQWKHV\VWHPDQGRQWKH03FDUG
Command
Description
DATE
Display date
DF
Display field replaceable unit information
LS
LAN status
MS
Status of the modem
PS
Power management module status
SR or SYSREV
Display all firmware revisions
SS
System’s processor status
Server Control Commands
7KHVHFRPPDQGVDOWHUWKHVWDWHRIWKHVHUYHU
Command
Description
BP
Reset BMP passwords
LOC
Locator LED status
MR
Modem reset
PC
Remote power control
PR
Power restore policy configuration
RB
Reset BMC
RS
System reset from RST signal
TC
Transfer of control; system reset through INIT signal
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–39
System Configuration
General MP Configuration Commands
7KHVHFRPPDQGVDOORZ\RXWRSHUIRUPJHQHUDOFRQILJXUDWLRQWDVNVVXFKDVFRQILJXULQJ
DXWRPDWLFV\VWHPUHVWDUWDQGVHWWLQJWKHGHIDXOWFRQILJXUDWLRQ
Command
Description
CG
Generate RSA key pair of self-signed certificate
DC
Default configuration
FW
Upgrade the MP firmware
ID
System identification
IT
Inactivity timeout settings
SO
Configure security options
UC
User configuration
XD
Diagnostics or reset of MP
MP Port Configuration Commands
3RUWFRQILJXUDWLRQFRPPDQGVDOORZ\RXWRFRQILJXUH/$1:(%UHPRWHPRGHPDQGORFDO
SRUWV
127(,I\RXDUHQRWFRQQHFWLQJDQ\WKLQJWRDSRUWKDUGZDUHIORZFRQWUROVKRXOGEHRII
Command
Description
Serial Port Configuration
CA
Configure serial ports
SA
Enable/disable remote and modem access
PG
Paging parameter setup
LAN Configuration
SA
Enable/disable LAN and web access
LC
LAN configuration menu
Connections Commands
&RQQHFWLRQVFRPPDQGVSURYLGHDPHDQVIRUH[DPLQLQJDQGPDNLQJFRQQHFWLRQVRUFKDQJLQJ
PRGHV
3–40
Command
Description
DI
Disconnect remote or LAN connection
TE
Send message to other user
WHO
Display a list of connected users43
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Baseboard Management Controller (BMC)
7KLVVHFWLRQH[SODLQVWKH%0&FRPPDQGOLQHLQWHUIDFH7RSLFVLQFOXGH
■
¦$FFHVVLQJWKH%0&²SDJH
■
¦8VLQJWKH%0&&RPPDQG/LQH,QWHUIDFH&/,²SDJH
■
¦6LPSOH&RPPDQGV²SDJH
■
¦,30,&RPPDQGV²SDJH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–41
System Configuration
Accessing the BMC
7RORJLQWRWKH%0&FRPPDQGOLQHLQWHUIDFHXVHDVHULDOFRQQHFWLRQDQGWHUPLQDOHPXODWLRQ
VRIWZDUH
127(7KHGHIDXOWWHUPLQDOHPXODWLRQW\SHLV977HUPLQDOHPXODWLRQIRUWKH%0&FDQQRW
EHFKDQJHG7KHGHIDXOWEDXGUDWHLV7KLVVHWWLQJFDQEHFKDQJHGIURPWKH(),%RRW
2SWLRQV0DLQWHQDQFH0HQX
:LWKWKHV\VWHPWXUQHGRIIFRQQHFWDQXOOPRGHPFDEOHWR6HULDO3RUWRQWKHUHDUSDQHORI
WKHV\VWHPDQGWR\RXUUHPRWHGHYLFH
&RQILJXUHWKHWHUPLQDOHPXODWLRQVRIWZDUHZLWKWKHVHVHWWLQJV
❏
%DXGUDWH
❏
%LWV
❏
3DULW\1RQH
❏
6WRS%LWVRQH
❏
)ORZ&RQWURO;21;2))
8VLQJWKHWHUPLQDOHPXODWLRQFRQQHFWWRWKHV\VWHPZLWKDGLUHFWFRQQHFWLRQ
7XUQRQWKHV\VWHP7KH(),PHQXGLVSOD\VLQWKHWHUPLQDOZLQGRZ
7RDFFHVVWKH%0&FRPPDQGOLQHLQWHUIDFHSUHVVEsc (
)RUH[DPSOHRQD864:(57<NH\ERDUGSUHVVEscWKHQSUHVVShiftDQG9DWWKHVDPH
WLPH
127(,I$&SRZHULVFRQQHFWHGWRWKHV\VWHPWKLVFRPPDQGDFWLYDWHVWKH%0&FRPPDQGOLQH
LQWHUIDFHHYHQLIWKHV\VWHPSRZHULVRII
,ISURPSWHGHQWHUWKHXVHURUDGPLQSDVVZRUGDWWKHORJLQSURPSW
login>
<RXDUHQRWSURPSWHGIRUDSDVVZRUGLIQRQHKDVEHHQGHILQHG
7KH%0&SURPSWGLVSOD\V,I\RXHQWHUHGWKHDGPLQSDVVZRUG\RXKDYHIXOODFFHVV,I\RX
HQWHUHGWKHXVHUSDVVZRUG\RXKDYHUHVWULFWHGDFFHVV
Admin Session Initiated
cli>
or
User Session Initiated
cli>
3–42
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Using the BMC Command Line Interface (CLI)
7KH%DVHERDUG0DQDJHPHQW&RQWUROOHUVXSSRUWVWKHLQGXVWU\VWDQGDUG,QWHOOLJHQW3ODWIRUP
0DQDJHPHQW,QWHUIDFHVSHFLILFDWLRQ,30,ZLWK([WHQVLRQV7KLVVSHFLILFDWLRQGHVFULEHVWKH
PDQDJHPHQWIHDWXUHVWKDWKDYHEHHQEXLOWLQWRWKHV\VWHPERDUG7KHVHIHDWXUHVLQFOXGH
■
GLDJQRVWLFVORFDODQGUHPRWH
■
FRQVROHVXSSRUW
■
FRQILJXUDWLRQPDQDJHPHQW
■
KDUGZDUHPDQDJHPHQW
■
WURXEOHVKRRWLQJ
7KHUHDUHWZRFDWHJRULHVRI%0&FRPPDQGV
■
6LPSOHFRPPDQGV
■
,QWHOOLJHQW3ODWIRUP0DQDJHPHQW,QWHUIDFH,30,FRPPDQGV
7KLVVHFWLRQSURYLGHVDEULHIRYHUYLHZRIWKHDYDLODEOHFRPPDQGV)RUGHWDLOHGLQIRUPDWLRQVHH
WKH,QWHOZHEVLWH
http://www.intel.com/design/servers/ipmi
Executing BMC Commands
7RH[HFXWH%0&FRPPDQGVDWWKHFRPPDQGSURPSW
7\SHWKHFRPPDQGDQGDQ\UHTXLUHGSDUDPHWHUVDIWHUWKHcli> SURPSW
8VHWKHBackspaceNH\WRFRUUHFWPLVWDNHV
3UHVVEnterWRH[HFXWHWKHFRPPDQG
Logging Out of the BMC Command Line Interface
:KHQ\RXDUHILQLVKHGXVLQJWKH%0&&/,
,I\RXKDYHDV\VWHPSDVVZRUGVHWWRORJRXWRIWKH%0&ZLWKRXWUHWXUQLQJWRWKHV\VWHP
FRQVROHH[HFXWH
Q
7KH%0&ORJLQSURPSWGLVSOD\V
login>
7RORJRXWRIWKH%0&DQGUHWXUQWRWKHV\VWHPFRQVROHSUHVVEsc QSUHVVEscWKHQSUHVV
ShiftDQGQDWWKHVDPHWLPH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–43
System Configuration
Simple Commands
6LPSOH,30,FRPPDQGVDOORZ\RXWRFRQWUROWKH%0&LQWHUIDFHYLHZORJVJHWKHOSDQGFKDQJH
\RXUSDVVZRUG
7RH[HFXWHVLPSOH%0&FRPPDQGV
7\SHWKHFRPPDQGIROORZHGE\DQ\UHTXLUHGRSWLRQV7KHWDEOHEHORZGHVFULEHVWKHVLPSOH
FRPPDQGV
3UHVVEnter
,ISURPSWHGIRUDGGLWLRQDOLQIRUPDWLRQHQWHULWWKHQSUHVVEnter)RUH[DPSOH
cli> c
Type the new password> ****
Retype the new password> ****
New password confirmed.
cli>
Command Syntax Options
3–44
Mode Description
C
Prompts user for User
new password
Allows user to change the password.
FPL
N/A
User
Reads the forward progress log. This log is
encoded and can be used by HP support
representatives. For additional information see
“SEL and FPL Log Entries” on page D-4.
H
N/A
User
Displays list of BMC commands.
INFO
N/A
User
Displays the BMC firmware revision.
LOC [0, 1]
0=off
1=on
User
Turns the system locator LED on or off.
P [0, 1]
0=off
1=on
User
Forces system power on or off; does not shut
down using OS procedures. If you do not enter a
parameter, displays the current power state.
Q
N/A
User
Logs out user; does not close BMC session.
RS
N/A
User
Resets the system.
SD
N/A
User
Displays the SDR repository. This data is
encoded according to the IPMI spec and can be
used by HP support representatives.
SE
N/A
User
Displays system event log (SEL). This log is
encoded and can be used by HP support
representatives. For additional information see
“SEL and FPL Log Entries” on page D-4.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
IPMI Commands
,30,FRPPDQGVDOORZ\RXWRFRPPXQLFDWHZLWKDQGFRQILJXUHYDULRXVFRPSRQHQWVRIWKH
V\VWHP,30,FRPPDQGVDUHDYDLODEOHRQO\WRXVHUVZLWK$GPLQOHYHODFFHVV
Ä
CAUTION: DO NOT run BMC IPMI commands unless you are experienced with the IPMI specification. If
you make mistakes running these commands, you can accidentally delete or modify data and cause your
system to operate unpredictably or fail to operate.
$OO,30,FRPPDQGVUHTXLUHDVHTXHQFHRIKH[FRGHVXVHGDVSDUDPHWHUV(DFKFRPPDQGPD\
LQFOXGHVRPHRUDOORIWKHIROORZLQJSDUDPHWHUV
■
1HWZRUN)XQFWLRQDQG/XQ1HW)Q/XQ7KH1HW)QSDUDPHWHULGHQWLILHVWKHPHVVDJH
FDWHJRU\7KH/81YDOXHLVDOZD\V
■
&RPPDQG7KHPHVVDJHVVSHFLILHGLQWKLVGRFXPHQWFRQWDLQDRQHE\WHFRPPDQGILHOG
&RPPDQGVZLWKLQHDFKFDWHJRU\DUHXQLTXH&RPPDQGYDOXHVFDQUDQJHIURPKWKURXJK
)'K)(KLVUHVHUYHGIRUIXWXUHH[WHQVLRQRIWKHVSHFLILFDWLRQDQG))KLVUHVHUYHGIRU
PHVVDJHLQWHUIDFHOHYHOHUURUUHSRUWLQJRQSRWHQWLDOIXWXUHLQWHUIDFHV
■
'DWD7KH'DWDILHOGFDUULHVWKHDGGLWLRQDOSDUDPHWHUVIRUDUHTXHVWRUDUHVSRQVHLIDQ\
7KH,30,FRPPDQGVFDQEHHQWHUHGLQORQJRUVKRUWIRUPV7KHDVVRFLDWHGUHVSRQVHIURPWKH
%0&PDWFKHVWKHIRUPRIWKHFRPPDQG
)RUH[DPSOH
■
6KRUWIRUPDWRUipmiFRPPDQG
❏
6\QWD[
ipmi NetFnLun Cmd Data1 Data2 ... DataN
❏
6DPSOHFRPPDQGDQGV\VWHPUHVSRQVH
cli> ipmi 18 04
00 55 00
cli>
■
/RQJIRUPDWRUiFRPPDQG
❏
6\QWD[
i 0 NetFnLun 0 0 0 Cmd Data1 Data2 ... DataN 0
❏
6DPSOHFRPPDQGDQGV\VWHPUHVSRQVH
cli> i 20 18 C8 f0 04 04 08
F0 1C F4 20 04 04 00 55 00 83
cli>
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–45
System Configuration
/RQJIRUPDW,30,FRPPDQGV¦,§XVHDQ$6&,,WUDQVFULSWLRQRIWKH,30,GDWDIRUPDW7KH
IROORZLQJH[DPSOHVLOOXVWUDWHKRZ,30,FRPPDQGVDQGUHVSRQVHVDUHVWUXFWXUHG
127($OOQRQFRPPDQGE\WHVFDQEHUHSODFHGZLWK
Long Format IPMI Command Data Structure Example
Bits
Byte
7-2
1-0
rsSa = 0x20
NetFn = 0x07
0x20
rsLUN = 0x00
0x18
Checksum = 0xC8
0xC8
rqSWID = 0xF0
0xF0
rqSeq = 0x01
rqLUN = 0x00
0x04
Cmd = 0x04
0x04
Checksum = 0x08
0x08
Long Format IPMI Response Data Structure Example
Bits
Byte
7-2
1-0
rqSWID = 0xF0
NetFn = 0x07
rsLUN = 0x00
0x1C
Checksum = 0xF4
0xF4
rsSA = 0x20
0x20
rqSeq = 0x01
3–46
0xF0
rsLUN = 0x00
0x04
Cmd = 0x04
0x04
Data byte 1 = 0x00 (completion code)
0x00
Data byte 2 = 0x55 (result = no error)
0x55
Data byte 3 = 0x00 (details)
0x00
Checksum = 0x83
0x83
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
7KH%0&VXSSRUWVWKHYHUVLRQ,30,FDWHJRULHVDQGFRPPDQGVOLVWHGLQWKHIROORZLQJWDEOHV
)RUGHWDLOHGLQIRUPDWLRQRQWKH,30,VSHFLILFDWLRQDQGFRPPDQGVVHHWKH,QWHOZHEVLWH
http://www.intel.com/design/servers/ipmi
Command Categories
NetFn
NetFn << 2
Description
00, 01
00, 04
Chassis
04, 05
10, 14
Sensor/Event (S/E)
06, 07
18, 1C
Application
0A, 0B
28, 2C
Storage
32, 33
C8, CC
HP Custom (proprietary)
Chassis Commands
Command
Description
01h
Get chassis status
02h
Chassis control
0Fh
Get power-on hours (POH) counter
06h
Set power restore policy
Sensor/Event Commands
Command
Description
01h
Get event receiver
02h
