Download Midas XL401 Specifications
Transcript
The PAD switch gives 20dB of attenuation to the mic signal and will allow the connection of high output microphones or line level signals. If the mic amp is transformer coupled ( option ) the pad greatly reduces the risk of saturation at very low frequencies. The 48V switch connects 48 volt phantom power to the mic input suitable for a condenser microphone or DI box. The METER monitors the peak signal level of the input channel pre fader. When the GLOBAL METER CHANGE OVER switch on the COMMS module is activated the meter monitors the mic amp or line amp output (which ever is in use ). The PHASE switch activates a 180 degrees phase change on both the mic and line inputs. This switch is under automation control. 2 MIDAS +25 +35 -20 48V The MIC control gives continuous adjustment of the mic amp gain from + 15dB to + 70dB. +15 +70 mic +21 +18 0 +15 +12 +9 +6 +20 +3 -20 0 -3 -6 -9 -12 line -15 10k 3k -18 -21 -24 -27 1k 40k -30 lo-pass -33 30 100 -36 / O XL402 10 400 hi-pass The LINE control gives continuous adjustment of the line amp gain from - 20dB to + 20dB. The LINE switch connects the line input to the signal path and disconnects the mic amplifier. This switch is under automation control. The LO PASS filter control acts on the mic input only and is continuously adjustable from 1K to 40K. When the filter is set to 40K there is no loss at 20K. The HI PASS filter control acts on the mic input only and is continuously adjustable from 10Hz to 400Hz. When the filter is set to 10Hz there is no loss at 20Hz.