INSTALLATION ELECTRIC The appliance is shipped from the factory without cord. Refer to wiring circuit diagram (pages 44-46) for installation assistance. The appliance is shipped wired for a 3-phase application. The 240 volt fryers may be changed to single phase operation, as indicated in the chart below. A licensed electrician may be required. Check local codes. Following is a copy of the electrical information on the name plate for various models of Winston’s Collectramatic® fryers. Model Volts Hertz PH Amps Watts Circuit Amp PF46C 208 60 3 29.2 10,500 US 50 240 60 1 43.7 10,500 US 60 240 60 3 25.2 10,500 US 50 PF56C 208 60 3 29.2 10,500 US 50 240 60 1 43.7 10,500 US 60 240 60 3 25.2 10,500 US 50 OF49C 208 60 3 29.2 10,500 US 50 240 60 1 43.7 10,500 US 60 240 60 3 25.2 10,500 US 50 OF59C 208 60 3 29.2 10,500 US 50 240 60 1 43.7 10,500 US 60 240 60 3 25.2 10,500 US 50 www.winstonind.com 800-234-5286 6 Collectramatic® Fryers - 8000 Series Control - OF49C, OF59C, PF46C, PF56C - KFC