Platform event (a.k.a. “Event Message”)
28h
Set sensor event enable
29h
Get sensor event enable
2Ah
Re-arm sensor events
2Dh
Get sensor reading
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–47
System Configuration
Application Commands
Command
Description
IPM Device “Global” Commands
01h
Get device ID
02h
Cold reset
03h
Warm reset
04h
Get self test results
Broadcast Commands
01h
Broadcast ‘Get Device ID’
System Interface Commands
3–48
2Eh
Set BMC global enables
2Fh
Get BMC global enables
30h
Clear message flags
31h
Get message flags
32h
Enable message channel receive
33h
Get message
34h
Send message
35h
Read event message buffer
36h
Get BT interface capabilities
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Configuration
Command
Description
BMC Watchdog Timer Commands
22h
Reset watchdog timer
24h
Set watchdog timer
25h
Get watchdog timer
Storage Commands
Command
Description
SEL Commands
40h
Get SEL info
41h
Get SEL allocation info
42h
Reserve SEL
43h
Get SEL entry
44h
Add SEL entry
47h
Clear SEL
48h
Get SEL time
49h
Set SEL time
SDR Repository Commands
20h
Get SDR repository info
21h
Get SDR repository allocation info
22h
Reserve SDR repository
23h
Get SDR
28h
Get SDR repository time
29h
Set SDR repository time
FRU Inventory Device Commands
10h
Get FRU inventory area info
11h
Read FRU inventory data
12h
Write FRU inventory data
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
3–49
System Configuration
Firmware upgrades
7RXSGDWHWKHV\VWHPDQG%0&ILUPZDUHRUWKH03FDUGILUPZDUH
'RZQORDGWKHILUPZDUHXSGDWHIURPhttp://www.hp.com/go/bizsupport
)ROORZWKHPHQXSURPSWVWRQDYLJDWHWRWKHVXSSRUWSDJH
◆
6HOHFW download drivers/software
◆
(QWHUWKHSURGXFWQDPHLQWKHVHDUFKILHOGIntegrity rx2600 serverRU
zx6000 workstation
◆
6HOHFWWKHVHDUFKUHVXOW
◆
&KRRVHWKHILUPZDUHUHOHDVH\RXQHHGWRGRZQORDGV\VWHPDQG%0&RU03FDUG
◆
&OLFNWKHi LQIRUPDWLRQLFRQIRULQVWUXFWLRQVRQKRZWRGRZQORDGXQSDFNDQGLQVWDOO
WKHILUPZDUHXSJUDGH
'RZQORDGXQSDFNDQGLQVWDOOWKHILUPZDUHXSJUDGH
([HFXWHWKHinfo fw(),FRPPDQGWRFRQILUPWKDWWKHXSJUDGHZDVVXFFHVVIXO
3–50
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4
Troubleshooting
7KLVFKDSWHUFRQWDLQVWKHIROORZLQJVHFWLRQVZKLFKGHVFULEHKRZWRLGHQWLI\DQGVROYHFRPPRQ
SUREOHPV\RXPD\HQFRXQWHUZKHQXVLQJ\RXU+3,QWHJULW\U[VHUYHUDQG+3ZRUNVWDWLRQ
][
■
¦,GHQWLI\LQJDQG'LDJQRVLQJ+DUGZDUH3UREOHPV§RQSDJH
■
¦5XQQLQJ'LDJQRVWLF6RIWZDUH7RROV§RQSDJH
Identifying and Diagnosing Hardware Problems
6KRXOGDKDUGZDUHIDLOXUHRFFXUWKHV\VWHP/('VDQGHEX]]HUZLOOKHOS\RXLGHQWLI\WKH
SUREOHP
■
6\VWHPEHHSVDQGHEX]]HU7KHU[][KDVDQHEX]]HUWKDWEHHSVLQVSHFLILF
SDWWHUQVWRLGHQWLI\HUURUVZKHQWKHV\VWHPERRWV7KHHEX]]HUFDQDOVRVHQGHQFRGHGGDWD
RYHUWKHSKRQHWRKHOSVXSSRUWUHSUHVHQWDWLYHVLGHQWLI\PRUHFRPSOH[SUREOHPV
■
/('V7KHOLJKWVRQWKHIURQWEH]HORIWKHV\VWHPFKDQJHFRORUDQGEOLQNLQGLIIHUHQWSDWWHUQV
WRKHOSLGHQWLI\VSHFLILFKDUGZDUHSUREOHPV/('VRQWKHUHDUSDQHORIWKHV\VWHPGLVSOD\
/$1VWDWXV
■
7KH6\VWHP(YHQW/RJ6(/SURYLGHVGHWDLOHGLQIRUPDWLRQDERXWWKHHUURUVLGHQWLILHGE\
WKHHEX]]HUDQG/('V6HHVHHSDJHDQGSDJH'
,IWKH/('VDQGHEX]]HUGRQRWJLYH\RXHQRXJKLQIRUPDWLRQIRU\RXWRLGHQWLI\WKHSUREOHP
\RXDUHH[SHULHQFLQJ+3DOVRSURYLGHVGLDJQRVWLFWRROVZLWKHDFKRSHUDWLQJV\VWHP
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–1
Troubleshooting
The System e-buzzer
,IDSUREOHPLVGHWHFHGDWDQ\WLPHZKHQWKHV\VWHPLVERRWLQJRUUXQQLQJWKHHEX]]HUHPLWV
DXGLEOHEHHSVDQGDQHQFRGHGHUURUPHVVDJH
■
7KHDXGLEOHEHHSVFRQVLVWRIDPRGHPOLNHVRXQGUHSHDWHGWLPHVIROORZHGE\EHHSVRI
DVLQJOHIUHTXHQF\DWVHFRQGGXUDWLRQVHDFKVHSDUDWHGE\VHFRQG7KHHEX]]HUHPLWVD
GLIIHUHQWQXPEHURIEHHSVIRUHDFKW\SHRIHUURU0RUHGHWDLOHGLQIRUPDWLRQLVSURYLGHGE\
WKH/('V
■
7KHHOHFWURQLFVLJQDOFDQEHVHQWWKURXJKDWHOHSKRQHOLQHWRDQDXWKRUL]HGKHOSGHVNRU+3
6XSSRUW7KLVVLJQDOFDQEHGHFRGHGE\KHOSGHVNHTXLSPHQWWRH[WUDFWWKHV\VWHPPRGHO
VHULDOQXPEHUDQGGHWDLOVDERXWDQ\IDXOWV7RVHQGWKLVVLJQDOWR+36XSSRUWKROG\RXU
WHOHSKRQHQH[WWRWKH/('RQWKHV\VWHPIURQWEH]HOZKHQWKHV\VWHPLVERRWLQJ
■
7KHHEX]]HUGRHVQRWUHSRUWDOOSUREOHPVRQO\WKHSUREOHPVOLVWHGEHORZ,IWKHHEX]]HU
LQGLFDWHVDQHUURUFKHFNWKH6(/VHHSDJHDQGSDJH'IRUDPRUHGHWDLOHG
H[SODQDWLRQVRIWKHIDLOXUH
Number of
Beeps
Component
Description
1
Processor
Processor absent or not correctly connected. Reseat or replace
processor.
2
Power supply
Power supply failure. Replace power supply.
3
Memory
No memory, bad memory modules or incompatible memory
module. Check memory module loading order. Reseat or
replace memory modules.
4
Graphics card
Graphics card problem. Reseat or replace the graphics card.
5
PCI card
PCI card problem. Reseat or replace the PCI card.
6
Critical system
failure
Contact support.
7
System board
•
System Fault caused by hardware failure or software fault.
•
Two minutes has elapsed after the BMC starts system power
and no BOOT_START event is logged in the SEL. Possible
problems include:
•
Clock is bad
•
System board problem
•
CPU connection to the board bad
•
CPU power pod failure
•
CPU failure
•
Corrupt Firmware (bad code, or improper update)
Defective system board. Contact support.
127()RUGHWDLOHGLQVWUXFWLRQVRQUHPRYLQJDQGUHSODFLQJV\VWHPFRPSRQHQWVVHH&KDSWHU
¦,QVWDOOLQJRU5HSODFLQJ3DUWVDQG$FFHVVRULHV§
4–2
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
7KHH%X]]HUPD\DOVREHDFWLYDWHGE\VHYHUDORWKHUHYHQWV
■
,IWKHV\VWHPILUPZDUHGHWHFWVDQHUURUGXULQJV\VWHPRSHUDWLRQWKH%0&ZLOOWULJJHUWKH
H%X]]HUWRVRXQG
■
,I\RXPLVVWKHEHHSFRGHFRXQWGXULQJWKHLQLWDOWUDQVPLVVLRQVHTXHQFHWULJJHUWKHVHTXHQFH
DJDLQE\SUHVVLQJDQGKROGLQJWKHV\VWHPSRZHUEXWWRQIRUVHFRQGVDQGUHOHDVHLWDVVRRQ
DVWKHVRXQGEHJLQV
7KHSRZHUEXWWRQRQWKHIURQWSDQHORSHUDWHVGLIIHUHQWO\GHSHQGLQJRQKRZORQJWKHEXWWRQLV
SUHVVHGDQGZKHWKHURUQRWWKHV\VWHPZDVRQRURIIZKHQWKHEXWWRQZDVSUHVVHG
■
■
■
:KHQWKHV\VWHPSRZHULVRII
❏
VHFRQGV6\VWHPSRZHUWXUQVRQ7KHHEX]]HUZLOOEHHSLIDQHUURULVHQFRXQWHUHG
❏
VHFRQGV7KHHEX]]HUZLOOUHSHDWWKHODVWVWRUHGHUURU
:KHQWKHV\VWHPSRZHULVRQDQGWKHV\VWHPLVDWWKH(),
❏
VHFRQGV6\VWHPSRZHUWXUQVRIILPPHGLDWHO\
❏
VHFRQGV7KHHEX]]HUZLOOUHSHDWWKHODVWVWRUHGHUURU
❏
VHFRQGVRUORQJHU6\VWHPSRZHUWXUQVRIILPPHGLDWHO\
:KHQWKHV\VWHPSRZHULVRQDQGWKH26LVUXQQLQJ
❏
VHFRQGV6\VWHPSRZHUWXUQVRIIYLD$&3,VLJQDOWR266RIWSRZHUGRZQ
❏
VHFRQGV7KHHEX]]HUZLOOUHSHDWWKHODVWVWRUHGHUURU
❏
VHFRQGVRUORQJHU6\VWHPSRZHUWXUQVRIILPPHGLDWHO\+DUGSRZHUGRZQ
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–3
Troubleshooting
The Diagnostic LEDs
'LDJQRVWLF/('VDUHRQWKHIURQWSDQHORIWKHV\VWHP7KHIROORZLQJVHFWLRQVGHVFULEHWKHLU
IXQFWLRQV)RUWKHIXQFWLRQRIRWKHU/('VVHHWKH+3,QWHJULW\U[VHUYHUDQG+3
ZRUNVWDWLRQ][*HWWLQJ6WDUWHG*XLGH$GGLWLRQDOGLDJQRVWLF/('VDUHRQWKHV\VWHPERDUG
,IWKHV\VWHPKDVQR03FDUGLQVWDOOHGWKHIRXUGLDJQRVWLF/('VRQWKHIURQWSDQHOZDUQRI
LPSHQGLQJIDLOXUHVDQGDOORZ\RXWRWDNHSUHYHQWLYHDFWLRQ)RUH[DPSOH\RXPD\ZDQWWREDFN
XS\RXUGDWDRUUHSODFHDFRPSRQHQWEHIRUHLWIDLOV
■
,IQR03FDUGLVLQVWDOOHGWKHERRWSURJUHVVLVPRQLWRUHGE\'LDJQRVWLF/('V'XULQJ
WKHERRWXSWKH/('VZLOOWXUQRQLQVHTXHQFHXQWLOWKH(),SURPSWLVUHDFKHG
■
,IDQ03FDUGLVLQVWDOOHGWKHERRWSURFHVVZLOOEHPRQLWRUHGE\WKH03FDUG7KH/('VZLOO
EHRII
Power and System LEDs
7KH3RZHUDQG6\VWHP/('VLQGLFDWHWKHVWDWHRIWKHV\VWHP:KHQWKH6\VWHP/('LV
EOLQNLQJRUDQJHRUUHGDSUREOHPH[LVWV
systems with MP card
7KHIROORZLQJV\VWHP/('VWDWHVH[LVWIRUV\VWHPVZLWKDQ03FDUG6HHWKH6/ORJVIRU
DGGLWLRQDOLQIRUPDWLRQ
System LED
State
Off
Off
Solid green
Running OS
Blinking green
Booting or running EFI
Blinking orange (1/sec.)
Attention:
• Alerts of levels 3-5 detected in the MP logs.
• The LED will turn off once the event log has been read.
Blinking red (2/sec.)
Fault:
• System Alert 7 Detected. LED blinks until the problem is
resolved and the system boots successfully or until it is
manually turned off with the MP dc command.
• Fatal hardware error detected by BMC. LED blinks until
problem is corrected.
)RUV\VWHPDOHUWVRIOHYHOVWKHDWWHQWLRQFRQGLWLRQRQWKH/('FDQEHFOHDUHGE\DFFHVVLQJ
WKHORJVXVLQJWKHslRUdcFRPPDQGDYDLODEOHLQWKH03FRPPDQGPRGH
6\VWHPDOHUWVRIOHYHOLQGLFDWHWKDWWKHV\VWHPFDQQRWFRPSOHWHWKHSRZHURQVHOIWHVW3267
5HIHUWRWKH6/HUURUORJVIRUDGGLWLRQDOHUURULQIRUPDWLRQ2QFHFRUUHFWLYHDFWLRQKDVEHHQ
FRPSOHWHGWKHIDXOW/('ZLOOWXUQRII
127($OZD\VFKHFNWKH036WDWXV/RJVLQWKHFDVHRIDEOLQNLQJRUDQJHRUUHG6\VWHP/('
EHIRUHUHSODFLQJDQ\KDUGZDUH
4–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
System Logs (SL) Logs
7RYLHZWKH6/ORJVIRUGHWDLOHGGLDJQRVWLFLQIRUPDWLRQXVHWKHsl03FRPPDQG
$FFHVVWKH03FRPPDQGSURPSWSDJH
5XQWKH slFRPPDQG7KH(YHQW/RJ9LHZHUPHQXGLVSOD\V
SL
Event Log Viewer:
Log Name
Entries
% Full
Latest Entry
---------------------------------------------------------------E - System Event
9
1 %
29 Oct 2002 19:15:05
F - Forward Progress 129
3 %
B - Current Boot
82
P - Previous Boot
0
L - Live Events
C - Clear All Logs
Enter your choice or [Q] to Quit:
6HOHFWeWRUHYLHZWKHHYHQWV7KH(YHQW/RJ1DYLJDWLRQPHQXGLVSOD\V
Set up alert filter options on this buffer? (Y/[N])
Log Name
Entries
% Full
Latest Entry
------------------------------------------------------------------E - System Event
410
47 %
18 Feb 2003 09:38:10
Event Log Navigation Help:
+
<CR>
D
F
L
J
V
?
