Download Whirlpool W10115229B-SP Specifications
Transcript
Installation clearances: The location must be large enough to allow the dryer door to open fully. Most installations Requirements." require a minimum 51/2"(140 mm) clearance behind the dryer for the exhaust vent with elbow. See "Venting 29" Wide Models Dryer Dimensions 27" Wide Models Dryer Dimensions 223/4" _=/8" I IIIIIF_ (110=retail II 228h ,, i t=(578ram) i ,3'/8" / Ii III-( J I( " 11 (-02mm ,=0 II II (660ram} 23%" I/ k II (1092 mn_) 1t092 ram) Ilk Ill __...J])JI1349 ram) 13=A" i \ (705mm)._ (749 rnrn} X _--._. (737ram) A -27" -'" (749 ram) \ ,'%F (687 ram) -_ (737_m) 27" .- -27" _="(687 ram} A _'" B A. Large opening side-swing door B. Wide opening hamper door 228/4" Installation _8/8,, I _ ..__._._____(578 ram) _8/8"i Spacing _f I I1 ', (1102mm)1III/ (1102mm) II_]_ "273/,"_ \ I '-_--'-'--_-JII _ l_II _8,,, -- "273/""'_ _' II _ 1705mm). _r-_. _ _ __ 3 I1. -_6 ram) 14"max,* 7 --_in._ (310cm) (705ram),__, (737ram) C (737ram) D __ 24i_* 3"* A. B. C. D. Large Large Wide Wide opening opening opening opening side-swing door side-swing door side-swing door hamper door \I i_ (457 mm_l _.=_] o/' max,' - I_ II;._ mm 310cm)__ o ii [_ -.. (76ram) -T 48in_* 24in. 2.(155 cm)_ 1"-_ _- 29"-_ _- 1" -_1"*_ 273_"H5V]'_ _(25ram} (737mm) (25mm)(25mm)(705mrn} (140ram} A B Installation spacing for recessed area or closet The dimensions shown are for the minimum spacing allowed. [] Additional spacing should be considered for ease of installation and servicing. [] Additional clearances might be required for wall, door, and floor moldings. [] Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. [] For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. [] Companion [] Metal exhaust system hardware, available for purchase. For further information, please reference the "Assistance Service" section of the "Dryer User Instructions." (76 rnm} C *Required spacing home-Additional installation appliance spacing should also be considered. requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard CAN/CSA-Z240 MH. 6 C *Required spacing A. Recessed area B. Side view - closet or confined area C. Closet door with vents Mobile T A. Recessed area B. Side view - closet or confined area C. Closet door with vents 3"* E} ._ (76 ram) 1"-_t I_ 27"_ I<- 1" (25ram) (686mm) (25mm) (25mm) (748mm} (148mm} A B installation Spacing _ _ k_ (1550m: and [] or Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
This document in other languages
- français: Admiral NGD5100TQ2