Download Windhager VarioWIN Specifications
Transcript
Important information for system operators 1.7 Sources of danger 1.7.1 Fire protection The entire system must comply with technical fire protection requirements in accordance with the applicable regulations, standards and guidelines. 1.7.2 Power failure (or if the blower is not running) Do not open the combustion chamber door, there is an increased risk of deflagration when opening the combustion chamber door. A self-test is performed following a power failure during combustion and then operation is continued automatically. 1.7.3 Burner pot Never fill the burner pot with pellets by hand. Excessive combustion material in the burner pot means that the pellets will not be ignited optimally. Too much low temperature carburisation gas will be generated and this can lead to deflagration. 1.7.4 Heating door and ash door handles Warning of hot surface: risk of burns! Before touching the combustion chamber and ash door handles, you must switch off the boiler and let it cool. 1.7.5 Direct pellet feed Please note: Risk of crushing from rotating auger. Before entering the pellet store or handling the unit with the auger open, always de-energise the boiler. Never operate the boiler with the extraction port (auger) open! 1.7.6 Entering the pellet storage room, storage container In certain conditions, higher concentrations of harmful gases (e.g. carbon monoxide) may build up in pellet storage rooms. If these are allowed to build up over long periods, it may present a hazard. Even though there is no risk under normal circumstances, this scenario cannot be completely ruled out. – When working in filled pellet storage rooms, in the interests of safety a second person should always remain outside the storage room. Always air pellet stores thoroughly before entering. – For stores that are difficult to access or only accessible from above (e.g. buried tanks), the person entering the store should use additional safety equipment. – Keep children away from the pellet store! Do not attempt to enter an unaired storage room (particularly buried tanks). 7