Ctrl-B
View next block
(forward in time, e.g. from 3 to 4)
View previous block (backward in time, e.g. from 3 to 2)
Continue to the next or previous block
Dump the entire log for capture and analysis
First entry
Last entry
Jump to entry number
View mode configuration (text, keyword, hex)
Display this Help menu
Quit and return to the Main Menu
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–5
Troubleshooting
6HOHFWvWKHQtWRFKDQJHWKHGLVSOD\WRWH[WPRGH
Display Mode Configuration:
H - Hex mode
Current -> K - Keyword mode
T - Text mode
Enter new value, or [Q] to Quit:
7RGHFRGHWKHEOLQNLQJVWDWHRI6\VWHP/('UHYLHZWKHHQWLUH6(/DQGORRNDWHYHQWVZLWK
DOHUWOHYHODQGDERYH
)RUH[DPSOH
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC; Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC; Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
4–6
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
Systems with no MP card
7KHIROORZLQJV\VWHP/('VWDWHVH[LVWIRUV\VWHPVZLWKRXW03FDUG6HHWKH'LDJQRVWLF/('V
IRUDGGLWLRQDOLQIRUPDWLRQ
Power LED
System LED
State
Off
Off
Off
On (green)
Solid green
Running
On (green)
Blinking green
Booting
On (green)
Blinking orange (1/sec.)
Attention
On (green)
Blinking red (2/sec.)
Fault
Diagnostic LEDs
7KHIRXUGLDJQRVWLF/('VRQWKHIURQWEH]HORIWKHV\VWHPDUHXVHGIRUGLDJQRVLQJWKHKHDOWKRI
WKHV\VWHP5HIHUWRWKH6(/DQG)3/ORJVIRUVSHFLILFLQIRUPDWLRQDERXWWKHZDUQLQJRUIDLOXUH
LQGLFDWHGE\WKHGLDJQRVWLFV/('V
7KHVH/('VZDUQRILPSHQGLQJKDUGZDUHIDLOXUHVDQGDOORZ\RXWRWDNHSUHYHQWLYHDFWLRQVXFK
DVPDNLQJDV\VWHPEDFNXSRUUHSODFLQJDFRPSRQHQWEHIRUHLWIDLOV7KHVHGLDJQRVWLF/('VDUH
ODEHOHGDQG
7KHORFDWLRQRIUHG/('VFDQEHXVHGWRLGHQWLI\WKHFDWHJRU\RIWKHIDXOWRUZDUQLQJ)RU
H[DPSOHLI/('RQHLVUHGWKHUHLVDSUREOHPZLWKPHPRU\+RZHYHULI/('VRQHDQGWZRDUH
ERWKUHGWKHUHLVDSUREOHPZLWKWKHV\VWHPSURFHVVRU
,IWKHGLDJQRVWLF/('VLQGLFDWHDQHUURUFKHFNWKH6(/VHHSDJHDQGSDJH'IRUDPRUH
GHWDLOHGH[SODQDWLRQVRIWKHIDLOXUH
7KHIROORZLQJV\PEROVDUHXVHGLQWKH/('WDEOHV
■
7KH6\VWHP/('LQGLFDWHVWKHVHYHULW\RIWKHHUURU&KHFNWKLV/('EHIRUH
SURFHHGLQJWRDQDO\]HWKHVHTXHQFHRIGLDJQRVWLF/('V
%OLQNLQJRUDQJHLQGLFDWHVD:$51,1*
%OLQNLQJUHGLQGLFDWHVD)$8/7
■
7KH'LDJQRVWLF/('VSURYLGHGHWDLOVDERXWWKHVSHFLILFHUURU
6ROLGUHGLQGLFDWHVWKHIDLOLQJSDUWRUVXEV\VWHP
2IIRUVROLGJUHHQGLDJQRVWLF/('VSURYLGHDGGLWLRQDOGHWDLOVDERXWWKH
IDLOXUH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–7
Troubleshooting
7KHIDXOWVDQGZDUQLQJVIDOOLQWRVHYHUDOJHQHUDOFDWHJRULHV
LED1
4–8
LED2
LED3
LED4
Category
e-buzzer
Beeps
Memory
3
Firmware
6
System Board
7
Fan
None
Processor
1
BMC
7
Temperature
None
Power Supply
2
Unknown
None
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
Warnings
7KHIROORZLQJWDEOHVSURYLGHDGGLWLRQDOLQIRUPDWLRQDERXWHDFKVSHFLILFZDUQLQJDVVRFLDWHGZLWK
WKHYDULRXVSRVVLEOH/('OLJKWLQJVHTXHQFHVZKHQWKHV\VWHP/('LVRUDQJH
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
Unknown Warnings
Unknown warning
View the SEL for
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
Memory Warnings
Mismatched memory Use the memory
pairs
sequence diagram on
page 2-25.
Memory thermal
load order
Use the memory
sequence diagram on
page 2-25.
Bad SPD information View the SEL for
(can't detect type)
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
System Board Warnings
Battery voltage low
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Replace the system
board battery.
4–9
Troubleshooting
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
Fan Warnings
Fan 1A not
functioning properly
Fan 1B not
functioning properly
CPU fan 0 not
functioning properly
CPU fan 1 not
functioning properly
Replace the fan that is
not functioning.
If a processor fan has
failed, you must
replace the CPU.
Fan module 2
(memory) not
functioning properly
Fan module 3
(Disks/PCI) not
functioning properly
4–10
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
Processor Warnings
Processor 0
temperature exceeds
limit
Processor 1
temperature exceeds
limit
If a processor fan has
failed, you must
replace the CPU.
Temperature Warnings
External air
temperature too
high
Make sure nothing is
blocking the system’s
airflow and locate your
system in an
air-conditioned room.
No video adapter
present
Install a video adapter.
See the installation
instructions shipped
with the video adapter.
Video Warnings
Power Supply Warnings
Power supply 1 fault
Power supply 2 fault
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Replace the power
supply.
4–11
Troubleshooting
Faults
7KHIROORZLQJWDEOHVSURYLGHDGGLWLRQDOLQIRUPDWLRQDERXWHDFKVSHFLILFIDXOWDVVRFLDWHGZLWKWKH
YDULRXVSRVVLEOH/('OLJKWLQJVHTXHQFHVZKHQWKHV\VWHP/('LVUHG
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
Unknown Faults
Unknown fault
View the SEL for
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
Mismatched memory pairs
Use the memory
sequence diagram on
page 2-25.
Uncorrectable memory error
Replace memory.
No memory installed
Install memory.
Bad memory; one or more
DIMMs are bad or not seated
properly
Reseat the DIMMs. If the
error persists, replace
them.
Memory Faults
Firmware Errors
System firmware hang or system View the SEL for
fault
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
4–12
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
System Board Faults
VRM overvoltage
View the SEL for
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
VRM undervoltage
View the SEL for
additional information
(page D-4). For futher
assistance, contact your
HP Support Engineer.
Fan Faults
rs2600: Cooling unit 1 fault
(power/CPU)
zx6000: Cooling unit 1 fault
rs2600: Cooling unit 2 fault
(memory)
zx6000: Cooling unit 2 fault
(disks/PCI)
Replace the failed fan.
If a processor fan has
failed, you must
replace the CPU.
rs2600: Cooling unit 3 fault
(Disks/PCI)
zx6000: N/A
Processor Faults
Processor 0 temperature
exceeds limit
Processor 1 temperature
exceeds limit
If a processor fan has
failed, you must
replace the CPU.
No processor detected
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–13
Troubleshooting
System
LED
LED1
LED2
LED3
LED4
Problem
Solution
BMC Faults
BMC firmware is damaged
Turn off and unplug the
system. Wait 20
seconds, then plug in
and restart the system. If
the error repeats,
replace the system
board.
System board FRU inventory
device inaccessible
Replace the system
board.
External air temperature too
high
Make sure nothing is
blocking the system’s
airflow and locate your
system in an
air-conditioned room.
Temperature Faults
Power Supply Errors
VRM or power pod fault
Power Supply 1 fault
View the SEL for
additional information
(page D-4). For more
help, contact your HP
Support Engineer.
Power Supply 2 fault
12V out of range (power supply
interface fault)
4–14
Replace the power
supply.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
LAN LEDs
7KHIURQWSDQHO/$1/('LQGLFDWHVWKHV\VWHPLVFRPPXQLFDWLQJRYHUWKH*LJDELWRU6\VWHP
0DQDJHPHQW/$1
■
EOLQNLQJJUHHQWKHV\VWHPLVFRPPXQLFDWLQJRYHUWKH/$1
■
VROLGJUHHQ/$1OLQNLVHVWDEOLVKHGQRFXUUHQW/$1DFWLYLW\
■
QRWJUHHQWKHV\VWHPLVRII
)RXU*LJDELW/$1/('VDUHRQWKHUHDUSDQHO
1
2
4
3
2
1
3
4
LAN LED
Location
Color
State
1. Gbit
Tower: Right
Off
No 1000 Mbps link
Rack-mounted: Top
Green
Port linked at 1000 Mbps
Tower: 2nd from right
Off
No 100 Mbps link
Rack-mounted: 2nd from top
Green
Port linked at 100 Mbps
Tower: 2nd from left
Off
No 10 Mbps link
2. 100mb
3. Link
4. Activity
Rack-mounted: 2nd from bottom Green
Port linked at 10 Mbps
Tower: Left
Off
No LAN activity
Rack-mounted: Bottom
Green
Flashing or solid green LED indicates
activity on LAN port
7ZR6\VWHP0DQDJHPHQW/$1/('VDUHRQWKHUHDUSDQHO
1
2
2
1
LAN LED
Location
Color
State
1. Speed
Tower: Right
On
Port linked at 100 Mbps
Rack-mounted: Top
Off
Port linked at 10 Mbps
Tower: Left
On
Port linked
Rack-mounted: Bottom
Off
No link established
2. Activity
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–15
Troubleshooting
)RXU03/$1/('VDUHDOVRRQWKHUHDUSDQHOLIWKHV\VWHPKDVD03FDUGLQVWDOOHG
1
2
4
3
2
1
3
4
LAN LED
Location
Color
State
1. Self-test
Tower: Right
Yellow
MP running self test or error
Rack-mounted: Top
Off
MP has booted
Tower: 2nd from right
Green
10 Mb link established
Rack-mounted: 2nd from top
Blinking Green
10 Mb activity
Off
No link or 100 Mb link
Green
100 Mb link established
2. 10BT
3. 100BT
Tower: 2nd from left
Rack-mounted: 2nd from bottom Blinking Green
4. Standby
Power
4–16
100 Mb activity
Off
No link or 10 Mb link
Tower: Left
Green
Standby power on
Rack-mounted: Bottom
Off
Standby power off
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
System Board Diagnostic LEDs
7KHUHDUHWKUHHDGGLWLRQDO/('VWKDWFDQKHOSZKHQWURXEOHVKRRWLQJWKHV\VWHP7KHVH/('VDUH
ORFDWHGRQWKHV\VWHPERDUGFORVHWRWKHEDFNRIWKHV\VWHPDQGFDQEHYLHZHGWKURXJKWKHVPDOO
FRROLQJKROHVLQWKHV\VWHPFDVH
1
2, 3
1
2
3
Location of the STBY LED, F/W LED and BMC LED
LED
Description
1 STBY
This standby LED comes on as soon as the system power cord is plugged in.
If this light is off when you plug it in, reseat the power supply, and if this
does not work, replace the power supply. See Chapter 2 for instructions.
2 BMC
A few seconds after the system is plugged in this LED starts blinking, which
means that the Baseboard Management Controller is alive. If this LED is not
blinking and the STBY (standby) LED is on, you may have to replace the
system board.
3 F/W
A few seconds after the power button is pressed in the system firmware
code fetch LED comes on indicating that the firmware has started the boot
process. If this LED does not come on, you may have to replace the system
board.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–17
Troubleshooting
Running Diagnostic Software Tools
7KLVVHFWLRQLQFOXGHVLQIRUPDWLRQRQWKHIROORZLQJGLDJQRVWLFWRROV
■
+3H'LDJ7RROV+DUGZDUH'LDJQRVWLFV
%HIRUH\RXUXQWKH+3GLDJQRVWLFVRIWZDUHWDNHQRWHRIDQ\HEX]]HUDQG/('HUURUPHVVDJHV
7RILQGRXWPRUHDERXWWKHHUURUQRWHDQ\HYHQWPHVVDJHVDQGXVHWKHWRRODSSURSULDWHIRU\RXU
V\VWHPWRGHWHUPLQHZKDWIDLOHG
127((YHQWPHVVDJHVDUHOLVWHGLQ$SSHQGL['
4–18
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
HP e-DiagTools Hardware Diagnostics
<RXUV\VWHPFDPHZLWKDQ+3,3)2IIOLQH'LDJQRVWLFVDQG8WLOLWLHV&'ZLWK+3H'LDJ7RROV
+DUGZDUH'LDJQRVWLFV7KHVHWRROVPD\EHXVHGWRGLDJQRVHKDUGZDUHUHODWHGSUREOHPVRQ\RXU
+3V\VWHP
5XQH'LDJ7RROVEHIRUHFRQWDFWLQJ+3IRU:DUUDQW\VHUYLFH7KLVLVWRREWDLQLQIRUPDWLRQWKDW
ZLOOEHUHTXHVWHGE\D6XSSRUW$JHQW
:LWKWKLVXWLOLW\\RXFDQ
■
&KHFNWKHKDUGZDUHFRQILJXUDWLRQDQGYHULI\WKDWLWLVIXQFWLRQLQJFRUUHFWO\
■
7HVWLQGLYLGXDOKDUGZDUHFRPSRQHQWV
■
'LDJQRVHKDUGZDUHUHODWHGSUREOHPV
■
2EWDLQDFRPSOHWHKDUGZDUHFRQILJXUDWLRQ
■
3URYLGHSUHFLVHLQIRUPDWLRQWRDQ+3VXSSRUWDJHQWVRWKH\FDQVROYHSUREOHPVTXLFNO\DQG
HIIHFWLYHO\
+3H'LDJ7RROVSURYLGHVDXVHUIULHQGO\LQWHUIDFHWRWKH2IIOLQH'LDJQRVWLFV(QYLURQPHQW
2'(WKDWHQDEOHV\RXWRWURXEOHVKRRWDV\VWHPWKDWLVUXQQLQJZLWKRXWDQ26RUFDQQRWEH
WHVWHGXVLQJWKHRQOLQHWRROV2'(FDQDOVREHUXQVHSDUDWHO\XVLQJDFRPPDQGOLQHLQWHUIDFH
ZKLFKDOORZVWKHXVHUWRVHOHFWVSHFLILFWHVWVDQGRUXWLOLWLHVWRH[HFXWHRQDVSHFLILFKDUGZDUH
PRGXOH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–19
Troubleshooting
Starting HP e-DiagTools
,QVHUWWKH+3,3)2IIOLQH'LDJQRVWLFVDQG8WLOLWLHV&'LQWKH&'RU'9'GULYHRU
GRZQORDGDQGLQVWDOOWKHILOHVIURPwww.hp.com/go/bizsupport
)URPWKH(),VKHOOSDJHVHOHFWWKH&''9'GULYH
D 8VHWKHmapFRPPDQGWROLVWWKHGULYHVRQ\RXUV\VWHP)RUH[DPSOH
Shell> map
Device mapping table
fs0:Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)/CDROM...
fs1:Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)/HD(Part...
blk0:Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)...
blk1:Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)/CDROM...
