Download Schmid Watson Installation guide

Transcript
SZ-DOC-W5-1.pdf
Version: 1.5
LTU/NTU
Operating Manual
7.3.3.3 ALARM Command
The ALARM command displays the actual alarm status:
LTU_01_FMM> ALARM
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Alarm Status
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LOS-S:off
AIS-S:off LOOP1:off ACO:off
EXT-LOC:off
LFA-S:off
BER-S:off LOOP2:off ALB:off
LOOPREG:off
LOSW-A:off BER-A:off SEG-A:off CLD-A:off BERT:off
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
*** Warning: PID alarm detected – use straight pair cabling for this
connection
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_01_FMM>
Options:
T
Turns alarm trace on / off
Definitions:
LOS-S:
Loss of signal at subscriber (E1) side
LFA-S:
Loss of frame alignment at subscriber (E1) side
AIS-S:
AIS (Alarm Indication Signal) detected at subscriber (E1) side
BER-S:
Excessive Block Error Rate on subscriber side
If CRC4 enabled : BER-S = on if more than 805 CRC4 Errors per second.
If CRC4 disabled : BER-S = on if more than 28 FAS Errors per second.
53
EXT-LOC:
Loss of external clock
LFA-V3
Loss of frame alignment at V3-reference point (PRA mode)
AIS-V3
Alarm indication signal at V3-reference point (PRA mode)
LOSW-A
Loss of Sync Defect (LOSW defect) on channel A
LOSW-B
Loss of Sync Defect (LOSW defect) on channel B
BER-A:
SHDSL block-error-rate according G.826 ≥ 30% on channel A
BER-B:
SHDSL block-error-rate according G.826 ≥ 30% on channel B
LOOP1:
SHDSL test loop 1 active (see section 0)
LOOP2:
SHDSL test loop 2 active
ACO:
Alarm cutoff
ALB:
Analog loopback
SEG-A:
Segment defect alarm indication if regenerators present on channel A
Revision: 2002-09-10