Download Windhager VarioWIN Specifications
Transcript
Care, cleaning and maintenance 3.7 VarioWIN reserve supply container It is necessary to clean the reserve supply container if too much dust has collected on the sides or at the opening above the auger, or there are foreign bodies in the reserve supply container. In order to be able to check this, there must not be any pellets in the reserve supply container. Therefore, allow the pellets in the reserve supply container to be consumed or, in the case of the VarioWIN with pneumatic feed (suction system), switch off the feed on the day before (see section 2.10.1.3 Setting the feed operating mode). Cleaning VarioWIN Exklusiv-S with manual filling: – Switch off the VarioWIN with the ON/OFF button on the InfoWIN (Fig. 131) and wait until the display has gone out. – Open the cover of the reserve supply container (Fig. 132) and vacuum out the pellets, dust or foreign bodies through the mesh using a vacuum cleaner. Fig. 131 Switching off the VarioWIN Fig. 132 47 Folding open the cover