127(/LQHVDUHWUXQFDWHGWRILW
E &KDQJHWRWKH&''9'GULYH
Shell> fs0:
fs0:>
1DYLJDWHWRWKH(),?%227GLUHFWRU\RQWKH&'
D
&KDQJHWRWKH(),GLUHFWRU\RQWKHGLDJQRVWLFV&'
fs0:> cd EFI
fs0\EFI:>
E ([HFXWHWKHlsFRPPDQGWROLVWWKHFRQWHQWVRIWKHGLUHFWRU\
fs0:\EFI> ls
Directory of: fs1:\EFI
11/07/02
11/07/02
11/07/02
11/07/02
04:41p
04:41p
04:41p
04:45p
<DIR>
<DIR>
<DIR>
<DIR>
1,024 .
0 ..
1,024 HP
1,024 BOOT
0 File(s) 0 bytes
4 Dir(s)
F
&KDQJHWRWKH%227VXEGLUHFWRU\
fs0\EFI:> cd BOOT
fs0\EFI\BOOT:>
G ([HFXWHWKHlsFRPPDQGWROLVWWKHFRQWHQWVRIWKHGLUHFWRU\
fs0:\EFI\BOOT> ls
Directory of: fs1:\EFI\BOOT
11/07/02
11/07/02
11/07/02
11/07/02
11/07/02
11/07/02
11/07/02
5 File(s)
04:45p <DIR>
04:45p <DIR>
01:54p
01:54p
01:54p
01:54p
01:54p
1,024
1,024
731,136
2,763
731,136
2,995
3,977
.
..
LaunchMenu.efi
IO.ini
BOOTIA64.EFI
LaunchMenu.ini
View_Doc.ini
1,472,007 bytes
2 Dir(s)
4–20
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
([HFXWHWKHLaunchMenuFRPPDQGWRUHERRWIURPWKH&'DQGODXQFKH'LDJ7RROV
fs0:\BOOT> launchmenu
,I\RXDUHQRWIDPLOLDUZLWKH'LDJ7RROVUHYLHZWKHGRFXPHQWDWLRQ)URPWKHPDLQPHQX
D 6HOHFW View Release Notes and Documentation Menu WRYLHZDOLVWRIDYDLODEOH
GRFXPHQWDWLRQ
E 6HOHFWView e-DiagTools InfoWRRSHQWKHRYHUYLHZGRFXPHQW
,I\RXDUHDOUHDG\IDPLOLDUZLWKH'LDJ7RROVVHOHFW Run e-DiagTools for IPFIURPWKH
PDLQPHQX
Producing a Support Ticket
7RSURGXFHDFRPSOHWHUHFRUGRI\RXUV\VWHP©VFRQILJXUDWLRQDQGWHVWUHVXOWV\RXPXVWFUHDWHD
6XSSRUW7LFNHW7KLVLVDVLPSOHWH[WILOHWKDWFRQWDLQVHVVHQWLDOLQIRUPDWLRQDQGLVGHVLJQHGWR
DVVLVW\RXUORFDORU+36XSSRUW$JHQW
7RSURGXFHD6XSSRUW7LFNHWIURPWKHWelcome to e-DiagTools0HQX
6WDUWH'LDJ7RROVDQGVHOHFWRun eDiagTools for IPFIURPWKHPDLQPHQX
6HOHFW 2 - Run e-DiagTools Basic System Test (BST)WRUXQWKHEDVLFGLDJQRVWLFVRQ
\RXUV\VWHPLI\RXKDYHQRWDOUHDG\GRQHVR
H'LDJ7RROVVFDQV\RXUV\VWHP7KH&RQILJXUDWLRQ'HVFULSWLRQGLVSOD\VRQWKHVFUHHQZKHQ
WKHFRQILJXUDWLRQGHWHFWLRQSKDVHLVFRPSOHWH
6HOHFW2 - Continue TestWRUXQWKHUHVWRIWKHEDVLFGLDJQRVWLFVWHVW7KHUHVXOWVZLOOGLVSOD\
RQWKHVFUHHQ)RUH[DPSOH
**********************************************
e-Diagtools for IPF rev. A.01.39 (c) Hewlett-Packard Company, 2002
Test Results
Tests passed. No errors found.
If you still experience problems with your system, try the
following:
1. Power off and restart your system.
2. Update the system's firmware.
3. Back up your data and contact your HP Support Agent for more
advice.
1-Help 2-Advanced 3-Exit 4-Support Ticket
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–21
Troubleshooting
$IWHUWKHWHVWLVFRPSOHWHSUHVV47KH6XSSRUW7LFNHWZLOOGLVSOD\RQWKHVFUHHQ)RU
H[DPSOH
-----------------------------------------HEWLETT-PACKARD e-Diagtools Support Ticket
-----------------------------------------~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Your system: HP - zx6000
Diagnostic: System Test Passed
Date/Time: 05/01/2003 14:37:41
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
❏
7KH6XSSRUW7LFNHWLVDVFUHHQWKDWGLVSOD\VDFRPSOHWHUHFRUGRIWKHWHVWUHVXOWVDQGWKH
V\VWHP
VFRQILJXUDWLRQ,WLVWKHPRVWHIIHFWLYHZD\RIFRPPXQLFDWLQJWKLVHVVHQWLDO
LQIRUPDWLRQWR\RXUVXSSRUWSURYLGHU
❏
7KHFXUUHQW6XSSRUW7LFNHWLVWKHRQHSURGXFHGE\WKHODVWH[HFXWLRQRIH'LDJWRROV
:KHQUXQQLQJH'LDJWRROV\RXFDQFUHDWHD6XSSRUW7LFNHWRQGHPDQGLQWKH
&RQILJXUDWLRQ'HVFULSWLRQ6FUHHQ:KHQ\RXUXQWKHEDVLFV\VWHPWHVWVRUDGYDQFHG
V\VWHPWHVWVD6XSSRUW7LFNHWLVFUHDWHGDXWRPDWLFDOO\8VHWKH6XSSRUW7LFNHW6FUHHQWR
EURZVHLWIRULQIRUPDWLRQWKDWFDQKHOS\RXWURXEOHVKRRW\RXUV\VWHP
❏
+DYHWKHVXSSRUWWLFNHWRQWKHVFUHHQZKHQ\RXFRQWDFWFXVWRPHUVXSSRUW8VHWKH
DUURZNH\VWRVFUROOLIQHFHVVDU\7KHVXSSRUWUHSUHVHQWDWLYHPD\DVN\RXWRUHDGWKH
LQIRUPDWLRQRYHUWKHSKRQH
3UHVV3 WRH[LWWKH6XSSRUW7LFNHWWRRO
4–22
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
Offline Diagnostics Environment (ODE)
7KH2IIOLQH'LDJQRVWLFV(QYLURQPHQWLVDQRIIOLQHVXSSRUWWRROVSODWIRUPWKDWHQDEOHVXVHUVWR
WURXEOHVKRRWDV\VWHPWKDWFDQQRWEHWHVWHGXVLQJRQOLQHWRROV7KHVHPD\EHDFFHVVHGWKURXJK
WKH+3H'LDJ7RROV+DUGZDUH'LDJQRVWLFVPHQXVRUDVVHSDUDWHDSSOLFDWLRQV7KHRIIOLQH
HQYLURQPHQWLVDOVRXVHIXOIRUVRPHW\SHVRIWHVWLQJLQZKLFKLWLVQRWGHVLUDEOHWRKDYHWRERRW
WKHV\VWHPILUVW
Tools Provided
7KH2'(LQFOXGHVDYDULHW\RIGLDJQRVWLFVWRROV'HSHQGLQJRQ\RXUV\VWHPDQGFRQILJXUDWLRQ
WKHVHPD\LQFOXGHVRPHRUDOORIWKHIROORZLQJWRROVSOXVDGGLWLRQDOV\VWHPVSHFILFWRROV
■
0$33(5LVDQRIIOLQHV\VWHPFRQILJXUDWLRQPDSSLQJXWLOLW\,WLGHQWLILHVDQGGLVSOD\VDOLVW
RIV\VWHPFRPSRQHQWVLQFOXGLQJKDUGZDUHPRGXOHVDQGSHULSKHUDOGHYLFHV
■
&38',$*LVD&38GLDJQRVWLFVWRRO
■
0(0',$*LVDPHPRU\GLDJQRVWLFVWRRO
■
3(5)9(5LVDXWLOLW\IRUWHVWLQJSHULSKHUDOVDWWDFKHGWRWKHERRWSDWK
7RDFFHVVDGHWDLOHGOLVWRIWRROVSURYLGHGRQ\RXUV\VWHPIURPWKH2'(0DLQ0HQX
6HOHFWView Release Notes and Documentation Menu
%URZVHWKHGRFXPHQWDWLRQDQGUHOHDVHQRWHV
running ODE from the offline Diagnostics and Utilities CD
2'(XVHVDFRPPDQGOLQHLQWHUIDFHZKLFKDOORZVWKHXVHUWRVHOHFWVSHFLILFWHVWVDQGRUXWLOLWLHV
WRH[HFXWHRQDVSHFLILFKDUGZDUHPRGXOH
7RUXQ2'(IURPWKH+3,3)2IIOLQH'LDJQRVWLFVDQG8WLOLWLHV&'
,QVHUWWKH&'LQWRWKH&''9'GULYHDQGUHVHWV\VWHPSRZHUWKHV\VWHPVKRXOGFRPHXSWR
WKHERRWPDQDJHU
,IWKHERRWPDQDJHULVDOUHDG\FRQILJXUHGDQGWKH&''9'GULYHLVFRQILJXUHGDVRQHRIWKH
ERRWGHYLFHV\RXPRYHWKHFXUVRUWRWKHOLQHZKLFKVKRZVWKH&''9'GULYHDQGSUHVV
Enter7KH&'WKHQZLOOERRWWRWKH/DXQFK0HQX
6HOHFWRun the Off-line Diagnostic Environment (ODE) IURPWKHODXQFKPHQX
127(,I\RXDUHXQDEOHWRERRWIURP\RXU&''9'GULYHUHVWDUW\RXUV\VWHPDQGFKHFNWKH
ERRWRSWLRQVIURPWKHBoot Options Maintenance MenuWRHQVXUHWKDW\RXUV\VWHPLV
FRQILJXUHGWRERRWIURPWKH&''9'GULYH
)RUIXUWKHULQIRUPDWLRQVHHhttp://docs.hp.com/hpux/diagXQGHUWKHVHFWLRQWLWOHG
¦2IIOLQH'LDJQRVWLFV§7KLVVLWHLQFOXGHVOLQNVWRD)$4FRQFHSWXDORYHUYLHZDQGDTXLFN
UHIHUHQFHJXLGHWR2'($OVRVHHWKHVHFWLRQWLWOHG¦'LDJQRVWLFV6XSSRUW7RROV*HQHUDO§
HVSHFLDOO\WKH6XSSRUW3OXV'LDJQRVWLF8VHU
V*XLGH&KDSWHU¦8VLQJWKH6XSSRUW3OXV0HGLD
WR5XQ2IIOLQH'LDJQRVWLFV§LVDXVHIXOFKDSWHUIRUPRUHLQIRUPDWLRQRQZKDW2'(LVDQGKRZWR
UXQLW
127(,QJQRUHUHIHUHQFHVWRWKH6XSSRUW3OXV0HGLDLQWKH6XSSRUW3OXV8VHU©V*XLGH&KDSWHU
WKH\GRQRWDSSO\WR][RUU[V\VWHPV+RZHYHUWKHFRQFHSWXDODQGSURFHGXUDO
LQIRUPDWLRQVWLOODSSOLHVWR,3)V\VWHPV$Q\GLVFUHSDQFLHVKDYHEHHQQRWHGDQGH[SODLQHGLQWKH
6XSSRUW3OXV8VHU
V*XLGHDQGHOVHZKHUHDVDSSURSULDWH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
4–23
Troubleshooting
4–24
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A
System Accessories
7KLVDSSHQGL[FRQWDLQVLQIRUPDWLRQDERXWWKHJUDSKLFVFDUGVDQGPDVVVWRUDJHGHYLFHVVXSSRUWHG
RQWKH+3,QWHJULW\U[VHUYHUDQG+3ZRUNVWDWLRQ][
■
)RUSKRWRJUDSKVRILQWHUQDOV\VWHPFRPSRQHQWVVHH&KDSWHU
■
)RUDOLVWRIV\VWHPFRPSRQHQWVDQGSDUWQXPEHUVVHH$SSHQGL[&
■
)RUDGGLWLRQDOLQIRUPDWLRQRQVXSSRUWHGDFFHVVRULHVDQGFRPSRQHQWVYLVLW
http://www.hp.com/go/bizsupport
Graphics Cards
+3,QWHJULW\U[VHUYHUDQG+3ZRUNVWDWLRQ][V\VWHPVZLWK0DQDJHPHQW3URFHVVRU
03FDUGVVXSSRUWD9*$PRQLWRUFRQQHFWHGWRWKH9*$SRUWRQWKH03FDUG
][ZRUNVWDWLRQVZLWKQR03FDUGVDUHDYDLODEOHZLWKDUDQJHRI$*3JUDSKLFVFDUGV
■
*UDSKLFVFDUGVPD\LQFOXGHDQSLQFRQQHFWRUDQSLQFRQQHFWRURUERWK2QO\RQH
FRQQHFWLQJFDEOHLVQHHGHGIRUHDFKPRQLWRU
■
6RPHYLGHRFDUGVDUHSUHLQVWDOOHGLQWKHV\VWHPZKLOHRWKHUVDUHSDFNDJHGVHSDUDWHO\DQG
VKLSSHGZLWKWKHV\VWHP,I\RXUV\VWHPGLGQRWVKLSZLWKDSUHLQVWDOOHGJUDSKLFVFDUG\RX
PXVWLQVWDOOWKHFDUGDQGORDGWKHGULYHUV5HIHUWRWKHGRFXPHQWDWLRQLQFOXGHGZLWK\RXU
JUDSKLFVFDUGIRULQVWUXFWLRQV
127(,I\RXDUHUXQQLQJ+38;RU/LQX[ZLWKDJUDSKLFVFDUGEXWFKRRVHQRWWRUXQ;6HUYHU
WKHUHDUHVHYHUDOZD\VWRSUHYHQW;6HUYHUIURPVWDUWLQJDXWRPDWLFDOO\5HIHUWR¦0DQDJHPHQW
3URFHVVRU&DUG§LQ&KDSWHU
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A–1
System Accessories
Supported Graphics Cards for systems with no MP card
'HSHQGLQJRQWKH26RQ\RXUV\VWHP\RXPD\KDYHRQHRIWKHIROORZLQJJUDSKLFVFDUGV)RUD
FRPSOHWHDQGFXUUHQWOLVWRIVXSSRUWHGFDUGVVHH
http://www.hp.com/go/bizsupport
Type of Card HP-UX
Linux
Windows
High End 3D
nVIDIA Quadro4 900XGL
nVIDIA Quadro4 980XGL
nVIDIA Quadro4 900XGL
nVIDIA Quadro4 980XGL
ATI FIRE GL X1/Z1
Entry 3D
nVIDIA Quadro2 EX
Professional 2D ATI Radeon 7000
ATI Radeon 7000
■
A–2
ATI FIRE GL 4
ATI FIRE GL X1/Z1
ATI Radeon 7000
)RUPRUHGHWDLOHGLQIRUPDWLRQDERXW\RXUJUDSKLFVFDUGVHHWKHPDQXIDFWXUHU©VZHEVLWH
❏
$7,www.ati.com
❏
19,',$www.NVIDIA.com
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Accessories
Selecting a Monitor
8VHWKHVXSSRUWHGUHVROXWLRQVDQGIUHTXHQFLHVWRVHOHFWWKHDSSURSULDWHPRQLWRUIRU\RXUJUDSKLFV
FDUG)UHTXHQFLHVRI+]DQGKLJKHUGHSHQGLQJRQPRQLWRUVL]HSURYLGHHUJRQRPLF
IOLFNHUIUHHYLHZLQJRQDQDORJ&57PRQLWRUV'LVSOD\VXVLQJ'9,QHYHUIOLFNHUWKHUHIUHVKUDWH
FKDQJHVWKHVSHHGDWZKLFKWKHLPDJHLVXSGDWHG$Q\WKLQJRYHUIUDPHVVHFLVFRQVLGHUHG
¦VPRRWKPRWLRQ§
,IWKHPRQLWRU\RXVHOHFWLV''&%RU''&%FRPSOLDQWWKHJUDSKLFVFDUGDXWRPDWLFDOO\
OLPLWVLWVHOIWRWKHUHVROXWLRQVDQGIUHTXHQFLHVVXSSRUWHGE\WKDWPRQLWRU,QWKLVFDVH\RXGRQRW
QHHGWRXVHWKHWDEOHVLQWKLVVHFWLRQWRVHOHFW\RXUPRQLWRU,IWKHGLVSOD\PRGH\RXGHVLUHLV
VXSSRUWHGE\\RXUYLGHRFDUGDQGPRQLWRUEXWQRWSDUWRI9(6$RULVQRWSURJUDPPHGLQWRWKH
PRQLWRU©V''&520\RXPD\RYHUULGHWKHGHIDXOWV
2QWKHWDEOHVWKDWIROORZ
Ä
■
2QO\FRPPRQUHVROXWLRQVDUHOLVWHG2WKHULQWHUPHGLDWHUHVROXWLRQVDUHSRVVLEOH
■
+LJKIUHTXHQFLHVPD\QRWEHDYDLODEOHDWDOOFRORUGHSWKV
CAUTION: To prevent possible damage to your monitor, make sure you select a monitor that supports
the resolutions and frequencies you want to use.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A–3
System Accessories
Supported Resolutions and Frequencies
ATI FIRE GL 4
Analog Monitor with DB-15 Connector
Display Resolution
Vertical Frequency (Hz)
1024×768
1280×1024
1600×1200
1920×1200
60,
60,
60,
60,
75,
75,
75,
75,
85,
85,
85,
85,
100
100
100
100
Digital Monitor with DVI Connector
Display Resolution
Vertical Frequency (Hz)
1024×768
1280×1024
1600×1200
60, 75
60, 75
60
ATI FIRE GL X1/Z1
127(6XSSRUWIRUWZRDQDORJRUGLJLWDOPRQLWRUV<RXFDQVHWUHVROXWLRQVDQGUHIUHVKUDWHV
LQGHSHQGHQWO\IRUWZRFRQQHFWHGGLVSOD\V
Analog or Digital Monitor with DB-15 Connector
Display Resolution
Vertical Frequency (Hz)
800×600
1024×768
1280×1024
1600×1200
1920×1200
60,
60,
60,
60,
60,
75,
75,
75,
75,
75
85, 100
85, 100
85, 100
85
Digital Monitor with DVI Connector
A–4
Display Resolution
Vertical Frequency (Hz)
800×600
1024×768
1280×1024
1600×1200
60, 75
60, 75
60, 75
60
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Accessories
ATI RADEON 7000
Analog Monitor with DB-15 Connector
127(&DQRSHUDWHZLWKWZRDQDORJPRQLWRUVXVLQJLQFOXGHGFRQYHUWHUGRQJOH
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
1920×1200
2048×1536
60,
60,
60,
60,
60,
60,
60,
72, 75, 85, 90, 100, 120, 160, 200
70, 72, 75, 85, 90, 100, 120, 160, 200
70, 72, 75, 85, 90, 100, 120, 140, 150, 160, 200
70, 75, 85, 90, 100, 125, 130, 140
66, 70, 72, 75, 76, 85, 90, 100
72, 75, 76, 80, 85
66
Digital Monitor with DVI Connector
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
60,
60,
60,
60,
60
75
75
75
75
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A–5
System Accessories
NVIDIA Quadro4 900XGL
Analog Monitor with DB-15 Connector
127(,QFOXGHVWZREXLOWLQGLJLWDOYLGHRSRUWVZLWKDQDORJFRQYHUWHUFDEOHV
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
1920×1200
2048×1536
60,
60,
60,
60,
60,
60,
60,
70,
70,
70,
70,
70,
70,
70,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75
85, 100,
85, 100,
85, 100,
85, 100,
85, 100,
85, 100
120,
120,
120,
120,
120
140,
140,
140,
140,
144,
144,
144,
144,
150, 170, 200, 240
150, 170, 200, 240
150, 170, 200, 240
150
140,
140,
140,
140,
144,
144,
144,
144,
150, 170, 200, 240
150, 170, 200, 240
150, 170, 200, 240
150
Digital Monitor with DVI Connector
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
60
60
60
60
60
NVIDIA Quadro4 980XGL
Analog Monitor with DB-15 Connector
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
1920×1200
2048×1536
60,
60,
60,
60,
60,
60,
60,
70,
70,
70,
70,
70,
70,
70,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75
85, 100,
85, 100,
85, 100,
85, 100,
85, 100,
85, 100
120,
120,
120,
120,
120
Digital Monitor with DVI Connector
A–6
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
60
60
60
60
60
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Accessories
NVIDIA Quadro2 EX
Analog Monitor with DB-15 Connector
Display Resolution
Vertical Frequency (Hz)
640×480
800×600
1024×768
1280×1024
1600×1200
1920×1200
2048×1536
60,
60,
60,
60,
60,
60,
60,
70,
70,
70,
70,
70,
70,
70,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75,
72, 75
85, 100,
85, 100,
85, 100,
85, 100,
85, 100,
85, 100
120,
120,
120,
120,
120
140,
140,
140,
140,
144,
144,
144,
144,
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
150,
150,
150,
150,
170, 200, 240
170, 200, 240
170, 200, 240
170
A–7
System Accessories
Mass Storage
Supported Hard Drives
7KHV\VWHPVXSSRUWVXSWRWKUHHLQFKLQFKKLJKKDUGGLVNWKDWPD\EHVXSSOLHGZLWKWKH
V\VWHPW\SHDQGTXDQWLW\GHSHQGVRQPRGHORQLQWHUQDOVKHOYHVFRQQHFWHGWRWKH6&6,
FRQWUROOHU
A–8
SCSI (10 krpm)
SCSI (15 krpm)
Capacity
36.4GB, 73.4GB, 146GB
36.4GB, 73.4GB
Interface
Ultra 320 SCSI
Ultra 320 SCSI
Average seek time (read)
4.9ms
3.8ms
Track-to-Track Seek Time (read) 0.55ms
0.4ms
Full Stroke Seek Time (read)
9.2ms
6.7ms
Buffer size
8 MB data buffer
8 MB data buffer
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Accessories
Supported Optical Drives
CD-RW drive
7KH&'5:IHDWXUHVLQFOXGH
■
■
■
■
■
■
■
■
■
■
&'520GDWDGLVN0RGHDQG0RGH
3KRWR&'0XOWLVHVVLRQ
9LGHR&'
&''$
&',)0:
&'520;$0RGH)RUP
(QKDQFHG&'&'3OXV&'([WUD3UHJDS0L[HG
03&,,,FRPSOLDQW
,QWHUIDFHW\SH(,'($7$3,VXSSRUWV8OWUD'0$
'9'520
5HDGDEOHGLVNV
■
■
■
■
■
■
■
■
&'&'520FPFP
&'5
&'5:
'9'520
'9'5
'9'5:
'9'5
'9'5:
:ULWDEOHGLVNV
■
■
&'5
&'5:
Write/Read Speed
Write (CD-R) 2× to 8×
Write (CD-R/W) 2×
CD-ROM Read 24× (maximum)
DVD Read 8× (read only)
DVD-RAM 4× (read only)
DVD+R 8× (read only)
DVD+RW 4× (read only)
Data capacity
650MB or up to 74 minutes of audio per disc
700MB or up to 80 minutes of audio per extended disk
547MB in CD-UDF data format
Data transfer rate
(max.)
600 KB/sec, 3600KB/sec (CD), 10,800KB (DVD)
Access Time
< 100ms
Loading Type
Manual tray
Mounting Type
Horizontal or Vertical
Data Buffer Capacity 2 MB
Rotation Method
• Constant Angular Velocity (CAV)
• Constant Linear Velocity
Reliability
MTBF 60,000 POH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A–9
System Accessories
DVD-ROM drive
7KH'9'520GULYHIHDWXUHVLQFOXGH
■
6XSSRUWHG&'520IRUPDWV
■
&'5200RGHDQGGDWDGLVN
■
3KRWR&'0XOWLVHVVLRQ
■
&'$XGLRGLVN
■
0L[HGPRGH&'520GLVNGDWDDQGDXGLR
■
&'520;$&',&'([WUD&'5&'5:
6XSSRUWHG'9'520IRUPDWV
■
'9'520
■
'9'5*%*%
■
'9'5$0*%*%
■
'9'5:
■
'9'5:
,QWHUIDFH(,'($7$3,6XSSRUW8OWUD'0$
Data Capacity:
DVD-ROM
DVD-RAM
DVD-R
DVD+R
DVD+RW
CD
A–10
Up to 8.5 GB/side
4.7 GB/side
4.7 GB/side
4.7 GB/side
4.7 GB/side
650 MB
Data Transfer Rate
8× (maximum) DVD/DVD+R
24× (maximum) CD-ROM
4× (maximum) DVD-RAM
4× (maximum) DVD+RW
Loading Type
Manual tray
Access Time
120ms (DVD)
90ms (CD-ROM)
210ms (DVD-RAM)
Data Buffer Capacity
256 KB
Acoustic Noise
45 dB
Reliability
MTBF 60,000 POH
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
B
System Board
This appendix provides an overview of the system board and describes key components
(chips) on the board:
■
,QWHOŠ,WDQLXPŠ3URFHVVRURQHRUWZRSURFHVVRUVVXSSRUWHG
■
=;,2DQGPHPRU\FRQWUROOHU
■
=;$*33&,EXVFRQWUROOHU
■
3URFHVVRUGHSHQGHQWKDUGZDUHFRQWUROOHU
■
'XDOVHULDOFRQWUROOHU
■
)LHOGSURFHVVRUJDWHDUUD\FRQWUROOHU
■
%DVHERDUG0DQDJHPHQW&RQWUROOHU
■
6&6,FRQWUROOHU
■
,'(FRQWUROOHU
■
86%FRQWUROOHU
■
%76WDQGDUG0DQDJHPHQW/$1
■
/$1
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
B–1
B–2
INTEL 82550
(550B LP-FP0)
(550C FP2-product)
Manag. &
std LAN
10/100
IDE
CDRW
& DVDR
CMD 649
6
PCI 33/32
I/O Bus
Interface
SERVER I/O RISER
PCI-X 133 “slot1”
I/O Bus
Interface
I/O Bus
Interface
I/O Bus
Interface
I/O Bus
Interface
ROPE 0
DMD
ROPE 1
266 MHz 8b data
500MB/s per rope
I/O and
Memory
Controller
SCSI BACKPLANE (SE-LVDS SCA-2 80PIN)
HDD #1
HDD #2
HDD #3
I/O Bus
Interface
WORKSTATION I/O RISER
PCI-X 133
PCI-X 133
PCI-X 133
USB
AGP 4.X 1.5V
NEC uPD720100
Keyboard
Mouse
USB
2.0
PCI-X 133 “slot1”
2
I/O Bus
Interface
I/O Bus
Interface
3
I/O Bus
Interface
PCI-X 133 “slot1”
ROPE NUMBER
4&5
PCI-X 133 “slot1”
CPU
200MHz
6.4GB/s peak data bandwidth
CPU
LAN
10/100/
1G
PCI 66/64
BMC FLASH 1MB
(on battery, scratch RAM
+ NVM + FPL forward
progress log)
LSI 1030
SCSI
U320
(external (se-lvds 68p)
Channel A
Channel B
LPC
Bus
PDH Bus
BMC SRAM 512KB
FPGA
Controller
Broadcom 5701
I/O Bus
Interface
PDH
Controller
133 MHz bus clock
266 MT/s data rate
8.5GB/s peak data bandwidth
DIMM
DIMM
DIMM
DIMM
DIMM
DIMM
MEMORY
DIMM
DIMM
DIMM
DIMM
DIMM
BMC
Bus
etc..
12C
DIAG LEDs
LAN100 BT
Remote
Access
Ports
VGA
COM 1
COM2
serial port
System/BM
console
& serial port
modem
console
VGA
ON-OFF
LAN
activity
LED STATUS PANEL
LOCATOR
EXAR
16C2550CM
(FP2-product)
DUART
RTC
(on battery, scratch)
RAM + NVM)
512KB
FMW SRAM
8MB
FMW Flash
MP Card Connectors
batt. SRAM
DRAM
Flash
etc...
I/O Bus
Interface
12C, etc...
Baseboard
Management
Controller
(BMC)
industry standard DDR266 DIMM
System Board
System Board Overview
This section provides a block diagram of the system board. For a photograph of the system
board connectors, “Location of Internal Components and Connectors” on page 2-2.
Block Diagram of the System Board
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Board
Intel® Itanium® 2 Processor
7KH,QWHOŠ,WDQLXPŠSURFHVVRUSURYLGHVWKHIROORZLQJIHDWXUHV
■
(LJKWVWDJHSLSHOLQHVL[JHQHUDOSXUSRVH$/8VWZRLQWHJHUXQLWVRQHVKLIWXQLWIRXU
IORDWLQJSRLQWXQLWV
■
6SOLW/FDFKH
■
■
❏
.%ZD\VHWDVVRFLDWLYHGDWDFDFKH
❏
.%ZD\VHWDVVRFLDWLYHLQVWUXFWLRQFDFKH
❏
E\WHOLQHVL]H
8QLILHG/FDFKH
❏
.%ZD\VHWDVVRFLDWLYH
❏
E\WHOLQHVL]H
8QLILHG/FDFKH
❏
0%ZD\VHWDVVRFLDWLYH0+]
❏
0%ZD\VHWDVVRFLDWLYH*+]
❏
0%ZD\VHWDVVRFLDWLYH*+]
❏
0%ZD\VHWDVVRFLDWLYH0+]
❏
E\WHOLQHVL]H
Processor Bus
7KH,QWHOŠ,WDQLXPŠSURFHVVRUEXV)URQW6LGH%XV)6%LQWKLVSURGXFWUXQVDW0+]
'DWDRQWKH)6%DUHWUDQVIHUUHGDWDGRXEOHGDWDUDWHZKLFKDOORZVDSHDN)6%EDQGZLGWKRI
*%VHF
ZX1 I/O and Memory Controller
7KHU[DQG][VXSSRUWWKHIROORZLQJIHDWXUHVRIWKH=;,2DQGPHPRU\FRQWUROOHU
FKLS
■
*%VSHDN,2EDQGZLGWKWKURXJKFRQFXUUHQW,2OLQNV
■
3HDNPHPRU\EDQGZLGWKRI*%V
■
PHPRU\FHOOVGDWDELWVHDFK
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
B–3
System Board
ZX1 AGP/PCI Bus Interface
7KH=;$*33&,EXVLQWHUIDFHSURYLGHVWKHVHIHDWXUHV
■
3URYLGHVLQGXVWU\VWDQGDUG$*3×DQG×VXSSRUWIRUOHJDF\JUDSKLFVDQG$*3×IRU
FXUUHQWKLJKSHUIRUPDQFHJUDSKLFV
■
3URYLGHVLQGXVWU\VWDQGDUG3&,0+]0+]3&,;0+]WR0+]RUGDWD
ELWVXSSRUW
■
6XSSRUWV$*3IDVWZULWHVRQO\WRDGGUHVVHVOHVVWKDQ*%
■
6XSSRUWV9RU8QLYHUVDONH\HG3&,FDUGV9NH\HG3&,FDUGVDUHQRWVXSSRUWHG
■
8VHVSHHUWRSHHU33VXEVHWWKDWLVUHTXLUHGE\WKH$*3VSHFLILFDWLRQZULWHRQO\3&,
F\FOHV
Dual Serial Controller
7KHGXDOVHULDOFRQWUROOHULVDGXDOXQLYHUVDODV\QFKURQRXVUHFHLYHUDQGWUDQVPLWWHU'8$57
7KLVFKLSSURYLGHVHQKDQFHG8$57IXQFWLRQVZLWKE\WH),)2VDPRGHPFRQWUROLQWHUIDFH
5HJLVWHUVRQWKLVFKLSSURYLGHRQERDUGHUURULQGLFDWLRQVDQGRSHUDWLRQVWDWXV$QLQWHUQDO
ORRSEDFNFDSDELOLW\SURYLGHVRQERDUGGLDJQRVWLFV
)HDWXUHVLQFOXGH
■
'DWDUDWHVXSWRNESV
■
$IXOO\FRPSDWLEOHFRQWUROOHU
■
$E\WHWUDQVPLW),)2WRUHGXFHWKHEDQGZLGWKUHTXLUHPHQWRIWKHH[WHUQDO&38
■
$E\WHUHFHLYH),)2ZLWKIRXUVHOHFWDEOHLQWHUUXSWWULJJHUOHYHOVDQGHUURUIODJVWRUHGXFH
WKHEDQGZLGWKUHTXLUHPHQWRIWKHH[WHUQDO&38
■
8$57FRQWUROWKDWSURYLGHVLQGHSHQGHQWWUDQVPLWDQGUHFHLYH
■
0RGHPFRQWUROVLJQDOV&76576'65'755,&'DQGVRIWZDUHFRQWUROODEOHOLQH
EUHDN
■
3URJUDPPDEOHFKDUDFWHUOHQJWKVZLWK(YHQ2GGRU1R3DULW\
■
$VWDWXVUHSRUWUHJLVWHU
Field Programmable Gate Array
7KHILHOGSURJUDPPDEOHJDWHDUUD\)3*$SURYLGHV$&3,DQG/3&VXSSRUWIRU+3,QWHOŠ
,WDQLXPŠSODWIRUPVEDVHGRQ+3FKLSVHWV7KLVFRQWUROOHUSURYLGHVWKHVHIHDWXUHV
B–4
■
$&3,LQWHUIDFH
■
/3&EXVLQWHUIDFHWRVXSSRUW%0&
■
'HFRGLQJORJLFIRU3'+GHYLFHV
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
System Board
Baseboard Management Controller
7KHEDVHERDUGPDQDJHPHQWFRQWUROOHUVXSSRUWVWKHLQGXVWU\VWDQGDUG,QWHOOLJHQW3ODWIRUP
0DQDJHPHQW,QWHUIDFH,30,VSHFLILFDWLRQ7KLVVSHFLILFDWLRQGHVFULEHVWKHPDQDJHPHQW
IHDWXUHVWKDWKDYHEHHQEXLOWLQWRWKHV\VWHPERDUG7KHVHIHDWXUHVLQFOXGHGLDJQRVWLFVERWK
ORFDODQGUHPRWHFRQVROHVXSSRUWFRQILJXUDWLRQPDQDJHPHQWKDUGZDUHPDQDJHPHQWDQG
WURXEOHVKRRWLQJ
7KHEDVHERDUGPDQDJHPHQWFRQWUROOHUSURYLGHVWKHIROORZLQJ
■
&RPSOLDQFHZLWK,QWHOOLJHQW3ODWIRUP0DQDJHPHQW,QWHUIDFH
■
7DFKRPHWHULQSXWVIRUIDQVSHHGPRQLWRULQJ
■
3XOVHZLGWKPRGXODWRURXWSXWVIRUIDQVSHHGFRQWURO
■
3XVKEXWWRQLQSXWVIRUIURQWSDQHOEXWWRQVDQGVZLWFKHV
■
2QHVHULDOSRUWPXOWLSOH[HGZLWKWKHV\VWHPFRQVROHSRUW
■
5HPRWHDFFHVVDQGLQWHOOLJHQWFKDVVLVPDQDJHPHQWEXV,&0%VXSSRUW
■
7KUHH,&PDVWHUVODYHSRUWVRQHWKHSRUWVLVXVHGIRU,30%
■
/RZSLQFRXQW/3&EXVSURYLGHVDFFHVVWRWKUHHNH\ERDUGFRQWUROOHUVW\OH.&6DQG
RQHEORFNWUDQVIHU%7LQWHUIDFH
■
ELW$505,6&SURFHVVRU
■
SLQORZSURILOHIODWSDFN/4)3SDFNDJH
■
)LUPZDUHLVSURYLGHGIRUWKHIROORZLQJLQWHUIDFHV
❏
,QWHOOLJHQWSODWIRUPPDQDJHPHQWLQWHUIDFH,30,
❏
,QWHOOLJHQWSODWIRUPPDQDJHPHQWEXV,30%
SCSI Controller
7KH6&6,FRQWUROOHULVDQ/6,/RJLF&FKLS7KLVFKLSLVIXOO\FRPSOLDQWZLWKWKH6&6,
3HULSKHUDO,QWHUIDFH6SHFLILFDWLRQ63,,WKDVWZRLQGHSHQGHQW6&6,FKDQQHOVVXSSRUWLQJ
GHYLFHVDWVSHHGVXSWR0%VHFHDFK
IDE Interface
7KH,'(LQWHUIDFHSURYLGHVVXSSRUWIRUDQLQWHUQDO&'5:RUD'9'UHDGHUWKURXJKDQLQWHUQDO
,'(FRQQHFWRUDQGFDEOH7KLVLQWHUIDFHVXSSRUWVWKHPDVWHUFDSDELOLW\
7KH,'(FRQWUROOHU3&,VXSSRUWVWKH$7$3,]HURWRILYHPRGHVIURPWR
0%V7KHXVDEOHVSHHGRQWKLVV\VWHPLVOLPLWHGWR0+]$7$PRGH0%VEHFDXVH
WKHVOLPOLQH&''9'GHYLFHVGRQRWVXSSRUWWKH$7$DQGPRGHV
7KHSULPDU\,'(FKDQQHOLVWKHRQO\FKDQQHOWKDWLVLPSOHPHQWHG7KH,'(FDEOHSURYLGHVRQO\
RQHGULYHFRQQHFWRURIWKH0DVWHUW\SHIRUWKHRSWLFDOVWRUDJHSHULSKHUDO
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
B–5
System Board
10/100 BT Standard/Management LAN
7KH%7/$1SRUWSURYLGHV
■
%DVLFUHPRWHPDQDJHDELOLW\IHDWXUHVRQWKHFRUHV\VWHP
■
$PDQDJHPHQW/$1LQWHUIDFHIRURSHUDWLQJV\VWHPOHYHOPDQDJHDELOLW\DSSOLFDWLRQVVXFKDV
7RSWRROV
■
7KH/$1FRQWUROOHULVDQ,QWHOŠFKLS
■
3RZHU2Q/$1LVDQDGGLWLRQDOIHDWXUHWKDWWKH/$1FRQWUROOHUSURYLGHV3RZHU2Q/$1
DOORZV\RXWKHDELOLW\WRSRZHUXSDV\VWHPUHPRWHO\WKURXJKWKH/$1E\VHQGLQJVSHFLDO
/$1SDFNHWVWRWKHV\VWHPWREHSRZHUHGRQ
1GB System LAN
■
0DLQV\VWHP/$1
■
0EFDSDEOH
USB Connectors
■
+LJKVSHHG0EVHFFDSDEOH
■
)XOOVSHHG0EVHFDQGORZVSHHG0EVHF
■
6XSSRUWIRU86%NH\ERDUGDQGPRXVH
❏
+38;VXSSRUWV+386%NH\ERDUGDQGPRXVH
❏
/LQX[VXSSRUWVDOO86%GHYLFHV
❏
:LQGRZVVXSSRUWV86%NH\ERDUGDQGPRXVH
Chip Spare Functionality (rx2600 Systems Only)
&KLSVSDUHHQDEOHVDQHQWLUH''56'5$0FKLSRQD',00WREHE\SDVVHGLQWKHHYHQWWKDWD
PXOWLELWHUURULVGHWHFWHGRQWKH''56'5$0,QRUGHUWRXVHWKHFKLSVSDUHIXQFWLRQDOLW\RQ
\RXUV\VWHPRQO\',00VEXLOWZLWK×''56'5$0SDUWVFDQEHXVHGDQGWKHVH',00V
PXVWEHORDGHGLQTXDGVVHHSDJH
B–6
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
C
Part Numbers
7KLVDSSHQGL[FRQWDLQVDQRYHUYLHZRIV\VWHPDFFHVVRULHVDQH[SORGHGYLHZRI+3,QWHJULW\
U[VHUYHUDQG+3ZRUNVWDWLRQ][FRPSRQHQWVDQGDFRPSRQHQWVSDUWVOLVW)RU
FRPSOHWHDQGFXUUHQWLQIRUPDWLRQRQVXSSRUWHGDFFHVVRULHVDQGFRPSRQHQWVYLVLW
http://partsurfer.hp.com
zx6000 Workstation Parts
Exploded View of zx6000 Parts
127(8VHWKHFRUUHFWIDQVIRU\RXUV\VWHPDVVKRZQE\IRRWQRWHVLQWKHGLDJUDP
DERYH
7RZHUV\VWHP
5DFNPRXQWHGV\VWHP
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
C–1
Part Numbers
7KHIROORZLQJOLVWLVIRUUHIHUHQFHRQO\DQGLVVXEMHFWWRFKDQJH)RUWKHODWHVWSDUWVLQIRUPDWLRQ
YLVLW
http://partsurfer.hp.com
Item
Description
Replacement Exchange
System Components
3
zx6000 workstation system board
A7231-67510
A7231-69510
20
zx6000 workstation AGP board
A7231-66540 N/A
22
Power supply interface module
A7231-04018 N/A
N/A
SCSI backplane
A7231-66520
A7231-69520
15
Status panel
A7231-66550
N/A
A7231-69039
Processor
6
Intel® Itanium® 2, 900 MHz
A7231-62039
6
Intel® Itanium® 2, 1.0 GHz
A7231-62030 A7231-69030
6
Intel® Itanium® 2, 1.3 GHz
A9666-67010 A9666-69010
6
Intel® Itanium® 2, 1.5 GHz
A9667-67010
A9667-69010
N/A
Processor Tool
A7231-67046
N/A
Hard Drives
18
36 GB 10 krpm, Ultra 160 SCSI, Carbon
A7835-64001 A7835-69001
18
36 GB 10 krpm, Ultra 320 SCSI, Carbon
A7835-64002 A7835-69002
18
36 GB, 10 krpm, Ultra 320 SCSI, Carbon/Port
A7835-64003 A7835-69003
18
36GB,15 krpm, Ultra320 SCSI, Carbon
A7836-64001 A7836-69001
18
36 GB, 15 krpm, Ultra 320 SCSI, Carbon/Port
A9896-64001 A9896-69001
18
73 GB 10 krpm, Ultra 160 SCSI, Carbon
A7837-64001
18
73GB 15 krpm, Ultra 320 SCSI, Carbon
A7838-64001 A7838-69001
18
73 GB, 15 krpm, Ultra 320 SCSI, Carbon/Port
A9897-64001 A9897-69001
18
146GB 10 krpm, Ultra320 SCSI, Carbon
A7839-64001 A7839-69001
18
146 GB, 10 krpm, Ultra320 SCSI, Carbon/Port
A9898-64001 A9898-69001
A7837-69001
Memory
C–2
2
256MB PC2100 ECC registered DDR-SDRAM
A6833-60001 A6833-69001
2
512MB PC2100 ECC registered DDR-SDRAM
A6746-60001 A6746-69001
2
1.0GB PC2100 ECC registered DDR-SDRAM
A6834-60001 A6834-69001
2
2.0GB PC2100 ECC registered DDR-SDRAM
A7843-67001
A7843-69001
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Part Numbers
Item
Description
Replacement Exchange
Power Supply
12
600W power supply-AC
A6874-63000 A6874-69000
4
Processor power pod
0950-4294
N/A
Graphics Cards
21
ATI FireGL 4
A7226-60520 A7226-69520
21
ATI, Fire GLX1, AGP
313287-001
312523-001
21
ATI, Fire GLZ1, AGP
313286-001
N/A
21
ATI Radeon 7000
A8049-60520 A8049-69520
21
nVIDIA Quatro2 EX
A7806-60510 A7806-69510
21
nVIDIA Quatro4 900XGL
A8064-60520 A8064-69520
21
nVIDIA Quadro4 980XGL
308961-001
21
DVI-I to DB15 Cable
A6046-63001 N/A
313285-001
I/O Cards
21
10/100BT Ethernet
P3492-63000
N/A
21
100BT Ethernet
B5509-66001
N/A
21
Single channel ultra 160 SCSI adapter
A6829-60001 N/A
21
SCSI adapter, dual port HVD/FW, PCI bus
A5159-60001 N/A
21
LAN adapter,1000 SX Gigabit
A6847-67101
N/A
21
LAN adapter,1000 SX Gigabit
A6825-67001
N/A
21
Fibre channel card, 2Gb, single port
A6795-62001
A6795-69001
21
100BTX Four Port
A5506-60102 A5506-69102
21
100BaseT PCI LAN adapter and L
B5509-66001
N/A
21
FireWire
5185-8203
N/A
21
Audio card
A7784-60501 N/A
17
Management Processor card
A7231-66580 A7231-69580
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
C–3
Part Numbers
Item
Description
Replacement Exchange
10
Super 80mm fan (zx6000 rack)
A7231-04014 N/A
11
Thin 80mm fan (zx6000 rack)
A7231-04015 N/A
9
Dual fan (zx6000 tower and rack)
A7231-04033 N/A
8
Standard 80mm fan (zx6000 tower)
A7231-04017 N/A
Fans
Cables
N/A
IDE cable
A7231-63002 N/A
23
SCSI cable A
A7231-63017 N/A
24
SCSI cable B
A7231-63018 N/A
14
Status panel cable
A7231-63003 N/A
N/A
Audio cable
8121-0808
N/A
Disk power cable
A7231-63004 N/A
N/A
80mm fan cable
A7231-63006 N/A
N/A
Super 80mm fan cable
A7231-63005 N/A
N/A
DVI-I to DB15, converter dongle
A6064-63001 N/A
N/A
Plastic Covers/Metal Latches and Chassis
C–4
N/A
Right-side rack latch
A7231-04023 N/A
N/A
Right-side rack bezel (carbon)
A7231-04038 N/A
N/A
Left-side rack bezel (carbon) and Latch
A7231-04039 N/A
N/A
Optical drive blank (carbon)
A7231-40027 N/A
N/A
Hard disk drive blank (carbon)
A6198-60003 N/A
1
System cover
A7231-04003 N/A
N/A
Rack nameplate (zx6000 rack)
A7231-40032 N/A
5
Main airflow guide (plastic)
A7231-04034 N/A
7
Front half of the airflow guide (metal)
A7231-04004 N/A
19
PCI/AGP cage
A7231-04006 N/A
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Part Numbers
Item
Description
Replacement Exchange
Tower and Rack Kit
N/A
Tower pedestal
A7231-04028 N/A
N/A
Tower pedestal covers
A7231-04041 N/A
N/A
Tower front panel
A7231-40040 N/A
N/A
Tower top cover
A7231-40036 N/A
N/A
Tower nameplate
A7231-40039 N/A
N/A
Rack standard slide, middle weight
5064-9670
N/A
N/A
Rack cable management arm
5065-5963
N/A
A7231-69012
Optical Devices
16
DVD-ROM drive, Slimline, Carbon
A7231-67012
16
CD-RW/DVD-ROM drive, Slimline, Carbon
A7231-62014 A7231-69014
Keyboards and Mice
N/A
KBD, USB, Trad. Chinese, PC-104, Quartz
A7861-65323
N/A
KBD, USB, Korean, PC-106, Quartz
A7861-65321 N/A
N/A
KBD, USB, US English, PC-104, Quartz
A7861-65301 N/A
N/A
KBD, USB, German, PC-105, Quartz
A7861-65303 N/A
N/A
KBD, USB, Spanish, PC-105, Quartz
A7861-65304 N/A
N/A
KBD, USB, French, PC-105, Quartz
A7861-65305 N/A
N/A
KBD, USB, Swiss, PC-105, Quartz
A7861-65311 N/A
N/A
KBD, USB, UK English, PC-105, Quartz
A7861-65313 N/A
N/A
KBD, USB, Japan, JIS-109, Quartz
A7861-65324
N/A
KBD, USB, Italian, PC-105, Quartz
A7861-65317 N/A
N/A
KBD, USB, Simple Chinese, PC-104, Quartz
A7861-65322
N/A
N/A
KBD, USB, Intl. English, PC-104, Quartz
A7861-65342
N/A
N/A
3-button scroll mouse, USB
A4983-60101 N/A
N/A
3-button mouse, USB
A4983-60111 N/A
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
N/A
N/A
C–5
Part Numbers
Integrity rx2600 Server Parts
Exploded View of the rx2600 Parts
C–6
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Part Numbers
7KHIROORZLQJOLVWLVIRUUHIHUHQFHRQO\DQGLVVXEMHFWWRFKDQJH)RUWKHODWHVWSDUWVLQIRUPDWLRQ
YLVLWhttp://partsurfer.hp.com
Item
Description
Replacement Exchange
System Components
3
rx2600 system board
A7231-66010 A7231-69010
20
PCI board
A7231-66530
22
Power supply interface module
A7231-04018 N/A
N/A
SCSI backplane
A7231-66520
A7231-69520
15
Status panel
A7231-66550
N/A
N/A
Processor
6
Intel® Itanium® 2, 900 MHz
A7231-62034 A7231-69034
6
Intel® Itanium® 2, 1.0 GHz
A7231-62030 A7231-69030
6
Intel® Itanium® 2, 1.3 GHz
A9666-67010 A9666-69010
6
Intel® Itanium® 2, 1.5 GHz
A9667-67010
A9667-69010
N/A
Processor Tool
A7231-67046
N/A
Hard Drives
18
36 GB 10 krpm, Ultra 160 SCSI, Flint
A6724-64001 A6538-69001
18
36 GB 10 krpm, Ultra 160 SCSI, Flint
N/A
18
36GB,15krpm, Ultra320 SCSI, Flint
A6981-64001 A7329-69001
18
36 GB, 15 krpm, Ultra 320 SCSI, Carbon/Port
A9896-64001 A9896-69001
18
73 GB 10 krpm, Ultra 160 SCSI, Flint
A6725-64001 A6539-69001
18
73 GB 10 krpm, Ultra 160 SCSI, Flint
N/A
18
73GB 15K Ultra 320 SCSI, Flint
A6983-64001 A7286-69001
18
73 GB, 15 krpm, Ultra 320 SCSI, Carbon/Port
A9897-64001 A9897-69001
18
146GB 10K Ultra 320 SCSI, Flint
A6984-64001 A7287-69001
18
146 GB, 10 krpm, Ultra320 SCSI, Carbon/Port
A9898-64001 A9898-69001
2
256MB PC2100 ECC registered DDR-SDRAM
A6833-60001 A6833-69001
2
512MB PC2100 ECC registered DDR-SDRAM
A6746-60001 A6746-69001
2
1.0GB PC2100 ECC registered DDR-SDRAM
A6834-60001 A6834-69001
2
2.0GB PC2100 ECC registered DDR-SDRAM
A7843-67001
A6571-69001
A7285-69001
Memory
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A7843-69001
C–7
Part Numbers
Item
Description
Replacement Exchange
Power Supply
12
600W power supply-AC
A6874-63000 A6874-69000
4
Processor power pod
0950-4294
N/A
I/O Cards
21
For supported I/O cards, visit: http://partsurfer.hp.com
17
Management Processor card
A7231-66580 A7231-69580
10
Super 80mm fan (rx2600 tower and rack)
A7231-04014 N/A
11
Thin 80mm fan (rx2600 tower and rack)
A7231-04015 N/A
9
Dual fan (rx2600 tower and rack)
A7231-04033 N/A
N/A
IDE cable
A7231-63002 N/A
23
SCSI cable A
A7231-63017 N/A
24
SCSI cable B
A7231-63018 N/A
14
Status panel cable
A7231-63003 N/A
N/A
Audio cable
8121-4373
N/A
Disk power cable
A7231-63004 N/A
N/A
80mm fan cable
A7231-63006 N/A
N/A
Super 80mm fan cable
A7231-63005 N/A
N/A
DVI-I to DB15, converter dongle
A6064-63001 N/A
Fans
Cables
C–8
N/A
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Part Numbers
Item
Description
Replacement Exchange
Plastic Covers/Metal Latches and Chassis
N/A
Right-side rack latch
A7231-04023 N/A
N/A
Right-side rack bezel (grey)
A7231-04025 N/A
N/A
Right-side rack bezel (graphite)
A7231-04053 N/A
N/A
Left-side rack bezel (grey) and Latch
A7231-04030 N/A
N/A
Left-side rack bezel (graphite) and Latch
A7231-04055 N/A
N/A
Optical drive blank (graphite)
A7231-40027 N/A
N/A
Hard drive blank (graphite)
A6198-60003 N/A
N/A
Optical drive blank (grey)
A7231-40026 N/A
N/A
Hard disk drive blank (grey)
A6198-60002 N/A
1
System cover
A7231-04003 N/A
N/A
Management cover plate
A7231-00072 N/A
5
Main airflow guide (plastic)
A7231-04034 N/A
7
Front half of the airflow guide (metal)
A7231-04004 N/A
19
PCI/AGP cage
A7231-04006 N/A
N/A
Rack nameplate
A7231-40003 N/A
N/A
Tower nameplate
A7231-40025 N/A
Tower and Rack Kit for the rx2600
N/A
Tower Pedestal
A7231-04028 N/A
N/A
Tower covers
A7231-04036 N/A
N/A
Tower front panel
A7231-40026 N/A
N/A
Tower top cover
A7231-40021 N/A
N/A
Rack standard slide, middle weight
5064-9670
N/A
N/A
Rack cable management arm
5065-5963
N/A
Optical Devices
16
DVD-ROM drive, Slimline, Gray
A7231-62011 A7231-69011
16
DVD-ROM drive, Slimline, Carbon
A7231-67012
16
CD-RW/DVD-ROM drive, Slimline, Gray
A7851-62015 A7851-69015
16
CD-RW/DVD-ROM drive, Slimline, Carbon
A7231-62024
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
A7231-69012
A7231-69024
C–9
Part Numbers
Item
Description
Replacement Exchange
Keyboards and Mice
C–10
N/A
KBD, USB, Trad. Chinese, PC-104, Quartz
A7861-65323
N/A
N/A
KBD, USB, Korean, PC-106, Quartz
A7861-65321 N/A
N/A
KBD, USB, US English, PC-104, Quartz
A7861-65301 N/A
N/A
KBD, USB, German, PC-105, Quartz
A7861-65303 N/A
N/A
KBD, USB, Spanish, PC-105, Quartz
A7861-65304 N/A
N/A
KBD, USB, French, PC-105, Quartz
A7861-65305 N/A
N/A
KBD, USB, Swiss, PC-105, Quartz
A7861-65311 N/A
N/A
KBD, USB, UK English, PC-105, Quartz
A7861-65313 N/A
N/A
KBD, USB, Japan, JIS-109, Quartz
A7861-65324
N/A
KBD, USB, Italian, PC-105, Quartz
A7861-65317 N/A
N/A
KBD, USB, Simple Chinese, PC-104, Quartz
A7861-65322
N/A
N/A
KBD, USB, Intl. English, PC-104, Quartz
A7861-65342
N/A
N/A
3-button scroll mouse, USB
A4983-60101 N/A
N/A
3-button mouse, USB
A4983-60111 N/A
N/A
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D
Event, Error and Warning Messages
7KLVDSSHQGL[FRQWDLQVHYHQWHUURUDQGZDUQLQJLQIRUPDWLRQIRUWKHU[DQG][V\VWHPV
■
¦(),(UURUDQG:DUQLQJ0HVVDJHV§RQSDJH'
■
¦6(/DQG)3//RJ(QWULHV§RQSDJH'
EFI Error and Warning Messages
(),HUURUDQGZDUQLQJPHVVDJHVDUHGLVSOD\HGRQWKHFRQVROHDVSDUWRIWKHERRWSURFHVV7KH\
FDQDOVREHUHWULHYHGYLDWKHinfo warnings(),FRPPDQG
Error Number
Error/Warning Message
Solution
2
Insufficient resources to assign to one or
more I/O devices
—
3
Failed I/O socket(s) deconfiguration
—
4
Unexpected hardware I/O configuration
—
7
No BMC installed in platform
Ensure the BMC ROM is installed;
update BMC firmware
8
BMC cannot be accessed
Check BMC logs for errors
9
One or more BMC ports failed
—
10
BMC system event log is full
Clear SEL
11
Platform SCR is bad
Call support center
12
Set time to BMC SEL failed
—
13
SEL get info failed
—
14
Initial BMC SEL event failed
—
15
Update of BMC buffered data failed
—
16
All ACPI BMC ports bad
—
17
Read error on BMC token
—
18
BMC token transmit checksum error
—
19
Error writing BMC token on download
—
20
NVM token access error
—
21
BMC token write error during NVM write
through
—
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–1
Event, Error and Warning Messages
Error Number
D–2
Error/Warning Message
Solution
22
Error reading BMC token on upload to
NVM
—
23
Error reading BMC first boot token
—
24
Primary FIT failed
Reflash firmware
25
Secondary FIT failed
Reflash firmware
26
PAL_A warning. One copy of PAL is bad
Reflash firmware
27
PAL_B warning. Not compatible with at
least one CPU
Update firmware
28
Memory errors detected and PDT is
disabled
Reseat DIMMs, if error persists
replace bad DIMMs
30
Memory required reinterleave to get a
good page 0
—
31
One or more ranks have chipspare
disabled
—
33
One or more memory ranks are
mismatched and deallocated
34
Memory deallocated because of a loading Fix memory loading order
error
(page 2-25)
35
Memory is not loaded recommended
loading order
Fix memory loading order
(page 2-25)
36
The PDT is full
Clear with pdt clear command in
EFI shell
37
At least one (1) CPU has bad fixed core
ratio
—
38
All CPUs were slated for compatibility
deconfig
—
39
Incompatible CPUs detected
Call support center
40
CPUs installed with mixed cache sizes
This will always cause a stopboot
41
CPUs installed with mixed steppings
—
42
All CPUs are over clocked
—
43
At least one (1) CPU is over clocked
—
44
Monarch changed to lowest stepping CPU Only seen once after monarch is
set to lowest stepping
46
CPUs loaded in wrong order
48
SAL NVM cleared
Fix memory loading order
(page 2-25)
—
Information only, no action
required
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
Error Number
Error/Warning Message
Solution
49
EFI NVM cleared
Information only, no action
required
50
EFI NVM failed
—
51
CPU deconfigured by SAL_B
—
52
A ROM revision is inconsistent with FIT or
REVBLOCK
One or more firmware components
(fw, bmc, mp) is out of date.
Update Firmware.
53
Error building SMBIOS
Call Support Center
54
Failure constructing the EFI Memory Data
Table (MDT)
Call Support Center
55
UUID error
Call Support Center
56
Error reading CPU SMBUS information
ROM
—
57
Error accessing FRU information
—
58
Checksum error accessing FRU information
—
59
FRU information version error
—
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–3
Event, Error and Warning Messages
SEL and FPL Log Entries
7KLVVHFWLRQLVDTXLFNUHIHUHQFHIRUWKH,30,HYHQWVUHFRUGHGLQWKH6(/DQG)3/ILOHV7KHVH
ORJVDUHDYDLODEOHYLDWKH03FDUGLQWHUIDFHRUWKH%0&&/,
■
$OOHQWULHVIURPWKH6(/DUHIRUZDUGHGWRWKH)3/7KH)3/LVDFLUFXODUORJVRWKHQHZHVW
HQWULHVUHSODFHWKHROGHVW7KH)3/FRQWDLQVIRUZDUGSURJUHVVPHVVDJHVIURPWKH%0&
6\VWHPILUPZDUH(),DQGWKH26
■
7KH6(/ZLOOQRWDFFHSWQHZHQWULHVRQFHLWLVIXOODQGFRQWDLQVRQO\WKRVHHYHQWVFRQVLGHUHG
RIPDMRULPSRUWDQFHWRV\VWHPRSHUDWLRQ
■
%RWKFRQWDLQW\SHDQG(PHVVDJHV
■
$WULSOHWLVIRUPHGIURPWKH6HQVRU7\SH(YHQW7\SHDQGWKHORZHUQLEEOHRIWKH'DWD
ILHOGVRI7\SHHYHQWV03ILUPZDUHGLVSOD\VWKHWULSOHWLQWKH.H\ZRUGILHOG
127(6\VWHPVZLWKZLWK)LUPZDUHYHUVLRQRUKLJKHUDOVRKDYHDclearlogsFRPPDQGWKDW
ZLOOFOHDURXWWKHORJILOHVVKRXOGWKH\EHFRPHIXOO
D–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
Accessing the Logs with BMC CLI Commands
7KHfplFRPPDQGGLVSOD\VWKHIRUZDUGSURJUHVVORJ)RUH[DPSOH
1
2
0000000E 0000000F 2
00000010 2
00000011 0
00000012 0
00000013 1
00000014 1
00000015 0
00000016 0
00000017 0
00000018 0
00000019-
3
4
5
6
7
Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
CPU0 Boot start 00063 DT 06 0000000000000000
CPU0 Boot start 00063 Time 2003-02-28 16:41:46
CPU0 00020 DT 00 0000000000000000
CPU0 0000E DT 06 0000000000010000
CPU0 CPU monarch 0000C DT 06 0000000000000000
CPU0 CPU present 00261 DT 06 0000000000000000
CPU0 00008 DT 00 0000000000000000
CPU0 0024B DT 00 0000000000000000
CPU0 00006 DT 03 0000000000000000
CPU0 00044 DT 06 02000000002C0400
BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
7KHselFRPPDQGGLVSOD\VWKHV\VWHPHYHQWORJ)RUH[DPSOH
1
2 3 4 5 6 7
00E0 - Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
00F0 2 CPU0 Boot start 00063 DT 06 0000000000000000
0100 2 CPU0 Boot start 00063 Time 2003-02-28 16:41:46
0110 - BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
(DFKFROXPQLQWKHORJFRQWDLQVDGLIIHUHQWGDWDILHOG
5HFRUG,'
6HYHULW\IRU(PHVVDJHV
*HQHUDWRULGRUVHQVRUUHSRUWLQJWKHHYHQW
7H[WGHVFULSWLRQRIHYHQWV
6HQVRUQXPEHU6HQVRU7\SH(YHQW7\SH'DWDILHOGVIRUW\SHPVJVWULSOHWHYHQWLGIRU(PVJV
'DWDDQG'DWDIRUW\SHPVJVLIDSSOLFDEOHRU'DWDW\SHIRU(PHVVDJHV
7LPHVWDPSRUH[WHQGHGGDWDVSHFLILFWRWKHHYHQW
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–5
Event, Error and Warning Messages
Accessing the Logs with MP Commands
7KH6(/DQG)3/GDWDFDQDOVREHDFFHVVHGIURPWKH03ORJVXVLQJWKH03FDUGSL FRPPDQG
/RJVFDQEHGLVSOD\HGLQWKUHHPRGHVUDZKH[WH[WRUNH\ZRUG
■
03ILUPZDUH(¥7KHSDMVHWGLVSOD\PRGHFRPPDQGGHWHUPLQHVWKHIRUPDWRI
WKHGLVSOD\
■
03ILUPZDUH(RUKLJKHU¥2XWSXWPRGHLVVHOHFWHGIURPDPHQXZKHQWKHORJLV
GLVSOD\HG
+H[0RGH([DPSOH
13
0x203E5F914A0200E0 FFFF010944080300
14
0x5680006300E000F0 010000003E5F914A
14
0x5680006300E000F0 0000000000000000
15
0x203E5F914B020110 FFFF027000120300
7H[W0RGH([DPSOH
Log Entry 13: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: Type-02 080901 526593
Power supply turned on
Logged by: BMC;
Sensor: Power Supply - Pwr Spply 1 Ctrl
Data1: Device Enabled
0x203E5F914A0200E0 FFFF010944080300
Log Entry 14: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: BOOT_START
CPU starting boot
Logged by: System Firmware
0
Data: Implementation dependent data field
0x5680006300E000F0 0000000000000000
Log Entry 15: 28 Feb 2003 16:41:47
Alert Level 2: Informational
Keyword: Type-02 127002 1208322
Soft Reset
Logged by: BMC;
Sensor: System Event
0x203E5F914B020110 FFFF027000120300
D–6
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
.H\ZRUGPRGHH[DPSOH
13
BMC
2
0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593
28 Feb 2003 16:41:46
14
SFW
15
BMC
0
2
0x5680006300E000F0 0000000000000000 BOOT_START
28 Feb 2003 16:41:46
2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322
28 Feb 2003 16:41:47
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–7
Event, Error and Warning Messages
System Specific Events
OEM SensorType 12, EventType 71
0LVVLQJ&RPSRQHQWVDUHGHWHUPLQHGDWWKHWLPHRIDSRZHURQUHTXHVWFDXVHDIDLOXUHLQWKH
UHTXHVWDQGFDXVHWKHHYHQWWREHORJJHG
Data2
Data3
Missing Component
0x0C-0F
Power Pod 0-3
0x20-23
CPU 0-3
0x1E
0x01
Cooling Unit 1
0x1E
0x01
Cooling Unit 3
0x1E
0x03
Cooling Unit 3
Chassis Control Event Codes
)RU%0&UHYDQ6(/HYHQWZLOOEHORJJHGIRUHDFK&KDVVLV&RQWUROHYHQWZKHWKHULW©V
JHQHUDWHGE\DQ,30,UHTXHVWRUDVHQVRUHYHQW
/DWHUUHYLVLRQVRI03ILUPZDUHUHFRJQL]HWKHWULSOHW$DV&KDVVLV&RQWURO
7KH(YHQW'DWDILHOGVDUH
■
'DWD[$LQGLFDWLQJ2(0GDWDLQ'DWDDQG'DWDDQG2(0RIIVHW
■
'DWD
■
D–8
❏
>@ 5HTXHVWJHQHUDWHGE\D6HQVRU(YHQW
❏
,30,UHTXHVW
❏
>@5HVHUYHG
❏
>@&KDVVLV&RQWUROFRPPDQG
'DWD6HQVRU1XPEHURU,30,5HTXHVW2ULJLQ
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
Chassis Control Commands
Command
Description
0x00
Hard Power Down
0x01
Power Up
0x03
Hard Reset
0x04
NMI/TOC/INIT
0x0D
Soft Shutdown and Restart
0x0E
Soft Shutdown
Sensor Numbers
Sensor Number
Description
0x04
Power Button
0x0E
Wake on Lan
0x11-13
Cooling Units
0x40-41
Power Supplies
0xCD-D3, 0xD5-D6
Voltage Sensors
0xD8
Ambient Temp
0xD9-DA
CPU Temps
0xFA
ACPI
IPMI Origins
Number
Source
0x01
BT
0x03
CLI
0x07
IP MB
0x08
I2C1
0x09
I2C2
0x0F
KCS0
0x10
KCS1
0x11
KCS2
0x1F
System Power Thread
(Used by Power Restore Policy)
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–9
Event, Error and Warning Messages
)RUH[DPSOH
Data2
80 03
81 03
80 01
83 03
00 FA
00 D9
01 0E
D–10
Data3
ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_DOWN (“p 0”)
ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_UP (“p 1”)
ipmi req from via BT for CHASSIS_CONTROL_POWER_DOWN
ipmi/RS req from the CLI thd for CHASSIS_CONTROL_HARD_RESET
CHASSIS_CONTROL_POWER_DOWN req from the ACPI sensor (S5)
CHASSIS_CONTROL_POWER_DOWN req from CPU0 temp sensor
CHASSIS_CONTROL_POWER_UP req from WakeOnLan sensor
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
Events Without Sensors
7KH%0&ORJVWKHVHHYHQWVZLWKD¦VHQVRUQXPEHU§RIWKHUHLVQRPDWFKLQJ6'5HQWU\
Triplet
Event
data2
data3
Notes
10:70:64
SEL almost full
1F
%full
The BMC logs this when the SEL is
75% full
12:70:04
BMC entering firmware
update mode
12:70:05
SFW flash lnlock
System firmware update in
progress
12:70:06
Front panel lock
Disables all power and reset
requests from ipmi or sensors
12:F0:06
Front panel unlock
12:70:07
Firmware update app:
starting component cpdate
12:F0:07
Firmware update app:
ending comionent update
12:70:80
BMC entering special
mode
Mode
12:70:A1
BMC firmware initializing
Major FW Minor
rev
FW rev
1D:70:00
BMC cold reset
1D:70:01
BMC warm reset
1D:70:02
BMC cold reset after SDRR
update
–
Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
D–11
Event, Error and Warning Messages
D–12
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Index
A
$FFHVVRU\FDUGVRFNHWV¤
$FFHVVRU\FDUGV¤
$GPLQLVWUDWRU¤
$GYDQFHG6\VWHP&RQILJXUDWLRQ0HQX¤
$GYDQFHG6\VWHP,QIRUPDWLRQ0HQX¤
$*3¤¤¤¤¤%¤
$LUIORZJXLGHV¤
$OWLWXGH¤
B
%DVHERDUGPDQDJHPHQWFRQWUROOHU%¤
%DWWHU\¤
%H]HO¤¤¤
%0&¤%¤
%0&&/,'¤
%0&FRPPDQGV¤
%RRW¤
%RRW2SWLRQ0DLQWHQDQFH0HQX¤
%RRWDEOH'HYLFHV¤
'9'¤¤¤$¤$¤%¤
E
HEX]]HU¤¤¤
H'LDJ7RROV¤¤
(),¤
(),FRPPDQGV¤¤
(),HGLWRU¤
(),HUURUDQGZDUQLQJPHVVDJHV'¤
(),VFULSWV¤
(),VKHOO¤¤
(OHFWURVWDWLFGLVFKDUJH¤
(0,¤
(QYLURQPHQWDOVSHFLILFDWLRQV¤
(UURU'¤
(6'¤
(YHQW'¤
([WHQVLEOH)LUPZDUH,QWHUIDFH¤
F
&DFKH¤%¤
&'¤¤¤$¤%¤
&KLS5HYLVLRQ¤
&KLSVSDUH%¤
FRPPDQGV¤
&RQILJXUDWLRQV¤
FRQQHFWRUV¤
&RQVROH¤¤
&RYHU¤
&RYHUV¤
)LHOGSURJUDPPDEOHJDWHDUUD\%¤
)LUPZDUH¤¤
)LUPZDUHXSJUDGHV¤
ILUPZDUHYHUVLRQ[¤
ILUPZDUHYHUVLRQ¤
)RRWSULQW¤
)3*$%¤
)3/'¤
)UHTXHQF\$¤
)URQWSDQHO¤
)URQW6LGH%XV%¤
)6%%¤
D
G
C
'DWH¤
'HIDXOW¤
GLDJQRVWLF¤
'LDJQRVWLF/('V¤¤
'LPHQVLRQV¤
',00V¤
'LVN$FWLYLW\/('V¤
'XDOVHULDOFRQWUROOHU%¤
*LJDELW/$1¤¤
*UDSKLFV¤¤¤¤$¤
*UDSKLFVFDUG¤
H
+DUGGULYHEDFNSODQH¤
+DUGGULYHV¤¤¤¤$¤
KHOS¤
+RWSOXJ¤
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Index–1
Index
+RWSOXJJDEOH¤
+RWVZDSSDEOH¤¤
+3H'LDJ7RROV¤¤
+3,3)2IIOLQH'LDJQRVWLFVDQG8WLOLWLHV&'¤
+38;¤
+XPLGLW\¤
2'(¤¤
2IIOLQH'LDJQRVWLFV(QYLURQPHQW¤¤
2SHUDWLQJV\VWHP¤
2SWLFDOGULYH¤¤¤$¤
26¤
I
P
,2EXVLQWHUIDFH%¤
,2FRQWUROOHU%¤
,'(¤¤%¤
,QVWDOOSDUWV¤
,QWHOOLJHQW3ODWIRUP0DQDJHPHQW,QWHUIDFH¤
,30,¤¤%¤'¤
,30,FRPPDQGV¤
,WDQLXP%¤
J
-XPSHU¤
K
.H\ERDUG¤
L
/$1¤¤¤
/$1/('¤¤
/$1/('V¤
/('VWDWXVSDQHO¤
/('V¤¤
/LQX[¤
/RFDWRUEXWWRQ¤¤
/RFDWRU/('¤¤
ORFN¤
M
3DUWQXPEHUV&¤&¤&¤
SDVVZRUG¤
3DVVZRUGV¤¤¤
3DWKV¤
3&,¤¤¤¤
3&,&DUGV¤
SRUWV¤
3RZHU¤¤¤¤¤
3RZHUDQGV\VWHP/('V¤
3RZHUVXSSOLHV¤¤
3RZHUVXSSO\LQWHUIDFH¤
3URFHVVRU¤¤¤¤%¤
3URFHVVRUDLUIORZJXLGH¤
3URFHVVRUEXV%¤
3URGXFWLQIRUPDWLRQ¤
36,¤
R
5DFNPRXQW¤¤¤
5HDUSDQHO¤
5HPRWHDFFHVV¤
UHVHW¤
5HVHW&RQILJXUDWLRQWR'HIDXOW¤
5HVROXWLRQ$¤
S
0DQDJHPHQW3URFHVVRU¤¤¤$¤
0DQDJHPHQW3URFHVVRU&DUG¤
0DWFKHGTXDGV¤
0HPRU\¤¤¤¤
0HPRU\DLUIORZJXLGH¤¤
0HPRU\FRQWUROOHU%¤
0HPRU\ORDGLQJRUGHU¤
0RQLWRU¤$¤
0RXVH¤
03¤¤¤¤¤$¤
03FDUG¤
03FRPPDQGSURPSW¤
03FRPPDQGV¤
03/$1¤¤¤
Index–2
O
6DIHW\L¤LLL
VFULSWV¤
6&6,¤¤¤¤$¤%¤
VHFXULW\¤¤
6HFXULW\3DVVZRUG0HQX¤¤¤
6(/¤'¤
6HULDO¤¤
6HULDOSRUWV¤
6HUYHU¤
6HW6\VWHP'DWH¤
6HW6\VWHP7LPH¤
6/¤
VWDUWXSQVK¤
6XSSRUW¤
6XSSRUWWLFNHW¤
6\VWHPDFFHVVRULHV$¤
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Index
6\VWHPERDUG¤¤¤¤%¤%¤
6\VWHPFRQILJXUDWLRQ¤
6\VWHP&RQILJXUDWLRQ0HQX¤
6\VWHP(YHQW/RJ¤
6\VWHPIDQV¤¤
6\VWHP/('¤¤
6\VWHP0DQDJHPHQW/$1¤¤
T
7HPSHUDWXUH¤
7HUPLQDOHPXODWLRQ¤¤¤
7LPH¤
72&EXWWRQ¤
7RROV¤
7RZHU¤¤¤
7URXEOHVKRRWLQJ¤¤
U
86%¤¤
8VHU¤
V
9*$¤¤¤$¤
9LGHR¤¤¤¤$¤
W
:DUQLQJV'¤
:HLJKW¤
:LQGRZV¤
:RUNVWDWLRQ¤
Z
=;,2%¤
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Index–3
Index
Index–4
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide